954 resultados para quantum computing, molecular electronics, lab-on-a-chip


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Molecular shape has long been known to be an important property for the process of molecular recognition. Previous studies postulated the existence of a drug-like shape space that could be used to artificially bias the composition of screening libraries, with the aim to increase the chance of success in Hit Identification. In this work, it was analysed to which extend this assumption holds true. Normalized Principal Moments of Inertia Ratios (NPRs) have been used to describe the molecular shape of small molecules. It was investigated, whether active molecules of diverse targets are located in preferred subspaces of the NPR shape space. Results illustrated a significantly stronger clustering than could be expected by chance, with parts of the space unlikely to be occupied by active compounds. Furthermore, a strong enrichment of elongated, rather flat shapes could be observed, while globular compounds were highly underrepresented. This was confirmed for a wide range of small molecule datasets from different origins. Active compounds exhibited a high overlap in their shape distributions across different targets, making a purely shape­ based discrimination very difficult. An additional perspective was provided by comparing the shapes of protein binding pockets with those of their respective ligands. Although more globular than their ligands, it was observed that binding sites shapes exhibited a similarly skewed distribution in shape space: spherical shapes were highly underrepresented. This was different for unoccupied binding pockets of smaller size. These were on the contrary identified to possess a more globular shape. The relation between shape complementarity and exhibited bioactivity was analysed; a moderate correlation between bioactivity and parameters including pocket coverage, distance in shape space, and others could be identified, which reflects the importance of shape complementarity. However, this also suggests that other aspects are of relevance for molecular recognition. A subsequent analysis assessed if and how shape and volume information retrieved from pocket or respective reference ligands could be used as a pre-filter in a virtual screening approach. ln Lead Optimization compounds need to get optimized with respect to a variety of pararneters. Here, the availability of past success stories is very valuable, as they can guide medicinal chemists during their analogue synthesis plans. However, although of tremendous interest for the public domain, so far only large corporations had the ability to mine historical knowledge in their proprietary databases. With the aim to provide such information, the SwissBioisostere database was developed and released during this thesis. This database contains information on 21,293,355 performed substructural exchanges, corresponding to 5,586,462 unique replacements that have been measured in 35,039 assays against 1,948 molecular targets representing 30 target classes, and on their impact on bioactivity . A user-friendly interface was developed that provides facile access to these data and is accessible at http//www.swissbioisostere.ch. The ChEMBL database was used as primary data source of bioactivity information. Matched molecular pairs have been identified in the extracted and cleaned data. Success-based scores were developed and integrated into the database to allow re-ranking of proposed replacements by their past outcomes. It was analysed to which degree these scores correlate with chemical similarity of the underlying fragments. An unexpectedly weak relationship was detected and further investigated. Use cases of this database were envisioned, and functionalities implemented accordingly: replacement outcomes are aggregatable at the assay level, and it was shawn that an aggregation at the target or target class level could also be performed, but should be accompanied by a careful case-by-case assessment. It was furthermore observed that replacement success depends on the activity of the starting compound A within a matched molecular pair A-B. With increasing potency the probability to lose bioactivity through any substructural exchange was significantly higher than in low affine binders. A potential existence of a publication bias could be refuted. Furthermore, often performed medicinal chemistry strategies for structure-activity-relationship exploration were analysed using the acquired data. Finally, data originating from pharmaceutical companies were compared with those reported in the literature. It could be seen that industrial medicinal chemistry can access replacement information