982 resultados para fluorescence probe technique


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The in situ saphenous vein bypass has been introduced in our department since 1989. A total of 26 bypasses in 22 patients have been followed prospectively. Indications for revascularisation have been severe arterial insufficiency in 73% of the cases (stage III or IV). With the exception of one postoperative death (myocardial infarction), all the patients have recovered uneventfully, with a regression to stage I. No amputation has been necessary. Morbidity has been 30%, with mainly minor local complications. The primary patency rate is 83% at one year and 78% after 2 and 3 years, whereas the secondary patency rate is 91% at one year, and remains constant thereafter up to 3 years. Considering our results and those from the literature, we believe that the in situ technique is very valuable, especially for below-knee vascular reconstruction. Technical difficulties of the method are analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complexing capacity of synthetic (0.011 M tartrate in 13.5% ethanol) and real wine (Raimat Abadia) in titrations with added total Zn concentrations up to 0.03 M has been determined following the free Zn concentrations with AGNES (absence of gradients and Nernstian equilibrium stripping) technique. A correction to find the preconcentration factor or gain (Y1) really applied at each one of the ionic strengths reached due to Zn additions along the titration has been applied. The standard implementation of AGNES to real wine led to the observation of two anomalous behaviors: (a) an increasingly negative current in the deposition stage (labeled as “HER” effect) and (b) a minimum in the currents of the stripping stage plot (labeled as the “dip” effect). A practical strategy to apply AGNES avoiding the dip effect has been developed to quantify properly free Zn concentrations. The van den Berg–Ružic–Lee linearization method (assuming the existence of just 1:1 complexes) has been adapted to consider the dilution effect and the ionic strength changes. Aggregated stability constants and total ligand concentrations have been calculated from synthetic and wine titration data. The found complexing capacity in the studied wine (cT,L = 0.0179 ± 0.0007 M) indicates the contribution of ligands other than tartrate (which is confirmed to be the main one).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of the shape of excitation-emission matrices (EEMs) is a relevant tool for exploring the origin, transport and fate of dissolved organic matter (DOM) in aquatic ecosystems. Within this context, the decomposition of EEMs is acquiring a notable relevance. A simple mathematical algorithm that automatically deconvolves individual EEMs is described, creating new possibilities for the comparison of DOM fluorescence properties and EEMs that are very different from each other. A mixture model approach is adopted to decompose complex surfaces into sub-peaks. The laplacian operator and the Nelder-Mead optimisation algorithm are implemented to individuate and automatically locate potential peaks in the EEM landscape. The EEMs of a simple artificial mixture of fluorophores and DOM samples collected in a Mediterranean river are used to describe the model application and to illustrate a strategy that optimises the search for the optimal output.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Source/Description: pKM.19 is a 1.0 kb EcoRI genomic fragment in pUC13 (ref. 1,2). pPl was isolated independently but contains the same fragment as pKM.19 (ref. 3)...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrically driven Er3+ doped Si slot waveguides emitting at 1530 nm are demonstrated. Two different Er3+ doped active layers were fabricated in the slot region: a pure SiO2 and a Si-rich oxide. Pulsed polarization driving of the waveguides was used to characterize the time response of the electroluminescence (EL) and of the signal probe transmission in 1 mm long waveguides. Injected carrier absorption losses modulate the EL signal and, since the carrier lifetime is much smaller than that of Er3+ ions, a sharp EL peak was observed when the polarization was switched off. A time-resolved electrical pump & probe measurement in combination with lock-in amplifier techniques allowed to quantify the injected carrier absorption losses. We found an extinction ratio of 6 dB, passive propagation losses of about 4 dB/mm, and a spectral bandwidth > 25 nm at an effective d.c. power consumption of 120 μW. All these performances suggest the usage of these devices as electro-optical modulators.