916 resultados para peripheral venous catheters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Cold atmospheric plasma (CAP, i.e. ionized air) is an innovating promising tool in reducing bacteria. OBJECTIVE We conducted the first clinical trial with the novel PlasmaDerm(®) VU-2010 device to assess safety and, as secondary endpoints, efficacy and applicability of 45 s/cm(2) cold atmospheric plasma as add-on therapy against chronic venous leg ulcers. METHODS From April 2011 to April 2012, 14 patients were randomized to receive standardized modern wound care (n = 7) or plasma in addition to standard care (n = 7) 3× per week for 8 weeks. The ulcer size was determined weekly (Visitrak(®) , photodocumentation). Bacterial load (bacterial swabs, contact agar plates) and pain during and between treatments (visual analogue scales) were assessed. Patients and doctors rated the applicability of plasma (questionnaires). RESULTS The plasma treatment was safe with 2 SAEs and 77 AEs approximately equally distributed among both groups (P = 0.77 and P = 1.0, Fisher's exact test). Two AEs probably related to plasma. Plasma treatment resulted in a significant reduction in lesional bacterial load (P = 0.04, Wilcoxon signed-rank test). A more than 50% ulcer size reduction was noted in 5/7 and 4/7 patients in the standard and plasma groups, respectively, and a greater size reduction occurred in the plasma group (plasma -5.3 cm(2) , standard: -3.4 cm(2) ) (non-significant, P = 0.42, log-rank test). The only ulcer that closed after 7 weeks received plasma. Patients in the plasma group quoted less pain compared to the control group. The plasma applicability was not rated inferior to standard wound care (P = 0.94, Wilcoxon-Mann-Whitney test). Physicians would recommend (P = 0.06, Wilcoxon-Mann-Whitney test) or repeat (P = 0.08, Wilcoxon-Mann-Whitney test) plasma treatment by trend. CONCLUSION Cold atmospheric plasma displays favourable antibacterial effects. We demonstrated that plasma treatment with the PlasmaDerm(®) VU-2010 device is safe and effective in patients with chronic venous leg ulcers. Thus, larger controlled trials and the development of devices with larger application surfaces are warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Assessment of endothelial function of the microvasculature by peripheral arterial tonometry (EndoPAT(®)) has gained increasing popularity in patients with cardiovascular risk factors. Only limited knowledge about its reproducibility in patients with coronary artery disease (CAD) is available. We therefore aimed to quantify reproducibility of EndoPAT(®) parameters in patients with stable CAD. DESIGN EndoPAT(®) measurements were performed repeatedly in 78 male patients (age 66 ± 8 years) with CAD on stable medication. We calculated overall mean, standard deviation (SD), coefficient of variation (CV) and intraclass correlation coefficient (ICC) of the following parameters: reactive hyperemic index (RHI), PAT ratio of the postocclusion period 90-150 s as used for calculation of the RHI (PAT ratio90-150 s) and 90-120 s (PAT ratio90-120 s) as used for the often employed Framingham RHI (F-RHI), as well as PAT ratio of the peak hyperemic response (PAT ratiopeak response). Additionally, least significant changes (LSC) for individual subjects and minimum sample sizes for parallel and cross-over design studies were calculated. RESULTS Mean RHI was 1·84 (SD 0·36). For RHI, PAT ratio90-150 s , PAT ratio90-120 s , and PAT ratiopeak response the CVs were 17·0%, 25·4%, 26·1%, and 25·0%, respectively. The ICCs were 0·45, 0·49, 0·48 and 0·51, respectively, and LSC for RHI was 47·2%. CONCLUSIONS CV of RHI in our population was moderate; however, we consider this precision insufficient to monitor changes in individual patients, as they would need to exceed 47% to show a significant change. Further, the poor ICCs reflect the difficulty of detecting treatment effects in homogenous populations, such as patients with stable CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Polypharmacy, defined as the concomitant use of multiple medications, is very common in the elderly and may trigger drug-drug interactions and increase the risk of falls in patients receiving vitamin K antagonists. OBJECTIVE To examine whether polypharmacy increases the risk of bleeding in elderly patients who receive vitamin K antagonists for acute venous thromboembolism (VTE). DESIGN We used a prospective