995 resultados para magnetic powder


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The preparation and characterization of coordination complexes of Schiff-base and crown ether macrocycles is presented, for application as contrast agents for magnetic resonance imaging, Project 1; and single-molecule magnets (SMMs), Projects 2 and 3. In Project 1, a family of eight Mn(II) and Gd(III) complexes of N3X2 (X = NH, O) and N3O3 Schiff-base macrocycles were synthesized, characterized, and evaluated as potential contrast agents for MRI. In vitro and in vivo (rodent) studies indicate that the studied complexes display efficient contrast behaviour, negligible toxicity, and rapid excretion. In Project 2, DyIII complexes of Schiff-base macrocycles were prepared with a view to developing a new family of mononuclear Ln-SMMs with pseudo-D5h geometries. Each complex displayed slow relaxation of magnetization, with magnetically-derived energy barriers in the range Ueff = 4 – 24 K. In Project 3, coordination complexes of selected later lanthanides with various crown ether ligands were synthesized. Two families of complexes were structurally and magnetically analyzed: ‘axial’ or sandwich-type complexes based on 12-crown-4 and 15-crown-5; and ‘equatorial’ complexes based on 18-crown-6. Magnetic data are supported by ab initio calculations and luminescence measurements. Significantly, the first mononuclear Ln-SMM prepared from a crown ether ligand is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our work on single molecule magnets and multifunctional magnetic materials is presented in four projects. In the first project we show for first time that heteroatomic-type pseudohalides, such as OCN-, can be employed as structure-directing ligands and ferromagnetic couplers in higher oxidation state metal cluster chemistry. The initial use of cyanato groups in Mn cluster chemistry has afforded structurally interesting MnII/III14 (1) and MnII/III/IV16 (2) clusters in which the end-on bridging cyanates show a preference in binding through their O-atom. The Mn14 compound shows entirely visible out-of-phase alternating currect signals below 5 K and large hysteresis loops below 2 K. Furthermore, the amalgamation of azido groups with the triethanolamine tripodal ligand in manganese carboxylate cluster chemistry has led to the isolation of a new ferromagnetic, high-nuclearity and mixed-valence MnII/III15Na2 (3) cluster with a large ground-state spin value of S = 14. In the second project we demonstrate a new synthetic route to purely inorganic-bridged, transition metal-azido clusters [CoII7 (4) and NiII7 (5)] and coordination polymers [{FeII/III2}n (6)] which exhibit strong ferromagnetic, SMM and long-range magnetic ordering behaviors. We also show that access to such a unique ferromagnetic class of inorganic, N-rich and O-free materials is feasible through the use of Me3SiN3 as the azido-ligand precursor without requiring the addition of any organic chelating/bridging ligand. In the last projects we have tried to bring together molecular magnetism and optics via the synthesis of multifunctional magnetic materials based on 3d- or 4f-metal ions. We decided to approach such challenge from two different directions: firstly, in our third project, by the deliberate replacement of non-emissive carboxylato ligands in known 3d-SMMs with their fluorescent analogues, without perturbing the metal-core structure and SMM properties (complexes 7, 8, and 9). The second route (last project) involves the use of naphthalene or pyridine-based polyalcohol bridging ligands for the synthesis of new polynuclear LnIII metal clusters (Ln = lanthanide) with novel topologies, SMM behaviors and luminescent properties arising from the increased efficiency of the “antenna” organic group. This approach has led us to the isolation of two new families of LnIII8 (complexes 10-13) and LnIII4 (complexes 14-20) clusters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of magnetic dilution and applied pressure on frustrated spinels GeNi2O4, GeCo2O4, and NiAl2O4 are reported. Dilution was achieved by substitution of Mg2+ in place of magnetically active Co2+ and Ni2+ ions. Large values of the percolation thresholds were found in GeNi(2-x)MgxO4. Specifically, pc1 = 0.74 and pc2 = 0.65 in the sub-networks associated with the triangular and kagome planes, respectively. This anomalous behaviour