Background: Prior to the launch of silcone hydrogel (Si-H) materials in Australia in 1999, only 1.6 per cent of lenses were prescribed on a continuous wear basis.

Methods: One thousand surveys were distributed randomly to practitioners in Australia during January 2000, 2001 and 2002 (total surveys 3,000). Each anonymous survey requested data about the next 10 patients fitted with contact lenses, including date, age, gender, new fitting or refitting, lens material type, lens design, frequency of replacement, modality of wear, uses per week and care regimen.

Results: Twenty per cent (599) were returned, reporting data on 5,976 fittings. A total of 710 fittings used Si-H contact lenses (11.9 per cent), which represented 18.6 per cent of all soft lens fittings. During the three years, the proportion of practitioners prescribing Si-H lenses increased from 42.2 to 52.5 per cent. In 2000, 43.8 per cent were daily wear, which decreased to 32.2 per cent by 2002. The solution system of choice for daily wear lenses was multipurpose solutions (98.4 per cent); the only alternative was hydrogen peroxide systems. Continuous wear represented 11.7 per cent of all fittings, ofwhich 85.7 per cent were Si-H, 3.0 per cent RGP lenses and 11.3 per cent conventional hydrogels. For continuous wear, 79.0 per cent of fittings were to existing wearers, whereas for daily wear, 59.4 per cent were existing wearers. More males were prescribed Si-H continuous wear contact lenses, while females were more likely to be prescribed Si-H on a daily wear basis.

Discussion: Si-H contact lenses were introduced to the Australian market as a continuous wear contact lens, yet many practitioners use this product for daily wear with multipurpose solutions. By 2002, more practitioners were prescribing Si-H contact lenses for continuous wear than in 2000, suggesting a growing confidence in that product for that mode of wear. A comparison with an earlier survey shows there is an increase in continuous wear from 1.6 per cent to 11.7 per cent over a five-year period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This study was conducted to ascertain current preferences for contact lens prescribing in the Australian states and territories.

Methods: One thousand questionnaires were randomly distributed to proportionate samples of optometrists in each state of Australia. We requested details of the first 10 patients fitted with contact lenses after receipt of the questionnaire.

Results: One hundred and seventy-eight completed questionnaires were returned, detailing contact lens fits to 1,611 patients. The mean age of the patient group was 32.1 $pL 13.0 yrs (65 per cent female). For Australia as a whole: 53 per cent of patients were existing wearers, the remainder were new fits; 93 per cent of new fits were with soft lenses, of which seven per cent were for extended wear. Of the refits, 89 per cent were soft lenses and 18 per cent for extended wear. The lens material of first choice was mid-water-content (62 per cent of all soft lens fits). Only eight per cent of all soft fits were for lenses that were not replaced on a planned basis, with two weeks being the replacement interval of choice in all states and territories. The majority of rigid lenses were prescribed using mid-Dk materials (50 per cent). Analysis of solution prescribing indicates that multi-purpose products were the most common regimens for planned replacement soft lenses. The percentage of hydrogen peroxide prescribed increased as lens replacement became less frequent. By state or territory: practitioners in Tasmania prescribed more extended wear than those in any other state (p = 0.007) and practitioners in Queensland prescribed more daily disposable contact lenses than those in any other state (p = 0.009).

Conclusions: Non-planned replacement lenses are now rarely prescribed to patients. Extended-wear lenses and rigid lenses continue to be prescribed more to existing contact lens wearers than to new patients. The impact of soft multifocal lens designs on contact lens prescribing is very small, ranging from 2.6 per cent in Queensland to 4.7 per cent in Victoria, despite 20 per cent of patients being more than 45 years of age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:This study was conducted to ascertain current modes of contact lens prescribing in Australia.

Methods:One thousand questionnaires were randomly distributed to proportionate samples of optometrists in each state of Australia. The profession fits the majority of contact lenses in Australia and the sample represents 55 per cent of all optometrists. We requested details of the first 10 patients fitted with contact lenses after receipt of the questionnaire.

Results:We received 224 completed questionnaires, detailing contact lens fits to 2,230 patients. The mean age of the patient group was 32.3 ± 12.9 years and 65 per cent of these were female. Sixty per cent of patients were existing wearers, the remainder being new fits. The data indicated that 94 per cent of new fits were with soft lenses, of which six per cent were for extended wear. For refits 83 per cent were soft lenses and 24 per cent were extended wear. It was clear that the lens of first choice was mid-water-content (52 per cent of all soft lens fits). Only nine per cent of all soft fits were for lenses which were not replaced on a planned basis. The majority of rigid lenses were prescribed using mid-Dk materials (71 per cent). Analysis of solution prescribing indicates that multipurpose products were the most common regimens for planned replacement soft lenses. The percentage of hydrogen peroxide prescribed increased as lens replacement became less frequent.

