980 resultados para furnace


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to study the evolution of the corrosion rate of reinforcements embedded in mortar specimens that have been partly or fully replaced by the sand ladle furnace white slag. Prisms are manufactured mortar 6cm x 8cm x 2cm in which are embedded reinforcing steel bars of 6mm diameter B500SD. At the time of mixing were added varying amounts of chloride ion content by weight of cement (0%, 0.4%, 0.8%, 1.2%, 2%). The specimens were made totally or partially replacing the white slag, getting four different mixes depending on the degree of substitution. After curing the specimens for 28 days in moist chambers proceeded to dry up naturally. Here are gradually dampened by its conservation in a moist chamber, periodically measuring the corrosion rate of the bars using the technique of polarization curve. The results, in terms of corrosion current and corrosion potential, were compared with those obtained on standard samples, without replacement by slag aggregate. The analysis of results allows us to know, depending on the type of mortar used, the chloride threshold with the depassivation produced steel and the corrosion rates achieved in steels in the active state in terms of mortar moisture, obtained from qualitatively using gravimetric techniques. The results achieved to date support the conclusion that no significant differences in the behavior against corrosion induced by chloride ions, between the steel bars embedded in standard samples and the steel bars embedded in samples including with aggregates from slag. Both the chloride threshold resulting in the depassivation steel as the corrosion rate reached through the bars in an active state are very similar in both types of mortars when they have the same moisture content.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aluminium is added to decrease matrix chromium losses on 430 stainless steel sintered on nitrogen atmosphere. Three different ways were used to add a 3% (in weight) aluminium: as elemental powder, as prealloyed powder, and as intermetallic Fe-AI compound. After die pressing at densities between 6.1-6.5 g/cm3, samples were sintered on vacuum and on N2-5%H2 atmosphere in a dilatometric furnace. Therefore, dimensional change was recorded during sintering. Weight gain was obtained after nitrogen sintering on all materials due to nitrides formation. Sample expansion was obtained on all nitrogen sintered steels with Al additions. Microstructure showed a dispersion of aluminium nitrides when pre-alloyed powders are used. On the contrary, aluminium nitride areas can be found when aluminium is added as elemental powders or as Fe-AI intermetallics. Also nitrogen atmosphere leads to austenite formation and hence, on cooling, dilatometric results showed a dimensional change at austenitic-ferritic phase transformation temperature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Commercial aluminium foam filled structures and sandwich panels are available for structural applications. As alternative to these materials, small granular foamed pieces are proposed to fill structures as well as sandwich panels. On the present work, foam precursors are obtained by Powder Metallurgy (PM) route, using natural calcium carbonate as foaming agent instead of titanium hydride. Extruded precursor bars were cut into small pieces (around 4.5 mm long and 5mm in diameter). Foaming treatment was carried out on two different ways: electrical preheated furnace and by solar furnace. Foamed nodules presented a low cell size, density e.g. 0.67 g/cm3 to 0.88 g/cm3 and a height/diameter ratio between 0.72 and 0.84 as a function of precursor size. These properties depend on the foaming particle size, foaming cycle and precursor dimensions. Carbonate precursors are easily foamed by concentrated solar energy, due to the lower risk of cell collapse than with hydride precursors, resulting from cell stabilization by oxide skin formation into cells and a low degree of foamed nodules bonding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El hormigón armado es el material estructural más empleado en construcción, lo que exige un exhaustivo control tanto de los materiales que lo componen como de su ejecución, con el fin de garantizar la vida útil para la que ha sido proyectado. Uno de los principales problemas de la durabilidad del hormigón armado, es la corrosión de sus armaduras. Existen en la actualidad diferentes métodos que intentan detener el proceso de corrosión, entre ellos, los inhibidores superficiales de corrosión. El continuo incremento en la producción de acero desde el siglo XIX, ha producido un desequilibrio entre los productos fabricados en las industrias siderúrgicas y los residuos generados. Como consecuencia, toneladas de residuos son depositados en vertederos, provocando graves daños medioambientales con el paso del tiempo. El volumen de escorias