993 resultados para optical behaviour


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structure and optical properties of thin films based on C60 materials are studied. Reproducible vacuum method of thin fullerene films production with Cd impurity on Si, glass and mica surfaces is developed. Surface morphology of the films are investigated by AFM and SEM methods. The ab initio quantum - chemical calculations of the geometry, total energy and excited energy states of complex fullerene- cadmium telluride supramolecules are performed. Photoluminescence spectra of composite thin films based on C60 before and after X-ray irradiation were measured. The intensity of additional peaks is defined as the charge composition due to the type of substrate. These results are interpreted as an appearance of the dipole-allowed transitions in the fullerene excited singlet states spectrum cause of an interference with cadmium telluride. X-ray irradiated films were investigated, and additional peaks in photoluminescence spectra were detected. These peaks appear as a result of molecular complexes formation from C60CdTe mixture and dimerization of the films. Density functional B3LYP quantum-chemical calculations for C60CdTe, molecular complexes, (C60)2 and C120O dimers were performed to elucidate some experimental results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical coherence tomography (OCT) is a promising medical imaging technique that uses light to capture real-time cross-sectional images from biological tissues in micrometer resolution. Commercially available optical coherence tomography systems are employed in diverse applications, including art conservation and diagnostic medicine, notably in cardiology and ophthalmology. Application of this technology in the brain may enable distinction between white matter and gray matter, and obtainment of detailed images from within the encephalon. We present, herein, the in vivo implementation of OCT imaging in the rat brain striatum. For this, two male 60-day-old rats (Rattus norvegicus, Albinus variation, Wistar) were stereotactically implanted with guide cannulas into the striatum to guide a 2.7-French diameter high-definition OCT imaging catheter (Dragonfly™, St. Jude Medical, USA). Obtained images were compared with corresponding histologically stained sections to collect imaging samples. A brief analysis of OCT technology and its current applications is also reported, as well as intra-cerebral OCT feasibility on brain mapping during neurosurgical procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

At present, one of the main concerns of green network is to minimize the power consumption of network infrastructure. Surveys show that, the highest amount of power is consumed by the network devices during its runtime. However to control this power consumption it is important to know which factors has highest impact on this matter. This paper is focused on the measurement and modeling the power consumption of an Ethernet switch during its runtime considering various types of input parameters with all possible combinations. For the experiment, three input parameters are chosen. They are bandwidth, link load and number of connections. The output to be measured is the power consumption of the Ethernet switch. Due to the uncertain power consuming pattern of the Ethernet switch a fully-comprehensive experimental evaluation would require an unfeasible and cumbersome experimental phase. Because of that, design of experiment (DoE) method has been applied to obtain adequate information on the effects of each input parameters on the power consumption. The whole work consists of three parts. In the first part a test bed is planned with input parameters and the power consumption of the switch is measured. The second part is about generating a mathematical model with the help of design of experiment tools. This model can be used for measuring precise power consumption in different scenario and also pinpoint the parameters with higher influence in power consumption. And in the last part, the mathematical model is evaluated by comparing with the experimental values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Upconversion photoluminescence is a unique property of mostly certain inorganic materials, which are capable of converting low-energy infrared radiation into a higher-energy emission at visible wavelengths. This anti-Stokes shift enables luminescence detection without autofluorescence, which makes the upconverting materials a highly suitable reporter technology for optical biosensing applications. Furthermore, they exhibit long luminescence lifetime with narrow bandwidths also at the optical window of biomaterials enabling luminescence measurements in challenging sample matrices, such as whole blood. The aim of this thesis was to study the unique properties and the applicability of nano-sized upconverting phosphors (UCNPs) as reporters in biosensing applications. To render the inorganic nanophosphors water-dispersible and biocompatible, they were subjected to a series of surface modifications starting with silica-encapsulation and ending with a bioconjugation step with an analyte-recognizing biomolecule. The paramagnetism of the lanthanide dopants in the nanophosphors was exploited to develop a highly selective separation method for the UCNP-bioconjugates based on the magnetic selectivity of the high gradient magnetic separation (HGMS) system. The applicability of the nano-sized UCNPs as reporters in challenging sample matrices was demonstrated in two homogeneous sensing applications based on upconversion resonance energy transfer (UC-RET). A chemosensor for intracellular pH was developed exploiting UC-RET between the UCNP and a fluorogenic pH-sensitive dye with strongly increasing fluorescence intensity in decreasing pH. The pH-independent emission of the UCNPs at 550 nm was used for referencing. The applicability of the pH-nanosensor for intracellular pH measurement was tested in HeLa cells, and the acidic pH of endosomes could be detected with a confocal fluorescence microscope. Furthermore, a competitive UC-RET-based assay for red blood cell folic acid was developed for the measurement of folate directly from a whole blood sample. The optically transparent window of biomaterials was used in both the excitation and the measurement of the UC-RET sensitized emission of a near-infrared acceptor dye to minimize sample absorption, and the anti-Stokes detection completely eliminated the Stokes-shifted autofluorescence. The upconversion photoluminescence efficiency is known to be dependent on crystallite size, because the increasing surface-to-volume ratio of nano-sized UCNPs renders them more susceptible to quenching effects of the environment than their bulk counterpart. Water is known to efficiently quench the luminescence of lanthanide dopants. In this thesis, the quenching mechanism of water was studied using luminescence decay measurements. Water was found to quench the luminescence of UCNPs by increasing the non-radiative relaxation of the excited state of Yb3+ sensitizer ion, which had a very strong quenching effect on upconversion luminescence intensity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Weldability of powder bed fusion (PBF) fabricated components has come to discussion in past two years due to resent developments in the PBF technology and limited size of the machines used in the fabrication process. This study concentrated on effects of energy input of welding on mechanical properties and microstructural features of welds between PBF fabricated stainless steel 316L sheets and cold rolled sheet metal of same composition by the means of destructive testing and microscopic analysis. Optical fiber diameter, laser power and welding speed were varied during the experiments that were executed following one variable at a time (OVAT) method. One of the problems of welded PBF fabricated components has been lower elongations at break comparing to conventionally manufactured components. Decreasing energy input of the laser keyhole welding decreased elongations at break of the welded specimens. Ultimate tensile strengths were not affected significantly by the energy input of the welding, but fracturing of the specimens welded using high energy input occurred from the weld metal. Fracturing of the lower energy input welds occurred from the PBF fabricated base metal. Energy input was found to be critical factor for mechanical properties of the welds. Multioriented grain growth and formation of neck at fusion zone boundary on the cold rolled side of the weld was detected and suspected to be result from weld pool flows caused by differences in molten weld pool behaviour between the PBF fabricated and cold rolled sides of the welds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän tutkielman aiheena on ammattikääntäjien tiedonhaku, kun käytettävissä on ainoastaan verkkolähteitä. Tutkimuksessa on tarkasteltu, mistä ja miten ammattikääntäjät etsivät tietoa internetistä kääntäessään lähtötekstiä englannista suomeen. Lisäksi tutkimuksen tarkoituksena on osoittaa, että tiedonhakutaidot ja lähdekriittisyys ovat käännöskompetensseja, joita tulisi sekä ylläpitää että opettaa osana kääntäjäkoulutusta. Tutkimuksen aineisto kerättiin empiirisesti käyttämällä kolmea metodia. Käännösprosessi ja sen aikana tapahtunut tiedonhaku tallennettiin käyttäen Camtasia-näyttövideointiohjelmaa ja Translog-II -näppäilyntallennusohjelmaa. Lisäksi tutkimukseen osallistuneet kääntäjät täyttivät kaksi kyselyä, joista ensimmäinen sisälsi taustatietokysymyksiä ja toinen itse prosessiin liittyviä retrospektiivisiä kysymyksiä. Kyselyt toteutettiin Webropol-kyselytyökalulla. Aineistoa kerättiin yhteensä viidestä koetilanteesta. Tutkimuksessa tarkasteltiin lähemmin kolmen ammattikääntäjän