922 resultados para high power drives for trolleybus systems


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper analyzes the asymptotic performance of maximum likelihood (ML) channel estimation algorithms in wideband code division multiple access (WCDMA) scenarios. We concentrate on systems with periodic spreading sequences (period larger than or equal to the symbol span) where the transmitted signal contains a code division multiplexed pilot for channel estimation purposes. First, the asymptotic covariances of the training-only, semi-blind conditional maximum likelihood (CML) and semi-blind Gaussian maximum likelihood (GML) channelestimators are derived. Then, these formulas are further simplified assuming randomized spreading and training sequences under the approximation of high spreading factors and high number of codes. The results provide a useful tool to describe the performance of the channel estimators as a function of basicsystem parameters such as number of codes, spreading factors, or traffic to training power ratio.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Finnish food producers' trade with Russia has experienced profound changes since the collapse of the Soviet Union. Simultaneously, the distribution systems of foodstuffs have changed remarkably. This study sheds some light into these changes and analyses the current situation in distribution systems of foodstuffs in Russia. In addition, the study discusses the possibilities of Finnish food producers to get more of their products to the shelves of Russian food retail stores. Before the 1998 financial crisis, the import of foreign foodstuffs was booming in Russia due to the overvalued rouble. As a result of the financial crisis, food import collapsed. The export of Finnish foodstuffs to Russia has been slowly recovering during the past few years, but in the most important product categories the pre-crisis levels have so far not been reached and maybe will not be reached. In certain product categories the growth has been only marginal. It seems that starting localproduction will become increasingly important in the future. This is further encouraged by the fact that Russian consumers favour domestic food products. Russian consumers are very price conscious and demand quality in food products. The perceived price-quality ratio is an important criterion in the purchase decision.The majority of foodstuff retail is still conducted via unorganised forms of trade (e.g. kiosks and marketplaces) but modern retail chains are developing at a fast pace in Russia. They are also expected to dominate the retail trade in foodstuffs over the unorganised forms of trade in the future. This will change the distribution systems as well. The retail chains are trying to shorten the distribution chain, similarly to what has been seen in the Western countries. This together with the strengthening of retail chains is likely to shrink the role of wholesalers, as the chains increasingly want to work directly with the producers. Many large retail chains are acquiring or have already acquired a distribution centre or centres in order to boost efficiency and control the flow of products. The strengthening of the retail chains also gives them power in negotiations, which the producers and distributors have to adjust to. For example store entry fees and retail chains' own private label products pose challenges to the food producers. In the food production sector the competition is fierce, as large Russianand foreign producers want to ensure their piece of the market. The largest producers utilise their size: they invest in big marketing campaigns and are willing to pay high entry fees to retail chains in order to secure a place on the store shelves and to build a strong brand in Russia. This complicates the situation from the viewpoint of small producers. Currently, the most popular type of distribution system among the interviewed Finnish food producers is based on a network of local distributors. There is, however, a strong consensus on the importanceof starting local production in order to be a serious actor in Russia in the future. Factors that hinder the starting of local production include the lack of local infrastructure and qualified staff, and the low risk tolerance of Finnish firms. Major barriers for entry in Russia are the actions of authorities, fierce competition, fragmented market and Finnish producers' heavy production costs. The suggested strategies for increasing the market share include focusing geographically or segment-wise, introducing new products, starting local production, andcooperation between Finnish producers. Smallness was one reason why Finnish producers had to cut down their operations in Russia due to the 1998 crisis. Smaller producers had fewer resources to tolerate losses during the period of crisis. Smallness is reflected also on trade negotiations with retail chains and distributors. It makes it harder to cope with the store entry fees and to differentiatefrom the mass of products propped up by expensive advertising. Finally, it makes it harder for Finnish producers to start or expand local production, as it is more difficult for a small producer to get financing and to tolerate the increased risks. Compensating for the smallness might become the crucial factor determining the future success of Finnish food producers in the Russian market.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