not available in the public domain. In contrast, a large amount of often-performed replacements within companies could also be identified in literature data. Preferences for particular replacements differed between these two sources. The value of combining different endpoints in an evaluation of molecular replacements was investigated. The performed studies highlighted furthermore that there seem to exist no universal substructural replacement that always retains bioactivity irrespective of the biological environment. A generalization of bioisosteric replacements seems therefore not possible. - La forme tridimensionnelle des molécules a depuis longtemps été reconnue comme une propriété importante pour le processus de reconnaissance moléculaire. Des études antérieures ont postulé que les médicaments occupent préférentiellement un sous-ensemble de l'espace des formes des molécules. Ce sous-ensemble pourrait être utilisé pour biaiser la composition de chimiothèques à cribler, dans le but d'augmenter les chances d'identifier des Hits. L'analyse et la validation de cette assertion fait l'objet de cette première partie. Les Ratios de Moments Principaux d'Inertie Normalisés (RPN) ont été utilisés pour décrire la forme tridimensionnelle de petites molécules de type médicament. Il a été étudié si les molécules actives sur des cibles différentes se co-localisaient dans des sous-espaces privilégiés de l'espace des formes. Les résultats montrent des regroupements de molécules incompatibles avec une répartition aléatoire, avec certaines parties de l'espace peu susceptibles d'être occupées par des composés actifs. Par ailleurs, un fort enrichissement en formes allongées et plutôt plates a pu être observé, tandis que les composés globulaires étaient fortement sous-représentés. Cela a été confirmé pour un large ensemble de compilations de molécules d'origines différentes. Les distributions de forme des molécules actives sur des cibles différentes se recoupent largement, rendant une discrimination fondée uniquement sur la forme très difficile. Une perspective supplémentaire a été ajoutée par la comparaison des formes des ligands avec celles de leurs sites de liaison (poches) dans leurs protéines respectives. Bien que plus globulaires que leurs ligands, il a été observé que les formes des poches présentent une distribution dans l'espace des formes avec le même type d'asymétrie que celle observée pour les ligands: les formes sphériques sont fortement sous­ représentées. Un résultat différent a été obtenu pour les poches de plus petite taille et cristallisées sans ligand: elles possédaient une forme plus globulaire. La relation entre complémentarité de forme et bioactivité a été également analysée; une corrélation modérée entre bioactivité et des paramètres tels que remplissage de poche, distance dans l'espace des formes, ainsi que d'autres, a pu être identifiée. Ceci reflète l'importance de la complémentarité des formes, mais aussi l'implication d'autres facteurs. Une analyse ultérieure a évalué si et comment la forme et le volume d'une poche ou de ses ligands de référence pouvaient être utilisés comme un pré-filtre dans une approche de criblage virtuel. Durant l'optimisation d'un Lead, de nombreux paramètres doivent être optimisés simultanément. Dans ce contexte, la disponibilité d'exemples d'optimisations réussies est précieuse, car ils peuvent orienter les chimistes médicinaux dans leurs plans de synthèse par analogie. Cependant, bien que d'un extrême intérêt pour les chercheurs dans le domaine public, seules les grandes sociétés pharmaceutiques avaient jusqu'à présent la capacité d'exploiter de telles connaissances au sein de leurs bases de données internes. Dans le but de remédier à cette limitation, la base de données SwissBioisostere a été élaborée et publiée dans le domaine public au cours de cette thèse. Cette base de données contient des informations sur 21 293 355 échanges sous-structuraux observés, correspondant à 5 586 462 remplacements uniques mesurés dans 35 039 tests contre 1948 cibles représentant 30 familles, ainsi que sur leur impact sur la bioactivité. Une interface a été développée pour permettre un accès facile à ces données, accessible à http:/ /www.swissbioisostere.ch. La base de données ChEMBL a été utilisée comme source de données de bioactivité. Une version modifiée de l'algorithme de Hussain et Rea a été implémentée pour identifier les Matched Molecular Pairs (MMP) dans les données préparées au préalable. Des scores de succès ont été développés et intégrés dans la base de données pour permettre un reclassement des remplacements proposés selon leurs résultats précédemment observés. La corrélation entre ces scores et la similarité chimique des fragments correspondants