tiedon-hakutoimintoja erottelemalla käännösprosesseista ne tauot, joiden aikana kääntäjät etsivät tietoa internetistä. Käytettyjen verkkolähteiden osalta tutkimuksessa saatiin vastaavia tuloksia kuin aiemmissakin tutkimuksissa: eniten käytettyjä olivat Google, Wikipedia sekä erilaiset verkkosanakirjat. Tässä tutkimuksessa kuitenkin paljastui, että ammattikääntäjien tiedonhaun toimintamallit vaihtelevat riippuen niin kääntäjän erikoisalasta kuin hänen tiedonhakutaitojensa tasosta. Joutuessaan työskentelemään tutun työympäristönsä ja oman erikoisalansa ulkopuolella turvautuu myös osa ammattikääntäjistä alkeellisimpiin tiedonhakutekniikoihin, joita käännöstieteen opiskelijoiden on havaittu yleisesti käyttävän. Tulokset paljastivat myös, että tiedonhaku voi viedä jopa 70 prosenttia koko käännösprosessiin kuluvasta ajasta riippuen kääntäjän aiemmasta lähtötekstin aihepiiriin liittyvästä tietopohjasta ja tiedonhaun tehokkuudesta. Tutkimuksessa saatujen tulosten pohjalta voidaan sanoa, että myös ammattikääntäjien tulisi kehittää tiedonhakutaitojaan pitääkseen käännösprosessinsa tehokkaana. Lisäksi kääntäjien pitäisi muistaa arvioida kriittisesti käyttämiään tietolähteitä: lähdekritiikki on tarpeen erityisesti verkkolähteitä käytettäessä. Tästä syystä tiedonhakutaitoja ja lähdekriittisyyttä tulisikin opettaa ja harjoitella jo osana kääntäjäkoulutusta. Kääntäjien ei myöskään pidä jättää tiedonhakua pelkkien verkkolähteiden varaan, vaan jatkossakin käyttää hyväkseen niin painettuja tietolähteitä kuin myös henkilölähteitä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum computation and quantum communication are two of the most promising future applications of quantum mechanics. Since the information carriers used in both of them are essentially open quantum systems it is necessary to understand both quantum information theory and the theory of open quantum systems in order to investigate realistic implementations of such quantum technologies. In this thesis we consider the theory of open quantum systems from a quantum information theory perspective. The thesis is divided into two parts: review of the literature and original research. In the review of literature we present some important definitions and known results of open quantum systems and quantum information theory. We present the definitions of trace distance, two channel capacities and superdense coding capacity and give a reasoning why they can be used to represent the transmission efficiency of a communication channel. We also show derivations of some properties useful to link completely positive and trace preserving maps to trace distance and channel capacities. With the help of these properties we construct three measures of non-Markovianity and explain why they detect non-Markovianity. In the original research part of the thesis we study the non-Markovian dynamics in an experimentally realized quantum optical set-up. For general one-qubit dephasing channels we calculate the explicit forms of the two channel capacities and the superdense coding capacity. For the general two-qubit dephasing channel with uncorrelated local noises we calculate the explicit forms of the quantum capacity and the mutual information of a four-letter encoding. By using the dynamics in the experimental implementation as a set of specific dephasing channels we also calculate and compare the measures in one- and two-qubit dephasing channels and study the options of manipulating the environment to achieve revivals and higher transmission rates in superdense coding protocol with dephasing noise. Kvanttilaskenta ja kvanttikommunikaatio ovat kaksi puhutuimmista tulevaisuuden kvanttimekaniikan käytännön sovelluksista. Koska molemmissa näistä informaatio koodataan systeemeihin, jotka ovat oleellisesti avoimia kvanttisysteemejä, sekä kvantti-informaatioteorian, että avointen kvanttisysteemien tuntemus on välttämätöntä. Tässä tutkielmassa käsittelemme avointen kvanttisysteemien teoriaa kvantti-informaatioteorian näkökulmasta. Tutkielma on jaettu kahteen osioon: kirjallisuuskatsaukseen ja omaan tutkimukseen. Kirjallisuuskatsauksessa esitämme joitakin avointen kvanttisysteemien ja kvantti-informaatioteorian tärkeitä määritelmiä ja tunnettuja tuloksia. Esitämme jälkietäisyyden, kahden kanavakapasiteetin ja superdense coding -kapasiteetin määritelmät ja esitämme perustelun sille, miksi niitä voidaan käyttää kuvaamaan kommunikointikanavan lähetystehokkuutta. Näytämme myös todistukset kahdelle ominaisuudelle, jotka liittävät täyspositiiviset ja jäljensäilyttävät kuvaukset jälkietäisyyteen ja kanavakapasiteetteihin. Näiden ominaisuuksien avulla konstruoimme kolme epä-Markovisuusmittaa ja perustelemme, miksi ne havaitsevat dynamiikan epä-Markovisuutta. Oman tutkimuksen osiossa tutkimme epä-Markovista dynamiikkaa kokeellisesti toteutetussa kvanttioptisessa mittausjärjestelyssä. Yleisen yhden qubitin dephasing-kanavan tapauksessa laskemme molempien