992 resultados para field efficiency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined clinical and sonographic classification of hepatosplenic schistosomiasis mansoni to be used in field-based studies is proposed herein. Seven hundred forty one individuals out of 892 (83%), living in an area endemic for schistosomiasis in Brazil, have been ubmitted to clinical and ultrasound examinations. Based on two stool examinations the overall prevalence for schistosomiasis in this area was 73%. Abdominal palpation was performed with patients in dorsal decubit, during deep breath, by two experienced physicians and a portable ultrasound was used for the evaluation of liver fibrosis, portal collaterals and spleen size. Four groups of individuals were identified using data obtained by abdominal palpation and ultrasound examination: (1) palpable spleen and intense periportal thickening in 9 individuals (1.2%); (2) spleen not palpable and intense periportal thickening in 15 (2%); (3) palpable spleen with light to moderate periportal thickening in 32 (4.3%), and (4) palpable spleen with a normal liver on ultrasound in 30 (4%). The definition of hepatosplenic schistosomiasis in field-based studies as the finding of Schistosoma mansoni eggs in the stools in an individual with splenomegaly is not acceptable anymore. Abdominal ultrasound should be combined with clinical examination to accurately identify hepatosplenics in endemic areas for schistosomiasis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Recent developments of MR imaging equipment enabled high-quality steady state-free-precession (Balanced FFE, True-FISP) MR-imaging with a substantial 'T2 like' contrast, resulting in a high signal intensity of the blood-pool without the application of exogenous contrast agents. It is hypothesized that Balanced-FFE may be valuable for contrast enhancement in 3D free-breathing coronary MRA. MATERIALS AND METHODS: Navigator-gated free-breathing cardiac triggered coronary MRA was performed in 10 healthy adult subjects and three patients with radiograph defined coronary artery disease using a segmented k-space 3D Balanced FFE imaging sequence. RESULTS: High contrast-to-noise ratio between the blood-pool and the myocardium (29 +/- 8) and long segment visualization of both coronary arteries could be obtained in about 5 minutes during free breathing using the present navigator-gated Balanced-FFE coronary MRA approach. First patient results demonstrated successful display of coronary artery stenoses. CONCLUSION: Balanced FFE offers a potential alternative for endogenous contrast enhancement in navigator-gated free-breathing 3D coronary MRA. The obtained results together with the relatively short scanning time warrant further studies in larger patient collectives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

n this paper the iterative MSFV method is extended to include the sequential implicit simulation of time dependent problems involving the solution of a system of pressure-saturation equations. To control numerical errors in simulation results, an error estimate, based on the residual of the MSFV approximate pressure field, is introduced. In the initial time steps in simulation iterations are employed until a specified accuracy in pressure is achieved. This initial solution is then used to improve the localization assumption at later time steps. Additional iterations in pressure solution are employed only when the pressure residual becomes larger than a specified threshold value. Efficiency of the strategy and the error control criteria are numerically investigated. This paper also shows that it is possible to derive an a-priori estimate and control based on the allowed pressure-equation residual to guarantee the desired accuracy in saturation calculation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the central role of quantitative PCR (qPCR) in the quantification of mRNA transcripts, most analyses of qPCR data are still delegated to the software that comes with the qPCR apparatus. This is especially true for the handling of the fluorescence baseline. This article shows that baseline estimation errors are directly reflected in the observed PCR efficiency values and are thus propagated exponentially in the estimated starting concentrations as well as 'fold-difference' results. Because of the unknown origin and kinetics of the baseline fluorescence, the fluorescence values monitored in the initial cycles of the PCR reaction cannot be used to estimate a useful baseline value. An algorithm that estimates the baseline by reconstructing the log-linear phase downward from the early plateau phase of the PCR reaction was developed and shown to lead to very reproducible PCR efficiency values. PCR efficiency values were determined per sample by fitting a regression line to a subset of data points in the log-linear phase. The variability, as well as the bias, in qPCR results was significantly reduced when the mean of these PCR efficiencies per amplicon was used in the calculation of an estimate of the starting concentration per sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The finding of Panstrongylus geniculatus nymphs inside a house in northeastern Antioquia, Colombia, and the reports related to their increasing presence in homes suggest the need