may be explained by the kagome and triangular planes behaving as coupled networks, also know as a network of networks. In simulations of coupled lattices that form a network of networks, similar anomalous percolation threshold values have been found. In addition, at dilution levels above x=0.30, there is a T^2 dependency in the magnetic heat capacity which may indicate two dimensional spin glass behaviour. Applied pressures in the range of 0 GPa to 1.2 GPa yield a slight decrease in ordering temperature for both the kagome and triangular planes. In GeCo(2-x)MgxO4, the long range magnetic order is more robust with a percolation threshold of pc=0.448. Similar to diluted nickel germanate, at low temperatures, a T^2 magnetic heat capacity contribution is present which indicates a shift from a 3D ordered state to a 2D spin glass state in the presence of increased dilution. Dynamic magnetic susceptibility data indicate a change from canonical spin glass to a cluster glass behaviour. In addition, there is a non-linear increase in ordering temperature with applied pressure in the range P = 0 to 1.0 GPa. A spin glass ground state was observed in Ni(1-x)MgxAl2O4 for (x=0 to 0.375). Analysis of dynamic magnetic susceptibility data yield a characteristic time of tau* = 1.0x10^(-13) s, which is indicative of canonical spin glass behaviour. This is further corroborated by the linear behaviour of the magnetic specific heat contribution. However, the increasing frequency dependence of the freezing temperature suggests a trend towards spin cluster glass formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Affiliation: Département de Psychologie, Université de Montréal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les lésions de la moelle épinière ont un impact significatif sur la qualité de la vie car elles peuvent induire des déficits moteurs (paralysie) et sensoriels. Ces déficits évoluent dans le temps à mesure que le système nerveux central se réorganise, en impliquant des mécanismes physiologiques et neurochimiques encore mal connus. L'ampleur de ces déficits ainsi que le processus de réhabilitation dépendent fortement des voies anatomiques qui ont été altérées dans la moelle épinière. Il est donc crucial de pouvoir attester l'intégrité de la matière blanche après une lésion spinale et évaluer quantitativement l'état fonctionnel des neurones spinaux. Un grand intérêt de l'imagerie par résonance magnétique (IRM) est qu'elle permet d'imager de façon non invasive les propriétés fonctionnelles et anatomiques du système nerveux central. Le premier objectif de ce projet de thèse a été de développer l'IRM de diffusion afin d'évaluer l'intégrité des axones de la matière blanche après une lésion médullaire. Le deuxième objectif a été d'évaluer dans quelle mesure l'IRM fonctionnelle permet de mesurer l'activité des neurones de la moelle épinière. Bien que largement appliquées au cerveau, l'IRM de diffusion et l'IRM fonctionnelle de la moelle épinière sont plus problématiques. Les difficultés associées à l'IRM de la moelle épinière relèvent de sa fine géométrie (environ 1 cm de diamètre chez l'humain), de la présence de mouvements d'origine physiologique (cardiaques et respiratoires) et de la présence d'artefacts de susceptibilité magnétique induits par les inhomogénéités de champ, notamment au niveau des disques intervertébraux et des poumons. L'objectif principal de cette thèse a donc été de développer des méthodes permettant de contourner ces difficultés. Ce développement a notamment reposé sur l'optimisation des paramètres d'acquisition d'images anatomiques, d'images pondérées en diffusion et de données fonctionnelles chez le chat et chez l'humain sur un IRM à 3 Tesla. En outre, diverses stratégies ont été étudiées afin de corriger les distorsions d'images induites par les artefacts de susceptibilité magnétique, et une étude a été menée sur la sensibilité et la spécificité de l'IRM fonctionnelle de la moelle épinière. Les résultats de ces études démontrent la faisabilité d'acquérir des images pondérées en diffusion de haute qualité, et d'évaluer l'intégrité de voies spinales spécifiques après lésion complète et partielle. De plus, l'activité des neurones spinaux a pu être détectée par IRM fonctionnelle chez des chats anesthésiés. Bien qu'encourageants, ces résultats mettent en lumière la nécessité de développer davantage ces nouvelles