producidas en la industria siderúrgica en España asciende a 2,55Mt al año, de ahí la importancia del reciclaje de estos productos y de su integración como materia prima en el proceso de fabricación de otros materiales. Partiendo de estas premisas, en el presente trabajo de investigación se ha estudiado el comportamiento a corrosión, de barras de acero de armar embebidas en probetas de mortero, en las que se ha sustituido parcialmente el árido y el cemento por escorias blancas de horno cuchara (LFS), mediante técnicas electroquímicas y gravimétricas. Para ello, se han fabricado probetas prismáticas de 6 x 8 x 2 cm3 con diferentes porcentajes de ión cloruro, introducidos en el momento del amasado, tanto en probetas patrón como en probetas con escorias LFS. El análisis de los resultados obtenidos permite concluir que las probetas patrón y las probetas con escorias LFS tienen comportamientos similares en presencia de cloruros por encima del 0,4% en peso de cemento y por tanto que la sustitución de escorias LFS por arena (25%) y cemento (30%) no afecta negativamente a la corrosión de las armaduras. Por tanto, el uso de escorias LFS en el proceso de fabricación de hormigón armado es una práctica que presenta ventajas competitivas respecto a las técnicas de construcción tradicionales, desde el punto de vista económico y medioambiental. En cuanto a los inhibidores superficiales de corrosión, no han resultado eficaces en probetas con escorias LFS, independientemente del porcentaje de ión cloruro, mientras que en probetas patrón han sido eficaces para porcentajes de ión cloruro igual o inferior al 0,8% en peso de cemento. ABSTRACT Reinforced concrete is the most widely used structural material. This implies that rigorous control must be applied in order to guarantee the life-span and performance of structures made using this composite material. One of the main problems regarding concrete durability is bar corrosion. At present, there are different methods adopted to stop the corrosion process, among them, surface corrosion inhibitors. The continuous growth in steel production since the 19th century has led to an imbalance between waste products generated in steel production processes and their subsequent use. As a consequence, mass dumping at waste disposal sites has been causing a significant environmental problem over the years. The amount of slag produced by the steel industry each year in Spain amounts to 2.55Mt, hence the importance of recycling by-products from steel production so they can be used as primary material in the manufacturing process of other materials. Starting from this working hypothesis, and using electrochemical and gravimetric techniques, this research work aims to analyse and study the corrosion behaviour of steel rebars embedded in mortar specimens, containing ladle furnace slag in partial substitution for aggregate and cement. Prisms were manufactured from 6 x 8 x 2 cm3 with different percentages of chloride ion introduced at the time of mixing, in standard specimens and specimens with LFS slag. Results from the analysis show that the standard specimens and those containing LFS slag display a similar behaviour in the presence of chlorides. Furthermore, when LFS slag is replaced by sand (25%) and cement (30%) corrosion of rebars is not negatively affected. Additionally, the use of LFS slag in the manufacture of reinforced structures is a practice that represents a competitive advantage over traditional construction techniques, from both an economic and environmental point of view Finally, as for surface corrosion inhibitors, they have not proved effective in specimens containing LFS slag, regardless of the percentage of the chloride ion, whereas in standard specimens they have been effective in chloride ion percentages not exceeding 0.8% (as to the cement amount).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study of sulfate attack in concrete is considered vital for the preservation of the structural integrity of constructions. Its aggressive behaviour causes degradation of the cement matrix which changes the initial properties of the material. In this article, the sulfate resistance of concrete is studied. To that goal, four different concrete mixes were made with sulphur resistant cement. The concretes were tested for compressive strength, transport capacity of sulfates and microstructural properties. An experimental program was proposed in which the concrete samples were submerged in sodium sulphate (Na2SO4) solution. The obtained results were compared with reference values of concretes cured in calcium hydroxide [Ca(OH)2]. According to the results the concrete with ground granulated blast-furnace slag presented the best behavior when exposed to sodium sulphate (Na2SO4) solution. El estudio del ataque de sulfatos en el hormigón se considera de gran importancia para la conservación de la integridad estructural de las construcciones. Su