909 resultados para hemodynamic measurements


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 μm standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1μW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups. © 2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The possibility to access the absolute neutrino mass scale through the measurement of the wrong helicity contribution of charged leptons is investigated in pion decay. Through this method, one may have access to the same effective mass m 2β extractable from the tritium beta decay experiments for electron neutrinos as well as the analogous effective mass $(m 2nuμ}){eff} for muon neutrinos. In the channel π-→ ē-v̄, the relative probability of producing an antineutrino with left helicity is enhanced if compared with the naive expectation (m ν/2E ν) 2. The possibility to constrain new interactions in the context of two-Higgs-Doublet models is also investigated. © 2009 World Scientific Publishing Company.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A green ceramic tape micro heat exchanger was developed using LTCC technology. The device was designed by using a CAD software and 2D and 3D simulations using a CFD package (COMSOL Multiphysics) to evaluate the fluid behavior in the microchannels. The micro heat exchanger is composed of five thermal exchange plates in cross flow arrangement and two connecting plates; heat exchanger dimensions are 26 × 26 × 6 mm3. Preliminary tests were carried out to characterize the device both in atmospheric pressure and in vacuum. The same techniques used in vacuum technology were applied to check the rotameters and to prevent device leakages. Thermal performance of the micro heat exchanger was experimentally tested. © 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies carried out with glass electrode in anhydrous ethanol and ethanol-water solutions for measuring pH values have shown that this parameter depends on the solution composition, the contact time with the solution, the utilized temperature, and the type of electrolyte used. It was also observed that the glass electrode behavior in an acid medium differs from an alkaline medium. These studies provided correction factors for pH values from 2 to 12, allowing the realization of proper measurements of the hydrogen ionic activity in the ethanol-water and anhydrous ethanol solutions. However, these correction factors could not be applied to the fuel ethanol. Alternatively, a new method was developed for the correction of the pH values, which can be applied in hydrous and anhydrous fuel ethanol samples. Copyright © 2011 by ASTM International.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims to demonstrate an application of telemetry for monitoring process variables. The authors developed the prototype of a dedicated device capable of multiplexing, encoding and transmitting real-time data signals via amplitude-shift keying modulation to remotely located device(s). The prototype development is described in details, enabling the reproduction of the proposed telemetry system for a three-phase motor as well as for other devices. Furthermore, the proposed device has an easy implementation by using of accessible components and low cost, also presenting a tutorial and educational purpose. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of inclusive W and Z boson production cross sections in pp collisions at √s = 7 TeV are presented, based on 2.9 pb-1 of data recorded by the CMS detector at the LHC. The measurements, performed in the electron and muon decay channels, are combined to give σ(pp → WX) × B(W → l?) = 9.95 ± 0.07 (stat.) ± 0.28 (syst.) ± 1.09 (lumi.) nb and σ(pp → ZX) × B(Z → l +l-) = 0.931 ± 0.026 (stat.) ± 0.023 (syst.) ± 0.102 (lumi.) nb, where l stands for either e or μ. Theoretical predictions, calculated at the next-to-next-to-leading order in QCD using recent parton distribution functions, are in agreement with the measured cross sections. Ratios of cross sections, which incur an experimental systematic uncertainty of less than 4%, are also reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the hemodynamic and acid-base status of dogs subjected to acute normovolemic anemia. The dogs (n = 10) were evaluated 15 minutes and 24 hours after induction of anemia (hematocrit below 18) with blood withdrawal and simultaneously replacement of same volume of Ringer's lactate solution and hydroxyethyl starch-based solution in a 2:1 ratio. The cardiac output was measured by Doppler echocardiography and blood pressure by oscillometric device, and posteriorly hemodynamic parameters were calculated. The anemic groups had increase in cardiac index (P <.05) (3.82 ± 1.05 to 5.86 ± 1.49 and 5.81 ± 1.63 L/min m) and decreases (P <.05) in the indices of total peripheral resistance (6797.81 ± 3060.22 to 3220.14 ± 1275.02 and 3887.74 ± 1394.89 dinaseg/cm 5× m2) and oxygen delivery (7942.84 ± 3344.00 to 4021.68 ± 1627.00 and 4430.82 ± 1402.61 mL/min× m 2), respectively. There were no significant changes in pH, but PaO2 and SaO2 values were increased, and PaCO2 reduced in anemic dogs (P <.05). Therefore, acute normovolemic anemia can create significant hemodynamic changes and despite some hemogasometric changes, there were