techniques. L'existence d'un outil de neuroimagerie fiable et robuste, capable de confirmer les paramètres cliniques, permettrait d'améliorer le diagnostic et le pronostic chez les patients atteints de lésions médullaires. Un des enjeux majeurs serait de suivre et de valider l'effet de diverses stratégies thérapeutiques. De telles outils représentent un espoir immense pour nombre de personnes souffrant de traumatismes et de maladies neurodégénératives telles que les lésions de la moelle épinière, les tumeurs spinales, la sclérose en plaques et la sclérose latérale amyotrophique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans la première partie, nous présentons les résultats de l'étude du supraconducteur sans inversion de symétrie LaRhSi3 par spectroscopie muonique. En champ nul, nous n'avons pas détecté de champ interne. Ceci indique que la fonction d'onde de l'état supraconducteur n'est pas dominée par l'état triplet. Les mesures en champ transverse de 35G présentent une transition en accord avec la transition de phase attendue sous le champ critique Hc1. Nous avons répété ces mesures pour un champ entre Hc1 et Hc2, 150G. Le spectre obtenu pour ces mesures conserve l'asymétrie et relaxe rapidement à basse température tel que prédit pour un supraconducteur dans la phase d'Abrikosov. Néanmoins, les relaxations produites par ce balayage en température présentent une transition à près de 2 fois la température critique attendue. Dans la deuxième partie de ce mémoire, nous donnons l'interprétation des résultats de la diffraction neutronique inélastique par l'étude des champs électriques cristallins. Ces mesures ont été effectuées sur des aimants frustrés SrHo2O4 et SrDy2O4 sous la forme de poudre. L'étude des niveaux produits par les champs cristallins par la méthode des opérateurs de Stevens indique une perte du moment cinétique dans les deux matériaux. Pour le SrDy2O4, l'état fondamental serait constitué de quatre états dégénérés quasi accidentellement qui portent un moment magnétique total non-nul. Toute fois, nos mesures de susceptibilité magnétique ne montrent aucun ordre au-dessus de 50mK. Pour le SrHo2O4, le fondamental est formé d'une paire accidentelle. Nous obtenons un moment magnétique de 6.94(8)$\mu_B$ ce qui s'accorde avec les données expérimentales.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L’accident vasculaire cérébral (AVC) est une cause principale de décès et de morbidité dans le monde; une bonne partie des AVC est causée par la plaque d’athérosclérose carotidienne. La prévention de l’AVC chez les patients ayant une plaque carotidienne demeure controversée, vu les risques et bénéfices ambigus associés au traitement chirurgical ou médical. Plusieurs méthodes d’imagerie ont été développées afin d’étudier la plaque vulnérable (dont le risque est élevé), mais aucune n’est suffisamment validée ou accessible pour permettre une utilisation comme outil de dépistage. L’élastographie non-invasive vasculaire (NIVE) est une technique nouvelle qui cartographie les déformations (élasticité) de la plaque afin de détecter les plaque vulnérables; cette technique n’est pas encore validée cliniquement. Le but de ce projet est d’évaluer la capacité de NIVE de caractériser la composition de la plaque et sa vulnérabilité in vivo chez des patients ayant des plaques sévères carotidiennes, en utilisant comme étalon de référence, l’imagerie par résonance magnétique (IRM) à haute-résolution. Afin de poursuivre cette étude, une connaissance accrue de l’AVC, l’athérosclérose, la plaque vulnérable, ainsi que des techniques actuelles d’imagerie de la plaque carotidienne, est requise. Trente-et-un sujets ont été examinés par NIVE par ultrasonographie et IRM à haute-résolution. Sur 31 plaques, 9 étaient symptomatiques, 17 contenaient des lipides, et 7 étaient vulnérables selon l’IRM. Les déformations étaient significativement plus petites chez les plaques contenant des lipides, avec une sensibilité élevée et une spécificité modérée. Une association quadratique entre la déformation et la quantité de lipide a été trouvée. Les déformations ne pouvaient pas distinguer les plaques vulnérables ou symptomatiques. En conclusion, NIVE par ultrasonographie est faisable chez des patients ayant des sténoses carotidiennes significatives et peut détecter la présence d’un coeur lipidique. Des études supplémentaires de progression de la plaque avec