918 resultados para force-trauma


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The molecular structures of NbOBr3, NbSCl3, and NbSBr3 have been determined by gas-phase electron diffraction (GED) at nozzle-tip temperatures of 250 degreesC, taking into account the possible presence of NbOCl3 as a contaminant in the NbSCl3 sample and NbOBr3 in the NbSBr3 sample. The experimental data are consistent with trigonal-pyramidal molecules having C-3v symmetry. Infrared spectra of molecules trapped in argon or nitrogen matrices were recorded and exhibit the characteristic fundamental stretching modes for C-3v species. Well resolved isotopic fine structure (Cl-35 and Cl-37) was observed for NbSCl3, and for NbOCl3 which occurred as an impurity in the NbSCl3 spectra. Quantum mechanical calculations of the structures and vibrational frequencies of the four YNbX3 molecules (Y = O, S; X = Cl, Br) were carried out at several levels of theory, most importantly B3LYP DFT with either the Stuttgart RSC ECP or Hay-Wadt (n + 1) ECP VDZ basis set for Nb and the 6-311 G* basis set for the nonmetal atoms. Theoretical values for the bond lengths are 0.01-0.04 Angstrom longer than the experimental ones of type r(a), in accord with general experience, but the bond angles with theoretical minus experimental differences of only 1.0-1.5degrees are notably accurate. Symmetrized force fields were also calculated. The experimental bond lengths (r(g)/Angstrom) and angles (angle(alpha)/deg) with estimated 2sigma uncertainties from GED are as follows. NbOBr3: r(Nb=O) = 1.694(7), r(Nb-Br) = 2.429(2), angle(O=Nb-Br) = 107.3(5), angle(Br-Nb-Br) = 111.5(5). NbSBr3: r(Nb=S) = 2.134(10), r(Nb-Br) = 2.408(4), angle(S=Nb-Br) = 106.6(7), angle(Br-Nb-Br) = 112.2(6). NbSCl3: Nb=S) = 2.120(10), r(Nb-Cl) = 2.271(6), angle(S=Nb-Cl) = 107.8(12), angle(Cl-Nb-Cl) = 111.1(11).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Inadvertent drilling on the ossicular chain is one of the causes of sensorineural hearing loss (HL) that may follow tympanomastoid surgery. A high-frequency HL is most frequently observed. It is speculated that the HL is a result of vibration of the ossicular chain resembling acoustic noise trauma. It is generally considered that using a large cutting burr is more likely to cause damage than a small diamond burr. Aim: The aim was to investigate the equivalent noise level and its frequency characteristics generated by drilling onto the short process of the incus in fresh human temporal bones. Methods and Materials: Five fresh cadaveric temporal bones were used. Stapes displacement was measured using laser Doppler vibrometry during short drilling episodes. Diamond. and cutting burrs of different diameters were used. The effect of the drilling on stapes footplate displacement was compared with that generated by an acoustic signal. The equivalent noise level (dB sound pressure level equivalent [SPL eq]) was thus calculated. Results: The equivalent noise levels generated ranged from 93 to 125 dB SPL eq. For a 1-mm cutting burr, the highest equivalent noise level was 108 dB SPL eq, whereas a 2.3-mm cutting burr produced a maximal level of 125 dB SPL eq. Diamond burrs generated less noise than their cutting counterparts, with a 2.3-mm diamond burr producing a highest equivalent noise level of 102, dB SPL eq. The energy of the noise increased at the higher end of the frequency spectrum, with a 2.3-mm cutting burr producing a noise level of 105 dB SPL eq at 1 kHz and 125 dB SPL eq at 8 kHz. In contrast, the same sized diamond burr produced 96 dB SPL eq at 1 kHz and 99 dB at 8 kHz. Conclusion:This study suggests that drilling on the ossicular chain can produce vibratory force that is analogous with noise levels known to produce acoustic trauma. For the same type of burr, the larger the diameter, the greater the vibratory force, and for the same size of burr, the cutting burr creates more vibratory force than the diamond burr. The cutting burr produces greater high-frequency than lower-frequency vibratory energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate cortisol suppression following 0.5 mg of dexamethasone (DEX) in trauma survivors (N = 52),with posttraumatic stress disorder (PTSD), major depressive disorder (MDD), both, or neither disorder, and in subjects never exposed to trauma (N = 10), in order to examine interactions between diagnosis and trauma history on cortisol negative feedback inhibition. Method: Lifetime trauma exposure and psychiatric diagnoses were assessed and blood samples were obtained at 8:00 a.m. for the determination of baseline cortisol. Participants ingested 0.5 mg of DEX at 11:00 p.m. and blood samples for determination of cortisol and DEX were obtained at 8:00 a.m. the following day. Results: PTSD was associated with enhanced cortisol suppression in response to DEX Among trauma survivors, the presence of a traumatic event prior to the "focal" trauma had a substantial impact on cortisol suppression in subjects with MDD. Such subjects were more likely to show cortisol alterations similar to those associated with PTSD, whereas subjects with MDD with no prior trauma were more likely to show alterations in the opposite direction, i.e. relative non-suppression. Conclusions: Cortisol hypersuppression in PTSD appears not to be dependent on the presence of traumatic events prior to the focal trauma. However, prior trauma exposure may affect cortisol suppression in MDD. This finding may have implications for understanding why only some depressed patients show non-suppression on the DST. Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intrusive reexperiencing in posttraumatic stress disorder (PTSD) has been linked to perceptual priming for trauma-related material. A prospective longitudinal study (N = 69) investigated perceptual priming for trauma-related, general threat, and neutral words in assault survivors with and without PTSD, using a new version of the word-stem completion task. Survivors with PTSD showed enhanced priming for trauma-related words. Furthermore, priming for trauma-related words measured soon after the trauma was associated with subsequent PTSD severity at 3 6, and 9 months. The enhanced priming effect was specific to trauma-related words. Enhanced perceptual priming for traumatic material appears to be one of the cognitive processes operating in PTSD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study extends previous investigation of schizotypy as a vulnerability factor for trauma-related intrusions through the use of a clinical sample. Fifty people seeking psychological interventions after experiencing a distressing or traumatic event completed measures of positive schizotypy, posttraumatic stress disorder symptomatology, peritraumatic dissociation, and mood. Individuals scoring high in positive schizotypy were vulnerable to experiencing more frequent trauma-related intrusions along with wider posttraumatic stress disorder symptomatology, including hypervigilance, avoidance, and low mood. Results are discussed within a theoretical context, suggesting that certain information processing styles associated with high schizotype individuals may account for a vulnerability to trauma-related intrusions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors investigated whether heart rate (HR) responses to voluntary recall of trauma memories (a) are related to posttraumatic stress disorder (PTSD), and (b) predict recovery 6 months later. Sixty-two assault survivors completed a recall task modeled on imaginal reliving in the initial weeks postassault. Possible cognitive modulators of HR responsivity were assessed; dissociation, rumination, trauma memory disorganization. Individuals with PTSD showed a reduced HR response to reliving compared to those without PTSD, but reported greater distress. Notably, higher HR response but not self-reported distress during reliving predicted greater symptom reduction at follow-up in participants with PTSD. Engagement in rumination was the only cognitive factor that predicted lower HR response. The data are in contrast to studies using trauma reminders to trigger memories, which have found greater physiological reactivity in PTSD. The authors' observations are consistent with models of PTSD that highlight differences between cued or stimulus-driven retrieval and intentional trauma recall, and with E B. Foa and M.J. Kozak (1986) hypothesis that full activation of trauma memories facilitates emotional processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two studies of assault victims examined the roles of (a) disorganized trauma memories in the development of posttraumatic stress disorder (PTSD), (b) peritraumatic cognitive processing in the development of problematic memories and PTSD, and (c) ongoing dissociation and negative appraisals of memories in maintaining symptomatology. In the cross-sectional study (n = 81), comparisons of current, past, and no-PTSD groups suggested that peritraumatic cognitive processing is related to the development of disorganized memories and PTSD. Ongoing dissociation and negative appraisals served to maintain PTSD symptoms. The prospective study (n = 73) replicated these findings longitudinally. Cognitive and memory assessments completed within 12-weeks postassault predicted 6-month symptoms. Assault severity measures explained 22% of symptom variance; measures of cognitive processing, memory disorganization, and appraisals increased prediction accuracy to 71%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous work has presented the friction cone algorithm, a generalised method to resolve forces on a simulated haptic object when two or more fingers are in contact. Two extensions to the friction cone algorithm are presented: force shading and bump mapping. Force shading removes the discontinuities that are present when transitioning from one face to the next, whilst bump mapping provides a mechanism for rendering haptic textures on polygonal surfaces. Both these extensions can be combined whilst still maintaining the friction cone algorithm's intrinsic ability to simulate arbitrarily complex friction models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interface between humans and technology is a rapidly changing field. In particular as technological methods have improved dramatically so interaction has become possible that could only be speculated about even a decade earlier. This interaction can though take on a wide range