891 resultados para limits of visual detection
Resumo:
A study on the presence of herbicides, namely simazine, metribuzin, metolachlor, trifluralin, atrazine and two metabolites, deisopropylatrazine (DIA) and deethylatrazine (DEA), was performed in ground and surface waters from Primavera do Leste region, Mato Grosso state (Middle West of Brazil). The analytical procedure was based on solid-phase extraction (SPE) with Sep-Pak C18 disposable cartridges and ethyl acetate for elution solvent. Residue levels were determined by gas chromatography with nitrogen-phosphorus detection. For most of the pesticides average recoveries at different fortification levels were >with relative standard deviation < The recoveries of DIA and trifluralin in water were 25% and 56%, respectively, which were attributed to the incomplete retention of DIA and strong retention on the sorbing material and high volatility of trifluralin. Detection limits ranged from 0.023 to 0.088 μg L-1. This method was applied for the analysis of 5 superficial water samples and 28 groundwater samples, in places used for human consumption without previous treatment, collected in Primavera do Leste, Mato Grosso, Brazil. Results indicated that the highest level of contamination in a water sample was 1.732 μg L-1 for metolachlor, while metribuzin was the most frequently detected herbicide with maximum concentration of 0.351 μg L-1. ©2006 Sociedade Brasileira de Química.
Resumo:
Visual communication seems to be widespread among nocturnal anurans, however, reports of these behaviors in many Neotropical species are lacking. Therefore, we gathered information collected during several sporadic field expeditions in central and southern Brazil with three nocturnal tree frogs: Aplastodiscus perviridis, Hypsiboas albopunctatus and H. bischoffi. These species displayed various aggressive behaviors, both visual and acoustic, towards other males. For A. perviridis we described arm lifting and leg kicking; for H. albopunctatus we described the advertisement and territorial calls, visual signalizations, including a previously unreported behavior (short leg kicking), and male-male combat; and for H. bischoffi we described the advertisement and fighting calls, toes and fingers trembling, leg lifting, and leg kicking. We speculate about the evolution of some behaviors and concluded that the use of visual signals among Neotropical anurans may be much more common than suggested by the current knowledge. © 2007 Departamento de Ciências Biológicas.
Resumo:
The present work develops and optimizes a method to determine copper in samples of feces and fish feed by graphite furnace atomic absorption spectrometry (GFAAS) through the direct introduction of slurries of the samples into the spectrometer's graphite tube coated internally with metallic rhodium and tungsten carbide that acts as chemical modifiers. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (0.50% m/v of feces or feed devoid of copper) were 0.24 and 0.79 μg L -1 for the standard feces slurries and 0.26 and 0.87 μg L -1 for the standard feed slurries. The proposed method was applied in studies of absorption of copper in different fish feeds and their results proved compatible with that obtained from samples mineralized by acid digestion using microwave oven. © Springer Science+Business Media, LLC 2008.
Resumo:
A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000 μL were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes (≥300 μL) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n = 73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. © 2010 Springer-Verlag.
Resumo:
This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324. 754 nm, 327. 396 nm, 222. 570 nm, 249. 215 nm and 224. 426 nm were evaluated and main figures of merit established. Absorbance measurements at 324. 754 nm, 249. 215 nm and 224. 426 nm allows the determination of Cu in the 0. 07-5. 0 mg L -1, 5. 0-100 mg L -1 and 100-800 mg L -1 concentration intervals respectively with linear correlation coefficients better than 0. 998. Limits of detection were 21 μg L -1, 310 μg L -1 and 1400 μg L -1 for 324. 754 nm, 249. 215 nm and 224. 426 nm, respectively and relative standard deviations (n = 12) were ≤ 2. 7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry.
Resumo:
A simple method to determine Cu, Fe, Mn and Zn in single aliquots of medicinal plants by HR-CS FAAS is proposed. The main lines for Cu, Mn and Zn, and the alternate line measured at the wing of the main line for Fe at 248.327 nm allowed calibration within the 0.025 - 2.0 mg L-1 Cu, 1.0 - 20.0 mg L-1 Fe, 0.05 - 2.0 mg L-1 Mn, 0.025 - 0.75 mg L-1 Zn ranges. Nineteen medicinal plants and two certified plant reference materials were analyzed. Results were in agreement at a 95% confidence level (paired t-test) with reference values. Limits of detection were 0.12 μg L-1 Cu, 330 μg L-1 Fe, 1.42 μg L-1 Mn and 8.12 μg L-1 Zn. Relative standard deviations (n=12) were ≤ 3% for all analytes. Recoveries in the 89 - 105% (Cu), 95 - 108% (Fe), 94 - 107% (Mn), and 93 - 110% (Zn) ranges were obtained.
