947 resultados para Adsorption
Resumo:
The mechanism of generation of atomic Na and K from SiO2 samples has been studied using explicitly correlated wave function and density functional theory cluster calculations. Possible pathways for the photon and electron stimulated desorption of Na and K atoms from silicates are proposed, thus providing new insight on the generation of the tenuous Na and K atmosphere of the Moon.
Resumo:
Recent experiments of H2 adsorption on Pd(111) [T. Mitsui et al., Nature (London) 422, 705 (2003)] have questioned the classical Langmuir picture of second order adsorption kinetics at high surface coverage requiring pairs of empty sites for the dissociative chemisorption. Experiments find that at least three empty sites are needed. Through density functional theory, we find that H2 dissociation is favored on ensembles of sites that involve a Pd atom with no direct interaction with adsorbed hydrogen. Such active sites are formed by aggregation of at least 3 H-free sites revealing the complex structure of the "active sites."
Resumo:
Due to their numerous novel technological applications ranging from the example of exhaust catalysts in the automotive industry to the catalytic production of hydro- gen, surface reactions on transition metal substrates have become to be one of the most essential subjects within the surface science community. Although numerous applications exist, there are many details in the different processes that, after many decades of research, remain unknown. There are perhaps as many applications for the corrosion resistant materials such as stainless steels. A thorough knowledge of the details of the simplest reactions occuring on the surfaces, such as oxidation, play a key role in the design of better catalysts, or corrosion resistant materials in the future. This thesis examines the oxidation of metal surfaces from a computational point of view mostly concentrating on copper as a model material. Oxidation is studied from the initial oxidation to the oxygen precovered surface. Important parameters for the initial sticking and dissociation are obtained. The saturation layer is thoroughly studied and the calculated results arecompared with available experimental results. On the saturated surface, some open questions still remain. The present calculations demonstrate, that the saturated part of the surface is excluded from being chemically reactive towards the oxygen molecules. The results suggest, that the reason for the chemical activity of the saturated surface is due to a strain effect occuring between the saturated areas of the surface.
Resumo:
Streptavidin, a tetrameric protein secreted by Streptomyces avidinii, binds tightly to a small growth factor biotin. One of the numerous applications of this high-affinity system comprises the streptavidin-coated surfaces of bioanalytical assays which serve as universal binders for straightforward immobilization of any biotinylated molecule. Proteins can be immobilized with a lower risk of denaturation using streptavidin-biotin technology in contrast to direct passive adsorption. The purpose of this study was to characterize the properties and effects of streptavidin-coated binding surfaces on the performance of solid-phase immunoassays and to investigate the contributions of surface modifications. Various characterization tools and methods established in the study enabled the convenient monitoring and binding capacity determination of streptavidin-coated surfaces. The schematic modeling of the monolayer surface and the quantification of adsorbed streptavidin disclosed the possibilities and the limits of passive adsorption. The defined yield of 250 ng/cm2 represented approximately 65 % coverage compared with a modelled complete monolayer, which is consistent with theoretical surface models. Modifications such as polymerization and chemical activation of streptavidin resulted in a close to 10-fold increase in the biotin-binding densities of the surface compared with the regular streptavidin coating. In addition, the stability of the surface against leaching was improved by chemical modification. The increased binding densities and capacities enabled wider high-end dynamic ranges in the solid-phase immunoassays, especially when using the fragments of the capture antibodies instead of intact antibodies for the binding of the antigen. The binding capacity of the streptavidin surface was not, by definition, predictive of the low-end performance of the immunoassays nor the assay sensitivity. Other features such as non-specific binding, variation and leaching turned out to be more relevant. The immunoassays that use a direct surface readout measurement of time-resolved fluorescence from a washed surface are dependent on the density of the labeled antibodies in a defined area on the surface. The binding surface was condensed into a spot by coating streptavidin in liquid droplets into special microtiter wells holding a small circular indentation at the bottom. The condensed binding area enabled a denser packing of the labeled antibodies on the surface. This resulted in a 5 - 6-fold increase in the signal-to-background ratios and an equivalent improvement in the detection limits of the solid-phase immunoassays. This work proved that the properties of the streptavidin-coated surfaces can be modified and that the defined properties of the streptavidin-based immunocapture surfaces contribute to the performance of heterogeneous immunoassays.
