875 resultados para BLIND EQUALIZERS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper is an elaboration of the DECA algorithm [1] to blindly unmix hyperspectral data. The underlying mixing model is linear, meaning that each pixel is a linear mixture of the endmembers signatures weighted by the correspondent abundance fractions. The proposed method, as DECA, is tailored to highly mixed mixtures in which the geometric based approaches fail to identify the simplex of minimum volume enclosing the observed spectral vectors. We resort then to a statitistical framework, where the abundance fractions are modeled as mixtures of Dirichlet densities, thus enforcing the constraints on abundance fractions imposed by the acquisition process, namely non-negativity and constant sum. With respect to DECA, we introduce two improvements: 1) the number of Dirichlet modes are inferred based on the minimum description length (MDL) principle; 2) The generalized expectation maximization (GEM) algorithm we adopt to infer the model parameters is improved by using alternating minimization and augmented Lagrangian methods to compute the mixing matrix. The effectiveness of the proposed algorithm is illustrated with simulated and read data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To compare the immunogenicity of three yellow fever vaccines from WHO-17D and Brazilian 17DD substrains (different seed-lots). METHODS: An equivalence trial was carried out involving 1,087 adults in Rio de Janeiro. Vaccines produced by Bio-Manguinhos, Fiocruz (Rio de Janeiro, Brazil) were administered following standardized procedures adapted to allow blocked randomized allocation of participants to coded vaccine types (double-blind). Neutralizing yellow fever antibody titters were compared in pre- and post-immunization serum samples. Equivalence was defined as a difference of no more than five percentage points in seroconversion rates, and ratio between Geometric Mean Titters (GMT) higher than 0.67. RESULTS: Seroconversion rates were 98% or higher among subjects previously seronegative, and 90% or more of the total cohort of vaccinees, including those previously seropositive. Differences in seroconversion ranged from -0.05% to -3.02%. The intensity of the immune response was also very similar across vaccines: 14.5 to 18.6 IU/mL. GMT ratios ranged from 0.78 to 0.93. Taking the placebo group into account, the vaccines explained 93% of seroconversion. Viremia was detected in 2.7% of vaccinated subjects from Day 3 to Day 7. CONCLUSIONS: The equivalent immunogenicity of yellow fever vaccines from the 17D and 17DD substrains was demonstrated for the first time in placebo-controlled double-blind randomized trial. The study completed the clinical validation process of a new vaccine seed-lot, provided evidence for use of alternative attenuated virus substrains in vaccine production for a major manufacturer, and for the utilization of the 17DD vaccine in other countries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta publicação contém as comunicações apresentadas no VI Encontro do CIED – I Encontro Internacional em Estudos Educacionais. Avaliação: Desafios e Riscos, nos dias 15 e 16 de novembro de 2013, na Escola Superior de Educação de Lisboa, Instituto Politécnico de Lisboa, organizado pelo CIED, com o apoio da Escola Superior de Educação de Lisboa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The purpose of this study was to investigate effects of different manual techniques on cervical ranges of 17 motion and pressure pain sensitivity in subjects with latent trigger point of the upper trapezius muscle. 18 Methods: One hundred seventeen volunteers, with a unilateral latent trigger point on upper trapezius due to computer 19 work, were randomly divided into 5 groups: ischemic compression (IC) group (n = 24); passive stretching group (n = 20 23); muscle energy technique group (n = 23); and 2 control groups, wait-and-see group (n = 25) and placebo group 21 (n = 22). Cervical spine range of movement was measured using a cervical range of motion instrument as well as 22 pressure pain sensitivity by means of an algometer and a visual analog scale. Outcomes were assessed pretreatment, 23 immediately, and 24 hours after the intervention and 1 week later by a blind researcher. A 4 × 5 mixed repeated- 24 measures analysis of variance was used to examine the effects of the intervention and Cohen d coefficient was used. 25 Results: A group-by-time interaction was detected in all variables (P b .01), except contralateral rotation. The 26 immediate effect sizes of the contralateral flexion, ipsilateral rotation, and pressure pain threshold were large for 3 27 experimental groups. Nevertheless, after 24 hours and 1 week, only IC group maintained the effect size. 28 Conclusions: Manual techniques on upper trapezius with latent trigger point seemed to improve the cervical range of 29 motion and the pressure pain sensitivity. These effects persist after 1 week in the IC group. (J Manipulative Physiol 301 Ther 2013;xx:1-10)