a été étudiée. Une corrélation plus faible qu'attendue a été détectée et analysée. Différents cas d'utilisation de cette base de données ont été envisagés, et les fonctionnalités correspondantes implémentées: l'agrégation des résultats de remplacement est effectuée au niveau de chaque test, et il a été montré qu'elle pourrait également être effectuée au niveau de la cible ou de la classe de cible, sous réserve d'une analyse au cas par cas. Il a en outre été constaté que le succès d'un remplacement dépend de l'activité du composé A au sein d'une paire A-B. Il a été montré que la probabilité de perdre la bioactivité à la suite d'un remplacement moléculaire quelconque est plus importante au sein des molécules les plus actives que chez les molécules de plus faible activité. L'existence potentielle d'un biais lié au processus de publication par articles a pu être réfutée. En outre, les stratégies fréquentes de chimie médicinale pour l'exploration des relations structure-activité ont été analysées à l'aide des données acquises. Enfin, les données provenant des compagnies pharmaceutiques ont été comparées à celles reportées dans la littérature. Il a pu être constaté que les chimistes médicinaux dans l'industrie peuvent accéder à des remplacements qui ne sont pas disponibles dans le domaine public. Par contre, un grand nombre de remplacements fréquemment observés dans les données de l'industrie ont également pu être identifiés dans les données de la littérature. Les préférences pour certains remplacements particuliers diffèrent entre ces deux sources. L'intérêt d'évaluer les remplacements moléculaires simultanément selon plusieurs paramètres (bioactivité et stabilité métabolique par ex.) a aussi été étudié. Les études réalisées ont souligné qu'il semble n'exister aucun remplacement sous-structural universel qui conserve toujours la bioactivité quel que soit le contexte biologique. Une généralisation des remplacements bioisostériques ne semble donc pas possible.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have studied the structure and dipole charge-density response of nanorings as a function of the magnetic field using local-spin-density-functional theory. Two small rings consisting of 12 and 22 electrons confined by a positively charged background are used to represent the cases of narrow and wide rings. The results are qualitatively compared with experimental data existing on microrings and on antidots. A smaller ring containing five electrons is also analyzed to allow for a closer comparison with a recent experiment on a two-electron quantum ring.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have employed time-dependent local-spin density-functional theory to analyze the multipole spin and charge density excitations in GaAs-AlxGa1-xAs quantum dots. The on-plane transferred momentum degree of freedom has been taken into account, and the wave-vector dependence of the excitations is discussed. In agreement with previous experiments, we have found that the energies of these modes do not depend on the transferred wave vector, although their intensities do. Comparison with a recent resonant Raman scattering experiment [C. Schüller et al., Phys. Rev. Lett. 80, 2673 (1998)] is made. This allows us to identify the angular momentum of several of the observed modes as well as to reproduce their energies

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have investigated the structure of double quantum dots vertically coupled at zero magnetic field within local-spin-density functional theory. The dots are identical and have a finite width, and the whole system is axially symmetric. We first discuss the effect of thickness on the addition spectrum of one single dot. Next we describe the structure of coupled dots as a function of the interdot distance for different electron numbers. Addition spectra, Hund's rule, and molecular-type configurations are discussed. It is shown that self-interaction corrections to the density-functional results do not play a very important role in the calculated addition spectra