of forms. Indeed standard buttons and dials with televisual feedback are perhaps a common example. But now virtual reality systems, wearable computers and most of all, implant technology are throwing up a completely new concept, namely a symbiosis of human and machine. No longer is it sensible simply to consider how a human interacts with a machine, but rather how the human-machine symbiotic combination interacts with the outside world. In this paper we take a look at some of the recent approaches, putting implant technology in context. We also consider some specific practical examples which may well alter the way we look at this symbiosis in the future. The main area of interest as far as symbiotic studies are concerned is clearly the use of implant technology, particularly where a connection is made between technology and the human brain and/or nervous system. Often pilot tests and experimentation has been carried out apriori to investigate the eventual possibilities before human subjects are themselves involved. Some of the more pertinent animal studies are discussed briefly here. The paper however concentrates on human experimentation, in particular that carried out by the authors themselves, firstly to indicate what possibilities exist as of now with available technology, but perhaps more importantly to also show what might be possible with such technology in the future and how this may well have extensive social effects. The driving force behind the integration of technology with humans on a neural level has historically been to restore lost functionality in individuals who have suffered neurological trauma such as spinal cord damage, or who suffer from a debilitating disease such as lateral amyotrophic sclerosis. Very few would argue against the development of implants to enable such people to control their environment, or some aspect of their own body functions. Indeed this technology in the short term has applications for amelioration of symptoms for the physically impaired, such as alternative senses being bestowed on a blind or deaf individual. However the issue becomes distinctly more complex when it is proposed that such technology be used on those with no medical need, but instead who wish to enhance and augment their own bodies, particularly in terms of their mental attributes. These issues are discussed here in the light of practical experimental test results and their ethical consequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss a novel approach to the development of an ultrasonic optical force-feedback measurement microphone suitable for observing biophotonic related photoacoustic and photothermal phenomena at high modulation frequencies and spatial resolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current limitations in piezoelectric and electrostatic transducers are discussed. A force-feedback electrostatic transducer capable of operating at bandwidths up to 20 kHz is described. Advantages of the proposed design are a linearised operation which simplifies the feedback control aspects and robustness of the performance characteristics to environmental perturbations. Applications in nanotechnology, optical sciences and acoustics are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a study investigating how the performance of motion-impaired computer users in point and click tasks varies with target distance (A), target width (W), and force-feedback gravity well width (GWW). Six motion-impaired users performed point and click tasks across a range of values for A, W, and GWW. Times were observed to increase with A, and to decrease with W. Times also improved with GWW, and, with the addition of a gravity well, a greater improvement was observed for smaller targets than for bigger ones. It was found that Fitts Law gave a good description of behaviour for each value of GWW, and that gravity wells reduced the effect of task difficulty on performance. A model based on Fitts Law is proposed, which incorporates the effect of GWW on movement time. The model accounts for 88.8% of the variance in the observed data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asymmetric poly(styrene-b-methyl methacrylate) (PS-b-PMMA) diblock copolymers of molecular weight M-n = 29,700g mol(-1) (M-PS = 9300 g mol(-1) M-PMMA = 20,100 g mol(-1), PD = 1.15, chi(PS) = 0.323, chi(PMMA) = 0.677) and M-n = 63,900 g mol(-1) (M-PS = 50,500 g mol(-1), M-PMMA = 13,400 g mol(-1), PD = 1.18, chi(PS) = 0.790, chi(PMMA) = 0.210) were prepared via reversible addition-fragmentation chain transfer (RAFT) polymerization. Atomic force microscopy (AFM) was used to investigate the surface structure of thin films, prepared by spin-coating the diblock copolymers on a silicon substrate. We show that the nanostructure of the diblock copolymer depends on the molecular weight and volume fraction of the diblock copolymers. We observed a perpendicular lamellar structure for the high molar mass sample and a hexagonal-packed cylindrical patterning for the lower molar mass one. Small-angle X-ray scattering investigation of these samples without annealing did not reveal any ordered structure. Annealing of PS-b-PMMA samples at 160 degrees C for 24 h led to a change in surface structure.