no changes in the acid-base status in dogs. Copyright © 2011 Tatiana Champion et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Studies with Doppler ultrassonography started at the end of the 90s for the determination of physiological and pathological alterations in the reproductive tract of the mare. Uterine alterations caused by inflammation, response from seminal plasma infusion, hormonal variations during estrous and diestrus, pregnancy and action of various vasoactive factors influence on the vascular perfusion detected by Doppler ultrasound. The development of efficient methods for uterine quality evaluation is of big importance for field equine reproduction veterinarians, once uterine environment is responsible for pregnancy maintenance. Review: Nowadays, the most used methods of uterine evaluation are the mode B ultrassonography, cytology, culture and biopsy. Hemodynamic evaluation of the uterus can be done by spectral data collected from large vessels, as A. uterine and its ramifications, or from subjective or objective evaluations from endometrium, miometrium and mesometrium attachment, which provide data referent to local and specific alterations of the evaluated area. Alterations in uterine vascular perfusion has been detected during estrous cycle, during pregnancy and in cases of infusion of inflammatory substances. These alterations happen because of vasoactive substances that act in the uterus during these events, however, most of these vasoactive substances are probably not even known. Also, important hemodynamic alterations in old mares, as an increase in vascular resistance, have been described. This increase might result from fibrosis of the uterus and in women it is considered to be a cause of infertility. In mares, periglandular fibrosis of the endometrium is considered to be the major diagnosable cause of embryonic and fetal loss in older mares. For the CL, ovarian artery of the mare supplies the ovary as well as the oviduct and therefore can be used for evaluation of these areas. The CL evaluation can also be done by the percentage of luteum area with colored signals as an indicator of the extent of blood flow. The percentage of the CL area with colored signals is determined subjectively by images observations in real time and/or by a freezing Power Doppler cross-section image with the maximum number of color pixels taped and the total number of color pixels is assessed by a computer analysis system. Therefore, a high correlation between plasmatic progesterone and CL vascularization also allows the CL evalution by this technique. In a first report, CL circulation reached its maximum on D5, the progesterone concentration in peripheral blood increased until D7 and in a posterior report, maximum perfusion was achieved two days after the maximum progesterone concentration (D8). Blood flow reduced between D10-D14 some days before the plasma progesterone decrease and, during the luteolytic period (D15-D17), the decline in CL blood-flow area was greater than blood flow decrease. Conclusion: Doppler ultrassonography add knowledge about uterine viability and CL functionality can be easily used by veterinarians in the field. It is a noninvasive method that provides real time results. However, because of the short time studies in this area have been done, many other answers still need to be found until normal and pathological patterns will be established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the combination of recent measurements of the helicity of the W boson from top quark decay by the CDF and D0 collaborations, based on data samples corresponding to integrated luminosities of 2.7-5.4fb -1 of pp̄ collisions collected during Run II of the Fermilab Tevatron collider. Combining measurements that simultaneously determine the fractions of W bosons with longitudinal (f 0) and right-handed (f +) helicities, we find f 0=0.722±0.081[±0.062(stat)±0.052(syst)] and f +=-0.033±0.046[±0.034(stat)±0.031(syst)]. Combining measurements where one of the helicity fractions is fixed to the value expected in the standard model, we find f 0=0.682±0. 057[±0.035(stat)±0.046(syst)] for fixed f + and f +=-0.015±0.035[±0.018(stat)±0.030(syst)] for fixed f 0. The results are consistent with standard model expectations. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the realization of a capacitive dilatometer, designed for high-resolution measurements of length changes of a material for temperatures 1.4K ≤ T ≤ 300K and hydrostatic pressure P ≤ 250MPa. Helium ( 4He) is used as a pressure-transmitting medium, ensuring hydrostatic-pressure conditions. Special emphasis has been given to guarantee, to a good approximation, constant-pressure conditions during temperature sweeps. The performance of the dilatometer is demonstrated by measurements of the coefficient of thermal expansion at pressures P ≃ 0.1MPa (ambient pressure) and 104MPa on a single crystal of azurite, Cu 3(CO 3) 2(OH) 2, a quasi-one-dimensional spin S = 1/2 Heisenberg antiferromagnet. The results indicate a strong effect of pressure on the magnetic interactions in this system. © 2012 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A major UK initiative, entitled 'Mapping the Underworld', is seeking to address