1000 resultados para Baer Assessment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The introduction of engineered nanostructured materials into a rapidly increasing number of industrial and consumer products will result in enhanced exposure to engineered nanoparticles. Workplace exposure has been identified as the most likely source of uncontrolled inhalation of engineered aerosolized nanoparticles, but release of engineered nanoparticles may occur at any stage of the lifecycle of (consumer) products. The dynamic development of nanomaterials with possibly unknown toxicological effects poses a challenge for the assessment of nanoparticle induced toxicity and safety.In this consensus document from a workshop on in-vitro cell systems for nanoparticle toxicity testing11Workshop on 'In-Vitro Exposure Studies for Toxicity Testing of Engineered Nanoparticles' sponsored by the Association for Aerosol Research (GAeF), 5-6 September 2009, Karlsruhe, Germany. an overview is given of the main issues concerning exposure to airborne nanoparticles, lung physiology, biological mechanisms of (adverse) action, in-vitro cell exposure systems, realistic tissue doses, risk assessment and social aspects of nanotechnology. The workshop participants recognized the large potential of in-vitro cell exposure systems for reliable, high-throughput screening of nanoparticle toxicity. For the investigation of lung toxicity, a strong preference was expressed for air-liquid interface (ALI) cell exposure systems (rather than submerged cell exposure systems) as they more closely resemble in-vivo conditions in the lungs and they allow for unaltered and dosimetrically accurate delivery of aerosolized nanoparticles to the cells. An important aspect, which is frequently overlooked, is the comparison of typically used in-vitro dose levels with realistic in-vivo nanoparticle doses in the lung. If we consider average ambient urban exposure and occupational exposure at 5mg/m3 (maximum level allowed by Occupational Safety and Health Administration (OSHA)) as the boundaries of human exposure, the corresponding upper-limit range of nanoparticle flux delivered to the lung tissue is 3×10-5-5×10-3μg/h/cm2 of lung tissue and 2-300particles/h/(epithelial) cell. This range can be easily matched and even exceeded by almost all currently available cell exposure systems.The consensus statement includes a set of recommendations for conducting in-vitro cell exposure studies with pulmonary cell systems and identifies urgent needs for future development. As these issues are crucial for the introduction of safe nanomaterials into the marketplace and the living environment, they deserve more attention and more interaction between biologists and aerosol scientists. The members of the workshop believe that further advances in in-vitro cell exposure studies would be greatly facilitated by a more active role of the aerosol scientists. The technical know-how for developing and running ALI in-vitro exposure systems is available in the aerosol community and at the same time biologists/toxicologists are required for proper assessment of the biological impact of nanoparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Positron emission tomography (PET) during the cold pressor test (CPT) has been used to assess endothelium-dependent coronary vasoreactivity, a surrogate marker of cardiovascular events. However, its use remains limited by cardiac PET availability. As multidetector computed tomography (MDCT) is more widely available, we aimed to develop a measurement of endothelium-dependent coronary vasoreactivity with MDCT and similar radiation burden as with PET. METHODS AND RESULTS: A study group of 18 participants without known cardiovascular risk factor (9F/9M; age 60±6 years) underwent cardiac PET with (82)Rb and unenhanced ECG-gated MDCT within 4h, each time at rest and during CPT. The relation between absolute myocardial blood flow (MBF) response to CPT by PET (ml·min(-1)·g(1)) and relative changes in MDCT-measured coronary artery surface were assessed using linear regression analysis and Spearman's correlation. MDCT and PET/CT were analyzed in all participants. Hemodynamic conditions during CPT at MDCT and PET were similar (P>0.3). Relative changes in coronary artery surface because of CPT (2.0-21.2%) correlated to changes in MBF (-0.10-0.52ml·min(-1)·g(1)) (ρ=0.68, P=0.02). Effective dose was 1.3±0.2mSv for MDCT and 3.1mSv for PET/CT. CONCLUSIONS: Assessment of endothelium-dependent coronary vasoreactivity using MDCT CPT appears feasible. Because of its wider availability, shorter examination time and similar radiation burden, MDCT could be attractive in clinical research for coronary status assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the last two decades, ultrasound (US) has been considered a surrogate for the gold standard in the evaluation of liver fibrosis in schistosomiasis. The use of magnetic resonance imaging (MRI) is not yet standardised for diagnosing and grading liver schistosomal fibrosis. The aim of this paper was to analyse MRI using an adaptation of World Health Organization (WHO) patterns for US assessment of schistosomiasis-related morbidity. US and MRI were independently performed in 60 patients (42.1 ± 13.4 years old), including 