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The interplay between Rashba, Dresselhaus, and Zeeman interactions in a quantum well submitted to an external magnetic field is studied by means of an accurate analytical solution of the Hamiltonian, including electron-electron interactions in a sum-rule approach. This solution allows us to discuss the influence of the spin-orbit coupling on some relevant quantities that have been measured in inelastic light scattering and electron-spin resonance experiments on quantum wells. In particular, we have evaluated the spin-orbit contribution to the spin splitting of the Landau levels and to the splitting of charge- and spin-density excitations. We also discuss how the spin-orbit effects change if the applied magnetic field is tilted with respect to the direction perpendicular to the quantum well.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Résumé Fondement : le développement de solutions d'hydroxy-éthyl-amidons (HEAS) avec peu d'impact sur la coagulation sanguine, mais un effet supérieur sur la volémie, par comparaison aux HEAS couramment utilisés, est d'un grand intérêt clinique. Nous posons l'hypothèse que des solutions de haut poids moléculaire et de bas degré de substitution possèdent ces caractéristiques. Méthode : trente porcs ont été perfusés avec trois HEAS différents (20 ml/kg) de même degré de substitution (0.42) mais de poids moléculaire différent (130, 500 et 900 kDa). Une série de prélèvements sanguins ont été effectués sur 24 heures, sur lesquels des analyses de coagulation sanguine étaient effectuées par thromboélastographie et dosages plasmatiques. De plus, la concentration plasmatique ainsi que le poids moléculaire in vivo ont été déterminés, ainsi que des paramètres de pharmacocinétiques, ceci en se basant sur un modèle bi-compartimental. Résultats : les analyses de thromboélastographie et les tests de coagulation plasmatique n'ont pas démontré d'altération plus marquée de la coagulation sanguine après l'utilisation des solutions des HAES 500 et HAES 900, par comparaison avec celle de HAES 130. Par contre, les HAES 500 et HAES 900 ont présenté une plus grande aire sous la courbe (area under the curve), dans la relation concentration en fonction du temps [1542 (142) g min litre-1, p<0.001, 1701 (321) g min litre-1, p<0.001] par rapport au HAES 130 [1156 (223) g min litre-1]. La demi-vie alpha (t ½α) était plus longue pour les HAES 500 [53.8 (8.6) min, p<0.01] et HAES 900 [57.1 (12.3) min, p<0.01 ]que pour le HAES 130 [39.9 (10.7) min]. La demi-vie beta (t½β) était par contre similaire pour les trois types de HAES [de 332 (100) à 381 (63) min]. Conclusions : pour les HAES de bas degré de substitution, le poids moléculaire n'est pas un facteur clé en ce qui concerne l'altération de la coagulation. La persistance intravasculaire initialement plus longue des HAES de haut poids moléculaire et bas degré de substitution pourrait résulter dans un plus long effet volémique de ces substances. Abstract Background: The development of hydroxyethyl starches (HES) with low impact on blood coagulation but higher volume effect compared with the currently used HES solutions is of clinical interest. We hypothesized that high molecular weight, low-substituted HES might possess these properties. Methods: Thirty pigs were infused with three different HES solutions (20 ml kg-1) with the same degree of molar substitution (0.42) but different molecular weights (130, 500 and 900 kDa). Serial blood samples were taken over 24 h and blood coagulation was assessed by Thromboelastograph® analysis and analysis of plasma coagulation. In addition, plasma concentration and in vivo molecular weight were determined and pharmacokinetic data were computed based on a two-compartment model. Results: Thromboelastograph analysis and plasma coagulation tests did not reveal a more pronounced alteration of blood coagulation with HES 500 and HES 900 compared with HES 130. In contrast, HES 500 and HES 900 had a greater area under the plasma concentration-time curve [1542 (142) g min litre-1, P<0.001, 1701 (321) g min litre-1, P<0.001] than HES 130 [I 156 (223) g min litre-1] and alpha half life (t ½α) was longer for HES 500 [53.8 (8.6) min, P<0.01 ] and HES 900 [57. I (I 2.3) min, P<0.01 ] than for HES 130 [39.9 (I 0.7) min]. Beta half life (t½β), however, was similar for all three types of HES [from 332 (100) to 381 (63) min]. Conclusions. In low-substituted HES, molecular weight is not a key factor in compromising blood coagulation. The longer initial intravascular persistence of high molecular weight lowsubstituted HES might result in a longer lasting volume effect.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A lot of research in cognition and decision making suffers from a lack of formalism. The quantum probability program could help to improve this situation, but we wonder whether it would provide even more added value if its presumed focus on outcome models were complemented by process models that are, ideally, informed by ecological analyses and integrated into cognitive architectures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The transport and magnetotransport properties of the metallic and ferromagnetic SrRuO3 (SRO) and the metallic and paramagnetic LaNiO3 (LNO) epitaxial thin films have been investigated in fields up to 55 T at temperatures down to 1.8 K . At low temperatures