971 resultados para ACCRETION, ACCRETION DISKS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The CLSI M100-S19 document has recommended the disuse of vancomycin disks for staphylococci and informed that studies on the action of teicoplanin in disk-diffusion testing should be performed. We describe the comparison of two methods, disk diffusion and broth microdilution, for determining teicoplanin susceptibility in clinical isolates of staphylococci. Overall results showed an aggregation rate of 96.8%; Staphylococcus aureus showed total agreement while S. epidermidis showed 93.8% of agreement. According to these local results, disk diffusion can still be employed to teicoplanin susceptibility determination for staphylococci in our institution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The total number and distribution per antennal flagellomere of sensilla placodea (olfactory disks), sensilla coeloconica, sensilla ampullacea and sensilla campaniformia were determined in workers of Nannotrigona testaceicornis Lepeletier a stingless bee species quite common in Brazil. The distribution of the sensilla was uniform, with the largest number occurring in flagellomere 10 and gradually decreasing in the direction of the basal flagellomeres in a way similar to that observed in Scaptotrigona postica Latreille.Nannotrigona testaceicornis had a larger number of sensilla ampullacea and a smaller number of sensilla coeloconica and sensilla campaniformia than Scaptotrigona postica. Although Nan notrigona testaceicornis does not communicate through the formation of pheromone trails, this species presents a larger quantity of sensilla placodea (relative to the length of the flagellum) than Scaptotrigona postica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Statement of problem. Different combinations of Co-Cr alloys bonded to ceramic have been used in dentistry; however, the bond strength of ceramic to metal can vary because of different compositions of these alloys.Purpose. The purpose of this study was to evaluate the shear bond strength of a dental ceramic to 5 commercially available Co-Cr alloys.Material and methods. Five Co-Cr alloys (IPS d.SIGN 20, IPS d.SIGN 30, Remanium 2000, Heranium P, and Wirobond C) were tested and compared to a control group of an Au-Pd alloy (Olympia). Specimen disks, 5 mm high and 4 mm in diameter, were fabricated with the lost-wax technique. Sixty specimens were prepared using opaque and dentin ceramics (VITA Omega 900), veneered, 4 mm high and 4 mm in diameter, over the metal specimens (n = 10). The shear bond strength test was performed in a universal testing machine with a crosshead speed of 0.5 mm/min. After shear bond testing, fracture surfaces were evaluated in a stereomicroscope under x25 magnification. Ultimate shear bond strength (MPa) data were analyzed with 1-way ANOVA and the Tukey HSD test (alpha = .05).Results. The mean (SID) bond strengths (MPa) were: 61.4 (7.8) for Olympia; 94.0 (18.9) for IPS 20; 96.8 (10.2) for I PS 30; 75.1 (12.4) for Remanium; 71.2 (14.3) for Heranium P; and 63.2 (10.9) for Wirobond C. Mean bond strengths for IPS 20 and IPS 30 were not significantly different, but were significantly (P<.001) higher than mean bond strengths for the other 4 alloys, which were not significantly different from each other.Conclusions. Bond strength of a dental ceramic to a Co-Cr alloy is dependent on the alloy composition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: This study evaluated the surface hardness of a resin cement (RelyX ARC) photoactivated through indirect composite resin (Cristobal) disks of different thicknesses using either a light- emitting diode (LED) or quartz tungsten halogen (QTH) light source. Material and Methods: Eighteen resin cement specimens were prepared and divided into 6 groups according to the type of curing unit and the thickness of resin disks interposed between the cement surface and light source. Three indentations (50 g for 15 s) were performed on the top and bottom surface of each specimen and a mean Vickers hardness number (VHN) was calculated for each specimen. The data were analyzed using two-way ANOVA and Tukey-Kramer test was used for post-hoc pairwise comparisons. Results: Increased indirect resin disk thickness resulted in decreased mean VHN values. Mean VHN values for the top surfaces of the resin cement specimens ranged from 23.2 to 46.1 (QTH) and 32.3 to 41.7 (LED). The LED curing light source produced higher hardness values compared to the QTH light source for 2- and 3-mm-thick indirect resin disks. The differences were clinically, but not statistically significant. Increased indirect resin disk thickness also resulted in decreased mean VHN values for the bottom surfaces of the resin cement: 5.8 to 19.1 (QTH) and 