905 resultados para partial least-squares regression


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main purpose of this paper is to investigate theoretically and experimentally the use of family of Polynomial Powers of the Sigmoid (PPS) Function Networks applied in speech signal representation and function approximation. This paper carries out practical investigations in terms of approximation fitness (LSE), time consuming (CPU Time), computational complexity (FLOP) and representation power (Number of Activation Function) for different PPS activation functions. We expected that different activation functions can provide performance variations and further investigations will guide us towards a class of mappings associating the best activation function to solve a class of problems under certain criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fourteen complexes in the series [RuCl2(CO)(L)(PPh3)2] (where L = N-heterocycles) have been prepared and characterized by IR and NMR spectroscopies, and cyclic voltammetry. A good correlation is found between observed and calculated electrochemical potentials; E1/2 vs pKa or (Gp, σm for a series of similar ligands. It is now reported that the carbonyl stretching frequency, νCO, and the 13C and 31P NMR signals do not correlate well with any of the physico-chemical parameters used (E1/2, Taft's and Hammett's parameters). This behaviour is probably due to the characteristics of the Ru(II) species, which does not transmit the steric and electron donor/acceptor properties of the ligands to the carbonyl group, or because the measurements are not able to detect the effect induced by the changes in the ligand L. Indeed, good correlations are obtained when the measurements directly involve the metal centre, as is the case in the E1/2 measurements. Crystals of o[RuCl2(CO)(4-pic)(PPh3)2] are monoclinic, space group P21/n, a = 12.019(2), b = 13.825(3) and c = 22.253(3) . The structure was solved by the Patterson method and was refined by full-matrix least-squares procedure to R = 0.054 and Rw = 0.055, for 2114 reflections with I > 3σ(I). For L = 2-acetylpyridine and 2-methylimidazole, complexes with formulae [RuCl2(CO)(L)(PPh3)] · L and [RuCl2(CO)(L)2 (PPh3)], respectively, were obtained. © 1998 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the synthesis and the structural and magnetic characterization of two new compounds: dibromobis-(pdmp)copper(II), CuBr2C22H24N4 (1), and dichlorobis(pdmp)copper(II), CuCl2C22H24N4 (2), where pdmp = 1-phenyl-3,5-dimethylpyrazole. The structures were refined by full-matrix least-squares techniques to R1 = 0.0620 and 0.0777, respectively. Compound 1 belongs to the space group P21/n with a = 8.165(5) Å, b = 10.432(3) Å, c = 13.385(4) Å, β = 100.12(4)̊, and Z = 2. Compound 2 belongs to the space group P21/c with a = 8.379(2) Å, b = 22.630(2) Å, c = 12.256(2) Å, β= 98.43(3)°, and Z = 4. It has the same molecular formula as a compound reported previously but a different crystal structure. Detailed single-crystal EPR measurements were performed for single-crystal samples of 1 and 2 at 9 and 35 GHz and at room temperature. The positions and line widths of the EPR lines were measured as a function of the magnetic field orientation in three orthogonal planes. The data were used to study the electronic properties of the copper ions and to evaluate the exchange interactions between them. Our results are discussed in terms of the electronic pathways for superexchange between copper ions, which are provided by the stacking of pyrazole and phenyl rings of neighboring molecules and by hydrogen-halogen bonds. © 1999 American Chemical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Systematic errors can have a significant effect on GPS observable. In medium and long baselines the major systematic error source are the ionosphere and troposphere refraction and the GPS satellites orbit errors. But, in short baselines, the multipath is more relevant. These errors degrade the accuracy of the positioning accomplished by GPS. So, this is a critical problem for high precision GPS positioning applications. Recently, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique. It uses a natural cubic spline to model the errors as a function which varies smoothly in time. The systematic errors functions, ambiguities and station coordinates, are estimated simultaneously. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Brazilian National Institute for Space Research (INPE) is operating the Brazilian Environmental Data Collection System that currently amounts to a user community of around 100 organizations and more than 700 data collection platforms installed in Brazil. This system uses the SCD-1, SCD-2, and CBERS-2 low Earth orbit satellites to accomplish the data collection services. The main system applications are hydrology, meteorology, oceanography, water quality, and others. One of the functionalities offered by this system is the geographic localization of the data collection platforms by using Doppler shifts and a batch estimator based on least-squares technique. There is a growing demand to improve the quality of the geographical location of data collection platforms for animal tracking. This work presents an evaluation of the ionospheric and tropospheric effects on the Brazilian Environmental Data Collection System transmitter geographic location. Some