NIVE sont requises afin d’identifier les plaques vulnérables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mild hypothermia has a protective effect on brain edema and encephalopathy in both experimental and human acute liver failure. The goals of the present study were to examine the effects of mild hypothermia (35°C) on brain metabolic pathways using combined 1H and 13C-Nuclear Magnetic Resonance (NMR) spectroscopy, a technique which allows the study not only of metabolite concentrations but also their de novo synthesis via cell-specific pathways in the brain. :1H and 13C NMR spectroscopy using [1-13C] glucose was performed on extracts of frontal cortex obtained from groups of rats with acute liver failure induced by hepatic devascularization whose body temperature was maintained either at 37°C (normothermic) or 35°C (hypothermic), and appropriate sham-operated controls. At coma stages of encephalopathy in the normothermic acute liver failure animals, glutamine concentrations in frontal cortex increased 3.5-fold compared to sham-operated controls (P < 0.001). Comparable increases of brain glutamine were observed in hypothermic animals despite the absence of severe encephalopathy (coma). Brain glutamate and aspartate concentrations were respectively decreased to 60.9% ± 7.7% and 42.2% ± 5.9% (P < 0.01) in normothermic animals with acute liver failure compared to control and were restored to normal values by mild hypothermia. Concentrations of lactate and alanine in frontal cortex were increased to 169.2% ± 15.6% and 267.3% ± 34.0% (P < 0.01) respectively in normothermic rats compared to controls. Furthermore, de novo synthesis of lactate and alanine increased to 446.5% ± 48.7% and 707.9% ± 65.7% (P < 0.001), of control respectively, resulting in increased fractional 13C-enrichments in these cytosolic metabolites. Again, these changes of lactate and alanine concentrations were prevented by mild hypothermia. Mild hypothermia (35°C) prevents the encephalopathy and brain edema resulting from hepatic devascularization, selectively normalizes lactate and alanine synthesis from glucose, and prevents the impairment of oxidative metabolism associated with this model of ALF, but has no significant effect on brain glutamine. These findings suggest that a deficit in brain glucose metabolism rather than glutamine accumulation is the major cause of the cerebral complications of acute liver failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entailing of phosphorus exchanges in most bio-chemicals as a key factor in disease, increases researcher’s interest to develop the technologies capable of detecting this metabolite. Phosphorus magnetic resonance spectroscopy is able to detect key metabolites in a non-invasive manner. Particularly, it offers the ability to measure the dynamic rate of phosphocreatine(PCr) degeneration through the exercise and recovery. This metric as a valid indication of mitochondrial oxidative metabolism in muscle, differentiate between normal and pathological state. To do magnetic resonance imaging and spectroscopy, clinical research tools provide a wide variety of anatomical and functional contrasts, however they are typically restricted to the tissues containing water or hydrogen atoms and they are still blind to the biochemicals of other atoms of interests. Through this project we intended to obtain the phosphorus spectrum in human body – specificadenerativelly in muscle – using 31P spectroscopy. To do so a double loop RF surface coil, tuned to phosphorus frequency, is designed and fabricated using bench work facilities and then validated through in vitro spectroscopy using 3 Tesla Siemens scanner. We acquired in vitro as well as in vivo phosphorus spectrum in a 100 mM potassium phosphate phantom and human calf muscle in rest-exercise-recovery phase in a 3T MR scanner. The spectrum demonstrates the main constituent in high-energy phosphate metabolism. We also observed the dynamic variation of PCr for five young healthy subjects who performed planter flexions using resistance band during exercise and recovery. The took steps in this project pave the way for future application of spectroscopic quantification of phosphate metabolism in patients affected by carotid artery disease as well as in age-matched control subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La résonance magnétique cardiovasculaire