kanavakapasiteettien ja superdense coding -kapasiteetin eksplisiittiset muodot. Yleisen kahden qubitin korreloimattomien ympäristöjen dephasing-kanavan tapauksessa laskemme yhteisen informaation lausekkeen nelikirjaimisessa koodauksessa ja kvanttikanavakapasiteetin. Käyttämällä kokeellisen mittajärjestelyn dynamiikkoja esimerkki dephasing-kanavina me myös laskemme konstruoitujen epä-Markovisuusmittojen arvot ja vertailemme niitä yksi- ja kaksi-qubitti-dephasing-kanavissa. Lisäksi käyttäen kokeellisia esimerkkikanavia tutkimme, kuinka ympäristöä manipuloimalla superdense coding –skeemassa voidaan saada yhteinen informaatio ajoittain kasvamaan tai saavuttaa kaikenkaikkiaan korkeampi lähetystehokkuus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical coherence tomography (OCT) is a novel intracoronary imaging application for the assessment of native lesions and coronary stents. The purpose of this thesis was to evaluate the safety and feasibility of frequency-domain OCT (FD-OCT) based on experiences of the Satakunta Central Hospital (I). Early vascular healing was evaluated after implantation of endothelial progenitor cell capturing (II) and bio-active titanium-nitride-oxide coated stents (III) in two studies, each with 20 patients. Vascular healing was also compared after implantation of bio-active and everolimus-eluting stents on 28 patients after 9-month follow-up (IV). Long-term vascular healing of bio-active and paclitaxel-eluting stents was assessed in the last study with 18 patients (V). The results indicate that FD-OCT is safe and feasible (I). Both bio-active and endothelial progenitor cell capturing stents showed near-complete endothelialisation after one-month follow-up, which is desirable when prolonged dual anti-platelet therapy needs to be avoided after stenting (II and III). Endothelialisation of bio-active stents showed a predictable pattern at mid-term and long-term follow up (IV and V). Endothelialisation of everolimus-eluting stents was not complete at 9 months follow-up, which may suggest that interruption of dual antiplatelet therapy at this time point may not be safe (IV). Finally, delayed vascular healing may be present in patients treated with paclitaxel-eluting stents as long as 4 years from implantation, which reinforces the previously raised concerns on the long-term safety of this device (V).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Full contour monolithic zirconia restorations have shown an increased popularity in the dental field over the recent years, owing to its mechanical and acceptable optical properties. However, many features of the restoration are yet to be researched and supported by clinical studies to confirm its place among the other indirect restorative materials This series of in vitro studies aimed at evaluating and comparing the optical and mechanical properties, light cure irradiance, and cement polymerization of multiple monolithic zirconia material at variable thicknesses, environments, treatments, and stabilization. Five different monolithic zirconia materials, four of which were partially stabilized and one fully stabilized were investigated. The optical properties in terms of surface gloss, translucency parameter, and contrast ratio were determined via a reflection spectrophotometer at variable thicknesses, coloring, sintering method, and after immersion in an acidic environment. Light cure irradiance and radiant exposure were quantified through the specimens at variable thicknesses and the degree of conversion of two dual-cure cements was determined via Fourier Transform Infrared spectroscopy. Bi-axial flexural strength was evaluated to compare between the partially and fully stabilized zirconia prepared using different coloring and sintering methods. Surface characterization was performed using a scanning electron microscope and a spinning disk confocal microscope. The surface gloss and translucency of the zirconia investigated were brand and thickness dependent with the translucency values decreasing as the thickness increased. Staining decreased the translucency of the zirconia and enhanced surface gloss as well as the flexural strength of the fully stabilized zirconia but had no effect on partially stabilized zirconia. Immersion in a corrosive acid increased surface gloss and decreased the translucency of some zirconia brands. Zirconia thickness was inversely related to the amount of light irradiance, radiant exposure, and degree of monomer conversion. Type of sintering furnace had no effect on the optical and mechanical properties of zirconia. Monolithic zirconia maybe classified as a semi-translucent material that is well influenced by the thickness, limiting its use in the esthetic zones. Conventional acid-base reaction, autopolymerizing and dual-cure cements are recommended for its cementation. Its desirable mechanical properties give it a high potential as a restoration for posterior