989 resultados para fixed odds betting machines


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of full-arch implant-supported screw-retained computer-aided designed and computer-aided manufactured (CAD/CAM) titanium-fixed dental prostheses (FDP) before and after veneering. The null-hypothesis was that there is no difference in vertical microgap values between pure titanium frameworks and FDPs after porcelain firing. MATERIALS AND METHODS Five CAD/CAM titanium grade IV frameworks for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI tooth positions 15, 13, 11, 21, 23, 25) were fabricated after digitizing the implant platforms and the cuspid-supporting framework resin pattern with a laser scanner (CARES(®) Scan CS2; Institut Straumann AG, Basel, Switzerland). A bonder, an opaquer, three layers of porcelain, and one layer of glaze were applied (Vita Titankeramik) and fired according to the manufacturer's preheating and fire cycle instructions at 400-800°C. The one-screw test (implant 25 screw-retained) was applied before and after veneering of the FDPs to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from interproximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS All vertical microgaps were clinically acceptable with values <90 μm. No statistically significant pairwise difference (P = 0.98) was observed between the relative effects of vertical microgap of unveneered (median 19 μm; 95% CI 13-35 μm) and veneered FDPs (20 μm; 13-31 μm), providing support for the null-hypothesis. Analysis within the groups showed significantly different values between the five implants of the FDPs before (P = 0.044) and after veneering (P = 0.020), while a monotonous trend of increasing values from implant 23 (closest position to screw-retained implant 25) to 15 (most distant implant) could not be observed (P = 0.169, P = 0.270). CONCLUSIONS Full-arch CAD/CAM titanium screw-retained frameworks have a high accuracy. Porcelain firing procedure had no impact on the precision of fit of the final FDPs. All implant microgap measurements of each FDP showed clinically acceptable vertical misfit values before and after veneering. Thus, the results do not only show accurate performance of the milling and firing but show also a reproducible scanning and designing process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By means of fixed-links modeling, the present study identified different processes of visual short-term memory (VSTM) functioning and investigated how these processes are related to intelligence. We conducted an experiment where the participants were presented with a color change detection task. Task complexity was manipulated through varying the number of presented stimuli (set size). We collected hit rate and reaction time (RT) as indicators for the amount of information retained in VSTM and speed of VSTM scanning, respectively. Due to the impurity of these measures, however, the variability in hit rate and RT was assumed to consist not only of genuine variance due to individual differences in VSTM retention and VSTM scanning but also of other, non-experimental portions of variance. Therefore, we identified two qualitatively different types of components for both hit rate and RT: (1) non-experimental components representing processes that remained constant irrespective of set size and (2) experimental components reflecting processes that increased as a function of set size. For RT, intelligence was negatively associated with the non-experimental components, but was unrelated to the experimental components assumed to represent variability in VSTM scanning speed. This finding indicates that individual differences in basic processing speed, rather than in speed of VSTM scanning, differentiates between high- and low-intelligent individuals. For hit rate, the experimental component constituting individual differences in VSTM retention was positively related to intelligence. The non-experimental components of hit rate, representing variability in basal processes, however, were not associated with intelligence. By decomposing VSTM functioning into non-experimental and experimental components, significant associations with intelligence were revealed that otherwise might have been obscured.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The attentional blink phenomenon (AB) represents impaired identification of the second of two targets presented in rapid succession within a stream of stimuli. Despite the well-known association between attentional processes and psychometric intelligence (PI), evidence for a relationship between AB and PI is highly inconsistent. Theory and empirical findings suggest AB to be multifaceted. Hence, relations between AB and PI may be blurred when AB is measured as a single process. Furthermore, different aspects of PI might be differentially related to AB. The present study explored the relationship between processes underlying AB and general PI as well as specific aspects of PI (Reasoning, Speed, Memory, and Creativity) in 201 female students. Fixed-links modeling revealed three processes underlying AB: (1) a U-shaped process positively related to Speed and negatively related to Memory but unrelated to Reasoning, Creativity, and general PI, (2) an increasing process positively related to Reasoning, Speed, Memory, and general PI but not to Creativity, and (3) a