agresividad se basa en la degradación de la matriz cementicia modificando las características iniciales de diseño. En el presente trabajo se estudia la resistencia del hormigón al ataque de sulfatos provenientes de sulfato sódico (Na2SO4). Para llevar a cabo la investigación se diseñaron cuatro dosificaciones de hormigón empleando cementos sulforresistentes y adiciones minerales. Se llevó a cabo una propuesta experimental donde las muestras de hormigón se sumergieron en disolución de sulfato sódico (Na2SO4) de concentración 1M. Posteriormente se realizaron ensayos de resistencia mecánica, capacidad de transporte de sulfatos y propiedades microestructurales, a distintas edades. Los resultados obtenidos se compararon con valores de referencia de mezclas de hormigón curadas expuestas a hi-dróxido cálcico [Ca(OH)2]. De acuerdo a los resultados obtenidos, el hormigón con escoria de alto horno presentó las mejores características de durabilidad frente a sulfatos provenientes de sulfato sódico

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work studies the resistant of the concrete against magnesium sulfate (MgSO4) and compare the results with values obtained previously of the same concretes exposed to sodium sulfate (Na2SO4). Thus, it is possible analyze the influence of the cation type. To that end, four different concrete mixes were made with sulfur resistant cement and mineral admixtures (silica fume, fly ash and blast furnace slag). The concretes were submerged for different period in magnesium sulfate (MgSO4). After that, different tests were carried out to define mechanical and microstructural properties. The results obtained were compared with reference values of concretes cured in calcium hydroxide [Ca(OH)2]. According to the results, the concrete with blast furnace slag presented the best behavior front MgSO4, meanwhile the concretes with silica fume and fly ash were the most susceptible. The resistance of the concrete with blast furnace slag could be attributed to the characteristics of the hydrated silicates formed during the hydration time, which include aluminum in the chemical chain that hinder its chemical decomposition during the attack of magnesium. The magnesium sulfate solution was most aggressive than sodium sulfate solution. El presente trabajo estudia la resistencia de hormigones al ataque de sulfatos provenientes de sulfato magnésico (MgSO4) y compara estos valores con resultados previos de los mismos hormigones atacados con sulfato sódico (Na2SO4). De esta manera se estudia la interacción del catión que acompaña al ion sulfato durante su afectación a la matriz cementicia. Para lo anterior, se diseñaron cuatro dosificaciones empleando cementos sulforresistentes y adiciones minerales (humo de sílice, ceniza volante y escoria de alto horno). Los hormigones se sumergieron, por distintos periodos de tiempo, en disolución de sulfato magnésico (MgSO4) de concentración 1M, para después realizarles ensayos mecánicos y a nivel microestructural. Los valores obtenidos se compararon con los obtenidos en el hormigón de referencia curado en hidróxido cálcico. El hormigón con escoria de alto horno presentó el mejor comportamiento frente a MgSO4, siendo las mezclas de humo de sílice y ceniza volante las más susceptibles. La resistencia del hormigón con escoria se atribuye a las características de los silicatos hidratados formados durante la hidratación, los cuales incorporan aluminio en las cadenas impidiendo su descomposición ante un ataque por magnesio. El medio con sulfato magnésico mostro una mayor agresividad que el medio con sulfato sódico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El deterioro del hormigón debido a la presencia del ion cloruro es causa frecuente de problemas en estructuras localizadas en ambiente marino y alta montaña. Su principal efecto consiste en la despasivación del acero de refuerzo embebido en el hormigón y su consecuente inicio de la corrosión del mismo. El ingreso del ion cloruro al interior del hormigón, está condicionado por una serie de parámetros de origen medioambiental e intrínsecos del hormigón. En función de estos parámetros el ingreso de cloruros en el hormigón puede deberse principalmente a los siguientes mecanismos: difusión y succión capilar. El estudio y evaluación de la resistencia del hormigón frente a cloruros, se ha desarrollado principalmente en condiciones saturadas del hormigón. Lo que ha significado que parámetros de importancia no sean considerados. Debido a esto, distintos procesos que suceden en estructuras reales no han sido identificados y estudiados correctamente. En este trabajo, se diseñó un programa de investigación para evaluar los parámetros que influyen en el transporte cloruros en hormigones no saturados. Para esto se diseñaron tres dosificaciones diferentes de hormigón. En la primera se empleó únicamente cemento portland, para el resto se utilizaron adiciones minerales (humo de sílice y