Conclusions:Non-planned replacement lenses are now rarely prescribed to patients. Extended wear lenses and rigid lenses are prescribed more to existing contact lens wearers. The impact of multifocal lens designs on contact lens prescribing is very small, namely, five per cent of soft contact lenses and eight per cent of rigid lenses, despite 20 per cent of patients being over 45 years of age.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To review the effects of contact lenses on the corneal surface.

Methods: A review of the literature and in-house research of corneal staining and its various forms of presentation.

Results: Corneal staining manifests in many different forms. The severity of staining or insult of the cornea is usually determined by the extent (area of coverage), density, and depth. The cause of staining is multifactorial, and its location is often linked to the type of lens that is being worn, the solution used to clean/disinfect the lens, the state of hydration of the soft lens, and the state of the cornea that has been affected by the lens.

Conclusions: Sodium fluorescein dye effectively highlights corneal integrity changes referred to as corneal staining. This review describes the manifestations, the cause, the mechanisms, and the methods of remediation of corneal staining.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Tear meniscus height (TMH) is an indirect measurement of tear film volume. This study investigated the temporal changes in the TMH during the blink interval in the morning (8–9 am) and at the end of the day (5–6 pm) in both soft contact lens (CL) and nonlens wearers (NLW).

Methods: Fifty participants (25 CL; 25 NLW) were evaluated for their subjective symptoms, TMH, noninvasive break up time, and bulbar hyperemia at the am and pm visits on the same day. The TMH was measured at set intervals between 2 and 15 sec during the blink interval, using an optical coherence tomographer.

Results: The NLW group revealed no changes in a variety of symptoms during the day, whereas the CL group reported an increase in dryness (P=0.03) and grittiness (P=0.02) over the day. For both groups, the TMH and calculated tear meniscus volume revealed lower values immediately after the blink and increased progressively afterwards, mainly due to reflex tearing. The am tear meniscus volume values tended to be higher than the pm values for both groups, but this was not significant (NLW P=0.13; CL P=0.82). Noninvasive break up time deteriorated during the day for both groups but was only significant for the CL group (P=0.002), whereas bulbar hyperemia revealed no statistically significant change for either group.

Conclusions: Reflex tearing may play a substantial role in the TMH differences observed over the blink interval. Standardization of the time when a TMH measurement is performed will be valuable in comparing tear film clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether the refractive index (RI) of a soft contact lens can be evaluated using refractometry while the lens remains on the eye and to compare this with more traditional ex vivo RI measurements.

Methods: A slitlamp apparatus was modified to incorporate a customized Atago hand refractometer. With a double-masked study design, nine adapted symptomatic soft contact lens wearers wore a contact lens in each eye (lotrafilcon B and etafilcon A) in a randomized order. In vivo RI was determined from the relative Brix scale measurements immediately after lens insertion and after 1 and 10 hr of lens wear. Ex vivo refractometry was performed after 10 hr of lens wear for comparison. Means ± standard errors of the means are reported.

Results: In vivo RI values at baseline were 1.422 ± 0.0004 (lotrafilcon B) and 1.405 ± 0.0021 (etafilcon A); after 1 hr of lens wear, values were 1.423 ± 0.0006 and 1.408 ± 0.0007, respectively; and after 10 hr of lens wear, values were 1.424 ± 0.0004 and 1.411 ± 0.0010, respectively. Ex vivo RI values at the end of the 10 hr wearing period were 1.424 ± 0.0003 (lotrafilcon B) and 1.412 ± 0.0017 (etafilcon A). The change in in vivo RI across the day was statistically significant for the etafilcon A lens (repeated-measures analysis of variance, P<0.01) but not for the lotrafilcon B lens (P>0.05).

Conclusions: This novel adaptation of refractometry was able to measure the RI of soft contact lenses during wear (without lens removal). End of day RI measurements using in vivo and ex vivo refractometry were comparable with each other. Future work is required to determine whether this in vivo method can improve our understanding of the relationships between soft contact lens RI, hydration, on-eye lens performance, and symptomology.