decreasing process positively related to general PI and Memory but not to other aspects of PI. Our findings demonstrate that dissociating processes underlying AB and considering specific aspects of PI is required to understand the relationship between AB and PI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When observers are presented with two visual targets appearing in the same position in close temporal proximity, a marked reduction in detection performance of the second target has often been reported, the so-called attentional blink phenomenon. Several studies found a similar decrement of P300 amplitudes during the attentional blink period as observed with detection performances of the second target. However, whether the parallel courses of second target performances and corresponding P300 amplitudes resulted from the same underlying mechanisms remained unclear. The aim of our study was therefore to investigate whether the mechanisms underlying the AB can be assessed by fixed-links modeling and whether this kind of assessment would reveal the same or at least related processes in the behavioral and electrophysiological data. On both levels of observation three highly similar processes could be identified: an increasing, a decreasing and a u-shaped trend. Corresponding processes from the behavioral and electrophysiological data were substantially correlated, with the two u-shaped trends showing the strongest association with each other. Our results provide evidence for the assumption that the same mechanisms underlie attentional blink task performance at the electrophysiological and behavioral levels as assessed by fixed-links models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the 2-d O(3) model with a q-term as a toy model for slowly walking 4-d non-Abelian gauge theories. Using the very efficient meron-cluster algorithm, an accurate investigation of the scale dependence of the renormalized coupling is carried out for different values of the vacuum angle q. Approaching q = p, the infrared dynamics of the 2-d O(3) model is determined by a non-trivial conformal fixed point. We provide evidence for a slowly walking behavior near the fixed point and we perform a finite-size scaling analysis of the mass gap.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PRINCIPALS Accidents in agriculture are a problem of global importance. The hazards of working in agriculture are manifold (machines, animals, heights). We therefore assessed injury severity and mortality from accidents in farming. METHODS We retrospectively analysed all farming accidents treated over a 12-year period in the emergency department (ED) of our level I trauma centre. RESULTS Out of 815 patients 96.3% were male and 3.7% female (p <0.0001). A total of 70 patients (8.6%, 70/815) were severely injured. Patients with injuries to the chest were most likely to suffer from severe injuries (odds ratio [OR] 9.45, 95% confidence interval [CI] 5.59-16.00, p <0.0001), followed by patients with injuries to the abdomen (OR 7.06, 95% CI 3.22-15.43, p <0.0001) and patients with injuries to the head (OR 5.03, 95% CI 2.99-8.66, p <0.0001). Hospitalisation was associated with machine- and fall-related injuries (OR 22.39, 95% CI 1.95-4.14, p <0.0001 and OR 2.84 95% CI 1.68-3.41 p <0.001, respectively). Patients suffering from a fall and patients with severe injury were more likely to die than others (OR 3.32, 95% CI 1.07-10.29, p <0.037 and OR 9.17, 95% CI 6.20-13.56, p <0.0001, respectively). Fall height correlated positively with the injury severity score , hospitalisation and mortality (all p <0.0001). CONCLUSION Injuries in agriculture are accompanied by substantial morbidity and mortality, and range from minor injuries to severe multiple injuries. Additional prospective studies should be conducted on injury severity, long-term disability and mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glaucoma is a collection of diseases characterized by multifactorial progressive changes leading to visual field loss and optic neuropathy most frequently due to elevated intraocular pressure (IOP). The goal of treatment is the lowering of the IOP to prevent additional optic nerve damage. Treatment usually begins with topical pharmacological agents as monotherapy, progresses to combination therapy with agents from up to 4 different classes of IOP-lowering medications, and then proceeds to laser or incisional surgical modalities for refractory cases. The fixed combination therapy with the carbonic anhydrase inhibitor dorzolamide hydrochloride 2% and the beta blocker timolol maleate 0.5% is now available in a generic formulation for the treatment of patients who have not responded sufficiently to monotherapy with beta adrenergic blockers. In pre- and postmarketing clinical studies, the fixed combination dorzolamide-timolol has been shown to be safe and efficacious, and well tolerated by patients. The fixed combination dorzolamide-timolol is convenient for patients, reduces their dosing regimen with the goal of increasing their compliance, reduces the effects of "washout" when instilling multiple drops, and reduces the preservative burden by reducing the number of drops administered per day.