escoria de alto horno). El empleo de adiciones se debió a que tienen un papel importante en la durabilidad de hormigones frente a cloruros. Los hormigones fueron dosificados con una relación agua/material cementício de 0,40 para el hormigón elaborado únicamente con cemento portland y 0,45 para las mezclas con adiciones. Para evaluar las propiedades de los hormigones en estado fresco y endurecido se realizaron ensayos vigentes en las normativas. Con los resultados obtenidos se determinaron parámetros de resistencia mecánica, microestructurales, resistencia al transporte de cloruros e higroscópicos. Una vez caracterizados los hormigones, se diseñó una propuesta experimental para estudiar los principales parámetros presentes en estructuras reales con presencia de cloruros. Tanto la concentración de cloruro como las condiciones ambientales se han variado teniendo como referencia las situaciones reales que podrían producirse en ambientes de alta montaña en la zona centro de España. La propuesta experimental consistió en tratar de evaluar la capacidad de los hormigones al transporte de iones en ambientes de alta montaña con presencia de sales fundentes. Para esto se establecieron 5 fases experimentales donde los principales parámetros ambientales y la presencia de iones agresivos sufrieron variaciones. Al término de cada fase se obtuvieron perfiles de penetración de cloruros en los hormigones y se evaluó la influencia de los parámetros presentes en cada fase. Los resultados experimentales se implementaron en un modelo numérico basado en la teoría de elementos finitos, desarrollado por el grupo de investigación del Departamento de Materiales de Construcción. Para esto fue necesario realizar la calibración y validación del modelo numérico para cada hormigón. El calibrado del modelo precisa de datos químicos y microestructurales de cada hormigón, tales como: capacidad de combinación de cloruros y propiedades difusivas e higroscópicas. Para la validación del modelo numérico se realizaron simulaciones de la propuesta experimental. Los resultados obtenidos se compararon con los valores experimentales. Con el objeto de poder estudiar en mayor profundidad la influencia del grado de saturación del hormigón durante la difusión de cloruros, se llevó a cabo una campaña experimental que consideró distintos grados de saturación en los hormigones. Para esto se establecieron en los hormigones cuatro grados de saturación distintos (50%, 60%, 80% y 100%, aproximadamente), posteriormente se expusieron a cloruro de sodio finamente molido. Una vez transcurrido el tiempo necesario se obtuvieron experimentalmente los perfiles de penetración de cloruros para cada grado de saturación y se calcularon los coeficientes de difusión. Los datos obtenidos durante la campaña experimental han demostrado la influencia positiva que ejercen las adiciones en las mezclas de hormigón. Sus principales ventajas son el refinamiento de la red porosa y el aumento en la capacidad de combinación de cloruros, además de mejorar sus propiedades mecánicas. La porosidad total en las mezclas no presentó grandes cambios, sin embargo, el cambio en la distribución del tamaño de poros es importante en las muestras con adiciones. En especial las fabricadas con humo de sílice. Los coeficientes de difusión y migración de cloruros para las mezclas con adiciones disminuyeron significativamente, igual que los valores de resistividad eléctrica. En los ensayos de penetración del agua bajo presión, fueron las muestras con adiciones las que mostraron las menores penetraciones. Los resultados obtenidos al final de la propuesta experimental permitieron estudiar los distintos parámetros involucrados. Se observó claramente que el proceso de difusión provoca el mayor transporte de cloruros hacia el interior del hormigón. Así mismo se comprobó que el lavado superficial y el secado de las probetas, trasladan cloruros hacia las zonas externas del hormigón. El primero debido a una baja concentración de cloruros externa, mientras que el secado provoca el movimiento de la solución de poro hacia las zonas de secado depositando cloruros en ellas. Las medidas higroscópicas permitieron determinar la existencia de dos zonas distintas en el interior del hormigón. La primera se localizó en el rango de 0-10mm, aproximadamente, en ésta se puso de manifiesto una mayor sensibilidad a los cambios experimentados en el exterior de las probetas. La segunda zona se localizó a una profundidad mayor de 10mm, aproximadamente. Se observó claramente una baja influencia de los cambios externos, siendo la difusión de cloruros el principal mecanismo de transporte presente en ella. En cuanto al estudio de la influencia del grado de saturación en la difusión de cloruros, se observó claramente una marcada diferencia entre los coeficientes de difusión de cloruro obtenidos. Para grados de saturación mayores del 80% el mecanismo de penetración de cloruros por difusión existe de