897 resultados para patent sequence datasets


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spinal muscular atrophy (SMA) is a lethal hereditary disease caused by homozygous deletion/inactivation of the survival of motoneuron 1 (SMN1) gene. The nearby SMN2 gene, despite its identical coding capacity, is only an incomplete substitute, because a single nucleotide difference impairs the inclusion of its seventh exon in the messenger RNA (mRNA). This splicing defect can be corrected (transiently) by specially designed oligonucleotides. Here we have developed a more permanent correction strategy based on bifunctional U7 small nuclear RNAs (snRNAs). These carry both an antisense sequence that allows specific binding to exon 7 and a splicing enhancer sequence that will improve the recognition of the targeted exon. When expression cassettes for these RNAs are stably introduced into cells, the U7 snRNAs become incorporated into small nuclear ribonucleoprotein (snRNP) particles that will induce a durable splicing correction. We have optimized this strategy to the point that virtually all SMN2 pre-mRNA becomes correctly spliced. In fibroblasts from an SMA patient, this approach induces a prolonged restoration of SMN protein and ensures its correct localization to discrete nuclear foci (gems).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen-sensitive 3He-MRI was studied for the detection of differences in intrapulmonary oxygen partial pressure (pO2) between patients with normal lung transplants and those with bronchiolitis obliterans syndrome (BOS). Using software developed in-house, oxygen-sensitive 3He-MRI datasets from patients with normal lung grafts (n = 8) and with BOS (n = 6) were evaluated quantitatively. Datasets were acqiured on a 1.5-T system using a spoiled gradient echo pulse sequence. Underlying diseases were pulmonary emphysema (n = 10 datasets) and fibrosis (n = 4). BOS status was verified by pulmonary function tests. Additionally, 3He-MRI was assessed blindedly for ventilation defects. Median intrapulmonary pO2 in patients with normal lung grafts was 146 mbar compared with 108 mbar in patients with BOS. Homogeneity of pO2 distribution was greater in normal grafts (standard deviation pO2 34 versus 43 mbar). Median oxygen decrease rate during breath hold was higher in unaffected patients (-1.75 mbar/s versus -0.38 mbar/s). Normal grafts showed fewer ventilation defects (5% versus 28%, medians). Oxygen-sensitive 3He-MRI appears capable of demonstrating differences of intrapulmonary pO2 between normal lung grafts and grafts affected by BOS. Oxygen-sensitive 3He-MRI may add helpful regional information to other diagnostic techniques for the assessment and follow-up of lung transplant recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To determine quantitative and qualitative image quality in patients undergoing magnetic resonance (MR) cholangiography at 3.0 Tesla (T) compared with 1.5 T. MATERIALS AND METHODS: Fifty patients (30 women; mean age, 51 years) underwent MR cholangiography at 1.5 T; another 50 patients (25 women; mean age 51 years) were scanned at 3.0 T. MR sequence protocol consisted of breath-hold single-slice rapid acquisition with relaxation enhancement (RARE) and a respiratory-triggered 3D turbo spin echo (3D TSE) sequence. Maximum intensity projections were generated from the 3D TSE datasets. Contrast-to-noise ratio (CNR) measurements between the common bile duct (CBD), left and right intrahepatic duct (LHD, RHD), and periductal tissue were performed. Three radiologists assessed qualitatively the visibility of the CBD, LHD, and RHD and the overall diagnostic quality. RESULTS: Mean gain in CNR at 3.0 T versus 1.5 T in all 3 locations ranged for the RARE sequence from 7.7% to 38.1% and for the 3D TSE from 0.5% to 26.1% (P > 0.05 for all differences). Qualitative analysis did not reveal any significant difference between the 2 field strengths (P > 0.05). CONCLUSIONS: MR cholangiography at 3.0 T shows a trend toward higher CNR without improving image quality significantly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This randomized trial compared procedural complications and 30-day clinical outcomes of 3 patent foramen ovale (PFO) closure devices (Amplatzer, Helex, and CardioSEAL-STARflex). It examined 660 patients (361 men, 299 women, mean age 49.3+/-1.9 years), with 220 patients per group. All patients had a history of paradoxical embolism. All PFO closures were successful technically. Exchange of devices for others was most frequently required for