cohort study. PARTICIPANTS In a multicenter Swiss cohort, we studied 830 patients aged ≥ 65 years with VTE. MAIN MEASURES We defined polypharmacy as the prescription of more than four different drugs. We assessed the association between polypharmacy and the time to a first major and clinically relevant non-major bleeding, accounting for the competing risk of death. We adjusted for known bleeding risk factors (age, gender, pulmonary embolism, active cancer, arterial hypertension, cardiac disease, cerebrovascular disease, chronic liver and renal disease, diabetes mellitus, history of major bleeding, recent surgery, anemia, thrombocytopenia) and periods of vitamin K antagonist treatment as a time-varying covariate. KEY RESULTS Overall, 413 (49.8 %) patients had polypharmacy. The mean follow-up duration was 17.8 months. Patients with polypharmacy had a significantly higher incidence of major (9.0 vs. 4.1 events/100 patient-years; incidence rate ratio [IRR] 2.18, 95 % confidence interval [CI] 1.32-3.68) and clinically relevant non-major bleeding (14.8 vs. 8.0 events/100 patient-years; IRR 1.85, 95 % CI 1.27-2.71) than patients without polypharmacy. After adjustment, polypharmacy was significantly associated with major (sub-hazard ratio [SHR] 1.83, 95 % CI 1.03-3.25) and clinically relevant non-major bleeding (SHR 1.60, 95 % CI 1.06-2.42). CONCLUSIONS Polypharmacy is associated with an increased risk of both major and clinically relevant non-major bleeding in elderly patients receiving vitamin K antagonists for VTE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Whether or not a high risk of falls increases the risk of bleeding in patients receiving anticoagulants remains a matter of debate. METHODS We conducted a prospective cohort study involving 991 patients ≥ 65 years of age who received anticoagulants for acute venous thromboembolism (VTE) at nine Swiss hospitals between September 2009 and September 2012. The study outcomes were as follows: the time to a first major episode of bleeding; and clinically relevant nonmajor bleeding. We determined the associations between the risk of falls and the time to a first episode of bleeding using competing risk regression, accounting for death as a competing event. We adjusted for known bleeding risk factors and anticoagulation as a time-varying covariate. RESULTS Four hundred fifty-eight of 991 patients (46%) were at high risk of falls. The mean duration of follow-up was 16.7 months. Patients at high risk of falls had a higher incidence of major bleeding (9.6 vs. 6.6 events/100 patient-years; P = 0.05) and a significantly higher incidence of clinically relevant nonmajor bleeding (16.7 vs. 8.3 events/100 patient-years; P < 0.001) than patients at low risk of falls. After adjustment, a high risk of falls was associated with clinically relevant nonmajor bleeding [subhazard ratio (SHR) = 1.74, 95% confidence interval (CI) = 1.23-2.46], but not with major bleeding (SHR = 1.24, 95% CI = 0.83-1.86). CONCLUSION In elderly patients who receive anticoagulants because of VTE, a high risk of falls is significantly associated with clinically relevant nonmajor bleeding, but not with major bleeding. Whether or not a high risk of falls is a reason against providing anticoagulation beyond 3 months should be based on patient preferences and the risk of VTE recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study was to investigate the survival effects of inferior vena cava filters in patients with venous thromboembolism (VTE) who had a significant bleeding risk. BACKGROUND The effectiveness of inferior vena cava filter use among patients with acute symptomatic VTE and known significant bleeding risk remains unclear. METHODS In this prospective cohort study of patients with acute VTE identified from the RIETE (Computerized Registry of Patients With Venous Thromboembolism), we assessed the association between inferior vena cava filter insertion for known significant bleeding risk and the outcomes of all-cause mortality, pulmonary embolism (PE)-related mortality, and VTE rates through 30 days after the initiation of VTE treatment. Propensity score matching was used to adjust for the likelihood of receiving a filter. RESULTS Of the 40,142 eligible patients who had acute symptomatic VTE, 371 underwent filter placement because of known significant bleeding risk. A total of 344 patients treated with a filter were matched with 344 patients treated