forma significativa. Mientras que para valores inferiores los resultados revelaron que las vías de acceso disminuyen (poros conectado con agua) considerablemente limitando en un alto grado la penetración del agresivo. Para grados de saturación inferiores del 50% los valores del coeficiente de difusión son despreciables. The deterioration of concrete due to chloride ions is a frequent problem identified in structures located in marine and high-mountain environments. After entering the outer layer of the concrete, the chlorides tend to penetrate until they reach and then depassivate the steel bars. Subsequently, this induces the deterioration process of the reinforced concrete. This chloride penetration depends on the environmental conditions and intrinsic parameters of the concrete. Several transport mechanisms, such as diffusion, capillary suction and permeability can be present into the concrete. While recent research into the study and evaluation of concretes with chloride presence has been carried out in saturated concrete, it has not considered certain parameters that can modify this condition. Consequently, at the time of writing several processes that take place in real structures have not been identified and studied. In this work a research programme is designed to evaluate the parameters that influence chloride transport into non-saturated concrete. For this, three concrete mixes were designed by using high-early-strength Portland cement and mineral admixtures (silica fume and blast-slag furnace). The water-cement ratio was 0.40 for the concrete made solely with Portland cement and 0.45 for the concretes that used mineral admixtures as a cement replacement. A set of experimental tests were performed to evaluate the concrete properties both in fresh and hardened state. In addition, an experimental simulation was carried out under laboratory conditions in which the main objective was to assess resistance of concrete to chloride penetration under high-mountain conditions with the presence of de-icing salts. The environmental conditions and surface chloride concentration of the concrete used during the experimental simulation were chosen by considering conditions found in the high-mountain environment in central Spain. For the experimental simulation five phases were designed by varying the environmental parameters and concrete surface concentration. At the end of each phase a chloride profile was obtained with the aim of assessing the influence of the parameters on chloride transport. The experimental results were then used to calibrate and validate a numerical model based on finite element theory developed by the research team from the Construction Materials Department in a previous work. In order to carry out model calibration chemical and microstructural data for the concretes was required, such as binding capacity and the diffusive and hygroscopic properties. The experimental results were compared with the numerical simulations and provided a good fit. With the objective of studying the influence of the degree of concrete saturation on chloride diffusion, an experimental programme was designed. This entailed four saturation degrees (50%, 60%, 80% and 100%) being established in several concrete samples. The samples were then exposed to ground sodium chloride. Once the time required was achieved, the chloride profiles and diffusion coefficients were obtained for each saturation degree. The results obtained from the experimental program revealed a positive influence of the mineral admixtures on the concretes. Their effects were reflected in the pore-network refinement and the increase of chloride binding capacity, together with the improvement of the mechanical properties of the concretes. Total porosity did not reveal any notable change, though the pore-size distribution showed a significant degree of change in the concretes with mineral admixtures, specifically the samples prepared through use of silica fume. The chloride diffusion and migration coefficient, as well as the electrical resistivity values, decreased significantly in the concretes with admixtures. In the water penetration under pressure test, the concretes with admixtures presented the lowest penetration depth. The results obtained in the experimental simulation allowed study of the main parameters involved during the chloride penetration processes in non-saturated concretes in the presence of chlorides. According to the results, the diffusion process was the transport mechanism that transferred the greatest amount of chlorides into the concrete samples. In addition, a chloride movement toward external zones of the concrete, caused by the washing of concrete surface and the drying processes, was identified. The washing occurred when the concrete surface came into contact with a low-chloride concentration solution which initiated the outward movement of chloride diffusion. The drying processes