the Helex occluder (7 of 220) and 2 of 220 in either of the other groups. Three device embolizations in the Helex group were retrieved and replaced successfully. One patient with a Helex occluder developed a transient ischemic attack and recovered without treatment. A hemopericardium in that group was punctured without affecting the device. One tamponade in the Amplatzer group required surgical device explantation. In 8 of 660 patients in the CardioSEAL-STARflex group, thrombi resolved after anticoagulation. Sixteen patients (11 in the CardioSEAL-STARflex group, 3 in the Amplatzer group, and 2 in the Helex group) had episodes of atrial fibrillation. PFOs were closed completely in 143 of 220 patients (65%) in the Amplatzer group, 116 of 220 patients (52.7%) in the Helex group, and 137 of 220 patients (62.3%) in the CardioSEAL-STARflex group at 30 days with significant differences between the Helex and Amplatzer occluders (p=0.0005) and the Helex and CardioSEAL-STARflex occluders (p=0.0003). PFO closure can be performed safely with each device. In conclusion, the Helex occluder embolized more frequently. Device thrombus formation and paroxysmal atrial fibrillation were more common with the CardioSEAL-STARflex occluder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Recurrent embolic events after device closure of patent foramen ovale (PFO) have been related to incomplete closure. Another cause could be atrial fibrillation (AF). The aim of this study was to determine the incidence of AF in stroke patients after PFO closure. METHODS: Consecutive patients with device closure of a PFO after a stroke or transient ischemic attack and control patients with stroke underwent 7-day event loop recordings 3 and 6 months after PFO closure or stroke, respectively. RESULTS: Forty patients treated by PFO device closure 96 +/- 68 days after cryptogenic ischemic stroke and 70 control patients with ischemic stroke of other etiologies (known AF excluded) were compared. AF was identified in 6 patients (15%) of the treated group and in 12 control patients (17%, p = 0.77). In multivariate analysis, the presence of an occluder device was not an independent risk factor for AF. CONCLUSIONS: The incidence of AF is high after device closure of a PFO in stroke patients and similar to that in patients with stroke of non-PFO etiology and, hence, with no device. Further studies are required to determine the risk of thromboembolism and the optimal treatment in patients developing AF after device closure of a PFO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The technique of transseptal puncture for catheter ablation of atrial fibrillation after percutaneous closure of a foramen ovale with the Amplatzer Occluder is demonstrated based on 2 representative cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Patent foramen ovale (PFO) has been linked to migraine, and several retrospective studies reported an improvement in migraine prevalence or frequency after PFO closure for other reasons, mostly for secondary prevention of paradoxical embolism or following diving accidents. We investigated the outcome of patients undergoing PFO closure solely for migraine headaches refractory to medical treatment. METHODS: Seventeen patients (age 44 +/- 12 years; 76% female; one atrial septal aneurysm) underwent percutaneous PFO closure using the Amplatzer PFO Occluder (AGA Medical Corporation, Golden Valley, MN). An 18-mm device was used in two patients, a 25-mm device in 13, and a 35-mm device in two. The interventions were solely guided by fluoroscopy, without intraprocedural echocardiography. RESULTS: All implantation procedures were successful. There were no peri-procedural complications. Contrast transesophageal echocardiography after Valsalva maneuver at 6 months showed complete PFO closure in 16 patients (94%), whereas a minimal residual shunt persisted in one (6%). During 2.7 +/- 1.5 years of follow-up, no deaths and no embolic events occurred. After PFO closure, migraine headaches disappeared in four patients (24%), and improved in eight additional patients (47%). Three patients (18%) reported a decrease of their headaches by 75%, three patients (18%) a decrease of 50%, and two patients (12%) a decrease of 25%, while headaches remained unchanged in five patients (29%). No patient experienced worsening headaches. Moreover, the prevalence of migraine with aura decreased from 82 to 24% (P = 0.002). CONCLUSIONS: These results suggest that percutaneous PFO closure durably alters the spontaneous course of shunt associated migraine.