without a filter. Propensity score-matched pairs showed a nonsignificant trend toward lower risk of all-cause death for filter insertion compared with no insertion (6.6% vs. 10.2%; p = 0.12). The risk-adjusted PE-related mortality rate was lower for filter insertion than no insertion (1.7% vs. 4.9%; p = 0.03). Risk-adjusted recurrent VTE rates were higher for filter insertion than for no insertion (6.1% vs. 0.6%; p < 0.001). CONCLUSIONS In patients presenting with VTE and with a significant bleeding risk, inferior vena cava filter insertion compared with anticoagulant therapy was associated with a lower risk of PE-related death and a higher risk of recurrent VTE. However, study design limitations do not imply a causal relationship between filter insertion and outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Venous thromboembolism (VTE) is a potentially lethal clinical condition that is suspected in patients with common clinical complaints, in many and varied, clinical care settings. Once VTE is diagnosed, optimal therapeutic management (thrombolysis, IVC filters, type and duration of anticoagulants) and ideal therapeutic management settings (outpatient, critical care) are also controversial. Clinical prediction tools, including clinical decision rules and D-Dimer, have been developed, and some validated, to assist clinical decision making along the diagnostic and therapeutic management paths for VTE. Despite these developments, practice variation is high and there remain many controversies in the use of the clinical prediction tools. In this narrative review, we highlight challenges and controversies in VTE diagnostic and therapeutic management with a focus on clinical decision rules and D-Dimer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Type 2 diabetes mellitus and pre-diabetes are risk factors for atherosclerosis and are highly prevalent in patients with coronary artery disease. However, the prevalence of impaired glucose metabolism in patients with peripheral artery disease is not as well elucidated. We aimed at comparing prevalence rates of type 2 diabetes mellitus and pre-diabetes, which were diagnosed according to the current American Diabetes Association criteria, among 364 patients with peripheral artery disease, 529 patients with coronary artery disease and 383 controls. The prevalence of type 2 diabetes mellitus in peripheral artery disease patients was 49.7%. It was significantly higher in these patients than in coronary artery disease patients (34.4%; p < 0.001) and controls (21.4%; p < 0.001). Adjusted for sex, age and body mass index, odds ratios for type 2 diabetes mellitus were 2.0 (95% confidence interval 1.5-2.6) comparing the peripheral artery disease group with the coronary artery disease group (p < 0.001) and 4.0 (2.8-5.8) comparing the peripheral artery disease group with controls (p < 0.001). The prevalence of pre-diabetes among non-diabetic subjects was high in all three study groups (64.5% in peripheral artery disease patients, 63.4% in coronary artery disease patients and 61.8% in controls), without significant between-group differences. In conclusion, the prevalence of type 2 diabetes mellitus is even higher in peripheral artery disease patients than in coronary artery disease patients. This observation underlines the need to consider impaired glucose regulation in the management of peripheral artery disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The knowledge on the level of systemic inflammation in peripheral artery disease (PAD) is less well established than that in coronary artery disease (CAD). Systemic inflammation frequently coincides with atherosclerosis, but also with various traits of the metabolic syndrome (MetS). The individual contribution of CAD, PAD, and the MetS to inflammation is not known. METHODS We enrolled a total of 1396 patients, 460 patients with PAD Fontaine stages IIa-IV verified by duplex ultrasound (PAD group) and 936 patients free of limb claudication undergoing coronary angiography, of whom 507 had significant CAD with coronary stenoses ≥50% (CAD group), and 429 did not have significant CAD at angiography (control group). RESULTS C-reactive protein (CRP) was significantly higher in the PAD than in the CAD or in the control group (0.86 ± 1.85 mg/dl versus 0.44 ± 0.87 mg/dl and 0.39 ± 0.52 mg/dl, respectively, p < 0.001 for both comparisons). These significant differences were confirmed when patients