corresponded to a movement of pore solution launched by water evaporation from the outer layer. Furthermore, hygroscopic measurements made in the concrete allowed two areas with distinct behavioural patterns to be identified. The first one, located in the range of approximately 0-10mm, showed a greater degree of influence regarding the changes of the external conditions. The second, situated at depths greater than 10mm, displayed a low influence of external conditions. The main process in this area was diffusion. Study of the influence of the degree of concrete saturation on chloride diffusion showed a clear difference among the chloride diffusion coefficients obtained. For degrees of concrete saturation higher than 80%, chloride penetration by diffusion tends to be significant. However, in the case of extent of saturation of lower than 80%, the results revealed that the access zone through which chlorides can penetrate decreased considerably. For degrees of concrete saturation lower than 50%, the chloride diffusion coefficients were negligible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficiency of a Power Plant is affected by the distribution of the pulverized coal within the furnace. The coal, which is pulverized in the mills, is transported and distributed by the primary gas through the mill-ducts to the interior of the furnace. This is done with a double function: dry and enter the coal by different levels for optimizing the combustion in the sense that a complete combustion occurs with homogeneous heat fluxes to the walls. The mill-duct systems of a real Power Plant are very complex and they are not yet well understood. In particular, experimental data concerning the mass flows of coal to the different levels are very difficult to measure. CFD modeling can help to determine them. An Eulerian/Lagrangian approach is used due to the low solid–gas volume ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to contribute to a further understanding of the fundamentals of crystallographic slip and grain boundary sliding in the γ-TiAl Ti–45Al–2Nb–2Mn (at%)–0.8 vol%TiB2 intermetallic alloy, by means of in situ high-temperature tensile testing combined with electron backscatter diffraction (EBSD). Several microstructures, containing different fractions and sizes of lamellar colonies and equiaxed γ-grains, were fabricated by either centrifugal casting or powder metallurgy, followed by heat treatment at 1300 °C and furnace cooling. in situ tensile and tensile-creep experiments were performed in a scanning electron microscope (SEM) at temperatures ranging from 580 °C to 700 °C. EBSD was carried out in selected regions before and after straining. Our results suggest that, during constant strain rate tests, true twin γ/γ interfaces are the weakest barriers to dislocations and, thus, that the relevant length scale might be influenced by the distance between non-true twin boundaries. Under creep conditions both grain/colony boundary sliding (G/CBS) and crystallographic slip are observed to contribute to deformation. The incidence of boundary sliding is particularly high in γ grains of duplex microstructures. The slip activity during creep deformation in different microstructures was evaluated by trace analysis. Special emphasis was placed in distinguishing the compliance of different slip events with the Schmid law with respect to the applied stress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The phosphosilicate glass (PSG), fabricated by tube furnace diffusion using a POCl3 source, is widely used as a dopant source in the manufacturing of crystalline silicon solar cells. Although it has been a widely addressed research topic for a long time, there is still lack of a comprehensive understanding of aspects such as the growth, the chemical composition, possible phosphorus depletion, the resulting in-diffused phosphorus profiles, the gettering behavior in silicon, and finally the metal-contact formation. This paper addresses these different aspects simultaneously to further optimize process conditions for photovoltaic applications. To do so, a wide range of experimental data is used and combined with device and process simulations, leading to a more comprehensive interpretation. The results show that slight changes in the PSG process conditions can produce high-quality emitters. It is predicted that PSG processes at 860 °C for 60 min in combination with an etch-back and laser doping from PSG layer results in high-quality emitters with a peak dopant density Npeak = 8.0 × 1018 cm−3 and a junction depth dj = 0.4 μm, resulting in a sheet resistivityρsh = 380 Ω/sq and a saturation current-density J0 below 10 fA/cm2. With these properties, the POCl3 process can compete with ion implantation or doped oxide approaches.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the last decades, an increasing interest in the research field of wide bandgap semiconductors was observed, mostly due to the progressive approaching of silicon-based devices to their theoretical limits. 