During the latest few years the need for new motor types has grown, since both high efficiency and an accurate dynamic performance are demanded in industrial applications. For this reason, new effective control systems such as direct torque control (DTC) have been developed. Permanent magnet synchronous motors (PMSM) are well suitable for new adjustable speed AC inverter drives, because their efficiency and power factor are not depending on the pole pair number and speed to the same extent as it is the case in induction motors. Therefore, an induction motor (IM) with a mechanical gearbox can often be replaced with a direct PM motor drive. Space as well as costs will be saved, because the efficiency increases and the cost of maintenance decreases as well. This thesis deals with design criterion, analytical calculation and analysis of the permanent magnet synchronous motor for both sinusoidal air-gap flux density and rectangular air-gapflux density. It is examined how the air-gap flux, flux densities, inductances and torque can be estimated analytically for salient pole and non-salient pole motors. It has been sought by means of analytical calculations for the ultimate construction for machines rotating at relative low 300 rpm to 600 rpm speeds, which are suitable speeds e.g. in Pulp&Paper industry. The calculations are verified by using Finite Element calculations and by measuring of prototype motor. The prototype motor is a 45 kW, 600 rpm PMSM with buried V-magnets, which is a very appropriate construction for high torque motors with a high performance. With the purposebuilt prototype machine it is possible not only to verify the analytical calculations but also to show whether the 600 rpm PMSM can replace the 1500 rpm IM with a gear. It can also be tested if the outer dimensions of the PMSM may be the same as for the IM and if the PMSM in this case can produce a 2.5 fold torque, in consequence of which it may be possible to achieve the same power. The thesis also considers the question how to design a permanent magnet synchronous motor for relatively low speed applications that require a high motor torqueand efficiency as well as bearable costs of permanent magnet materials. It is shown how a selection of different parameters affects the motor properties. Key words: Permanent magnet synchronous motor, PMSM, surface magnets, buried magnets

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Design aspects of the Transversally Laminated Anisotropic (TLA) Synchronous Reluctance Motor (SynRM) are studied and the machine performance analysis compared to the Induction Motor (IM) is done. The SynRM rotor structure is designed and manufactured for a30 kW, four-pole, three-phase squirrel cage induction motor stator. Both the IMand SynRM were supplied by a sensorless Direct Torque Controlled (DTC) variablespeed drive. Attention is also paid to the estimation of the power range where the SynRM may compete successfully with a same size induction motor. A technicalloss reduction comparison between the IM and SynRM in variable speed drives is done. The Finite Element Method (FEM) is used to analyse the number, location and width of flux barriers used in a multiple segment rotor. It is sought for a high saliency ratio and a high torque of the motor. It is given a comparison between different FEM calculations to analyse SynRM performance. The possibility to take into account the effect of iron losses with FEM is studied. Comparison between the calculated and measured values shows that the design methods are reliable. A new application of the IEEE 112 measurement method is developed and used especially for determination of stray load losses in laboratory measurements. The study shows that, with some special measures, the efficiency of the TLA SynRM is equivalent to that of a high efficiency IM. The power factor of the SynRM at rated load is smaller than that of the IM. However, at lower partial load this difference decreases and this, probably, brings that the SynRM gets a better power factor in comparison with the IM. The big rotor inductance ratio of the SynRM allows a good estimating of the rotor position. This appears to be very advantageous for the designing of the rotor position sensor-less motor drive. In using the FEM designed multi-layer transversally laminated rotor with damper windings it is possible to design a directly network driven motor without degrading the motorefficiency or power factor compared to the performance of the IM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Teollusuussovelluksissa vaaditaan nykyisin yhä useammin reaaliaikaista tiedon käsittelyä. Luotettavuus on yksi tärkeimmistä reaaliaikaiseen tiedonkäsittelyyn kykenevän järjestelmän ominaisuuksista. Sen saavuttamiseksi on sekä laitteisto, että ohjelmisto testattava. Tämän työn päätavoitteena on laitteiston testaaminen ja laitteiston testattavuus, koska luotettava laitteistoalusta on perusta tulevaisuuden reaaliaikajärjestelmille. Diplomityössä esitetään digitaaliseen signaalinkäsittelyyn soveltuvan prosessorikortin suunnittelu. Prosessorikortti on tarkoitettu sähkökoneiden ennakoivaa kunnonvalvontaa varten. Uusimmat DFT (Desing for Testability) menetelmät esitellään ja niitä sovelletaan prosessorikortin sunnittelussa yhdessä vanhempien menetelmien kanssa. Kokemukset ja huomiot menetelmien soveltuvuudesta raportoidaan työn lopussa. Työn tavoitteena on kehittää osakomponentti web -pohjaiseen valvontajärjestelmään, jota on kehitetty Sähkötekniikan osastolla Lappeenrannan teknillisellä korkeakoululla.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Diplomityön tarkoituksena oli kuidutusrumpulaitteiston käytön- ja kannatuksen kehittä-minen. Työ rajattiin laajuutensa vuoksi koskemaan tuotesarjan viittä pienintä kokoa. Työn alkuosassa käsitellään kuidutuksen teoriaa ja siihen soveltuvia laitteistoja. Käytön suunnittelun kannalta olennaista käynnistystehon tarvetta on tarkasteltu lähtökohdaisesti fysiikan avulla. Perustietoja teorialle on haettu aiemmista tutkimuksista sekä kirjallisuu-desta. Tarkastelun tuloksena teoriaa on kehitty ja se on saatu vastaamaan todellisuutta aiempaa paremmin. Kannatuksen ja käytön toteuttamisvaihtoja etsittäessä on käytetty systemaattisen koneen-suunnittelun keinoja. Saatuja ideoita on arvioitu teknillis-taloudellisin perustein ja näistä on valittu parhaat vaihtoehdot jatkokehitykseen. Jatkokehitysvaiheessa ratkaisuvaihto-ehtoja on tarkasteltu komponenttitasolla ja näistä on tehty yksityiskohtaiset kustannus-laskelmat. Työn tuloksena on esitetty kannatuksen ja käytön toteutusvaihtoehto, jonka avulla voidaan saavuttaa merkittäviä kustannussäästöjä. Korkea, 30 prosentin kustannussäästö-tavoite saavutettiin.