938 resultados para pressure-assisted field-amplified sample injection
Resumo:
We determined the effects of two classical angiotensin II (ANG II) antagonists, [Sar(1), Ala(8)]-ANG II and [Sar(1), Thr(8)]-ANG II, and losartan (a nonpeptide and selective antagonist for the AT 1 angiotensin receptors) on diuresis, natriuresis, kaliuresis and arterial blood pressure induced by ANG II administration into the median preoptic nucleus (MnPO) of male Holtzman rats weighing 250-300 g. Urine was collected in rats submitted to a water load (5% body weight) by gastric gavage, followed by a second water load (5% body weight) 1 h later. The volume of the drug solutions injected was 0.5 mu l over 10-15 s. Pre-treatment with [Sar(1), Ala(8)]-ANG II (12 rats) and [Sar(1), Thr(8)]-ANG II (9 rats), at the dose of 60 ng reduced (13.7 +/- 1.0 vs 11.0 +/- 1.0 and 10.7 +/- 1.2, respectively), whereas losartan (14 rats) at the dose of 160 ng totally blocked (13.7 +/- 1.0 vs 7.6 +/- 1.5) the urine excretion induced by injection of 12 ng of ANG II (14 rats). [Sar(1), Ala(8)]-ANG II impaired Na+ excretion (193 +/- 16 vs 120 +/- 19): whereas [Sar(1), Thr(8)]-ANG II and losartan blocked Na+ excretion (193 +/- 16 vs 77 +/- 15 and 100 +/- 12, respectively) induced by ANG II. Similar effects induced by ANG II on K+ excretion were observed with [Sar(1), Ala(8)]-ANG II, [Sar(1), Thr(8)]-ANG II, and losartan pretreatment (133 +/- 18 vs 108 +/- 11, 80 +/- 12, and 82 +/- 15, respectively). The same doses as above of [Sar(1), Ala(8)]-ANG II (8 rats), [Sar(1), Thr(8)]-ANG II (8 rats). and losartan (9 rats) blocked the increase in the arterial blood pressure induced by 12 ng of ANG II (12 rats) (32 +/- 4 ru 4 +/- 2, 3.5 +/- 1, and 2 +/- 1: respectively. The results indicate that the AT1 receptor subtype participates in the increases of diuresis, natriuresis. kaliuresis and arterial blood pressure induced by the administration of ANG II into the MnPO.
Resumo:
Purpose: To compare a single intraoperative sub-Tenon's capsule triamcinolone acetonicle injection with steroid drops in the treatment of ocular inflammation after cataract surgery.Design: Randomized, double-masked controlled trial.Participants: A total of 100 patients were randomized prospectively into 2 groups: 50 patients treated with 1% prednisolone eyedrops (control group A) and 50 patients treated with sub-Tenon's capsule triamcinolone (treatment group B).Methods: All patients underwent phacoemulsification and intraocular posterior lens implantation. After surgery, patients were randomized to receive either (group B) an intraoperative 40 mg triamcinolone acetonicle sub-Tenon's capsule injection or (group A) 1% prednisolone acetate eyedrops, according to the following schedule: 1 drop 4 times daily (week 1), 3 times daily (week 2), 2 times daily (week 3), once daily (week 4). To mask the study, group B received vehicle drops administered on a similar schedule, and group A received an intraoperative sub-Tenon's capsule injection of a 1 ml balanced salt solution.Main Outcome Measures: the main outcome measures included inflammation (cell, flare, ciliary flush), intraocular pressure, and lack of response.Results: Triamcinolone was shown to have anti-inflammatory efficacy clinically equivalent to conventional 1% prednisolone eyedrops in reducing intraocular inflammation, as measured by clinical methods. Triamcinolone was found to be as safe as the prednisolone in terms of adverse effects, changes in visual acuity, intraocular pressure, and biomicroscopic and ophthalmoscopic variables. on the third, seventh, fourteenth, and twenty-eighth postoperative days, a significantly lower intraocular pressure (P<0.01) was noted in the triamcinolone group than in the prednisolone group.Conclusions: A single intraoperative 40-mg triamcinolone acetonide sub-Tenon's capsule injection demonstrated a clinically equivalent therapeutic response and ocular tolerance compared with 1% prednisolone drops in controlling postoperative inflammation after uncomplicated cataract surgery and merits further investigation. (C) 2004 by the American Academy of Ophthalmology.