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Migration is an important event in many animal life histories, but the degree to which individual animals participate in seasonal migrations often varies within populations. The powerful ecological and evolutionary consequences of such partial migration are now well documented, but the underlying mechanisms are still heavily debated. One potential mechanism of partial migration is between-individual variation in body condition, where animals in poor condition cannot pay the costs of migration and hence adopt a resident strategy. However, underlying intrinsic traits may overrule such environmental influence, dictating individual consistency in migratory patterns. Unfortunately, field tests of individual consistency compared to the importance of individual condition on migratory propensity are rare. Here we analyse 6 years of field data on roach migration, gathered by tagging almost 3000 individual fish and monitoring their seasonal migrations over extended periods of time. Our aims were to provide a field test of the role of condition in wild fish for migratory decisions, and also to assess individual consistency in migratory tendency. Our analyses reveal that (1) migratory strategy, in terms of migration/residency, is highly consistent within individuals over time and (2) there is a positive relationship between condition and the probability of migration, but only in individuals that adopt a migratory strategy at some point during their lives. However, life-long residents do not differ in condition to migrants, hence body condition is only a good predictor of migratory tendency in fish with migratory phenotypes and not a more general determinant of migratory tendency for the population. As resident individuals can achieve very high body condition and still remain resident, we suggest that our data provides some of the first field evidence to show that both facultative and obligate strategies can co-exist within populations of migratory animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS No standardized local thrombolysis regimen exists for the treatment of pulmonary embolism (PE). We retrospectively investigated efficacy and safety of fixed low-dose ultrasound-assisted catheter-directed thrombolysis (USAT) for intermediate- and high-risk PE. METHODS AND RESULTS Fifty-two patients (65 ± 14 years) of whom 14 had high-risk PE (troponin positive in all) and 38 intermediate-risk PE (troponin positive in 91%) were treated with intravenous unfractionated heparin and USAT using 10 mg of recombinant tissue plasminogen activator per device over the course of 15 h. Bilateral USAT was performed in 83% of patients. During 3-month follow-up, two [3.8%; 95% confidence interval (CI) 0.5-13%] patients died (one from cardiogenic shock and one from recurrent PE). Major non-fatal bleeding occurred in two (3.8%; 95% CI, 0.5-13%) patients: one intrathoracic bleeding after cardiopulmonary resuscitation requiring transfusion, one intrapulmonary bleeding requiring lobectomy. Mean pulmonary artery pressure decreased from 37 ± 9 mmHg at baseline to 25 ± 8 mmHg at 15 h (P < 0.001) and cardiac index increased from 2.0 ± 0.7 to 2.7 ± 0.9 L/min/m(2) (P < 0.001). Echocardiographic right-to-left ventricular end-diastolic dimension ratio decreased from 1.42 ± 0.21 at baseline to 1.06 ± 0.23 at 24 h (n = 21; P < 0.001). The greatest haemodynamic benefit from USAT was found in patients with high-risk PE and in those with symptom duration < 14 days. CONCLUSION A standardized catheter intervention approach using fixed low-dose USAT for the treatment of intermediate- and high-risk PE was associated with rapid improvement in haemodynamic parameters and low rates of bleeding complications and mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To assess the 5-year survival rate and number of technical, biologic, and esthetic complications involving implant abutments. Materials and Methods: Electronic (Medline) and hand searches were performed to assess studies on metal and ceramic implant abutments. Relevant data from a previous review were included. Two reviewers independently extracted the data. Failure and complication rates were analyzed, and estimates of 5-year survival proportions were calculated from the relationship between event rate and survival function. Multivariable robust Poisson regression was used to compare abutment characteristics. Results: The search yielded 1,558 titles and 274 abstracts. Twenty-four studies were selected for data analysis. The survival rate for ceramic abutments was 97.5% (95% confidence interval [CI]): 89.6% to 99.4%) and 97.6% (95% CI: 96.2% to 98.5%) for metal abutments. The overall 5-year rate for technical complications was 11.8% (95% CI: 8.5% to 16.3%), 8.9% (95% CI: 4.3% to 17.7%) for ceramic and 12.0% (95% CI: 8.5% to 16.8%) for metal abutments. Biologic complications occurred with an overall rate of 6.4% (95% CI: 3.3% to 12.0%), 10.4% (95% CI: 1.9% to 46.7%) for ceramic, and 6.1% (95% CI: 3.1% to 12.0%) for metal abutments. Conclusions: The present meta-analysis on single-implant prostheses presents high survival rates of single implants, abutments, and prostheses after 5 years of function. No differences were found for the survival and failure rates of ceramic and metal abutments. No significant differences were found for technical, biologic, and esthetic complications of internally and externally connected abutments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with