both samples display a well-defined resistivity minimum. We argue that this behavior is due to the increasing relevance of quantum corrections to the conductivity (QCC) as temperature is lowered; this effect being particularly relevant in these oxides due to their short mean free path. However, it is not straightforward to discriminate between contributions of weak localization and renormalization of electron-electron interactions to the QCC through temperature dependence alone. We have taken advantage of the distinct effect of a magnetic field on both mechanisms to demonstrate that in ferromagnetic SRO the weak-localization contribution is suppressed by the large internal field leaving only renormalized electron-electron interactions, whereas in the nonmagnetic LNO thin films the weak-localization term is relevant.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Résumé La cryptographie classique est basée sur des concepts mathématiques dont la sécurité dépend de la complexité du calcul de l'inverse des fonctions. Ce type de chiffrement est à la merci de la puissance de calcul des ordinateurs ainsi que la découverte d'algorithme permettant le calcul des inverses de certaines fonctions mathématiques en un temps «raisonnable ». L'utilisation d'un procédé dont la sécurité est scientifiquement prouvée s'avère donc indispensable surtout les échanges critiques (systèmes bancaires, gouvernements,...). La cryptographie quantique répond à ce besoin. En effet, sa sécurité est basée sur des lois de la physique quantique lui assurant un fonctionnement inconditionnellement sécurisé. Toutefois, l'application et l'intégration de la cryptographie quantique sont un souci pour les développeurs de ce type de solution. Cette thèse justifie la nécessité de l'utilisation de la cryptographie quantique. Elle montre que le coût engendré par le déploiement de cette solution est justifié. Elle propose un mécanisme simple et réalisable d'intégration de la cryptographie quantique dans des protocoles de communication largement utilisés comme les protocoles PPP, IPSec et le protocole 802.1li. Des scénarios d'application illustrent la faisabilité de ces solutions. Une méthodologie d'évaluation, selon les critères communs, des solutions basées sur la cryptographie quantique est également proposée dans ce document. Abstract Classical cryptography is based on mathematical functions. The robustness of a cryptosystem essentially depends on the difficulty of computing the inverse of its one-way function. There is no mathematical proof that establishes whether it is impossible to find the inverse of a given one-way function. Therefore, it is mandatory to use a cryptosystem whose security is scientifically proven (especially for banking, governments, etc.). On the other hand, the security of quantum cryptography can be formally demonstrated. In fact, its security is based on the laws of physics that assure the unconditional security. How is it possible to use and integrate quantum cryptography into existing solutions? This thesis proposes a method to integrate quantum cryptography into existing communication protocols like PPP, IPSec and the 802.l1i protocol. It sketches out some possible scenarios in order to prove the feasibility and to estimate the cost of such scenarios. Directives and checkpoints are given to help in certifying quantum cryptography solutions according to Common Criteria.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we study the effect of microwave absorption on the quantum relaxation rate of Mn12 molecular clusters. We have determined first the resonant frequencies of a microwave resonator containing a single crystal of Mn12-Acetate and measured initial isothermal magnetization curves while microwave power was put into the resonator. We have found that the tunneling rate changes one order of magnitude for certain frequencies. This suggests that the microwave shaking of the nuclear spin and molecular vibrational degrees of freedom is responsible for the huge increasing of the tunneling rate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We develop a covariant quantum theory of fluctuations on vacuum domain walls and strings. The fluctuations are described by a scalar field defined on the classical world sheet of the defects. We consider the following cases: straight strings and planar walls in flat space, true vacuum bubbles nucleating in false vacuum, and strings and walls nucleating during inflation. The quantum state for the perturbations is constructed so that it respects the original symmetries of the classical solution. In particular, for the case of vacuum bubbles and nucleating strings and walls, the geometry of the world sheet is that of a lower-dimensional