teeth. However, close monitoring with controlled clinical studies must be determined before any definite clinical recommendations can be drawn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis was to examine how aquatic organisms, such as fish, behave in an altered environmental condition. Many species of fish use vision as their primary tool to gain information about their surrounding environment. The visual conditions of aquatic habitats are often altered as a result of anthropogenic disturbance, such as eutrophication that initiates algal turbidity. In general, turbidity reduces the visibility and can be hypothesized to have an influence on the behaviour of fish. I used the three-spined stickleback (Gasterosteus aculeatus) as a model species and conducted four studies in the laboratory to test how algal turbidity affects its behaviour. In this thesis, two major behavioural aspects are discussed. The first is antipredator behaviour. In study I, the combined effects of turbidity and shoot density on habitat choice (shelter vs open) behaviour was tested on a group of sticklebacks (20 fish) in the presence and absence of piscivorous perch (Perca fluviatilis). In study II, I examined the behavioural responses of feeding sticklebacks when they were exposed to the sudden appearance of an avian predator (the silhouette of a common tern, Sterna hirundo). The study was done in turbid and clear water using three different groups sizes (1, 3 and 6 fish). The second aspect is foraging behaviour. Study III & IV focused on the effects of algal turbidity on the foraging performance of sticklebacks. In study III, I conducted two separate experiments to examine the effects of turbidity on prey consumption and prey choice of sticklebacks. In this experiment turbidity levels and the proportion of large and small prey (Daphnia spp.) were manipulated. In study IV, I studied whether a group of six sticklebacks can distribute themselves according to food input at two feeding stations in a way that provided each fish with the same amount of food in clear and turbid water. I also observed whether the fish can follow changes in resource distribution between the foraging patches. My results indicate an overall influence of algal turbidity on the antipredator and foraging behaviour of sticklebacks. In the presence of a potential predator, the use of the sheltered habitat was more pronounced at higher turbidity. Besides this, sticklebacks reduced their activity levels with predator presence at higher turbidity and shoot density levels, suggesting a possible antipredator adaptation to avoid a predator. When exposed to a sudden appearance of an avian predator, sticklebacks showed a weaker antipredator response in turbid water, which suggests that turbidity degrades the risk assessment capabilities of sticklebacks. I found an effect of group size but not turbidity in the proportion of sticklebacks that fled to the shelter area, which indicates that sticklebacks are able to communicate among group members at the experimental turbidity levels. I found an overall negative effect of turbidity on food intake. Both turbidity and changes in the proportion of prey sizes played a significant role in a stickleback’s prey selection. At lower turbidity levels (clear <1 and 5 NTU) sticklebacks showed preferences for large prey, whereas in more turbid conditions and when the proportion of large to small prey increased sticklebacks became increasingly random in their prey selection. Finally, my results showed that groups of sticklebacks disperse themselves between feeding stations according to the reward ratios following the predictions of the ideal free distribution theory. However, they took a significantly longer time to reach the equilibrium distribution in turbid water than in clear water. In addition, they showed a slower response to changes in resource distribution in a turbid environment. These findings suggest that turbidity interferes with the information transfer among group foragers. It is important to understand that aquatic animals are often exposed to a degraded environment. The findings of this thesis suggest that algal turbidity negatively affects their behavioural performance. The results also shed light on the underlying behavioural strategies of sticklebacks in turbid conditions that might help them adapt to an altered environmental situation and increase their survival. In conclusion, I hold that although algal turbidity has detrimental effects on the antipredator and foraging behaviour of sticklebacks, their behavioural adjustment might help them adapt to a changing environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PhotoAcoustic Imaging (PAI) is a branch in clinical and pre-clinical imaging, that refers to the techniques mapping acoustic signals caused by the absorption of the short laser pulse. This conversion of electromagnetic energy of the light to the mechanical (acoustic) energy is usually called photoacoustic effect. PAI, by combining optical excitation with acoustical detection, is able to preserve the diffraction limited spatial resolution. At the same time, the penetration depth is extended beyond the diffusive limit. The Laser-Scanning PhotoAcoustic Microscope system (LS-PAM) has been developed, that offers the axial resolution of 7.75 µm with the lateral resolution better than 10 µm. The first in vivo imaging experiments were carried out. Thus, in vivo label-free imaging of the mouse ear was performed. The principle possibility to image vessels located in deep layers of the mouse skin was shown. As well as that, a gold printing sample, vasculature of the Chick Chorioallantoic Membrane Assay, Drosophila larvae were imaged by PAI. During the experimental work, a totally new application of PAM was found, in which the acoustic waves, generated by incident light can be used for further imaging of another sample. In order to enhance the performance of the presented system two main recommendation can be offered. First, the current system should be transformed into reflection-mode setup system. Second, a more powerful source of light with the sufficient repetition rate should be introduced into the system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis, bacteriorhodopsin (BR) photosensor’s optical and electrical properties were studied. The BR sensor consisted of a dry film with BR in polyvinyl alcohol and covered with transparent conductors. In the experiments the BR photocycle was started with two lasers. The characteristics of the BR sensor were measured in two ways. The first approach was theoretical and it required knowing the laser parameters. The second way required assembling a measurement setup for the optical response measurements. However, no measurable results were obtained due to low laser power. The photoelectric response was measured in the experiments with two laser systems and the amplifier was tested. In the experiment with a Cavitar laser, the photoelectric response was obtained. In the experiment with FemtoFiber Pro laser, the photoelectric response was not measured. The expected amplitude of the response was obtained. The experimental data was analyzed and possible solutions for reducing the interference were given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Physical inactivity and positive energy balance pose a risk to health. They increase the risk of obesity and associated non-communicable diseases. Recently, also sedentary behaviour has been associated with obesity and non-communicable diseases. Nevertheless, it has been unclear which type of sedentary behaviour is the most harmful. It is also unknown whether the relationship of sedentary behaviour with obesity is truly independent of other factors, for example physical activity and diet. Longitudinal data are limited, and the direction of causality and the mechanism of action are still unknown. Aims: The aim of this study was 1) to identify the type of sedentary behaviour having the strongest association with obesity, 2) to explore the causal relationship of sedentary behaviour and weight increase, and 3) to additionally, investigate the relationship of sedentary behaviour with fatty liver. These were studied in cross-sectional and/or longitudinal settings using data from the Cardiovascular Risk in Young Finns Study. Special emphasis was put on the evaluation of a wide range of other lifestyle factors and risks for obesity and fatty liver. Subjects: 2,060 subjects (aged 33-50 years in 2011, of which 55 % were female) from the Cardiovascular Risk in Young Finns Study participating in follow-ups in 2001, 2007, and 2011. Measures: Self-reported time spent in various types of sedentary behaviour (I), or TV viewing time (I-III). Measured body weight, height and waist circumference (I-III), and genetic variants for high BMI (I). Fasting plasma concentrations of gamma-glutamyltransferase enzyme and triglyceride, calculated Fatty Liver Index (based on gamma-glutamyltransferase and triglyceride concentration, BMI and waist circumference), and the amount of intrahepatic fat measured with ultrasound (III). Self-reported leisure-time physical activity and active commuting, occupational physical activity, energy intake, diet, alcohol consumption, smoking, socioeconomic status, and sleep duration as possible confounders were considered (I-III). Results: TV viewing is the sedentary behaviour type that has the strongest association with obesity. Sedentary behaviour (TV viewing) precedes weight increase, and not the other way around. Sedentary behaviour (TV viewing) is associated with increased risk of fatty liver. Conclusions: Sedentary behaviour (especially high TV viewing time) is associated with increased risks of obesity and fatty liver. Intervention studies are needed to assess whether reduction of TV time would prevent obesity and fatty liver.