875 resultados para vacuum aspiratory technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular distillation is show as an alternative for separation and purification of various kinds of materials. The process is a special case of evaporation at high vacuum, in the order from 0.001 to 0.0001 mmHg and therefore occurs at relatively lower temperatures, preserves the material to be purified. In Brazil, molecular distillation is very applied in the separation of petroleum fractions. However, most studies evaluated the temperature of the evaporator, condenser temperature and flow such variables of the molecular distillation oil. Then, to increase the degree of recovery of the fraction of the distillate obtained in the process of the molecular distillation was evaluated the use nonionic surfactants of the class of nonylphenol ethoxylate, molecules able to interact in the liquid-liquid and liquid-vapor interface various systems. In this context, the aim of this work was to verify the influence of commercial surfactant (Ultranex-18 an Ultranex-18-50) in the molecular distillation of a crude oil. The physicochemical characterization of the oil was realized and the petroleum shown an API gravity of 42°, a light oil. Initially, studied the molecular distillation without surfactant using star design experimental (2H ± ) evaluated two variables (evaporator temperature and condenser temperature) and answer variable was the percentage in distillate obtained in the process (D%). The best experimental condition to molecular distillation oil (38% distillate) was obtained at evaporator and condenser temperatures of 120 °C and 10 ° C, respectively. Subsequently, to determine the range of surfactant concentration to be applied in the process, was determined the critical micellar concentration by the technique of scattering X-ray small angle (SAXS). The surfactants Ultranex-18 an Ultranex-18-50 shown the critical micelle concentration in the range of 10-2 mol/L in the hydrocarbons studied. Then, was applied in the study of distillation a concentration range from 0.01 to 0.15 mol/L of the surfactants (Ultranex- 18 and 50). The use of the nonionic surfactant increased the percentage of hydrocarbons in the range from 5 to 9 carbons in comparison to the process carried out without surfactant, and in some experimental conditions the fraction of light compounds in the distilled was over 700% compared to the conventional process. The study showed that increasing the degree of ethoxylation of Ultranex18 to Ultranex-50, the compounds in the range of C5 to C9 reduced the percentage in the distilled, since the increase of the hydrophilic part of the surfactant reduces its solubility in the oil. Finally, was obtained an increase in the degree of recovery of light hydrocarbons, comparing processes with and without surfactant, obtained an increase of 10% and 4% with Ultranex-18 and Ultranex-50, respectively. Thus, it is concluded that the Ultranex- 18 surfactant showed a higher capacity to distillation compared with Ultranex-50 and the application of surfactant on the molecular distillation from petroleum allowed for a greater recovery of light compounds in distillate

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An approximately 9-month-old fox (Pseudalopex ventulus) was presented With malocclusion and deviation of the lower jaw to the right side. Orthodontic treatment was performed using the inclined plane technique. Virtual 3D models and prototypes of the head were based on computed tomography (CT) image data to assist in diagnosis and treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tissue microarray (TMA) technique allows multiple tissue samples in a single block. Commercial adhesive tape is used to avoid the loss of tissue samples during the immunostaining process. Few reports exist in the literature comparing the use of these adhesive tapes to other adhesive techniques. The objective of this study was to compare loss of sections adhered to slides using commercial adhesive tapes versus using silanized only slides. TMA was constructed with varying tissues using a fixed-base device (Beecher Instruments), placing 108 cylinders of 1 mm diameter in duplicate, spaced 1.2 mm apart. Section of 4 mu m were cut from the TMA block and adhered to 30 silanized slides and 30 commercial glass slides using adhesive tape, according to manufacturer's recommendations. Vimentin immunoexpression was evaluated by immunohistochemistry. Antigenic recovery was realized in citrate buffer using a microwave oven. Cylinder loss in the immunohistochemical process was quantified and expressed as: total (>80%), almost complete (75-79%), or partial (50-74%). The commercial adhesive tape group presented lesser total loss (1.1 versus 6.4%), almost complete loss (2.2 versus 3.5%), and partial loss (2.1 versus 3.8%) than the silanized slide group (ANOVA, P < 0.05). The sum of total and almost complete losses in the silanized slide group was 9.9%, greater than the losses in slides using commercial adhesive tapes (3.3%) and less than reported and considered acceptable in the literature (10-30%). In conclusion, the use of silanized only slides presents very satisfactory results, requires less training, and reduces costs significantly, thus justifying their use in research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An 8-year-old male Boxer with a severely contaminated open fracture of the left radius and ulna fracture, produced by a helicopter propeller, was treated using bone transport by the Ilizarov method. Extensive diaphyseal bone loss and soft-tissue vascular damage were present. The radius and ulna were stabilised with an Ilizarov ring external fixator. The bone defect was partially shortened and restored by gradual transport of a bone segment created from proximal segments of the radius and ulna. The external fixator was removed 4fi months after the beginning of the latency period, due to instability caused by osteolysis around the wires. A cast was placed for 3 weeks. Although the bone transport had resulted in formation of approximately 4 cm of bone, the antebrachium showed approximately 50% shortening when compared to the contralateral limb. The infection was eradicated, and the dog was able to bear weight on the operated limb when walking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes an alternative surgical approach to the harvesting of subepithelial connective tissue grafts from thin palates. A partial-thickness flap is raised, and a graft composed of epithelium and connective tissue is removed from the palate. The superficial layer ( epithelium and a thin zone of connective tissue) is then dissected from the graft and replaced at the donor site to facilitate faster healing. The subjacent layer of connective tissue is placed as needed to obtain root coverage. The clinical application of this technique is described in two patients with multiple gingival recessions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A common finding in patients with edentulous maxilla and partially dentate mandible is mainly the presence of flabbiness in the anterior edentulous alveolar ridge that can compromise the retention and stability of a denture. Thus, this case report presents the correction of a flabby ridge, using an auxiliary technique combining surgical excision and autogenous connective tissue grafting. The technique improved the quality of the osteomucosal support of the alveolar ridge and increased the vestibule deepness, whose result increased the success rate of the new conventional total prosthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory pros-thodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.