915 resultados para Analytical Documentation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uveal melanoma is a rare but life-threatening form of ocular cancer. Contemporary treatment techniques include proton therapy, which enables conservation of the eye and its useful vision. Dose to the proximal structures is widely believed to play a role in treatment side effects, therefore, reliable dose estimates are required for properly evaluating the therapeutic value and complication risk of treatment plans. Unfortunately, current simplistic dose calculation algorithms can result in errors of up to 30% in the proximal region. In addition, they lack predictive methods for absolute dose per monitor unit (D/MU) values. ^ To facilitate more accurate dose predictions, a Monte Carlo model of an ocular proton nozzle was created and benchmarked against measured dose profiles to within ±3% or ±0.5 mm and D/MU values to within ±3%. The benchmarked Monte Carlo model was used to develop and validate a new broad beam dose algorithm that included the influence of edgescattered protons on the cross-field intensity profile, the effect of energy straggling in the distal portion of poly-energetic beams, and the proton fluence loss as a function of residual range. Generally, the analytical algorithm predicted relative dose distributions that were within ±3% or ±0.5 mm and absolute D/MU values that were within ±3% of Monte Carlo calculations. Slightly larger dose differences were observed at depths less than 7 mm, an effect attributed to the dose contributions of edge-scattered protons. Additional comparisons of Monte Carlo and broad beam dose predictions were made in a detailed eye model developed in this work, with generally similar findings. ^ Monte Carlo was shown to be an excellent predictor of the measured dose profiles and D/MU values and a valuable tool for developing and validating a broad beam dose algorithm for ocular proton therapy. The more detailed physics modeling by the Monte Carlo and broad beam dose algorithms represent an improvement in the accuracy of relative dose predictions over current techniques, and they provide absolute dose predictions. It is anticipated these improvements can be used to develop treatment strategies that reduce the incidence or severity of treatment complications by sparing normal tissue. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effectiveness of the Anisotropic Analytical Algorithm (AAA) implemented in the Eclipse treatment planning system (TPS) was evaluated using theRadiologicalPhysicsCenteranthropomorphic lung phantom using both flattened and flattening-filter-free high energy beams. Radiation treatment plans were developed following the Radiation Therapy Oncology Group and theRadiologicalPhysicsCenterguidelines for lung treatment using Stereotactic Radiation Body Therapy. The tumor was covered such that at least 95% of Planning Target Volume (PTV) received 100% of the prescribed dose while ensuring that normal tissue constraints were followed as well. Calculated doses were exported from the Eclipse TPS and compared with the experimental data as measured using thermoluminescence detectors (TLD) and radiochromic films that were placed inside the phantom. The results demonstrate that the AAA superposition-convolution algorithm is able to calculate SBRT treatment plans with all clinically used photon beams in the range from 6 MV to 18 MV. The measured dose distribution showed a good agreement with the calculated distribution using clinically acceptable criteria of ±5% dose or 3mm distance to agreement. These results show that in a heterogeneous environment a 3D pencil beam superposition-convolution algorithms with Monte Carlo pre-calculated scatter kernels, such as AAA, are able to reliably calculate dose, accounting for increased lateral scattering due to the loss of electronic equilibrium in low density medium. The data for high energy plans (15 MV and 18 MV) showed very good tumor coverage in contrast to findings by other investigators for less sophisticated dose calculation algorithms, which demonstrated less than expected tumor doses and generally worse tumor coverage for high energy plans compared to 6MV plans. This demonstrates that the modern superposition-convolution AAA algorithm is a significant improvement over previous algorithms and is able to calculate doses accurately for SBRT treatment plans in the highly heterogeneous environment of the thorax for both lower (≤12 MV) and higher (greater than 12 MV) beam energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"I don't think we truly understand how to implement. What does it mean to truly implement? Not the command center type that our culture is very good at, but a thorough planned systematic approach" (HP, 9.28.2011). This important question is asked by a clinician who works in a health care setting and who has experienced the implementation of a public policy. This case study applied the lessons learned from three generations of public policy research to a health care setting. As a result of the study an analytical frame was created as a guide to assess an organization's readiness for the implementation of a public policy.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Birth defects are the leading cause of infant mortality in the United States and are a major cause of lifetime disability. However, efforts to understand their causes have been hampered by a lack of population-specific data. During 1990–2004, 22 state legislatures responded to this need by proposing birth defects surveillance legislation (BDSL). The contrast between these states and those that did not pass BDSL provides an opportunity to better understand conditions associated with US public health policy diffusion. ^ This study identifies key state-specific determinants that predict: (1) the introduction of birth defects surveillance legislation (BDSL) onto states' formal legislative agenda, and (2) the successful adoption of these laws. Secondary aims were to interpret these findings in a theoretically sound framework and to incorporate evidence from three analytical approaches. ^ The study begins with a comparative case study of Texas and Oregon (states with divergent BDSL outcomes), including a review of historical documentation and content analysis of key informant interviews. After selecting and operationalizing explanatory variables suggested by the case study, Qualitative Comparative Analysis (QCA) was applied to publically available data to describe important patterns of variation among 37 states. Results from logistic regression were compared to determine whether the two methods produced consistent findings. ^ Themes emerging from the comparative case study included differing budgetary conditions and the significance of relationships within policy issue networks. However, the QCA and statistical analysis pointed to the importance of political parties and contrasting societal contexts. Notably, state policies that allow greater access to citizen-driven ballot initiatives were consistently associated with lower likelihood of introducing BDSL. ^ Methodologically, these results indicate that a case study approach, while important for eliciting valuable context-specific detail, may fail to detect the influence of overarching, systemic variables, such as party competition. However, QCA and statistical analyses were limited by a lack of existing data to operationalize policy issue networks, and thus may have downplayed the impact of personal interactions. ^ This study contributes to the field of health policy studies in three ways. First, it emphasizes the importance of collegial and consistent relationships among policy issue network members. Second, it calls attention to political party systems in predicting policy outcomes. Finally, a novel approach to interpreting state data in a theoretically significant manner (QCA) has been demonstrated.^

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: