909 resultados para surgical instrument


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The surgical treatment of oral cancer results in functional and aesthetical impairments. Patients' quality of life is considerably impaired by oral symptoms resulting from therapy of oral cancer. In many cases the inevitable resection of the tumor, as well as the adjuvant radiochemotherapy will cause the destruction of physiologically and anatomically important structures. One focus of research was the specific rehabilitation of dental loss by functional dentures. Another was the course of 19 impairments (comprehension of speech for unknown others, comprehension of speech for familiar others, eating/swallowing, mobility of the tongue, opening range of the mouth, mobility of lower jaw, mobility of neck, mobility of arms and shoulders, sense of taste, sense of smell, appearance, strength, appetite, respiration, pain, swelling, xerostomia, halitosis). METHODS: Commissioned by the German, Austrian and Swiss cooperative group on tumors of the maxillofacial region (DOSAK), data were collected in 3.894 questionnaires at 43 hospitals in Germany, Austria and Switzerland. The catalogue comprised 147 items in 9 chapters. At the end of the enquiry, 1.761 anonymous questionnaires were returned by 38 hospitals. 1.652 of these could be evaluated regarding the question. RESULTS: The sum score of the 19 impairments was highly increased immediately after the operation and recovered over the next 6 months, without, however, reaching the pre-surgery level. Of 1.652 patients, only 35% did not lose any teeth during therapy. 23% lost up to 5, 17% up to 10 teeth. A quarter of the patients lost more than 10 teeth. The more teeth were lost, the greater the decline of quality of life (p < or = 0.001), although this could be allayed by the functionality of the dentures (p < or = 0.001). There is a reciprocal dependence between the functionality of dental prosthetics and impairment by eating/swallowing (p < or = 0.001). CONCLUSIONS: Patients' quality of life after radical surgery of a carcinoma of the oral cavity depends not only on the functionality of dentures and the specificity of rehabilitation, but also from the initial findings, the extent and location of the resection, the chosen therapy, the general circumstances of the patient's life as well as their strategies of coping. These factors, however, unlike those of functionality of dental prosthesis and rehabilitation, are not modifiable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The final goal of mandibular reconstruction following ablative surgery for oral cancer is often considered to be dental implant-supported oral rehabilitation, for which bone grafts should ideally be placed in a suitable position taking subsequent prosthetic restoration into account. The aim of this study was to evaluate the efficacy of a standardized treatment strategy for mandibular reconstruction according to the size of the bony defect and planned subsequent dental prosthetic rehabilitation. Data of 56 patients, who had undergone such a systematic mandibular fibula free flap reconstruction, were retrospectively analyzed. Early complications were observed in 41.5% of the patients but only in those who had been irradiated. Late complications were found in 38.2%. Dental implant survival rate was 92%, and dental prosthetic treatment has been completed in all classes of bony defects with an overall success rate of 42.9%. The main reasons for failure of the complete dental reconstruction were patients' poor cooperation (30.4%) and tumour recurrence (14.3%) followed by surgery-related factors (10.8%) such as implant failure and an unfavourable intermaxillary relationship between the maxilla and the mandible. A comparison of our results with the literature findings revealed no marked differences in the complication rates and implant survival rates. However, a systematic concept for the reconstructive treatment like the method presented here, plays an important role in the successful completion of dental reconstruction. The success rate could still be improved by some technical progress in implant and bone graft positioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of complex aortic pathologies involving the ascending aorta, the aortic arch, and the descending aorta remains a challenging issue in aortic surgery. The frozen elephant trunk procedure effectively combines surgical and interventional technologies in the treatment of extensive aortic aneurysms and dissections. We present two patients with complex aortic lesions involving all three segments of the thoracic aorta. The device used in our series is the new E-vita open hybrid prosthesis consisting of a proximal woven polyester tube and a distal self-expandable nitinol stent graft, which can be delivered antegrade into the descending aorta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To assess perioperative outcomes and blood pressure (BP) responses to an implantable carotid sinus baroreflex activating system being investigated for the treatment of resistant hypertension. METHODS: We report on the first seventeen patients enrolled in a multicenter study. Bilateral perivascular carotid sinus electrodes (CSL) and a pulse generator (IPG) are permanently implanted. Optimal placement of the CSL is determined by intraoperative BP responses to test activations. Acute BP responses were tested postoperatively and during the first four months of follow-up. RESULTS: Prior to implant, BP was 189.6+/-27.5/110.7+/-15.3 mmHg despite stable therapy (5.2+/-1.8 antihypertensive drugs). The mean procedure time was 202+/-43 minutes. No perioperative strokes or deaths occurred. System tests performed 1 or up to 3 days postoperatively resulted in significant (all p < or = 0.0001) mean maximum reduction, with standard deviations and 95% confidence limits for systolic BP, diastolic BP and heart rate of 28+/-22 (17, 39) mmHg, 16+/-11 (10, 22) mmHg and 8+/-4 (6, 11) BPM, respectively. Repeated testing during 3 months of therapeutic electrical activation demonstrated a durable response. CONCLUSIONS: These preliminary data suggest an acceptable safety of the procedure with a low rate of adverse events and support further clinical development of baroreflex activation as a new concept to treat resistant hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Constructing a 3D surface model from sparse-point data is a nontrivial task. Here, we report an accurate and robust approach for reconstructing a surface model of the proximal femur from sparse-point data and a dense-point distribution model (DPDM). The problem is formulated as a three-stage optimal estimation process. The first stage, affine registration, is to iteratively estimate a scale and a rigid transformation between the mean surface model of the DPDM and the sparse input points. The estimation results of the first stage are used to establish point correspondences for the second stage, statistical instantiation, which stably instantiates a surface model from the DPDM using a statistical approach. This surface model is then fed to the third stage, kernel-based deformation, which further refines the surface model. Handling outliers is achieved by consistently employing the least trimmed squares (LTS) approach with a roughly estimated outlier rate in all three stages. If an optimal value of the outlier rate is preferred, we propose a hypothesis testing procedure to automatically estimate it. We present here our validations using four experiments, which include 1 leave-one-out experiment, 2 experiment on evaluating the present approach for handling pathology, 3 experiment on evaluating the present approach for handling outliers, and 4 experiment on reconstructing surface models of seven dry cadaver femurs using clinically relevant data without noise and with noise added. Our validation results demonstrate the robust performance of the present approach in handling outliers, pathology, and noise. An average 95-percentile error of 1.7-2.3 mm was found when the present approach was used to reconstruct surface models of the cadaver femurs from sparse-point data with noise added.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A patient-specific surface model of the proximal femur plays an important role in planning and supporting various computer-assisted surgical procedures including total hip replacement, hip resurfacing, and osteotomy of the proximal femur. The common approach to derive 3D models of the proximal femur is to use imaging techniques such as computed tomography (CT) or magnetic resonance imaging (MRI). However, the high logistic effort, the extra radiation (CT-imaging), and the large quantity of data to be acquired and processed make them less functional. In this paper, we present an integrated approach using a multi-level point distribution model (ML-PDM) to reconstruct a patient-specific model of the proximal femur from intra-operatively available sparse data. Results of experiments performed on dry cadaveric bones using dozens of 3D points are presented, as well as experiments using a limited number of 2D X-ray images, which demonstrate promising accuracy of the present approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of an intestinal stoma is one of the most frequent operations in visceral surgery. Despite new operative techniques and a more restrictive use of the stoma, the stoma formation remains an often necessary surgical procedure, which results to a dramatic change in the patients' life. The stoma formation and its later closure are associated with a high morbidity. Many complications, such as stoma necrosis, stoma retraction or stoma prolapse, are related to surgical mistakes made during stoma formation. These complications are therefore largely avoidable. The stoma formation needs careful planning together with a professional stoma nursing team. Moreover, it is mandatory that the stoma formation is made with great care and that it meticulously follows the well established surgical principles. A perfectly placed, technically correctly fashioned and easy to care for stoma is essential for a good patients'quality of life.