for surveillance methods for monitoring the invasion processes. We analyzed the morphological differences between a wild population and its laboratory descendants, using the techniques of geometric morphometry, with the idea that such differences might parallel those between sylvatic and synanthropic populations. The analyses over five generations showed differences in size but not in shape. Head size and wing size were both reduced from sylvatic to laboratory populations, but the decrease in head size occurred only up to the second generation while the decrease in wing size proceeded up to the fifth generation. In contrast, although a decrease in sexual size dimorphism has been proposed as a marker of colonization in human dwellings, we did not detect any significant loss of dimorphism between sexes of P. geniculatus over the five generations studied. We conclude that size changes may have a physiological origin in response to a change of ecotopes, but more than five generations may be required for the expression of permanent morphological markers of human dwellings colonization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The large spatial inhomogeneity in transmit B, field (B-1(+)) observable in human MR images at hi h static magnetic fields (B-0) severely impairs image quality. To overcome this effect in brain T-1-weighted images the, MPRAGE sequence was modified to generate two different images at different inversion times MP2RAGE By combining the two images in a novel fashion, it was possible to create T-1-weigthed images where the result image was free of proton density contrast, T-2* contrast, reception bias field, and, to first order transmit field inhomogeneity. MP2RAGE sequence parameters were optimized using Bloch equations to maximize contrast-to-noise ratio per unit of time between brain tissues and minimize the effect of B-1(+) variations through space. Images of high anatomical quality and excellent brain tissue differentiation suitable for applications such as segmentation and voxel-based morphometry were obtained at 3 and 7 T. From such T-1-weighted images, acquired within 12 min, high-resolution 3D T-1 maps were routinely calculated at 7 T with sub-millimeter voxel resolution (0.65-0.85 mm isotropic). T-1 maps were validated in phantom experiments. In humans, the T, values obtained at 7 T were 1.15 +/- 0.06 s for white matter (WM) and 1.92 +/- 0.16 s for grey matter (GM), in good agreement with literature values obtained at lower spatial resolution. At 3 T, where whole-brain acquisitions with 1 mm isotropic voxels were acquired in 8 min the T-1 values obtained (0.81 +/- 0.03 S for WM and 1.35 +/- 0.05 for GM) were once again found to be in very good agreement with values in the literature. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actinic keratosis (AK) affects millions of people worldwide, and its prevalence continues to increase. AK lesions are caused by chronic ultraviolet radiation exposure, and the presence of two or more AK lesions along with photodamage should raise the consideration of a diagnosis of field cancerization. Effective treatment of individual lesions as well as field cancerization is essential for good long-term outcomes. The Swiss Registry of Actinic Keratosis Treatment (REAKT) Working Group has developed clinical practice guidelines for the treatment of field cancerization in patients who present with AK. These guidelines are intended to serve as a resource for physicians as to the most appropriate treatment and management of AK and field cancerization based on current evidence and the combined practical experience of the authors. Treatment of AK and field cancerization should be driven by consideration of relevant patient, disease, and treatment factors, and appropriate treatment decisions will differ from patient to patient. Prevention measures and screening recommendations are discussed, and special considerations related to management of immunocompromised patients are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The control of optical fields on the nanometre scale is becoming an increasingly important tool in many fields, ranging from channelling light delivery in photovoltaics and light emitting diodes to increasing the sensitivity of chemical sensors to single molecule levels. The ability to design and manipulate light fields with specific frequency and space characteristics is explored in this project. We present an alternative realisation of Extraordinary Optical Transmission (EOT) that requires only a single aperture and a coupled waveguide. We show how this waveguide-resonant EOT improves the transmissivity of single apertures. An important technique in imaging is Near-Field Scanning Optical Microscopy (NSOM); we show how waveguide-resonant EOT and the novel probe design assist in improving the efficiency of NSOM probes by two orders of magnitude, and allow the imaging of single molecules with an optical resolution of as good as 50 nm. We show how optical antennas are fabricated into the apex of sharp tips and can be used in a near-field configuration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes targeting of the ventro-intermediate nucleus of the thalamus (e.g. Vim) for tremor. We currently perform an indirect targeting, as the Vim is not visible on current 