sensible à l'oxygénation (OS-CMR) est devenue une modalité d'imagerie diagnostique pour la surveillance de changements dans l'oxygénation du myocarde. Cette technique offre un grand potentiel en tant qu'outil diagnostic primaire pour les maladies cardiovasculaires, en particulier la détection non-invasive d'ischémie. Par contre, il existe plusieurs facteurs potentiellement confondants de cette technique, quelques-uns d'ordre méthodologique comme les paramètres de séquençage et d'autres de nature physiologiques qui sont peut compris. En raison des effets causés par le contenu tissulaire d'eau, l'état d'hydratation peut avoir un impact sur l'intensité du signal. Ceci est un des aspects physiologiques en particulier dont nous voulions quantifier l'effet confondant par la manipulation de l'état d'hydratation chez des humains et l'observation des changements de l'intensité du signal dans des images OS-CMR. Méthodes: In vitro: Du sang artériel et veineux de huit porcs a été utilisé pour évaluer la dilution en série du sang et son effet correspondant sur l'intensité du signal de la séquence OS. In vivo: Vingt-deux volontaires en santé ont subi OS-CMR. Les concentrations d'hémoglobine (Hb) ont été mesurées au niveau de base et immédiatement après une l'infusion cristalloïde rapide de 1000 mL de solution Lactate Ringer's (LRS). Les images OS-CMR ont été prises dans une vue mid-ventriculaire court axe. L'intensité du signal myocardique a été mesurée durant une rétention respiratoire volontaire maximale, suite à une période d'hyperventilation de 60 secondes. Les changements dans l'intensité du signal entre le début et la fin de la rétention de la respiration ont été exprimés relativement au niveau de base (% de changement). Résultats: L'infusion a résulté en une diminution significative de l'Hb mesurée (142.5±3.3 vs. 128.8±3.3 g/L; p<0.001), alors que l'IS a augmenté de 3.2±1.2% entre les images du niveau de base en normo- et hypervolémie (p<0.05). L'IS d'hyperventilation ainsi que les changements d'IS induits par l'apnée ont été attenués après hémodilution (p<0.05). L'évaluation quantitative T2* a démontré une corrélation négative entre le temps de T2* et la concentration d'hémoglobine (r=-0.46, p<0.005). Conclusions: Il existe plusieurs éléments confondants de la technique OS-CMR qui requièrent de l'attention et de l'optimisation pour une future implémentation clinique à grande échelle. Le statut d'hydratation en particulier pourrait être un élément confondant dans l'imagerie OS-CMR. L'hypervolémie mène à une augmentation en IS au niveau de base et atténue la réponse IS durant des manoeuvres de respiration vasoactives. Cette atténuation de l'intensité du signal devrait être tenue en compte et corrigée dans l'évaluation clinique d'images OS-CMR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for reliable predictions of the solar activity cycle motivates the development of dynamo models incorporating a representation of surface processes sufficiently detailed to allow assimilation of magnetographic data. In this series of papers we present one such dynamo model, and document its behavior and properties. This first paper focuses on one of the model's key components, namely surface magnetic flux evolution. Using a genetic algorithm, we obtain best-fit parameters of the transport model by least-squares minimization of the differences between the associated synthetic synoptic magnetogram and real magnetographic data for activity cycle 21. Our fitting procedure also returns Monte Carlo-like error estimates. We show that the range of acceptable surface meridional flow profiles is in good agreement with Doppler measurements, even though the latter are not used in the fitting process. Using a synthetic database of bipolar magnetic region (BMR) emergences reproducing the statistical properties of observed emergences, we also ascertain the sensitivity of global cycle properties, such as the strength of the dipole moment and timing of polarity reversal, to distinct realizations of BMR emergence, and on this basis argue that this stochasticity represents a primary source of uncertainty for predicting solar cycle characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le foie est un organe vital ayant une capacité de régénération exceptionnelle et un rôle crucial dans le fonctionnement de l’organisme. L’évaluation du volume du foie est un outil