7.5 to 32.0 (LED). For the bottom surfaces, a statistically significant interaction was also found between the type of curing light source and the indirect resin disk thickness. Conclusions: Mean surface hardness values of resin cement specimens decreased with the increase of indirect resin disk thickness. The LED curing light source generally produced higher surface hardness values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study tested the bond strength of a resin cement to a glass-infiltrated zirconia-alumina ceramic after three conditioning methods and using two test methods (shear-SBS versus microtensile-MTBS). Ceramic blocks for MTBS and ceramic disks for SBS were fabricated. Three surface conditioning (SC) methods were evaluated: (1) 110-mu m Al(2)O(3)+Silanization; (2) Chairside silica coating+silanization: (3) Laboratory silica coating+silanization. Following surface conditioning, the resin cement (Panavia F) was bonded to the conditioned ceramics. Although no statistically significant differences (p=0.1076) were seen between the test methods, results yielded with the different surface conditioning methods showed statistically significant differences (p<0.0001) (SC2=SC3>SC1.). As for the interaction between the factors, two-way ANOVA showed that it was not statistically significant (p=0.1443). MTBS test resulted in predominantly mixed failure (85%), but SBS test resulted in exclusively adhesive failure. on the effects of different surface conditioning methods, chairside and laboratory tribochemical silica coating followed by silanization showed higher bond strength results compared to those of aluminum oxide abrasion and silanization, independent of the test method employed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The complete I-V characteristics of SnO(2)-based varistors, particularly of the Pianaro system SCNCr consisting in 98.9%SnO(2)+1%CoO+0.05%Nb(2)O(5)+0.05%Cr(2)O(3), all in mol%, have been seldom reported in the literature. A comparative study at low and high currents of the nonohmic behavior of SCNCr- and ZnO-based varistors (modified Matsuoka system) is proposed in this work. The SCNCr system showed higher nonlinearity coefficients in the whole range of measured current. The electrical breakdown field (E(b)) was twice as high for the SCNCr system (5400 V/cm) than for the ZnO varistor (2600 V/cm) due to a smaller average grain size of the former (4.5 mu m) with respect to the latter (8.5 mu m). Nevertheless, we consider that another important factor responsible for the high E(b) in the SCNCr system is the great number of electrically active interfaces (85%) as determined with electrostatic force microscopy (EFM). It was also established that the SCNCr system might be produced in disks of smaller dimensions than that of commercial ZnO-based product, with a 5.0 cm(-1) minimal area-volume (A/V) ratio. The SCNCr reached the saturation current in a short time because of the high resistivity of the grains, which is five times higher than that of the grains in ZnO-based varistors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aproximadamente, 15% das discopatias em cães acometem a região cervical, sendo a dor o principal sinal clínico. Descreve-se a ocorrência de protrusão de disco cervical em 17 cães, agrupados segundo a raça, sexo, peso, idade, assim como a distribuição quanto à duração dos sintomas, acometimento dos discos intervertebrais (DIV), tempo de recuperação e porcentagem de sucesso, em relação à condição neurológica presente antes da cirurgia. A raça Dachshund representou 29,5% (n=5), cães sem raça definida, Poodle e Cocker Spaniel Inglês, 17,6% cada (n=9), Pinscher, 11,8% (n=2) e Dálmata, 5,9% (n=1). Destes, 58,8% eram machos (n=10) e 41,2%, fêmeas (n=7), com peso entre 2 e 29kg, e idade média igual a 5,8 anos. O quadro neurológico desses animais correspondia à dor e ataxia, com exceção de um cão Dálmata, 11 anos de idade, que apresentava tetraparesia. A duração dos sinais variou de 2 a 90 dias. Os DIV mais acometidos foram C2/3 (40%), C3/4 (25%), C4/5 (15%), C5/6 (10%) e C6/7 (10%), sendo que alguns animais apresentavam lesões múltiplas. O procedimento foi padrão para todos os animais, através da fenestração e curetagem de todos os DIV abordados pelo acesso ventral, ou seja, de C2/3 até C6/7, empregando-se para isso instrumental usado para remoção de tártaro dentário (curetas Gracey, curetas McCall, extratores de tártaro S.S.White e McCall). O tempo médio de recuperação foi de 9 a 38 dias, sendo que 100% deles recuperaram totalmente as funções neurológicas. Conclui-se que a fenestração ventral apresenta excelentes resultados no tratamento das discopatias cervicais, desde que bem selecionados os pacientes, inclusive, com respeito aos diagnósticos diferenciais.