ilio-femoral deep-vein thrombosis (DVT) are at high risk of developing the post-thrombotic syndrome (PTS). In comparison to anticoagulation therapy alone, extended venography-guided catheter-directed thrombolysis without routine stenting of venous stenosis in patients with ilio-femoral DVT is associated with an increased risk of bleeding and a moderate reduction of PTS. We performed a prospective single-centre study to investigate safety, patency and incidence of PTS in patients with acute ilio-femoral DVT treated with fixed-dose ultrasound-assisted catheter-directed thrombolysis (USAT; 20 mg rt-PA during 15 hours) followed by routing stenting of venous stenosis, defined as residual luminal narrowing >50%, absent antegrade flow, or presence of collateral flow at the site of suspected stenosis. A total of 87 patients (age 46 ± 21 years, 60% women) were included. At 15 hours, thrombolysis success ≥50% was achieved in 67 (77%) patients. Venous stenting (mean 1.9 ± 1.3 stents) was performed in 70 (80%) patients, with the common iliac vein as the most frequent stenting site (83%). One major (1%; 95% CI, 0-6%) and 6 minor bleedings (7%; 95%CI, 3-14%) occurred. Primary and secondary patency rates at 1 year were 87% (95% CI, 74-94%) and 96% (95% CI, 88-99%), respectively. At three months, 88% (95% CI, 78-94%) of patients were free from PTS according to the Villalta scale, with a similar rate at one year (94%, 95% CI, 81-99%). In conclusion, a fixed-dose USAT regimen followed by routine stenting of underlying venous stenosis in patients with ilio-femoral DVT was associated with a low bleeding rate, high patency rates, and a low incidence of PTS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM Several surveys evaluate different retention approaches among orthodontists, but none exist for general dentists. The primary aim of this survey was to record the preferred fixed retainer designs and retention protocols amongst general dentists and orthodontists in Switzerland. A secondary aim was to investigate whether retention patterns were associated with parameters such as gender, university of graduation, time in practice, and specialist status. METHODS An anonymized questionnaire was distributed to general dentists (n = 401) and orthodontists (n = 398) practicing in the German-speaking part of Switzerland. A total of 768 questionnaires could be delivered, 562 (73.2 %) were returned and evaluated. Descriptive statistics were performed and responses to questions of interest were converted to binary outcomes and analyzed using multiple logistic regression. Any associations between the answers and gender, university of graduation (Swiss or foreign), years in practice, and specialist status (orthodontist/general dentist) were assessed. RESULTS Almost all responding orthodontists (98.0 %) and nearly a third of general dentists (29.6 %) reported bonding fixed retainers regularly. The answers were not associated with the practitioner's gender. The university of graduation and number of years in practice had a moderate impact on the responses. The answers were mostly influenced by specialist status. CONCLUSION Graduation school, years in practice, and specialist status influence retention protocol, and evidence-based guidelines for fixed retention should be issued to minimize these effects. Based on the observation that bonding and maintenance of retainers are also performed by general dentists, these guidelines should be taught in dental school and not during post-graduate training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To identify the timing of significant arch dimensional increases during orthodontic alignment involving round and rectangular nickel-titanium (NiTi) wires and rectangular stainless steel (SS). A secondary aim was to compare the timing of changes occurring with conventional and self-ligating fixed appliance systems. METHODS In this non-primary publication, additional data from a multicenter randomised trial initially involving 96 patients, aged 16 years and above, were analysed. The main pre-specified outcome measures were the magnitude and timing of maxillary intercanine, interpremolar, and intermolar dimensions. Each participant underwent alignment with a standard Damon (Ormco, Orange, CA) wire sequence for a minimum of 34 weeks. Blinding of clinicians and patients was not possible; however, outcome assessors and data analysts were kept blind to the appliance type during data analysis. RESULTS Complete data were obtained from 71 subjects. Significant arch dimensional changes were observed relatively early in treatment. In particular, changes in maxillary inter-first and second premolar dimensions occurred after alignment with an 0.014in. NiTi wire (P<0.05). No statistical differences in transverse dimensions were found between rectangular NiTi and working SS wires for each transverse dimension (P>0.05). Bracket type had no significant effect on the timing of the transverse dimensional changes. CONCLUSIONS Arch dimensional changes were found to occur relatively early in treatment, irrespective of the appliance type. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed. CLINICAL SIGNIFICANCE On the basis of this research orthodontic expansion may occur relatively early in treatment. Nickel-titanium wires may have a more profound effect on transverse dimensions than previously believed.