important pouvant être utilisé comme marqueur biologique de sévérité de maladies hépatiques. La volumétrie du foie est indiquée avant les hépatectomies majeures, l’embolisation de la veine porte et la transplantation. La méthode la plus répandue sur la base d'examens de tomodensitométrie (TDM) et d'imagerie par résonance magnétique (IRM) consiste à délimiter le contour du foie sur plusieurs coupes consécutives, un processus appelé la «segmentation». Nous présentons la conception et la stratégie de validation pour une méthode de segmentation semi-automatisée développée à notre institution. Notre méthode représente une approche basée sur un modèle utilisant l’interpolation variationnelle de forme ainsi que l’optimisation de maillages de Laplace. La méthode a été conçue afin d’être compatible avec la TDM ainsi que l' IRM. Nous avons évalué la répétabilité, la fiabilité ainsi que l’efficacité de notre méthode semi-automatisée de segmentation avec deux études transversales conçues rétrospectivement. Les résultats de nos études de validation suggèrent que la méthode de segmentation confère une fiabilité et répétabilité comparables à la segmentation manuelle. De plus, cette méthode diminue de façon significative le temps d’interaction, la rendant ainsi adaptée à la pratique clinique courante. D’autres études pourraient incorporer la volumétrie afin de déterminer des marqueurs biologiques de maladie hépatique basés sur le volume tels que la présence de stéatose, de fer, ou encore la mesure de fibrose par unité de volume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current water treatment technology is oriented towards the removal of contaminants, mostly organic compounds, by activated carbon. Activated carbons are classified as Granular Activated Carbons (GAC) and Powdered Activated Carbons (PAC) on the basis of the particle size of the carbon granules. Powdered carbons are generally less expensive than granular carbon, operating costs with powdered carbon could be lower. Though powdered activated carbon has many advantages over granular carbon, its application in large-scale separation process is limited by difficulty in recovery and regeneration. Deposition of magnetic iron oxide on carbon particles provides a convenient way of recovering the spent carbon from process water. The study deals with the preparation and physico-chemical characterization of magnetic iron oxide loaded activated carbons. The evaluation of absorption properties of magnetic iron oxide loaded activated carbon composites. The target molecules studied were phenol, p-nitro phenol and methylene blue. The feasibility of magnetic separation of iron oxide loaded activated carbons were studied and described in this thesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is an attempt to understand the characteristics of high energy ball milling on the structural, electrical and magnetic properties of some normal spinets in the ultra fine regime, Magnetism and magnetic materials have been a fascinating subject for the mankind ever since the discovery of lodestone. Since then, man has been applying this principle of magnetism to build devices for various applications. Magnetism can be classified broadly into five categories. They are diamagnetic, paramagnetic, ferromagnetic antiferromagnetic and ferrimagnetic. Of these, ferro and ferri magnetic materials assume great commercial importance due to their unique properties like appropriate magnetic characteristics, high resistivity and low eddy current losses. The emergence of nanoscience and nanotechnology during the last decade had its impact in the field of magnetism and magnetic materials too. Now, it is common knowledge that materials synthesized in the nanoregime exhibit novel and superlative properties with respect to their coarser sized counterparts in the micron regime. These studies reveal that dielectric properties can be varied appreciably by high-energy ball milling in nanosized zinc ferrites produced by coprecipitation method. A semi conducting behaviour was observed in these materials with the Oxygen vacancies acting as the main charge carrier for conduction, which was produced at the time of coprecipitation and milling. Thus through this study, it was possible to successfully investigate the finite size effects on the structural, electrical and magnetic properties of normal spinels in the ultra fine regime