3Tesla MRI acquisitions. Our objective was to enhance anatomic imaging (aiming at refining the precision of anatomic target selection by direct visualisation) in patients treated for tremor with Vim GKS, by using high field 7T MRI. MATERIALS AND METHODSH: Five young healthy subjects were scanned on 3 (T1-w and diffusion tensor imaging) and 7T (high-resolution susceptibility weighted images (SWI)) MRI in Lausanne. All images were further integrated for the first time into the Gamma Plan Software(®) (Elekta Instruments, AB, Sweden) and co-registered (with T1 was a reference). A simulation of targeting of the Vim was done using various methods on the 3T images. Furthermore, a correlation with the position of the found target with the 7T SWI was performed. The atlas of Morel et al. (Zurich, CH) was used to confirm the findings on a detailed analysis inside/outside the Gamma Plan. RESULTS: The use of SWI provided us with a superior resolution and an improved image contrast within the basal ganglia. This allowed visualization and direct delineation of some subgroups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed on 3T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim-target area was created on the basis of the obtained images. CONCLUSION: This is the first report of the integration of SWI high field MRI into the LGP, aiming at the improvement of targeting validation of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g. quadrilatere of Guyot, histological atlases) seems to show a very good anatomical matching. Further studies are needed to validate this technique, both by improving the accuracy of the targeting of the Vim (potentially also other thalamic nuclei) and to perform clinical assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bananal is an important focus of Schistosoma mansoni in the State of São Paulo. Accordingly, programmed active search for human cases, annual coproscopic surveys and treatment of infected cases were started in 1998, aiming at producing a sharp prevalence rate drop by the year 2000. S. mansoni eggs were searched for in two Kato-Katz slides per patient. Cases were followed up according to the routine of the local Family Health Program. In 1998, 130 samples out of 3,860 showed S. mansoni eggs; in 1999, 105 out of 3,550, and in 2000, 64 out of 3,528. Prevalence rates were 3.4%, 2.9%, and 1.8%, and average egg-counts 59, 64, and 79 eggs per gram of feces respectively. Prevalence rates decreased steadily after treatment, but persistently positive cases showed no significant decrease in parasite burdens. Egg count variation depended on sex and age bracket. Persistent residual cases admittedly preclude the eradication of this infection by only searching for and treating carriers. In addition, resistance to therapy and low sensitivity of fecal examinations, can not be ignored. Moderate to heavy worm burdens, frequently associated with hepatomegaly elsewhere, produced no serious cases in Bananal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Value for Money Report – The Efficiency and Effectiveness of Long-Stay Residential Care for Adults within the Mental Health Services Executive Summary and Contents PDF 164kb Chapters 1 and 2 – Introduction and Service Objectives PDF 504kb Chapter 3 plus annexes – Service Effectiveness and Efficiency PDF 3.7mb Chapter 4 – Service Resources PDF 2.4mb Chapters 5, 6 and 7 – Future Funding and Alternative Approaches, Key Performance Indicators, Conclusions and Recommendations PDF 2.4mb Appendices 1 to 6

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report On Public Consultation: Efficiency And Effectiveness Of Disability Services In Ireland Click here to download PDF 1.67MB Other Relevant Documents: Click here to download Appendix A PDF 1.06MB Click here to download Summary of Key Proposals from The Review of Disability Policy PDF 250KB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different interferometric techniques were developed last decade to obtain full field, quantitative, and absolute phase imaging, such as phase-shifting, Fourier phase microscopy, Hilbert phase microscopy or digital holographic microscopy (DHM). Although, these techniques are very similar, DHM combines several advantages. In contrast, to phase shifting, DHM is indeed capable of single-shot hologram recording allowing a real-time absolute phase imaging. On the other hand, unlike to Fourier phase or Hilbert phase microscopy, DHM does not require to record in focus images of the specimen on the digital detector (CCD or CMOS camera), because a numerical focalization adjustment can be performed by a numerical wavefront propagation. Consequently, the depth of view of high NA microscope objectives is numerically extended. For example, two different biological cells, floating at different depths in a liquid, can be focalized numerically from the same digital hologram. Moreover, the numerical propagation associated to digital optics and automatic fitting procedures, permits vibrations insensitive full- field phase imaging and the complete compensation for a priori any image distortion or/and phase aberrations introduced for example by imperfections of holders or perfusion chamber. Examples of real-time full-field phase images of biological cells have been demonstrated. ©2008 COPYRIGHT SPIE