with and subjects without the MetS were analyzed separately. In particular, within the PAD group, CRP was significantly higher in patients with the MetS than in subjects without the MetS (1.04 ± 2.01 vs. 0.67 ± 1.64 mg/dl; p = 0.001) and both, the presence of PAD and the MetS proved to be independently associated with CRP in analysis of covariance (F = 31.84; p < 0.001 and F = 10.52; p = 0.001, respectively). CONCLUSION Inflammatory activity in PAD patients is higher than in CAD patients and is particularly high in PAD patients affected by the MetS. Low grade systemic inflammation is independently associated with both the MetS and PAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Bolt-kit systems are increasingly used as an alternative to conventional external cerebrospinal fluid (CSF) drainage systems. Since 2009 we regularly utilize bolt-kit external ventricular drainage (EVD) systems with silver-bearing catheters inserted manually with a hand drill and skull screws for emergency ventriculostomy. For non-emergency situations, we use conventional ventriculostomy with subcutaneous tunneled silver-bearing catheters, performed in the operating room with a pneumatic drill. This retrospective analysis compared the two techniques in terms of infection rates. METHODS 152 patients (aged 17-85 years, mean=55.4 years) were included in the final analysis; 95 received bolt-kit silver-bearing catheters and 57 received conventionally implanted silver-bearing catheters. The primary endpoint combined infection parameters: occurrence of positive CSF culture, colonization of catheter tips, or elevated CSF white blood cell counts (>4/μl). Secondary outcome parameters were presence of microorganisms in CSF or on catheter tips. Incidence of increased CSF cell counts and number of patients with catheter malposition were also compared. RESULTS The primary outcome, defined as analysis of combined infection parameters (occurrence of either positive CSF culture, colonization of the catheter tips or raised CSF white blood cell counts >4/μl)was not significantly different between the groups (58.9% bolt-kit group vs. 63.2% conventionally implanted group, p=0.61, chi-square-test). The bolt-kit group was non-inferior and not superior to the conventional group (relative risk reduction of 6.7%; 90% confidence interval: -19.9% to 25.6%). Secondary outcomes showed no statistically significant difference in the incidence of microorganisms in CSF (2.1% bolt-kit vs. 5.3% conventionally implanted; p=0.30; chi-square-test). CONCLUSIONS This analysis indicates that silver-bearing EVD catheters implanted with a bolt-kit system outside the operating room do not significantly elevate the risk of CSF infection as compared to conventional implant methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Blood loss and blood substitution are associated with higher morbidity after major abdominal surgery. During major liver resection, low local venous pressure, has been shown to reduce blood loss. Ambiguity persists concerning the impact of local venous pressure on blood loss during open radical cystectomy. We aimed to determine the association between intraoperative blood loss and pelvic venous pressure (PVP) and determine factors affecting PVP. MATERIAL AND METHODS In the frame of a single-center, double-blind, randomized trial, PVP was measured in 82 patients from a norepinephrine/low-volume group and in 81 from a control group with liberal hydration. For this secondary analysis, patients from each arm were stratified into subgroups with PVP <5 mmHg or ≥5 mmHg measured after cystectomy (optimal cut-off value for discrimination of patients with relevant blood loss according to the Youden's index). RESULTS Median blood loss was 800 ml [range: 300-1600] in 55/163 patients (34%) with PVP <5 mmHg and 1200 ml [400-3000] in 108/163 patients (66%) with PVP ≥5 mmHg; (P<0.0001). A PVP <5 mmHg was measured in 42/82 patients (51%) in the norepinephrine/low-volume group and 13/81 (16%) in the control group (P<0.0001). PVP dropped significantly after removal of abdominal packing and abdominal lifting in both groups at all time points (at begin and end of pelvic lymph node dissection, end of cystectomy) (P<0.0001). No correlation between PVP and central venous pressure could be detected. CONCLUSIONS Blood loss was significantly reduced in patients with low PVP. Factors affecting PVP were fluid management and abdominal packing.