Resumo:
A rapid and simple method for procaine determination was developed by flow injection analysis (FIA) using a screen-printed carbon electrode (SPCE) as amperometric detector. The present method is based on the amine/hydroxylamine oxidation from procaine monitored at 0.80 V on SPCE in sodium acetate solution pH 6.0. Using the best experimental conditions assigned as: pH 6.0, flow rate of 3.8 mL min(-1), sample volume of 100 mu L and analytical path of 30 cm it is possible to construct a linear calibration curve from 9.0 x 10(-6) to 1.0 x 10(-4) mol L-1. The relative standard deviation for 5.0 x 10(-5) mol L-1 procaine (15 repetitions using the same electrode) is 3.2% and detection limit calculated is 6.0 x 10(-6) mol L-1. Recoveries obtained for procaine gave a mean values from 94.8 to 102.3% and an analytical frequency of 36 injections per hour was achieved. The method was successfully applied for the determination of procaine in pharmaceutical formulation without any pre-treatment, which are in good accordance with the declared values of manufacturer and an official method based on spectrophotometric analysis. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
The study of the influence of motion and initial intra-articular pressure (IAP) on intra-articular pressure profiles in equine cadaver metatarsophalangeal (MTP) joints was undertaken as a prelude to in vivo studies, Eleven equine cadaver MTP joints were submitted to 2 motion frequencies of 5 and 10 cycles/min of flexion and extension, simulating the condition of lower and higher (double) rates of passive motion. These frequencies were applied and pressure profiles generated with initial normal intra-articular pressure (-5 mmHg) and subsequently 30 mmHg intra-articular pressure obtained by injection of previously harvested synovial fluid.The 4 trials performed were 1) normal IAP; 5 cyles/min; 2) normal IAP; 10 cycles/min; 3) IAP at 30 mmHg; 5 cycles/min and 4) IAP at 30 mmHg; 10 cycles/min. The range of joint motion applied (mean +/- s.e.) was 67.6 +/- 1.61 degrees with an excursion from 12.2 +/- 1.2 degrees in extension to 56.2 +/- 2.6 degrees in flexion, Mean pressure recorded in mmHg for the first and last min of each trial, respectively, were 1) -5.7 +/- 0.9 and -6.3 +/- 1.1; 2) -5.3 +/- 1.1 and -6.2 +/- 1.1; 3) 58.8 +/- 8.0 and 42.3 +/- 7.2; 4) 56.6 +/- 3.7 and 40.3 +/- 4.6. Statistical analyses showed a trend for difference between the values for the first and last minute in trial 3 (0.05>P<0.1) with P = 0.1 and significant difference (P = 0.02) between the mean IAP of the first and last min in trial 4. The loss of intra-articular pressure associated with time and motion was 10.5, 16.9, 28.1 and 28.9% for trials 1-4, respectively. As initial intraarticular pressure and motion increased, the percent loss of intra-articular pressure increased.The angle of lowest pressure was 12.2 +/- 1.2
Resumo:
A method based an ion exchange(IE)-atomic absorption spectrometry(AAS) coupled by flow techniques, allowing the determination of formation constants of, at least, the first species of complex systems, in aqueous solution, was developed.The IE-AAS coupling reduces significantly the number of experimental steps in comparison with IE batch methods, resulting in an important increase in analytical rate. The method is simple both from experimental and computational points of view, making possible its utilization by workers without special expertise in the field of complex equilibria in solution. on the other hand, taking into account mainly the amount of hollow cathode lamps available to date, the developed procedure may be applied, within certain limitations, to the study of many systems whose features prevent the use of traditional approaches.
Resumo:
An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.
Resumo:
This work describes an efficient, fast, and reliable analytical methodology for mercury determination in urine samples using stripping chronopotentiometry at gold film electrodes. The samples were sonicated in the presence of concentrated HCl and H2O2 for 15 min in order to disrupt the organic ligands and release the mercury. Thirty samples can be treated over the optimized region of the ultrasonic bath. This sample preparation was enough to allow the accurate stripping chronopotentiometric determination of mercury in the treated samples. No background currents and no passivation of the gold film electrode due to the sample matrix were verified. The samples were also analyzed by cold vapour atomic absorption spectrometry (CV-AAS) and good agreement between the results was verified. The analysis of NIST SRM 2670 (Toxic Metals in Freeze-Dried Urine) also validated the proposed electroanalytical method. Finally, this method was applied for mercury evaluation in urine of workers exposed to hospital waste incinerators. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
A method was developed using the multi-element graphite furnace atomic absorption spectrometry technique for the direct and simultaneous determination of As, Cu, and Pb in Brazilian sugar cane spirit (cachaqa) samples. Also employed was the end-capped transversely heated graphite atomizer (THGA) with platforms pre-treated with W permanent modifier and co-injection of Pd/Mg(NO3)(2). Pyrolysis and atomization temperature curves were established in a cachaqa medium (1+1; v/v) containing 0.2% (v/v) HNO3 and spiked with 20 mu g L-1 As and Pb and 200 mu g L-1 Cu. The effect of the concentration of major elements usually present in cachaqa matrices (Ca, Mg, Na, and K) and ethanol on the absorbance of As, Cu, and Pb was investigated. Analytical working solutions of As, Cu, and Pb were prepared in 10% (v/v) ethanol plus 5.0 mg L-1 Ca, Mg, Na, and K. Acidified to 0.2% (v/v) HNO3, these solutions were suitable to build calibration curves by matrix matching. The proposed method was applied to the simultaneous determination of As, Cu, and Pb in commercial sugar cane spirits. The characteristic mass for the simultaneous determination was 16 pg As, 119 pg Cu, and 28 pg Pb. The pretreated tube lifetime was about 450 firings. The limit of detection (LOD) was 0.6 mu g L-1 As, 9.2 mu g L-1 Cu, and 0.3 pig L-1 Pb. The found concentrations varied from 0.81 to 4.28 mu g L-1 As, 0.28 to 3.82 mg L-1 Cu and 0.82 to 518 mu g L-1 Pb. The recoveries of the spiked samples varied from 94-112% (As), 97-111% (Cu), and 95-101% (Pb). The relative standard deviation (n=12) was 6.9%, 7.4%, and 7.7% for As, Cu, and Pb, respectively, present in a sample at 0.87 mu g L-1, 0.81 mg L-1, and 38.9 mu g L-1 concentrations.