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As the world’s energy demand is increasing, a durable solution to control it is to improve the energy efficiency of the processes. It has been estimated that pumping applications have a significant potential for energy savings trough equipment or control system changes. For many pumping application the use of a variable speed drive as a process control element is the most energy efficient solution. The main target of this study is to examine the energy efficiency of a drive system that moves the pump. In a larger scale the purpose of this study is to examine how the different manufacturers’ variable speed drives are functioning as a control device of a pumping process. The idea is to compare the drives from a normal pump user’s point of view. The things that are mattering for the pump user are the efficiency gained in the process and the easiness of the use of the VSD. So some thought is given also on valuating the user-friendliness of the VSDs. The VSDs are compared to each other also on the basis of their life cycle energy costs in different kind of pumping cases. The comparison is made between ACS800 from ABB, VLT AQUA Drive from Danfoss, NX-drive from Vacon and Micromaster 430 from Siemens. The efficiencies are measured in power electronics laboratory in the Lappeenranta University of Technology with a system that consists of a variable speed drive, an induction motor with dc-machine, two power analyzers and a torque transducer. The efficiencies are measured as a function of a load at different frequencies. According to measurement results the differences between the measured system efficiencies on the actual working area of pumping are on average few percent units. When examining efficiencies at the whole range of different loads and frequencies, the differences get bigger. At low frequencies and loads the differences between the most efficient and the least efficient systems are at the most about ten percent units. At the most of the tested points ABB’s drive seem to have slightly better efficiencies than the other drives.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Data transmission between an electric motor and a frequency converter is required in variablespeed electric drives because of sensors installed at the motor. Sensor information can be used for various useful applications to improve the system reliability and its properties. Traditionally, the communication medium is implemented by an additional cabling. However, the costs of the traditional method may be an obstacle to the wider application of data transmission between a motor and a frequency converter. In any case, a power cable is always installed between a motor and a frequency converter for power supply, and hence it may be applied as a communication medium for sensor level data. This thesis considers power line communication (PLC) in inverter-fed motor power cables. The motor cable is studied as a communication channel in the frequency band of 100 kHz−30 MHz. The communication channel and noise characteristics are described. All the individual components included in a variable-speed electric drive are presented in detail. A channel model is developed, and it is verified by measurements. A theoretical channel information capacity analysis is carried out to estimate the opportunities of a communication medium. Suitable communication and forward error correction (FEC) methods are suggested. A general method to implement a broadband and Ethernet-based communication medium between a motor and a frequency converter is proposed. A coupling interface is also developed that allows to install the communication device safely to a three-phase inverter-fed motor power cable. Practical tests are carried out, and the results are analyzed. Possible applications for the proposed method are presented. A speed feedback motor control application is verified in detail by simulations and laboratory tests because of restrictions for the delay in the feedback loop caused by PLC. Other possible applications are discussed at a more general level.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Through indisputable evidence of climate change and its link to the greenhouse gas emissions comes the necessity for change in energy production infrastructure during the coming decades. Through political conventions and restrictions energy industry is pushed toward using bigger share of renewable energy sources as energy supply. In addition to climate change, sustainable energy supply is another major issue for future development plans, but neither of these should come with unbearable price. All the power production types have environmental effects as well as strengths and weaknesses. Although each change comes with a price, right track in minimising the environmental impacts and energy supply security can be found by combining all possible low-carbon technologies and by improving energy efficiency in all sectors, for creating a new power production infrastructure of tolerable energy price and of minor environmental effects. GEMIS-Global Emission Model for Integrated Systems is a life-cycle analysis program which was used in this thesis to make indicative energy models for Finland’s future energy supply. Results indicate that the energy supply must comprise both high capacity nuclear power as well as large variation of renewable energy sources for minimization of all environmental effects and keeping energy price reasonable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Synchronous motors are used mainly in large drives, for example in ship propulsion systems and in steel factories' rolling