Resumo:
Synchronous generators are essential components of electric power systems. They are present both in hydro and thermal power plants, performing the function of converting mechanical into electrical energy. This paper presents a visual approach to manipulate parameters that affect operation limits of synchronous generators, using a specifically designed software. The operating characteristics of synchronous generators, for all possible modes of operation, are revised in order to link the concepts to the graphic objects. The approach matches the distance learning tool requirements and also enriches the learning process by developing student trust and understanding of the concepts involved in building synchronous machine capability curves. © 2012 IEEE.
Resumo:
Recently, considerable research work have been conducted towards finding fast and accurate pattern classifiers for training Intrusion Detection Systems (IDSs). This paper proposes using the so called Fuzzy ARTMAT classifier to detect intrusions in computer network. Our investigation shows, through simulations, how efficient such a classifier can be when used as the learning mechanism of a typical IDS. The promising evaluation results in terms of both detection accuracy and training duration indicate that the Fuzzy ARTMAP is indeed viable for this sort of application.
Resumo:
Chromatographic and electroanalytical methods were developed to detect and quantify Sudan II (SD-II) dye in fuel ethanol samples. Sudan II is reduced at +0.50 V vs. Ag/AgCl on a glassy carbon electrode using Britton-Robinson buffer (pH 4.0) and N,N-dimethylformamide (70:30, v/v) + sodium dioctyl sulfosuccinate surfactant as supporting electrolyte, due to the azo group. This is the basis for its determination by square-wave voltammetry (SWV). Using the optimized conditions, it is possible to get a linear calibration curve from 3.00×10-6 to 1.80×10-5 mol L-1 (r = 0.998) with limits of detection (LOD) and quantification (LOQ) of 2.05×10-6 and 6.76×10-6 mol L-1, respectively. In addition, the hydroxyl substituent in the SD-II dye is also oxidized at +0.85 V vs. Ag/AgCl, which was conveniently used for its determination by high-performance liquid chromatography coupled to electrochemical detection (HPLC-ED). Under the optimized condition, the SD-II dye was eluted and separated using a reversed-phase column (cyanopropyl, CN) using isocratic elution with the mobile phase containing acetonitrile and aqueous lithium chloride (5.00×10-4 mol L-1) at 70:30 (v/v) and a flow rate of 1.2 mL min-1. Linear calibration curves were obtained from 3.00×10-7 to 2.00×10-6 mol L-1 (r = 0.999) with LOD and LOQ of 3.10×10-8 and 1.05×10-7 mol L-1, respectively. Both methods were simple, fast and suitable to detect and quantify the dye in fuel ethanol samples at recovery values between 83.0 to 102% (SWV) and 88.0 to 112% (HPLC-ED) with satisfactory precision and accuracy.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of tigecycline in lyophilized powder. The LC method was conducted on a Luna C18 column (250 × 4.6 mm i.d.), maintained at room temperature. The mobile phase consisted of buffer containing sodium phosphate monobasic (0.015M) and oxalic acid (0.015M) (pH 7.0)-acetonitrile (75:25, v/v), run at a flow rate of 1.0 mL/min and using ultraviolet detection at 280 nm. The chromatographic separation was obtained with a retention time of 8.6 min, and was linear in the range of 40-100 μg/mL (r2 = 0.9997). The specificity and stability-indicating capability of the method was proven through forced degradation studies, which also showed no interference of the excipients. The accuracy was 99.01% with a bias lower than 1.81%. The limits of detection and quantitation were 1.67 and 5.05 μg/mL, respectively. Moreover, method validation demonstrated satisfactory results for precision and robustness. The proposed method was applied for the analysis of the lyophilized powder formulation, contributing to improve the quality control and to assure the therapeutic efficacy. © The Author [2012]. Published by Oxford University Press. All rights reserved.