4H-SiC is an example among these, and is a mature compound for applications. The main advantages offered 4H-SiC in comparison with silicon are an higher breakdown field, an higher thermal conductivity, a higher operating temperature, very high hardness and melting point, biocompatibility, but also low switching losses in high frequencies applications and lower on-resistances in unipolar devices. Then, 4H-SiC power devices offer great performance improvement; moreover, they can work in hostile environments where silicon power devices cannot function. Ion implantation technology is a key process in the fabrication of almost all kinds of SiC devices, owing to the advantage of a spatially selective doping. This work is dedicated to the electrical investigation of several differently-processed 4H-SiC ion- implanted samples, mainly through Hall effect and space charge spectroscopy experiments. It was also developed the automatic control (Labview) of several experiments. In the work, the effectiveness of high temperature post-implant thermal treatments (up to 2000°C) were studied and compared considering: (i) different methods, (ii) different temperatures and (iii) different duration of the annealing process. Preliminary p + /n and Schottky junctions were also investigated as simple test devices. 1) Heavy doping by ion implantation of single off-axis 4H-SiC layers The electrical investigation is one of the most important characterization of ion-implanted samples, which must be submitted to mandatory post-implant thermal treatment in order to both (i) recover the lattice after ion bombardment, and (ii) address the implanted impurities into lattice sites so that they can effectively act as dopants. Electrical investigation can give fundamental information on the efficiency of the electrical impurity activation. To understand the results of the research it should be noted that: (a) To realize good ohmic contacts it is necessary to obtain spatially defined highly doped regions, which must have conductivity as low as possible. (b) It has been shown that the electrical activation efficiency and the electrical conductivity increase with the annealing temperature increasing. (c) To maximize the layer conductivity, temperatures around 1700°C are generally used and implantation density high till to 10 21 cm -3 . In this work, an original approach, different from (c), is explored by the using very high annealing temperature, around 2000°C, on samples of Al + -implant concentration of the order of 10 20 cm -3 . Several Al + -implanted 4H-SiC samples, resulting of p-type conductivity, were investigated, with a nominal density varying in the range of about 1-5∙10 20 cm -3 and subjected to two different high temperature thermal treatments. One annealing method uses a radiofrequency heated furnace till to 1950°C (Conventional Annealing, CA), the other exploits a microwave field, providing a fast heating rate up to 2000°C (Micro-Wave Annealing, MWA). In this contest, mainly ion implanted p-type samples were investigated, both off-axis and on-axis <0001> semi-insulating 4H-SiC. Concerning p-type off-axis samples, a high electrical activation of implanted Al (50-70%) and a compensation ratio below 10% were estimated. In the work, the main sample processing parameters have been varied, as the implant temperature, CA annealing duration, and heating/cooling rates, and the best values assessed. MWA method leads to higher hole density and lower mobility than CA in equivalent ion implanted layers, resulting in lower resistivity, probably related to the 50°C higher annealing temperature. An optimal duration of the CA treatment was estimated in about 12-13 minutes. A RT resistivity on the lowest reported in literature for this kind of samples, has been obtained. 2) Low resistivity data: variable range hopping Notwithstanding the heavy p-type doping levels, the carrier density remained less than the critical one required for a semiconductor to metal transition. However, the high carrier densities obtained was enough to trigger a low temperature impurity band (IB) conduction. In the heaviest doped samples, such a conduction mechanism persists till to RT, without significantly prejudice the mobility values. This feature can have an interesting technological fall, because it guarantee a nearly temperature- independent carrier density, it being not affected by freeze-out effects. The usual transport mechanism occurring in the IB conduction is the nearest neighbor hopping: such a regime is effectively consistent with the resistivity temperature behavior of the lowest doped samples. In the heavier doped samples, however, a trend of the resistivity data compatible with a variable range hopping (VRH) conduction has been pointed out, here highlighted for the first time in p-type 4H-SiC. Even more: in the heaviest