mills because of their high efficiency, high overload capacity and good performance in the field weakening range. This, however, requires an extremely good torque control system. A fast torque response and a torque accuracy are basic requirements for such a drive. For large power, high dynamic performance drives the commonly known principle of field oriented vector control has been used solely hitherto, but nowadays it is not the only way to implement such a drive. A new control method Direct Torque Control (DTC) has also emerged. The performance of such a high quality torque control as DTC in dynamically demanding industrial applications is mainly based on the accurate estimate of the various flux linkages' space vectors. Nowadays industrial motor control systems are real time applications with restricted calculation capacity. At the same time the control system requires a simple, fast calculable and reasonably accurate motor model. In this work a method to handle these problems in a Direct Torque Controlled (DTC) salient pole synchronous motor drive is proposed. A motor model which combines the induction law based "voltage model" and motor inductance parameters based "current model" is presented. The voltage model operates as a main model and is calculated at a very fast sampling rate (for example 40 kHz). The stator flux linkage calculated via integration from the stator voltages is corrected using the stator flux linkage computed from the current model. The current model acts as a supervisor that prevents only the motor stator flux linkage from drifting erroneous during longer time intervals. At very low speeds the role of the current model is emphasised but, nevertheless, the voltage model always stays the main model. At higher speeds the function of the current model correction is to act as a stabiliser of the control system. The current model contains a set of inductance parameters which must be known. The validation of the current model in steady state is not self evident. It depends on the accuracy of the saturated value of the inductances. Parameter measurement of the motor model where the supply inverter is used as a measurement signal generator is presented. This so called identification run can be performed prior to delivery or during drive commissioning. A derivation method for the inductance models used for the representation of the saturation effects is proposed. The performance of the electrically excited synchronous motor supplied with the DTC inverter is proven with experimental results. It is shown that it is possible to obtain a good static accuracy of the DTC's torque controller for an electrically excited synchronous motor. The dynamic response is fast and a new operation point is achieved without oscillation. The operation is stable throughout the speed range. The modelling of the magnetising inductance saturation is essential and cross saturation has to be considered as well. The effect of cross saturation is very significant. A DTC inverter can be used as a measuring equipment and the parameters needed for the motor model can be defined by the inverter itself. The main advantage is that the parameters defined are measured in similar magnetic operation conditions and no disagreement between the parameters will exist. The inductance models generated are adequate to meet the requirements of dynamically demanding drives.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Condition monitoring systems for physical assets are constantly becoming more and more common in the industrial sector. At the same time an increasing portion of asset monitoring systems are being remotely supported. As global competitors are actively developing solutions for condition monitoring and condition-based maintenance, which it enables, Wärtsilä too feels the pressure to provide customers with more sophisticated condition-based maintenance solutions. The main aim of this thesis study is to consider Wärtsilä remote condition monitoring solutions and how they relate to similar solutions from other suppliers and end customers’ needs, in the context of offshore assets. A theoretical study is also included in the thesis, where the concepts of condition monitoring, condition-based maintenance, maintenance management and physical asset management are introduced.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study compares different electric propulsion systems. Results of the analysis of all the advantages and disadvantages of the different propulsion systems are given. This thesis estimates possibilities to apply different diesel-electric propulsion concepts for different vessel types. Small and medium size vessel’s power ranges are studied. The optimal delivery system is chosen. This choice is made on the base of detailed study of the concepts, electrical equipment market and comparison of mass, volume and efficiency parameters. In this thesis three marine generators are designed. They are: salient pole synchronous generator and two permanent magnet synchronous generators. Their electrical, dimensional, cost and efficiency parameters are compared. To understand all the benefits diagrams with these parameters are prepared. Possible benefits and money savings are estimated. As the result the advantages, disadvantages and boundary conditions for the permanent magnet synchronous generator application in marine electric-power systems are found out.