991 resultados para 140.3480
Resumo:
Quality of cardiopulmonary resuscitation (CPR) improves through the use of CPR feedback devices. Most feedback devices integrate the acceleration twice to estimate compression depth. However, they use additional sensors or processing techniques to compensate for large displacement drifts caused by integration. This study introduces an accelerometer-based method that avoids integration by using spectral techniques on short duration acceleration intervals. We used a manikin placed on a hard surface, a sternal triaxial accelerometer, and a photoelectric distance sensor (gold standard). Twenty volunteers provided 60 s of continuous compressions to test various rates (80-140 min(-1)), depths (3-5 cm), and accelerometer misalignment conditions. A total of 320 records with 35312 compressions were analysed. The global root-mean-square errors in rate and depth were below 1.5 min(-1) and 2 mm for analysis intervals between 2 and 5 s. For 3 s analysis intervals the 95% levels of agreement between the method and the gold standard were within -1.64-1.67 min(-1) and -1.69-1.72 mm, respectively. Accurate feedback on chest compression rate and depth is feasible applying spectral techniques to the acceleration. The method avoids additional techniques to compensate for the integration displacement drift, improving accuracy, and simplifying current accelerometer-based devices.
Resumo:
Ichthyoplankton surveys have been used to provide an independent estimate of adult spawning biomass of commercially exploited species and to further our understanding of the recruitment processes in the early life stages. However, predicting recruitment has been difficult because of the complex interaction of physical and biological processes operating at different spatial and temporal scales that can occur at the different life stages. A model of first-year life-stage recruitment was applied to Georges Bank Atlantic cod (Gadus morhua) and haddock (Melanogrammus aeglefinus) stocks over the years 1977–2004 by using environmental and densitydependent relationships. The best lifestage mortality relationships for eggs, larvae, pelagic juveniles, and demersal juveniles were first determined by hindcasting recruitment estimates based on egg and larval abundance and mortality rates derived from two intensive sampling periods, 1977–87 and 1995–99. A wind-driven egg mortality relationship was used to estimate losses due to transport off the bank, and a wind-stress larval mortality relationship was derived from feeding and survival studies. A simple metric for the density-dependent effects of Atlantic cod was used for both Atlantic cod and haddock. These life stage proxies were then applied to the virtual population analysis (VPA) derived annual egg abundances to predict age-1 recruitment. Best models were determined from the correlation of predicted and VPA-derived age-1 abundance. The larval stage was the most quantifiable of any stage from surveys, whereas abundance estimates of the demersal juvenile stage were not available because of undersampling. Attempts to forecast recruitment from spawning stock biomass or egg abundance, however, will always be poor because of variable egg survival.
Resumo:
Nivel educativo: Grado. Duración (en horas): De 21 a 30 horas
Resumo:
Stock assessments can be problematic because of uncertainties associated with the data or because of simplified assumptions made when modeling biological processes (Rosenberg and Restrepo, 1995). For example, the common assumption in stock assessments that stocks are homogeneous and discrete (i.e., there is no migration between the stocks) is not necessarily true (Kell et al., 2004a, 2004b).
Resumo:
Se han estudiado las propiedades magnéticas y magnetoimpedancia gigante de las películas delgadas de base de FeNi/Ti depositadas sobre sustratos de vidrio y COC sin/con tratamiento térmico utilizando el Efecto Magneto Óptico de Kerr, VSM y espectroscopia de MI. Se han conseguido resultados interesantes: a) Para la muestra depositada sobre sustrato de vidrio se obtuvo una GMI máxima de un 145% en 64 MHz, mientras que la depositada sobre COC presentó una GMI máxima de 89% en 97 MHz; b) La sensibilidad aumentó de 17%/Oe (a 140 MHz) a 22 %/Oe (a 87 MHz), lo cual mejoró el punto de operación del sensor GMI flexible. Estos resultados confirman la utilidad del sistema de recocido diseñado.