doped samples, and in particular, in those annealed by MWA, the temperature dependence of the resistivity data is consistent with a reduced dimensionality (2D) of the VRH conduction. In these samples, TEM investigation pointed out faulted dislocation loops in the basal plane, whose average spacing along the c-axis is comparable with the optimal length of the hops in the VRH transport. This result suggested the assignment of such a peculiar behavior to a kind of spatial confinement into a plane of the carrier hops. 3) Test device the p + -n junction In the last part of the work, the electrical properties of 4H-SiC diodes were also studied. In this case, a heavy Al + ion implantation was realized on n-type epilayers, according to the technological process applied for final devices. Good rectification properties was shown from these preliminary devices in their current-voltage characteristics. Admittance spectroscopy and deep level transient spectroscopy measurements showed the presence of electrically active defects other than the dopants ones, induced in the active region of the diodes by ion implantation. A critical comparison with the literature of these defects was performed. Preliminary to such an investigation, it was assessed the experimental set up for the admittance spectroscopy and current-voltage investigation and the automatic control of these measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A unidade de coqueamento retardado é um processo térmico de conversão, utilizado pelas refinarias, para converter cargas residuais em produtos de baixo peso molecular e com alto valor agregado (gases, nafta e gasóleo) e coque verde de petróleo. Um pequeno aumento no rendimento líquido da unidade de coqueamento retardado proporciona benefícios económicos consideráveis, especialmente no destilado líquido. A concorrência no mercado, as restrições sobre as especificações do produto e gargalos operacionais exigem um melhor planejamento da produção. Portanto, o desenvolvimento de novas estratégias e modelos matemáticos, focados em melhores condições de operação do processo industrial e formulações de produtos, é essencial para alcançar melhores rendimentos e um acompanhamento mais preciso da qualidade do produto. Este trabalho tem como objetivo o desenvolvimento de modelo matemático do conjunto forno-reator do processo de coqueamento, a partir de informações obtidas em uma planta industrial. O modelo proposto é baseado na caracterização da carga e dos produtos em pseudocomponentes, modelos cinéticos de grupos e condições de equilíbrio liquido-vapor. Além disso, são discutidos os principais desafios para o desenvolver o modelo matemático do forno e do reator, bem como a caracterização rigorosa do resíduo de vácuo e dos produtos para determinar os parâmetros que afetam a morfologia do coque e a zona de reação no interior do reator de coque.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been analyzed samples of portland cement (PC) with and without admixtures, samples of calcium aluminate cement (CAC) with different content of Al2O3 and specimens of concrete made with PC and CAC using High Resolution Gamma Spectrometry. The activity concentration index (I) is much less than 0.5 mSv y-1 for all the concrete specimens according to the Radiation protection document 112 of the European Commission. The PC without admixtures (CEM I 52,5 R) and the PC with addition of limestone (CEM II/BL 32,5 N) also have an I value much lower than 0.5 and the PC with the addition of fly ash and blast furnace slag (CEM IV/B (V) 32,5 N and III/A 42.5 N/SR) have an I value close to 0.6. The I value of the CAC used in the manufacture of structural precast concrete is of the order of 1 mSv y-1. Some of the CAC used in refractory concrete reaches a value close to 2 mSv y-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En este trabajo se ha estudiado la evolución de la microestructura, propiedades de durabilidad y resistencias mecánicas de morteros preparados con cementos comerciales, que contienen ceniza volante (entre un 21% y un 35%) y escoria de alto horno (entre un 66% y un 80%), expuestos a tres ambientes, un ambiente óptimo de laboratorio, y dos ambientes representativos del clima Atlántico y Mediterráneo respectivamente. Como referencia de comportamiento, también se ensayaron morteros de cemento Portland. La microestructura se caracterizó mediante porosimetría de intrusión de mercurio. En lo referente a la durabilidad, se estudiaron los coeficientes de absorción capilar y de migración de cloruros en estado no estacionario. También se determinó la resistencia a compresión de los morteros. Los ensayos se realizaron a 7, 28 y 90 días. La principal conclusión alcanzada es que los cementos con cenizas y escorias expuestos a condiciones ambientales representativas de los climas Atlántico y Mediterráneo, pueden desarrollar unas propiedades en servicio adecuadas al cabo de tres meses.