Resumo:
The changes of arterial pressure promoted by bolus injection of 50 mg phenylephrine (PHE) were studied in 20 atropinized patients (5 normal subjects, 13 patients with mitral valve disease, 1 patient with essential arterial hypertension and 1 patient with hypertrophic cardiomyopathy) submitted to routine catheterism. Patients with aortic valve disease, left ventricular outflow tract obstruction and intracardiac shunt were excluded from the study. All patients were in sinus rhythm, without heart failure. Arterial pressure started to increase at 14.8 +/- 5.4 s (range, 5.6 to 27 s; mean +/- SD) after PHE. There was an increase of 37.8 +/- 16.7 mmHg (range, 12.5 to 70 mmHg) in systolic pressure and of 26.6 +/- 11.1 mmHg (range, 7.5 to 42.5 mmHg) in diastolic pressure. Peak hypertension was attained at 36.6 +/- 16.4 s (range, 10.8 to 64.9 s) and hypertension continued for 176 +/- 92 s (range, 11 to 365 s). Heart rate was 114 +/- 21 bpm before PHE and 111 +/- 21 bpm (P<0.05) after PHE. There were no adverse events associated with intravenous PHE injection in any patient, in accordance with the general view that bolus injection of PHE is a safe and practical maneuver to promote arterial hypertension.
Resumo:
Bismuth was evaluated as an internal standard for the direct determination of Pb in vinegar by graphite furnace atomic absorption spectrometry using Ru as a permanent modifier with co-injection of Pd/Mg(NO3)(2). The correlation coefficient of the graph plotted from the non-nalized absorbance signals of Bi versus Pb was r=0.989. Matrix effects were evaluated by analyzing the slope ratios between the analytical curve, and analytical curves obtained from Pb additions in red and white wine vinegar obtained from reference solutions prepared in 0.2% (v/v) HNO3, samples. The calculated ratios were around 1.04 and 1.02 for analytical curves established applying an internal standard and 1.3 and 1.5 for analvtical curves without. Analytical curves in the 2.5-15 pg L-1 Pb concentration interval were established using the ratio Pb absorbance to Bi absorbance versus analvte concentration, and typical linear correlations of r=0.999 were obtained. The proposed method was applied for direct determination of Pb in 18 commercial vinegar samples and the Pb concentration varied from 2.6 to 31 pg L-1. Results were in agreement at a 95% confidence level (paired t-test) with those obtained for digested samples. Recoveries of Pb added to vinegars varied from 96 to 108% with and from 72 to 86% without an internal standard. Two water standard reference materials diluted in vinegar sample were also analyzed and results were in agreement with certified values at a 95% confidence level. The characteristic mass was 40 pg Pb and the useful lifetime of the tube was around 1600 firings. The limit of detection was 0.3 mu g L-1 and the relative standard deviation was <= 3.8% and <= 8.3% (n = 12) for a sample containing, 10 mu L-1 Pb with and without internal standard, respectively. (C) 2007 Elsevier B.V. All rights reserved.