Resumo:
Antibiootit ovat yleisessä käytössä olevia lääkeaineita, joilla on kyky hidastaa mikrobien kasvua. Osa lääkeaineesta poistuu elimistöstä muuntumattomana. Koska tavanomainen jäteveden käsittelyprosessi ei riitä poistamaan antibiootteja jätevedestä, ne päätyvät vesistöihin, joissa ne häiritsevät ekosysteemiä ja voivat aiheuttaa vastustuskykyisten bakteerikantojen muodostumisen. Antibiootit voitaisiin poistaa vedestä adsorptiolla. Työssä on esitelty antibioottien adsorptiomekanismeja, vedenkäsittelyssä käytettäviä adsorptioprosesseja ja adsorbentteja, jotka soveltuvat antibioottien erottamiseen vedestä. Lisäksi tarkastellaan yleisesti adsorption kinetiikkaa ja termodynamiikkaa sekä mallinnetaan panoskokeiden tulosten perusteella jatkuvatoimisen adsorptiokolonnin toimintaa.
Resumo:
Työssä tutkittiin laboratorio-olosuhteissa germaniumin talteenottoa happamista hydrometallurgisista sulfaattiliuoksista käyttäen kaupallisia ioninvaihtohartseja. Germaniumin talteenottoa tutkittiin sekä tasapaino- että kolonnikokein syöttöliuoksista joiden pH oli alueella 0,8–3,0. Tutkituista hartseista parhaiten germanium voitiin erottaa käyttäen emäsmuotoista N-metyyli-D-glukamiini-tyyppistä ioninvaihtohartsia (esim. Rohm & Haasin IRA-743). Germaniumille määritettiin adsorptioisotermit tasapainokokein sekä emäs- että happomuotoisilla hartseilla. Adsorptioisotermien perusteella parhaiten germa-niumia adsorboi emäsmuotoinen IRA-743-hartsi kun liuoksen alku-pH oli tutkitun alueen korkein. Lämpötilassa 25 °C kapasiteetti oli 114 mg Ge/g. Tasapainokokein määritettiin emäsmuotoisilla hartseilla germaniumin lisäksi myös kuparia ja kobolttia sisältävillä liuoksilla Ge:n jakaantumisvakiot sekä erotustekijät Ge/Cu ja Ge/Co. Havaittiin, että IRA-743:lla alku-pH:ssa 3,0 Ge:n jakaantumisvakiot sekä erotustekijät Ge/Cu ja Ge/Co olivat selvästi suuremmat kuin muilla tutkituilla hartseilla. Arseenin, nikkelin, sinkin ja rauta(III):n adsorboitumista emäsmuotoiseen IRA-743:een tutkittiin monimetallisella liuoksella syöttöliuoksen pH:n ollessa alueella 1,4–3,6. Kokeissa havaittiin, että hartsi adsorboi hieman Ni:a ja Zn:a tasapaino-pH:n ollessa yli 5,5. Arseenia ei tutkitulla pH-alueella havaittu adsorboituvan. Lisäksi huomattiin, että rauta alkaa saostua pH:n ollessa hieman alle kolme. Kolonnikokeissa havaittiin, että emäsmuotoinen IRA-743-hartsi toimii hyvin germaniumin talteenotossa myös kolonnissa. Pelkästään germaniumia ja kobolttia sisältäneellä liuoksella hartsin dynaamiseksi kapasiteetiksi saatiin 54 mg Ge/g. Germaniumin eluointi IRA-743:sta onnistui parhaiten 0,5 M H2SO4:lla. Kolonnikokeita IRA-743:lla ajettiin myös monimetallisilla liuoksilla, mutta silloin havaittiin hartsin kapasiteetin pienenevän hartsin myrkyttymisen takia.
Resumo:
There is an increasing interest to seek new enzyme preparations for the development of new products derived from bioprocesses to obtain alternative bio-based materials. In this context, four non-commercial lipases from Pseudomonas species were prepared, immobilized on different low-cost supports, and examined for potential biotechnological applications. Results: To reduce costs of eventual scaling-up, the new lipases were obtained directly from crude cell extracts or from growth culture supernatants, and immobilized by simple adsorption on Accurel EP100, Accurel MP1000 and Celite (R) 545. The enzymes evaluated were LipA and LipC from Pseudomonas sp. 42A2, a thermostable mutant of LipC, and LipI. 3 from Pseudomonas CR611, which were produced in either homologous or heterologous hosts. Best immobilization results were obtained on Accurel EP100 for LipA and on Accurel MP1000 for LipC and its thermostable variant. Lip I. 3, requiring a refolding step, was poorly immobilized on all supports tested ( best results for Accurel MP1000). To test the behavior of immobilized lipases, they were assayed in triolein transesterification, where the best results were observed for lipases immobilized on Accurel MP1000. Conclusions: The suggested protocol does not require protein purification and uses crude enzymes immobilized by a fast adsorption technique on low-cost supports, which makes the method suitable for an eventual scaling up aimed at biotechnological applications. Therefore, a fast, simple and economic method for lipase preparation and immobilization has been set up. The low price of the supports tested and the simplicity of the procedure, skipping the tedious and expensive purification steps, will contribute to cost reduction in biotechnological lipase-catalyzed processes.