de Sitter space, and the problem reduces to the quantization of a scalar field of tachyonic mass in de Sitter space. In all cases, the root-mean-squared fluctuation is evaluated in detail, and the physical implications are briefly discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: The AMS 800 is the current artifi cial urinary sphincter (AUS) forincontinence due to intrinsic sphincter defi ciency. Despite good clinical results,technical failures inherent to the hydraulic mechanism or urethral ischemicinjury contribute to revisions up to 60%. We are developing an electronic AUS,called ARTUS to overcome the rigors of AMS. The objective of this study wasto evaluate the technical effi cacy and tissue tolerance of the ARTUS systemin an animal model.Methods: The ARTUS is composed by three parts: thecontractile unit, a series of rings and an integrated microprocessor. The contractileunit is made of Nitinol fi bers. The rings are placed around the urethrato control the fl ow of urine by squeezing the urethra. They work in a sequentialalternative mode and are controlled by a microprocessor. In the fi rst phase athree-rings device was used while in the second phase a two-rings ARTUS wasused. The device was implanted in 14 sheep divided in two groups of six andeight animals for study purpose. The fi rst group aimed at bladder leak pointpressure (BLPP) measurement and validation of the animal model; the secondgroup aimed at verifying midterm tissue tolerance by explants at twelve weeks.General animal tolerance was also evaluated.Results: The ARTUS systemimplantation was uneventful. When the system was activated, the BLPP wasmeasured at 1.038 ± 0.044 bar (mean ± SD). Urethral tissue analysis did notshow signifi cant morphological changes. No infection and no sign of discomfortwere noted in animals at 12 weeks.Conclusions: The ARTUS proved to beeffective in continence achievement in this study. Histological results supportour idea that a sequential alternative mode can avoid urethral atrophy andischemia. Further technical developments are needed to verify long-termoutcome and permit human use.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The recent observation of steps at regular intervals of magnetic field in the hysteresis loops of oriented crystals of the spin-10 molecular magnet Mn12O12(CH3COO)16(H2O)4 has been attributed to resonant tunneling between spin states. Here, we investigate the effect on the relaxation rate of applying the magnetic field at an angle with respect to the easy axis of magnetization. We find that the position of the resonances is independent of the transverse component of the field, and is determined solely by the longitudinal component. On the other hand, a transverse field significantly increases the relaxation rate, both on and off resonance. We discuss classical and quantum mechanical interpretations of this effect

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Interactions between the leukocyte adhesion receptor L-selectin and P-selectin glycoprotein ligand-1 play an important role in regulating the inflammatory response by mediating leukocyte tethering and rolling on adherent leukocytes. In this study, we have examined the effect of post-translational modifications of PSGL-1 including Tyr sulfation and presentation of sialylated and fucosylated O-glycans for L-selectin binding. The functional importance of these modifications was determined by analyzing soluble L-selectin binding and leukocyte rolling on CHO cells expressing various glycoforms of PSGL-1 or mutant PSGL-1 targeted at N-terminal Thr or Tyr residues. Simultaneous expression of core-2 beta1,6-N-acetylglucosaminyltransferase and fucosyltransferase VII was required for optimal L-selectin binding to PSGL-1. Substitution of Thr-57 by Ala but not of Thr-44, strongly decreased L-selectin binding and leukocyte rolling on PSGL-1. Substitution of Tyr by Phe revealed that PSGL-1 Tyr-51 plays a predominant role in mediating L-selectin binding and leukocyte rolling whereas Tyr-48 has a minor role, an observation that contrasts with the pattern seen for the interactions between PSGL-1 and P-selectin where Tyr-48 plays a key role. Molecular modeling analysis of L-selectin and P-selectin interactions with PSGL-1 further supported these observations. Additional experiments showed that core-2 O-glycans attached to Thr-57 were also of critical importance in regulating the velocity and stability of leukocyte rolling. These observations pinpoint the structural characteristics of PSGL-1 that are required for optimal interactions with L-selectin and may be responsible for the specific kinetic and mechanical bond properties of the L-selectin-PSGL-1 adhesion receptor-counterreceptor pair.