the serious social, environmental and economic consequences arising from an inability to locate accurately and comprehensively the buried utility service infrastructure without resorting to extensive excavations. Mapping the Underworld aims to develop and prove the efficacy of a multi-sensor device for accurate remote buried utility service detection, location and, where possible, identification. One of the technologies to be incorporated in the device is low-frequency vibro-acoustics, and application of this technique for detecting buried infrastructure is currently being investigated. Here, the potential for making a number of simple point vibration measurements in order to detect shallow-buried objects, in particular plastic pipes, is explored. Point measurements can be made relatively quickly without the need for arrays of surface sensors, which can be expensive, time-consuming to deploy, and sometimes impractical in congested areas. At low frequencies, the ground behaves as a simple single-degree-of-freedom (mass-spring) system with a well-defined resonance, the frequency of which will depend on the density and elastic properties of the soil locally. This resonance will be altered by the presence of a buried object whose properties differ from the surrounding soil. It is this behavior which can be exploited in order to detect the presence of a buried object, provided it is buried at a sufficiently shallow depth. The theoretical background is described and preliminary measurements are made both on a dedicated buried pipe rig and on the ground over a domestic waste pipe. Preliminary findings suggest that, for shallow-buried pipes, a measurement of this kind could be a quick and useful adjunct to more conventional methods of buried pipe detection. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The top quark is the heaviest known elementary particle, with a mass about 40 times larger than the mass of its isospin partner, the bottom quark. It decays almost 100% of the time to a W boson and a bottom quark. Using top-antitop pairs at the Tevatron proton-antiproton collider, the CDF and D0 Collaborations have measured the top quark's mass in different final states for integrated luminosities of up to 5.8fb -1. This paper reports on a combination of these measurements that results in a more precise value of the mass than any individual decay channel can provide. It describes the treatment of the systematic uncertainties and their correlations. The mass value determined is 173.18±0.56(stat)±0.75(syst)GeV or 173.18±0.94GeV, which has a precision of ±0.54%, making this the most precise determination of the top-quark mass. © 2012 American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a practical experimentation for comparing reactive/non-active energy measures, considering three-phase four-wire non-sinusoidal and unbalanced circuits, involving five different commercial electronic meters. The experimentation set provides separately voltage and current generation, each one with any waveform involving up to fifty-first harmonic components, identically compared with acquisitions obtained from utility. The experimental accuracy is guaranteed by a class A power analyzer, according to IEC61000-4-30 standard. Some current and voltage combination profiles are presented and confronted with two different references of reactive/non-active calculation methodologies; instantaneous power theory and IEEE 1459-2010. The first methodology considers the instantaneous power theory, present into the advanced mathematical internal algorithm from WT3000 power analyzer, and the second methodology, accomplish with IEEE 1459-2010 standard, uses waveform voltage and current acquisition from WT3000 as input data for a virtual meter developed on Mathlab/Simulink software. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sugarcane is an important crop for the Brazilian economy and roughly 50% of its production is used to produce ethanol. However, the common practice of pre-harvest burning of sugarcane straw emits particulate material, greenhouse gases, and tropospheric ozone precursors to the atmosphere. Even with policies to eliminate the practice of pre-harvest sugarcane burning in the near future, there is still significant environmental damage. Thus, the generation of reliable inventories of emissions due to this activity is crucial in order to assess their environmental impact. Nevertheless, the official Brazilian emissions inventory does not presently include the contribution from pre-harvest sugarcane burning. In this context, this work aims to determine sugarcane straw burning emission factors for some trace gases and particulate material smaller than 2.5μm in the laboratory. Excess mixing ratios for CO2, CO, NOX, UHC (unburned hydrocarbons), and PM2.5 were measured, allowing the estimation of their respective emission factors. Average estimated values for emission factors (g kg-1 of burned dry biomass) were 1,303 ± 218 for CO2, 65 ± 14 for CO, 1.5 ± 0.4 for NOX, 16 ± 6 for UHC, and 2.6 ± 1.6 for PM2.5. These emission factors can be used to generate more realistic emission inventories and therefore improve the results of air quality models. © 2012 by the authors; licensee MDPI, Basel, Switzerland.