37 men and 23 women with schistosomiasis. Liver involvement appraised by US and MRI was classified according to the WHO protocol from patterns A-F. Agreement between image methods was evaluated by kappa index (k). The correlation between US and MRI was poor using WHO patterns [k = 0.14; confidence interval (CI) 0.02; 0.26]. Even after grouping image patterns as "A-D", "Dc-E" and "Ec-F", the correlation between US and MRI remained weak (k = 0.39; CI 0.21; 0.58). The magnetic resonance adaptation used in our study did not confirm US classification of WHO patterns for liver fibrosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Knowledge of the number of recent HIV infections is important for epidemiologic surveillance. Over the past decade approaches have been developed to estimate this number by testing HIV-seropositive specimens with assays that discriminate the lower concentration and avidity of HIV antibodies in early infection. We have investigated whether this "recency" information can also be gained from an HIV confirmatory assay. METHODS AND FINDINGS: The ability of a line immunoassay (INNO-LIA HIV I/II Score, Innogenetics) to distinguish recent from older HIV-1 infection was evaluated in comparison with the Calypte HIV-1 BED Incidence enzyme immunoassay (BED-EIA). Both tests were conducted prospectively in all HIV infections newly diagnosed in Switzerland from July 2005 to June 2006. Clinical and laboratory information indicative of recent or older infection was obtained from physicians at the time of HIV diagnosis and used as the reference standard. BED-EIA and various recency algorithms utilizing the antibody reaction to INNO-LIA's five HIV-1 antigen bands were evaluated by logistic regression analysis. A total of 765 HIV-1 infections, 748 (97.8%) with complete test results, were newly diagnosed during the study. A negative or indeterminate HIV antibody assay at diagnosis, symptoms of primary HIV infection, or a negative HIV test during the past 12 mo classified 195 infections (26.1%) as recent (< or = 12 mo). Symptoms of CDC stages B or C classified 161 infections as older (21.5%), and 392 patients with no symptoms remained unclassified. BED-EIA ruled 65% of the 195 recent infections as recent and 80% of the 161 older infections as older. Two INNO-LIA algorithms showed 50% and 40% sensitivity combined with 95% and 99% specificity, respectively. Estimation of recent infection in the entire study population, based on actual results of the three tests and adjusted for a test's sensitivity and specificity, yielded 37% for BED-EIA compared to 35% and 33% for the two INNO-LIA algorithms. Window-based estimation with BED-EIA yielded 41% (95% confidence interval 36%-46%). CONCLUSIONS: Recency information can be extracted from INNO-LIA-based confirmatory testing at no additional costs. This method should improve epidemiologic surveillance in countries that routinely use INNO-LIA for HIV confirmation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study is part of an ongoing collaborative effort between the medical and the signal processing communities to promote research on applying standard Automatic Speech Recognition (ASR) techniques for the automatic diagnosis of patients with severe obstructive sleep apnoea (OSA). Early detection of severe apnoea cases is important so that patients can receive early treatment. Effective ASR-based detection could dramatically cut medical testing time. Working with a carefully designed speech database of healthy and apnoea subjects, we describe an acoustic search for distinctive apnoea voice characteristics. We also study abnormal nasalization in OSA patients by modelling vowels in nasal and nonnasal phonetic contexts using Gaussian Mixture Model (GMM) pattern recognition on speech spectra. Finally, we present experimental findings regarding the discriminative power of GMMs applied to severe apnoea detection. We have achieved an 81% correct classification rate, which is very promising and underpins the interest in this line of inquiry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We studied human cytomegalovirus (CMV) donor-to-recipient transmission patterns in organ transplantation by analyzing genomic variants on the basis of CMV glycoprotein B (gB) genotyping. METHODS: Organ transplant recipients were included in the study if they had CMV viremia, if they had received an organ from a CMV-seropositive donor, and if there was at least 1 other recipient of an organ from the same donor who developed CMV viremia. Genotypes (gB1-4) were determined by real-time polymerase chain reaction. RESULTS: Forty-seven recipients of organs from 21 donors developed CMV viremia. Twenty-three recipients had a pretransplant donor/recipient (D/R) CMV serostatus of D(+)/R(+), and 24 had a serostatus of D(+)/R(-). The prevalences of genotypes in recipients were as follows: for gB1, 51% (n = 24); for gB2, 19% (n = 9); for gB3, 9% (n = 4); for gB4, 0% (n = 0); and for mixed infection, 21% (n = 10). Recipients of an organ from a common donor had infection with CMV of the same gB genotype in 12 (57%) of 21 instances. Concordance between genotypes was higher among seronegative (i.e., D(+)/R(-)) recipients than among seropositive (D(+)/R(+)) recipients, although discordances resulting