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One of the targets of the climate and energy package of the European Union is to increase the energy efficiency in order to achieve a 20 percent reduction in primary energy use compared with the projected level by 2020. The energy efficiency can be improved for example by increasing the rotational speed of large electrical drives, because this enables the elimination of gearboxes leading to a compact design with lower losses. The rotational speeds of traditional bearings, such as roller bearings, are limited by mechanical friction. Active magnetic bearings (AMBs), on the other hand, allow very high rotational speeds. Consequently, their use in large medium- and high-speed machines has rapidly increased. An active magnetic bearing rotor system is an inherently unstable, nonlinear multiple-input, multiple-output system. Model-based controller design of AMBs requires an accurate system model. Finite element modeling (FEM) together with the experimental modal analysis provides a very accurate model for the rotor, and a linearized model of the magneticactuators has proven to work well in normal conditions. However, the overall system may suffer from unmodeled dynamics, such as dynamics of foundation or shrink fits. This dynamics can be modeled by system identification. System identification can also be used for on-line diagnostics. In this study, broadband excitation signals are adopted to the identification of an active magnetic bearing rotor system. The broadband excitation enables faster frequency response function measurements when compared with the widely used stepped sine and swept sine excitations. Different broadband excitations are reviewed, and the random phase multisine excitation is chosen for further study. The measurement times using the multisine excitation and the stepped sine excitation are compared. An excitation signal design with an analysis of the harmonics produced by the nonlinear system is presented. The suitability of different frequency response function estimators for an AMB rotor system are also compared. Additionally, analytical modeling of an AMB rotor system, obtaining a parametric model from the nonparametric frequency response functions, and model updating are discussed in brief, as they are key elements in the modeling for a control design. Theoretical methods are tested with a laboratory test rig. The results conclude that an appropriately designed random phase multisine excitation is suitable for the identification of AMB rotor systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Prostate cancers form a heterogeneous group of diseases and there is a need for novel biomarkers, and for more efficient and targeted methods of treatment. In this thesis, the potential of microarray data, RNA interference (RNAi) and compound screens were utilized in order to identify novel biomarkers, drug targets and drugs for future personalized prostate cancer therapeutics. First, a bioinformatic mRNA expression analysis covering 9873 human tissue and cell samples, including 349 prostate cancer and 147 normal prostate samples, was used to distinguish in silico prevalidated putative prostate cancer biomarkers and drug targets. Second, RNAi based high-throughput (HT) functional profiling of 295 prostate and prostate cancer tissue specific genes was performed in cultured prostate cancer cells. Third, a HT compound screen approach using a library of 4910 drugs and drug-like molecules was exploited to identify potential drugs inhibiting prostate cancer cell growth. Nine candidate drug targets, with biomarker potential, and one cancer selective compound were validated in vitro and in vivo. In addition to androgen receptor (AR) signaling, endoplasmic reticulum (ER) function, arachidonic acid (AA) pathway, redox homeostasis and mitosis were identified as vital processes in prostate cancer cells. ERG oncogene positive cancer cells exhibited sensitivity to induction of oxidative and ER stress, whereas advanced and castrate-resistant prostate cancer (CRPC) could be potentially targeted through AR signaling and mitosis. In conclusion, this thesis illustrates the power of systems biological data analysis in the discovery of potential vulnerabilities present in prostate cancer cells, as well as novel options for personalized cancer management.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Transportation of fluids is one of the most common and energy intensive processes in the industrial and HVAC sectors. Pumping systems are frequently subject to engineering malpractice when dimensioned, which can lead to poor operational efficiency. Moreover, pump monitoring requires dedicated measuring equipment, which imply costly investments. Inefficient pump operation and improper maintenance can increase energy costs substantially and even lead to pump failure. A centrifugal pump is commonly driven by an induction motor. Driving the induction motor with a frequency converter can diminish energy consumption in pump drives and provide better control of a process. In addition, induction machine signals can also be estimated by modern frequency converters, dispensing with the use of sensors. If the estimates are accurate enough, a pump can be modelled and integrated into the frequency converter control scheme. This can open the possibility of joint motor and pump monitoring and diagnostics, thereby allowing the detection of reliability-reducing operating states that can lead to additional maintenance costs. The goal of this work is to study the accuracy of rotational speed, torque and shaft power estimates calculated by a frequency converter. Laboratory tests were performed in order to observe estimate behaviour in both steady-state and transient operation. An induction machine driven by a vector-controlled frequency converter, coupled with another induction machine acting as load was used in the tests. The estimated quantities were obtained through the frequency converter’s Trend Recorder software. A high-precision, HBM T12 torque-speed transducer was used to measure the actual values of the aforementioned variables. The effect of the flux optimization energy saving feature on the estimate quality was also studied. A processing function was developed in MATLAB for comparison of the obtained data. The obtained results confirm the suitability of this particular converter to provide accurate enough estimates for pumping applications.