873 resultados para modelo linear com resposta em platô


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enantioselective syntheses of diquinane and cis, anti, cis-linear triquinanes, starting from the readily available (S)-campholenaldehyde, employing an intramolecular rhodium carbenoid CH insertion reaction, are described. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied the dynamics of excitation transfer between two conjugated polyene molecules whose intermolecular separation is comparable to the molecular dimensions. We have employed a correlated electron model that includes both the charge-charge, charge-bond, and bond-bond intermolecular electron repulsion integrals. We have shown that the excitation transfer rate varies as inverse square of donor-acceptor separation R-2 rather than as R-6, suggested by the Foumlrster type of dipolar approximation. Our time-evolution study alsom shows that the orientational dependence on excitation transfer at a fixed short donor-acceptor separation cannot be explained by Foumlrster type of dipolar approximation beyond a certain orientational angle of rotation of an acceptor polyene with respect to the donor polyene. The actual excitation transfer rate beyond a certain orientational angle is faster than the Foumlrster type of dipolar approximation rate. We have also studied the excitation transfer process in a pair of push-pull polyenes for different push-pull strengths. We have seen that, depending on the push-pull strength, excitation transfer could occur to other dipole coupled states. Our study also allows for the excitation energy transfer to optically dark states which are excluded by Foumlrster theory since the one-photon transition intensity to these states (from the ground state) is zero.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a modified design method for linear transconductor circuit in 130 nm CMOS technology to improve linearity, robustness against process induced threshold voltage variability and reduce harmonic distortion. Source follower in the adaptively biased differential pair (ABDP) linear transconductor circuit is replaced with flipped voltage follower to improve the efficiency of the tail current source, which is connected to a conventional differential pair. The simulation results show the performance of the modified circuit also has better speed, noise performance and common mode rejection ratio compared to the ABDP circuit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural determinants of the binding affinity of linear dicationic molecules toward lipid A have been examined with respect to the distance between the terminal cationic functions, the basicity, and the type of cationic moieties using a series of spermidine derivatives and pentamidine analogs by fluorescence spectroscopic methods, The presence of two terminal cationic groups corresponds to enhanced affinity, A distinct sigmoidal relationship between the intercationic distance and affinity was observed with a sharp increase at 11 Angstrom, levelling off at about 13 Angstrom. The basicity (pK) and nature of the cationic functions are poor correlates of binding potency, since molecules bearing primary amino, imidazolino, or guanido termini are equipotent, The interaction of pentamidine, a bisamidine drug, with lipid A, characterized in considerable detail employing the putative intermolecular excimerization of the drug, suggests a stoichiometry of 1:1 in the resultant complex, The binding is driven almost exclusively by electrostatic forces, and is dependent on the ionization states of both lipid A and the drug, Under conditions when lipid A is highly disaggregated, pentamidine binds specifically to bis-phosphoryl- but not to monophosphoryl-lipid A indicating that both phosphate groups of lipid A are necessary for electrostatic interactions by the terminal amidininium groups of the drug, Based on these data, a structural model is proposed for the pentamidine-lipid A complex, which may be of value in designing endotoxin antagonists from first principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we consider the design and bit-error performance analysis of linear parallel interference cancellers (LPIC) for multicarrier (MC) direct-sequence code division multiple access (DS-CDMA) systems. We propose an LPIC scheme where we estimate and cancel the multiple access interference (MAT) based on the soft decision outputs on individual subcarriers, and the interference cancelled outputs on different subcarriers are combined to form the final decision statistic. We scale the MAI estimate on individual subcarriers by a weight before cancellation. In order to choose these weights optimally, we derive exact closed-form expressions for the bit-error rate (BER) at the output of different stages of the LPIC, which we minimize to obtain the optimum weights for the different stages. In addition, using an alternate approach involving the characteristic function of the decision variable, we derive BER expressions for the weighted LPIC scheme, matched filter (MF) detector, decorrelating detector, and minimum mean square error (MMSE) detector for the considered multicarrier DS-CDMA system. We show that the proposed BER-optimized weighted LPIC scheme performs better than the MF detector and the conventional LPIC scheme (where the weights are taken to be unity), and close to the decorrelating and MMSE detectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility of applying two approximate methods for determining the salient features of response of undamped non-linear spring mass systems subjected to a step input, is examined. The results obtained on the basis of these approximate methods are compared with the exact results that are available for some particular types of spring characteristics. The extension of the approximate methods for non-linear systems with general polynomial restoring force characteristics is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An exact expression for the frequency of a non-linear cubic spring mass system is obtained considering the effect of static deflection. An alternative expression for the approximate frequency is also obtained by the direct linearization procedure; it is shown that this is very accurate as compared with the exact method. This approximate frequency equation is used to explain a “dual behaviour” of the frequency amplitude curves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transient response spectrum of a cubic spring mass system subjected to a step function input is obtained. An approximate method is adopted where non-linear restoring force characteristic is replaced by two linear segments, so that the mean square error between them is a minimum. The effect of viscous damping on the peak response is also discussed for various values of the damping constant and the non-linearity restoring force parameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equations proposed in previous work on the non-linear motion of a string show a basic disagreement, which is here traced to an assumption about the longitudinal displacement u. It is shown that it is neither necessary nor justifiable to assume that u is zero; and also that the velocity of propagation of u disturbances in a string is different from that in an infinite medium, although this difference is usually negligible. After formulating the exact equations of motion for the string, a systematic procedure is described for obtaining approximations to these equations to any order, making only the assumption that the strain in the material of the string is small. The lowest order equations in this scheme are non-linear, and are used to describe the response of a string near resonance. Finally, it is shown that in the absence of damping, planar motion of a string is always unstable at sufficiently high amplitudes, the critical amplitude falling to zero at the natural frequency and its subharmonics. The effect of slight damping on this instability is also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a new approach to the study of non-linear, non-autonomous systems is presented. The method outlined is based on the idea of solving the governing differential equations of order n by a process of successive reduction of their order. This is achieved by the use of “differential transformation functions”. The value of the technique presented in the study of problems arising in the field of non-linear mechanics and the like, is illustrated by means of suitable examples drawn from different fields such as vibrations, rigid body dynamics, etc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a method of arriving at transformations which convert a class of non-linear systems into equivalent linear systems, has been presented along with suitable examples, which illustrate its application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free-fall terminal velocities of single spheres and of single-row assemblies containing up to six spheres, with line of centres of spheres perpendicular to the direction of motion, have been determined in the particle Reynolds numbers range 0.2-4, and interaction effects obtained in the case of assemblies relative to drag on single isolated spheres, are discussed. The observed decrease in the drag on a sphere of an assembly is explained on the basis of theoretical considerations governing flow phenomena in such systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A miniature furnace suitable for routine collection of x-ray data up to 1000°C from single crystals on the Hilger and Watts linear diffractometer, without restricting the normally allowed region of reciprocal space on the diffractometer, is described. The crystal is heated primarily by radiation from a surrounding current-heated, stationary platinum coil wound on a silica bracket. The coil is split at its middle to provide a 4 mm gap for crystal mounting and x-irradiation. The crystal, mounted on a standard goniometer head, can be rotated and centred freely, as in the room temperature case. There is no need for any radiation shields or water-cooling arrangement. Investigations up to 1500°C are possible with slight modifications of the furnace.