models of the ionosphere and troposphere are presented to simulate their impacts and to evaluate performance of the platform location algorithm. The results of the Doppler shift measurements, using the SCD-2 satellite and the data collection platform (DCP) located in Cuiabá town, are presented and discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The GPS observables are subject to several errors. Among them, the systematic ones have great impact, because they degrade the accuracy of the accomplished positioning. These errors are those related, mainly, to GPS satellites orbits, multipath and atmospheric effects. Lately, a method has been suggested to mitigate these errors: the semiparametric model and the penalised least squares technique (PLS). In this method, the errors are modeled as functions varying smoothly in time. It is like to change the stochastic model, in which the errors functions are incorporated, the results obtained are similar to those in which the functional model is changed. As a result, the ambiguities and the station coordinates are estimated with better reliability and accuracy than the conventional least square method (CLS). In general, the solution requires a shorter data interval, minimizing costs. The method performance was analyzed in two experiments, using data from single frequency receivers. The first one was accomplished with a short baseline, where the main error was the multipath. In the second experiment, a baseline of 102 km was used. In this case, the predominant errors were due to the ionosphere and troposphere refraction. In the first experiment, using 5 minutes of data collection, the largest coordinates discrepancies in relation to the ground truth reached 1.6 cm and 3.3 cm in h coordinate for PLS and the CLS, respectively, in the second one, also using 5 minutes of data, the discrepancies were 27 cm in h for the PLS and 175 cm in h for the CLS. In these tests, it was also possible to verify a considerable improvement in the ambiguities resolution using the PLS in relation to the CLS, with a reduced data collection time interval. © Springer-Verlag Berlin Heidelberg 2007.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of the ionosphere on the signals of Global Navigation Satellite Systems (GNSS), such as the Global Positionig System (GPS) and the proposed European Galileo, is dependent on the ionospheric electron density, given by its Total Electron Content (TEC). Ionospheric time-varying density irregularities may cause scintillations, which are fluctuations in phase and amplitude of the signals. Scintillations occur more often at equatorial and high latitudes. They can degrade navigation and positioning accuracy and may cause loss of signal tracking, disrupting safety-critical applications, such as marine navigation and civil aviation. This paper addresses the results of initial research carried out on two fronts that are relevant to GNSS users if they are to counter ionospheric scintillations, i.e. forecasting and mitigating their effects. On the forecasting front, the dynamics of scintillation occurrence were analysed during the severe ionospheric storm that took place on the evening of 30 October 2003, using data from a network of GPS Ionospheric Scintillation and TEC Monitor (GISTM) receivers set up in Northern Europe. Previous results [1] indicated that GPS scintillations in that region can originate from ionospheric plasma structures from the American sector. In this paper we describe experiments that enabled confirmation of those findings. On the mitigation front we used the variance of the output error of the GPS receiver DLL (Delay Locked Loop) to modify the least squares stochastic model applied by an ordinary receiver to compute position. This error was modelled according to [2], as a function of the S4 amplitude scintillation index measured by the GISTM receivers. An improvement of up to 21% in relative positioning accuracy was achieved with this technnique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Associations between four microsatellite markers on chromosome 11 and five on chromosome 13 with performance, carcass and organs traits were investigated in chickens using a least-squares approach applied to single-marker analysis. Three hundred and twenty seven F 2 chickens from the EMBRAPA broiler×layer experimental population were evaluated for 16 traits: five related to performance, five to carcass and five to organs, plus the hematocrit. Two significance thresholds were considered: p<0.05 and p<0.0056; the last value resulted from the application of a multiple tests analyses correction. On chromosome 11, six associations (p<0.05) between the genotypes of two markers with four growth related and one carcass trait were found. On chromosome 13, six associations (p<0.05) between marker genotypes and three performance traits, eight associations (p<0.05) between marker genotypes and two carcass traits and eight associations (p<0.05) between marker genotypes and four organs traits were detected. These associations were indications of the presence of quantitative trait loci on these chromosomes, especially on chromosome 13. In this chromosome, the strongest evidence was for body weight at 41 days of age and percentage of carcass because the p-values exceeded the multiple test threshold (p<0.0056), but also for breast percentage and heart weight due to the large number of markers (four) on chromosome 13 associated with each one of these traits. These associations should be further investigated by interval mapping analyses to find QTL positions and to allow the estimation of their effects. © Asian Network for Scientific Information, 2009.