from the transmission of multiple strains were seen. In seropositive recipients, transmission of multiple strains from the donor could not be differentiated from reactivation of a recipient's own strains. CONCLUSION: Our analysis of strain concordance among recipients of organs from common donors showed that transmission of CMV has complex dynamic patterns. In seropositive recipients, transmission or reactivation of multiple CMV strains is possible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The skin and appendages is one of the first things in which people repair their social relationships as an alteration of these can influence the image and in multiple aspects of the subject’s life. Psoriasis is a chronic, relapsing skin disease that produces a marked reduction in the quality of life. Phototherapy, especially in form of narrow-band UVB is an alternative treatment of choice in plaque psoriasis and psoriasis of moderate extent. Also, regarding the impact of such treatment on quality of life of patients with psoriasis, there are few studies analyzing this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'objectif de cette étude est de valider une nouvelle grille de codage pour le Lab-TAB (Goldsmith et Rothbart, 1999). Cette grille mesure l'intensité émotionnelle et les comportements de régulation chez l'enfant âgé de six mois. L'accord interjuge se révèle satisfaisant. Les analyses factorielles ont mis en évidence trois facteurs - attention, niveau d'activité et détournement actif - retrouvés dans la littérature comme stratégies de régulation émotionnelle. Les analyses de consistance interne démontrent une bonne homogénéité de ces facteurs. La validité externe se révèle satisfaisante aux niveaux concourant et prédictif. Enfin, cet outil de codage permet de distinguer les prématurés et les nés à terme. L'ensemble de ces résultats indiquent que l'outil élaboré présente de bonnes qualités psychométriques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, pharmaceutical preparations are serious contributors to liver disease; hepatotoxicity ranking as the most frequent cause for acute liver failure and post-commercialization regulatory decisions. The diagnosis of hepatotoxicity remains a difficult task because of the lack of reliable markers for use in general clinical practice. To incriminate any given drug in an episode of liver dysfunction is a step-by-step process that requires a high degree of suspicion, compatible chronology, awareness of the drug's hepatotoxic potential, the exclusion of alternative causes of liver damage and the ability to detect the presence of subtle data that favors a toxic etiology. This process is time-consuming and the final result is frequently inaccurate. Diagnostic algorithms may add consistency to the diagnostic process by translating the suspicion into a quantitative score. Such scales are useful since they provide a framework that emphasizes the features that merit attention in cases of suspected hepatic adverse reaction as well. Current efforts in collecting bona fide cases of drug-induced hepatotoxicity will make refinements of existing scales feasible. It is now relatively easy to accommodate relevant data within the scoring system and to delete low-impact items. Efforts should also be directed toward the development of an abridged instrument for use in evaluating suspected drug-induced hepatotoxicity at the very beginning of the diagnosis and treatment process when clinical decisions need to be made. The instrument chosen would enable a confident diagnosis to be made on admission of the patient and treatment to be fine-tuned as further information is collected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND This paper discusses whether baseline demographic, socio-economic, health variables, length of follow-up and method of contacting the participants predict non-response to the invitation for a second assessment of lifestyle factors and body weight in the European multi-center EPIC-PANACEA study. METHODS Over 500.000 participants from several centers in ten European countries recruited between 1992 and 2000 were contacted 2-11 years later to update data on lifestyle and body weight. Length of follow-up as well as the method of approaching differed between the collaborating study centers. Non-responders were compared with responders using multivariate logistic regression analyses. RESULTS Overall response for the second assessment was high (81.6%). Compared to postal surveys, centers where the participants completed the questionnaire by phone attained a higher response. Response was also high in centers with a short follow-up period. Non-response was higher in participants who were male (odds ratio 1.09 (confidence interval 1.07; 1.11), aged under 40 years (1.96 (1.90; 2.02), living alone (1.40 (1.37; 1.43), less educated (1.35 (1.12; 1.19), of poorer health (1.33 (1.27; 1.39), reporting an unhealthy lifestyle and who had either a low (<18.5 kg/m2, 1.16 (1.09; 1.23)) or a high BMI (>25, 1.08 (1.06; 1.10); especially ≥30 kg/m2, 1.26 (1.23; 1.29)). CONCLUSIONS Cohort studies may enhance cohort maintenance by paying particular attention to the subgroups that are most unlikely to respond and by an active recruitment strategy using telephone interviews.