Resumo:
Micro-scale (sub-pmol) isolation and sequence determination of three peptides from the venom of the solitary spider wasp Cyphononyx dorsalis is described. We isolated two novel peptides Cd-125 and Cd-146 and a known peptide Thr(6)-bradykinin from only two venom sacs of solitary spider wasp Cyphononyx dorsalis without bioassay-guided fractionation. but instead guided by MALDI-TOF MS. The MALDI-TOF MS analysis of each fraction showed the purity and molecular weight of the components, which led to the isolation of the peptides virtually without loss of sample amount. The sequences of the novel peptides Cd-125 (Asp-Thr-Ala-Arg-Leu-Lys-Trp-His) and Cd-146 (Ser-Glu-Thr-Gly-Asn-Thr-Val-Thr-Val-Lys-Gly-Phe-Ser-Pro-Leu-Arg) were determined by Edman degradation together with mass spectrometry. and finally corroborated by solid-phase synthesis. The known peptide Thr(6)-bradykinin (Arg-Pro-Pro-Gly-Phe-Thr-Pro-Phe-Arg) was identified by comparison with the synthetic authentic specimen. This is the first example for any kinins to be found in Pompilidae wasp venoms. The procedure reported here can be applicable to studies on many other components of solitary wasp venoms with limited sample availability. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Cardiovascular responses to central losartan (LOS), a non-peptide angiotensin II (ANG II) receptor antagonist, were investigated by comparing the effects of LOS injection into the 3rd and 4th cerebral ventricles (3rdV, 4thV) on mean arterial pressure (MAP) and heart rate (HR). Adult male Holtzman rats were used (N = 6 animals per group). Average basal MAP and HR were 114 +/- 3 mmHg and 343 +/- 9 bpm (N = 23), respectively. LOS (50, 100 or 200 nmol/2 mu l) injected into the 3rdV induced presser (peak of 25 +/- 3 mmHg) and tachycardic (peak of 60 +/- 25 bpm) responses. LOS injected into the 4thV had no effect on MAP, but it induced bradycardia (peak of -35 +/- 15 bpm). KCl (200 nmol/2 mu l) injected into the 3rdV or into the 4thV had no effect on either MAP or HR compared to 0.9% saline injection. The results indicate that LOS injected into the third ventricle acts on forebrain structures to induce its presser and tachycardic effects and that bradycardia, likely dependent on hindbrain structures, is obtained when LOS is injected into the fourth ventricle.
Resumo:
A reversible intermittent pow-injection procedure is proposed for the automated determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry, CVAAS. Solutions of sample and stannous chloride are carried by two air streams and sequentially injected into the generator/separator chamber in a segmented asynchronous merging zone configuration. The intermittent flow in the forward direction carries the mercury vapor through the flow cell, and in the backward direction, if aspirates the the remaining solution from the vessel to waste. We investigated composition and concentration of reagents, pow rates, commutation times, reactor configuration, and conditions for mercury release. The accuracy was checked by mercury determination in a certified sediment and spiked vinasses and river waters. The system handles about 100 samples per hour (0.50-5.00 mu g L-1), consuming ca. 2.5 mL of sample and 50 mg of SnCl2 per determination; Good recoveries (92-103%) were obtained with spiked samples. Results are precise (RSD <3% for 2.5 mu g Hg L-1, n = 12) and in agreement with values for certified reference material at 95% confidence level. (C) 1999 John Wiley & Sons, Inc.
Resumo:
Postweld heat treatment (PWHT) is frequently applied to steel pressure vessels, following the requirements of the ASME code (section VIII), which establishes the parameters of the PWHT based on the thickness and chemical composition of the welded section. This work shows the results of an analysis undertaken on a sample of ASTM A537 C1 steel subjected to qualifying welding procedure tests including PWHT (650 degreesC/5 h), the results obtained showed that this PWHT practice promoted a reduction in the mechanical properties of the base metal and the heat-affected zone (HAZ).
Resumo:
A sensor based on graphite electrode modified with palladium-platinum-palladium film is proposed for phosphite determination by flow-injection amperometry. The modified electrode was prepared by a sequential cathodic deposition of Pd, Pt and Pd on a graphite electrode from 0.5% m/v PdCl2 + 28% m/v NH4OH and 2% m/v H2PtCl6 + 10% v/v H2SO4 solutions. After suitable conditioning, the electrode showed catalytic activity for phosphite oxidation when 0. 15 V was applied. The proposed system handles approximately 50 samples per hour (0.0.1 - 0.05 mol L-1 Na-2 HPO3; R-2 = 0.9997), consuming ca. 70 mu L of sample per determination. The limit of detection and amperometric sensibility were 5 X 10(-4) mol L-1 and 1.5 mA L mol(-1), respectively. The proposed method was applied to analysis of fertilizer samples without pre-treatment. Results are in agreement with those obtained by spectrophotometry and titrimetry at 95% confidence level and good recoveries (96-109%) of spiked samples were found. Relative standard deviation (n=12) of a 0.01 mol L-1 Na2HPO3 sample was 2%. The useful lifetime of modified electrode was around 220 determinations. For routine purposes it means that this electrode can be continuously used for 5 hours.