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GPS active networks are more and more used in geodetic surveying and scientific experiments, as water vapor monitoring in the atmosphere and lithosphere plate movement. Among the methods of GPS positioning, Precise Point Positioning (PPP) has provided very good results. A characteristic of PPP is related to the modeling and / or estimation of the errors involved in this method. The accuracy obtained for the coordinates can reach few millimeters. Seasonal effects can affect such accuracy if they are not consistent treated during the data processing. Coordinates time series analyses have been realized using Fourier or Harmonics spectral analyses, wavelets, least squares estimation among others. An approach is presented in this paper aiming to investigate the seasonal effects included in the stations coordinates time series. Experiments were carried out using data from stations Manaus (NAUS) and Fortaleza (BRFT) which belong to the Brazilian Continuous GPS Network (RBMC). The coordinates of these stations were estimated daily using PPP and were analyzed through wavelets for identification of the periods of the seasonal effects (annual and semi-annual) in each time series. These effects were removed by means of a filtering process applied in the series via the least squares adjustment (LSQ) of a periodic function. The results showed that the combination of these two mathematical tools, wavelets and LSQ, is an interesting and efficient technique for removal of seasonal effects in time series.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an approach for structural health monitoring (SHM) by using adaptive filters. The experimental signals from different structural conditions provided by piezoelectric actuators/sensors bonded in the test structure are modeled by a discrete-time recursive least square (RLS) filter. The biggest advantage to use a RLS filter is the clear possibility to perform an online SHM procedure since that the identification is also valid for non-stationary linear systems. An online damage-sensitive index feature is computed based on autoregressive (AR) portion of coefficients normalized by the square root of the sum of the square of them. The proposed method is then utilized in a laboratory test involving an aeronautical panel coupled with piezoelectric sensors/actuators (PZTs) in different positions. A hypothesis test employing the t-test is used to obtain the damage decision. The proposed algorithm was able to identify and localize the damages simulated in the structure. The results have shown the applicability and drawbacks the method and the paper concludes with suggestions to improve it. ©2010 Society for Experimental Mechanics Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces an indirect estimate for the coefficients of distribution, hydrodynamic dispersion and retardation for contaminants commonly encountered in sanitary landfills and their liners, such as Cu2+ and K+; this estimate is based on the relationship between concentration and certain physical characteristics of typical Brazilian soils. The results of previous studies investigating the migration of contaminants were used to develop mathematical expressions from multiple non-linear regressions. Using minimal squares regression, this transport was linked to various combinations of contaminant concentration and both structural and textural characteristics of the porous medium. Various combinations of characteristics and concentrations were investigated, with a mathematical expression obtained for each. The relationship between percentage of clay and the contaminant content proved to be the most closely correlated with actual transport parameters, with coefficients close to one.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to evaluate the influence of point measurements in images, with subpixel accuracy, and its contribution in the calibration of digital cameras. Also, the effect of subpixel measurements in 3D coordinates of check points in the object space will be evaluated. With this purpose, an algorithm that allows subpixel accuracy was implemented for semi-automatic determination of points of interest, based on Fõrstner operator. Experiments were accomplished with a block of images acquired with the multispectral camera DuncanTech MS3100-CIR. The influence of subpixel measurements in the adjustment by Least Square Method (LSM) was evaluated by the comparison of estimated standard deviation of parameters in both situations, with manual measurement (pixel accuracy) and with subpixel estimation. Additionally, the influence of subpixel measurements in the 3D reconstruction was also analyzed. Based on the obtained results, i.e., on the quantification of the standard deviation reduction in the Inner Orientation Parameters (IOP) and also in the relative error of the 3D reconstruction, it was shown that measurements with subpixel accuracy are relevant for some tasks in Photogrammetry, mainly for those in which the metric quality is of great relevance, as Camera Calibration.