Resumo:
All the experimental part of this final project was done at Laboratoire de Biotechnologie Environnementale (LBE) from the École Polytechnique Fédérale de Lausanne (EPFL), Switzerland, during 6 months (November 2013- May 2014). A fungal biofilter composed of woodchips was designed in order to remove micropollutants from the effluents of waste water treatment plants. Two fungi were tested: Pleurotus ostreatus and Trametes versicolor in order to evaluate their efficiency for the removal of two micropollutants: the anti-inflammatory drug naproxen and the antibiotic sulfamethoxazole,. Although Trametes versicolor was able to degrade quickly naproxen, this fungus was not any more active after one week of operation in the filter. Pleurotus ostreatus was, on contrary, able to survive more than 3 months in the filter, showing good removal efficiencies of naproxen and sulfamethoxazole during all this period, in tap water but also in real treated municipal wastewater. Several other experiments have provided insight on the removal mechanisms of these micropollutants in the fungal biofilter (degradation and adsorption) and also allowed to model the removal trend. Fungal treatment with Pleurotus ostreatus grown on wood substrates appeared to be a promising solution to improve micropollutants removal in wastewater.
Resumo:
Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L−1 range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels
Resumo:
A simple chemical method has been developed to quantify the silanol groups (º Si-OH) in silica as well as in coated chromatographic supports for use in packed - column Gas Chromatography. After adsorption of 10 mg/mL methylene blue, centrifuging action and filtration, the absorbance of the solution was inversely proportional to the silanol quantity. The difference between the absorbance of the pure solution and that of the solid - free filtrate was related to the silica weight, yielding a quantitative analysis of these groups.
Resumo:
Nanocomposites obtained by the encapsulation of conducting polymers such as polyaniline and polydiphenylamine in 2H-MoS2 and 1T-TiS2 are synthesized and characterized by X-ray diffraction and infrared spectrophotometry. The synthesis consists in intercalating the layered compound with n-butyllithium and subsequent exfoliation in water and organic solvents. The nanocomposites are obtained by the adsorption of the polymers into the single-layers sulfides and posterior restacking. The X-ray diffraction measurements showed that the organic conducting polymers are encapsulated in mono and bilayers arrangement in a well-ordered fashion to produce single phase compounds.
Resumo:
This article introduces a simplified model for the theoretical study of the physical adsorption process of gaseous He on the planes (100) and (111) of the solid Xe matrix, whose crystalline structure is face centered cubic (fcc). The Ab initio calculations were carried out at the MP2 level of theory employing basis sets obtained through the Generator Coordinate Method, where the core electrons were represented by a pseudopotential. The calculated adsorption energies for the (100) and (111) faces are 5,39 and 4,18 kJ/mol, respectively. This simplified model is expected to be suitable for treating complex systems of applied interest.
Resumo:
The physical and chemical characterization of vermicompost from bovine manure has been studied. It was examined the pH and cation exchangeable capacity (CEC), organic matter content, electric conductivity and elementary and XRD analyses, among other characteristics. The vermicompost was then applied to the retention and competition of metal micronutrients and pollutants (Cu and Zn) from metal nitrate solutions. The retention was affected by both the pH and adsorption time, while the competitive character of these metals for the substrate was relevant to each pH examined.
Resumo:
Adsorption of Cu(II), Ni(II), Pb(II) and Zn(II) ions from aqueous solutions by N-(3,4-dihydroxybenzyl) chitosan have been carried out. The Langmuir (L), Freundlich (F), Langmuir - Freundlich (LF), Redlich-Peterson (RP) and Tóth (T) adsorption isotherms models have been applied to fit the experimental data. Nonlinear regression computational program "Enzefitte", which is a library of the more commonly used adsorption isotherm equations for obtaining tabular outuput suitable for plotting theoretical of fitted isotherms, has been used to estimate the adsorption parameters. These parameters were used to calculate the amount adsorbed q calc., a function of concentration (C).
Resumo:
X-This work shows an alternative method to copper determination by X-Ray Fluorescence (XRF). Since copper concentration in natural waters is not enough to reach XRF detection limit, a liquid-solid preconcentration procedure was proposed. Glycerin was used to complex the metal increasing its adsorption on activated charcoal. The solid phase was used to XRF determination. Several parameters were evaluated, such as, the complexation pH, the charcoal adsorption limit and the glycerin concentration. The interferences are lead and bismuth and the sensitivities decreased in the order Cu2+, Bi3+ and Pb2+. The advantages of the method are its simplicity, low cost and low spectral interference.