Resumo:
In the present study, a simple, rapid and sensitive method was developed for the determination of mercury concentrations in the muscle tissue of fish from the Brazilian Amazon using graphite furnace atomic absorption spectrometry (GFAAS) following acid mineralization of the samples in an ultrasonic cold water bath. Using copper nitrate as a chemical modifier in solution and sodium tungstate as permanent modifier, we were able to attain thermal stabilization of the mercury up to the atomisation temperature of 1600 °C in the GFAAS assay. The calculated limits of detection (LOD) and quantification (LOQ) were 0.014 and 0.047 mg kg-1, respectively. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
Different conditions of extraction using water, a methanol-water mixture and nitric acid solutions were evaluated for speciation of As(iii), As(v), DMA and MMA in plant samples that previously received As(v) after being sown and emergence was investigated. Microwave-assisted extraction (MAE) using diluted nitric acid solutions was also performed for arsenic extraction from chicken feed samples. The separation and determination of arsenic species were performed using HPLC-ICP-MS. The interference standard method (IFS) using 83Kr+ as the IFS probe was employed to minimize spectral interferences caused by polyatomic species, such as 40Ar 35Cl+. The extraction procedures tested presented adequate extraction efficiencies (90%), and the four arsenic species evaluated were found in plant samples. Extractions with diluted nitric acid solution at 90 °C were the most efficient strategy, with quantitative recoveries for all four As species in plant tissues. On the other hand, the methanol-water mixture was the solvent with the lowest extraction efficiency (50-60%). For chicken feed samples, MAE at 100 °C for 30 min resulted in an extraction efficiency of 97% and only As(v) was found, without any species interconversion. The IFS method contributed to improving precision and limits of detection and quantification for all tested extraction procedures. Significant improvements on accuracy were obtained by applying the IFS method and recoveries between 77 and 94%, and 82 and 93% were obtained for plant extracts and chicken feed samples, respectively. This journal is © 2013 The Royal Society of Chemistry.
Resumo:
Different solid composites made by mechanical dispersions of graphite particles into heated paraffin (from 65 to 80% graphite, in mass) were prepared and assessed in order to optimize their use in electrochemical and electroanalytical procedures for bioanalysis. Besides these, composites were also evaluated by thermoanalytical techniques aiming to study their conservation and long-term stability (over eight months without special care), among others. Best results were found at 80% m/m graphite in paraffin. Such electrode combines low-cost, stability, sensitivity, ease of maintenance and clearance, besides the possibilities of manufacture in many different forms and shapes (with or without modifications) and applicability in a wide range of pH. Electrochemical studies by different voltammetric techniques involving vitamins from complex B (riboflavin and pyridoxine) leaded to a better understanding about their electrooxidative processes onto carbon-composite electrodes, specially regarding reversibility and pH-dependence. Data were also acquired and optimized with analytical purposes, being square-wave voltammetry in pH 4.2 chosen by its many advantages. Good linearity between peak responses as function of concentration were reached from 5 to 43 μmol L-1 for riboflavin (peak at -0.257 V) and up to 8.5 × 10-4 mol L -1 for pyridoxine (peak at +1.04 V), best studied conditions; limits of detection (at an S/N of 3) for both analites showed to be circa 1.0 mol L-1. Different commercial samples were analyzed for riboflavin (EMS® complex B syrup) and pyridoxine (Citoneurin 5000 Merck® ampoules) providing 96.6% and 98.7% recoveries, respectively.
Resumo:
The development of an electroanalytical method for simultaneous determination of copper and lead ions in sugar cane spirit (cachaça) using carbon paste electrode modified with ascorbic acid and carbon nanotubes (CPE-AaCNT) is described. Squarewave voltammetry (SWV) with anodic stripping was employed, and this technique was optimized with respect to the following parameters: frequency (50 Hz), amplitude (100 mV) and scan increment (9 mV). The analytical curves were linear in the range from 0.0900 to 7.00 mg L - 1 for lead and copper. The limits of detection were 48.5 and 23.9 µg L - 1 for lead and copper, respectively. The developed method was applied to the simultaneous determination of copper and lead in five commercial samples of sugar cane spirit. The results were in good agreement with those obtained by F AAS/GF AAS (flame atomic absorption spectrometry/graphite furnace atomic absorption spectrometry) and showed that CPE-AaCNT can be successfully employed in the simultaneous determination of these metals in real sugar cane spirit samples.