Resumo:
A total of 140 sets of parameters (a and b) of the length-weight relationships (LWR) of the form W=aL super(b) are presented for fishes caught in Cuban waters. These parameters cover 94 species of fish belonging to 43 families. Most of the parameters were compiled from 107 sets of published and unpublished studies. Twenty-five sets of parameters were from personal communications through colleagues in Cuba, while the remaining eight sets were estimated by the authors from unpublished data.
Resumo:
A apneia obstrutiva do sono (AOS) é considerada um fator de risco independente para as doenças cardiovasculares. Existem evidências de que indivíduos com apneia obstrutiva do sono podem apresentar elevação nos mediadores inflamatórios, alterações no perfil metabólico, aumento na atividade do sistema nervoso simpático, com consequente elevação da pressão arterial e disfunção endotelial. Nos últimos anos, inúmeros estudos tem apontado a AOS como um dos fatores responsáveis pela hipertensão resistente. O objetivo do estudo foi avaliar a presença da apneia obstrutiva do sono e o comportamento da função endotelial em pacientes com hipertensão resistente, comparando com hipertensos apresentando pressão arterial controlada com até 3 classes diferentes de fármacos anti-hipertensivos. Trata-se de um estudo transversal com 40 pacientes hipertensos: 20 com hipertensão arterial resistente (HAR) e 20 com pressão arterial controlada por medicação (hipertensão arterial controlada; HAC), sem distinção de raça ou gênero, com idade entre 18 e 75 anos. A pressão arterial casual e a monitorização ambulatorial da pressão arterial foram aferidas por método oscilométrico em aparelhos automáticos. A função endotelial e a presença da apneia obstrutiva do sono foram avaliadas através da tonometria arterial periférica pelos equipamentos Endo-PAT2000 e o aparelho portátil Watch-PAT200, respectivamente. A avaliação antropométrica foi realizada através das aferições das circunferências da cintura e do pescoço, índice de massa corporal (IMC), e relação cintura-estatura. A composição corporal foi avaliada por bioimpedância elétrica BIODYNAMICS 450. As análises estatísticas foram realizadas pelo software GraphPad PRISM, versão 6.01. A prevalência de AOS no grupo com HAR foi de 85% (Índice de apneia-hipopneia [AHI]= 12,391,89) e de 80% no grupo com HAC (AHI =20,744,69), sendo mais frequente em homens (p=0,04; OR=3,86; 95% IC 0,99 a 14,52). Os dois grupos apresentaram valores semelhantes das variáveis antropométricas avaliadas. A função endotelial avaliada pelo índice de hiperemia reativa foi similar nos dois grupos (grupo HAR: 1,880,09 vs. grupo HAC: 2,030,09; p=0,28). Apesar do número de dessaturações de oxigênio >4% ter apresentado diferença significativa entre os grupos (grupo HAR: 28,755,08 vs. grupo HAC: 64,1516,97; p=0,04), o tempo total de sono (grupo HAR: 309,515,27 vs. grupo HAC: 323,318,74 min) e a saturação mínima da oxi-hemoglobina (grupo HAR: 87,80,85 vs. grupo HAC: 83,32,37%) não mostraram essa diferença. Considerando todos os pacientes hipertensos, o AHI apresentou correlação significativa com o peso corporal (r=0,51; p=0,0007), o IMC (r=0,41; p=0,007), a circunferência da cintura (r=0,44; p=0,005), a circunferência do pescoço (r=0,38; p=0,01) e a relação cintura-estatura (r=0,39; p=0,01). Os pacientes sem AOS em comparação com os pacientes com AOS, apresentaram risco significativamente menor de apresentar comprometimento da função endotelial (OR=0,17; 95% IC 0,04-0,72; p=0,03). Os achados do presente estudo sugerem que a prevalência de AOS em pacientes com hipertensão resistente é elevada, porém semelhante a de indivíduos com hipertensão controlada. Pacientes com hipertensão resistente e controlada não apresentaram diferenças significativas em relação à função endotelial. A gravidade de AOS no grupo total de hipertensos se associou com maior risco de comprometimento da função endotelial.