975 resultados para femtosecond optical heterodyne detection of optical Kerr


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new VITEK 2 antibiotic susceptibility testing (AST) card, AST N-054, was introduced for aerobic gram-negative bacilli in 2007 and has been widely adopted for routine use in the UK. We evaluated its performance for detecting extended-spectrum beta-lactamase (ESBL) production in Escherichia coli.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In contrast to the multitude of studies on fungal PCR assay methods, little work has been reported evaluating Candida PCR performance when using whole blood compared with serum in candidaemic patients. Here, a comparison of the performance of whole-blood and serum specimens using a set of real-time PCR Candida species assays is described. Specimens were collected prospectively from non-neutropenic adults who were recruited to a diagnostic clinical trial, the primary purpose of which was to verify the performance of the assays using serum; in all, 104 participants also had whole-blood specimens submitted for analysis in addition to the serum specimen. Of these participants, 10 had laboratory-confirmed candidaemia and 94 were categorized as being 'unlikely' to have invasive Candida infection. PCR results from the whole-blood specimens are presented here and compared with the results from serum specimens in this subgroup among whom both specimen types were obtained contemporaneously. All participants with candidaemia were PCR-positive from serum samples; however, only seven were PCR-positive from whole blood. All specimens from patients in the 'unlikely' category were PCR-negative in both types of specimen. Moreover, DNA extraction from serum required 1 h; extraction from whole blood required approximately 3 h. These data tentatively suggest that, overall, serum is an appropriate specimen for Candida PCR for detection of candidaemia in non-neutropenic adults.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The limitations of classical diagnostic methods for invasive Candida infections have led to the development of molecular techniques such as real-time PCR to improve diagnosis. However, the detection of low titres of Candida DNA in blood from patients with candidaemia requires the use of extraction methods that efficiently lyse yeast cells and recover small amounts of DNA suitable for amplification. In this study, a Candida-specific real-time PCR assay was used to detect Candida albicans DNA in inoculated whole blood specimens extracted using seven different extraction protocols. The yield and quality of total nucleic acids were estimated using UV absorbance, and specific recovery of C. albicans genomic DNA was estimated quantitatively in comparison with a reference (Qiagen kit/lyticase) method currently in use in our laboratory. The extraction protocols were also compared with respect to sensitivity, cost and time required for completion. The TaqMan PCR assay used to amplify the DNA extracts achieved high levels of specificity, sensitivity and reproducibility. Of the seven extraction protocols evaluated, only the MasterPure yeast DNA extraction reagent kit gave significantly higher total nucleic acid yields than the reference method, although nucleic acid purity was highest using either the reference or YeaStar genomic DNA kit methods. More importantly, the YeaStar method enabled C. albicans DNA to be detected with highest sensitivity over the entire range of copy numbers evaluated, and appears to be an optimal method for extracting Candida DNA from whole blood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GC-MS data on veterinary drug residues in bovine urine are used for controlling the illegal practice of fattening cattle. According to current detection criteria, peak patterns of preferably four ions should agree within 10 or 20% from a corresponding standard pattern. These criteria are rigid, rather arbitrary and do not match daily practice. A new model, based on multivariate modeling of log peak abundance ratios, provides a theoretical basis for the identification of analytes and optimizes the balance between the avoidance of false positives and false negatives. The performance of the model is demonstrated on data provided by five laboratories, each supplying GC-MS measurements on the detection of clenbuterol, dienestrol and 19 beta-nortestosterone in urine. The proposed model shows a better performance than confirmation by using the current criteria and provides a statistical basis for inspection criteria in terms of error probabilities.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

3-amino-2-oxazolidinone (AOZ) is a tissue bound toxic metabolite derived from the nitrofuran antibiotic, furazolidone. AOZ is detected in the derivatised form of 3-{[(2-nitrophenyl) methylene]amino}-2-oxazolidinone (NP AOZ). 3-{[( 3- carboxyphenyl)-methylene]amino-2-oxazolidinone (CP AOZ) was used as the immunising hapten for the production of monoclonal antibodies against NP AOZ. Monoclonal antibodies were produced using hybridomas from the fusion of murine myeloma cells and spleen cells isolated from BALB/c mice immunised with CP AOZ-ethylenediamine-human serum albumin (CP AOZ-ed-HSA). The antibody production in ascitic fluids from clones 3B8/2B9 and 2D11/A4 was monitored during a 16 month period. Repeated cultures of these hybridomas, followed by injection into mice and cloning did not change the assay parameters. Clone 2D11/A4 exhibited long term stability in antibody production throughout the experiment whereas clone 3B8/2B9 demonstrated variability in particular antibody yields whilst retaining assay sensitivity. Reasons for this production variability in clones are discussed. In an optimised direct ELISA format, the antibodies exhibited a 50% binding inhibition in the range of 0.52-1.15 ng/ml with NP AOZ (0.22-0.50 ng/ml, respective AOZ equivalents) and showed high specificity towards this analyte. The sensitivity of monoclonal antibodies incorporated into the ELISA is compatible with the European Union MRLP and is currently in use for routine analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seismic geophysical methods have rarely been used in precision agriculture, predominantly due to the perception that they are slow and results require a complex evaluation. This paper explores the possibility of using a recently developed surface wave seismic geophysical approach, the multichannel analysis of surface waves (MASW) method, for assessment of agricultural compaction. This approach has the advantage of being non-intrusive, rapid and is able to produce 2D ground models with a relatively high density of spatial sampling points. The method, which was tested on a research site in Oakpark, Ireland, detected a significant difference in shear wave velocity between a heavily compacted headland and an uncompacted location. The results from this approach compared favourably with those obtained
from measurements of bulk density and penetrometer resistance and demonstrate that the MASW approach can distinguish between the extreme states of heavily compacted and uncompacted soil.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although earthworms have been found to inhabit arsenic-rich soils in the U.K., the mode of arsenic detoxification is currently unknown. Biochemical analyses and subcellular localization studies have indicated that As3+-thiol complexes may be involved; however, it is not known whether arsenic is capable of inducing the expression of metallothionein (MT) in earthworms. The specific aims of this paper were (a) to detect and gain an atomic characterization of ligand complexing by X-ray absorption spectrometry (XAS), and (b) to employ a polyclonal antibody raised against an earthworm MT isoform (w-MT2) to detect and localize the metalloprotein by immunoperoxidase histochemistry in the tissues of earthworms sampled from arsenic-rich soil. Data suggested that the proportion of arsenate to sulfur-bound species varies within specific earthworm tissues. Although some arsenic appeared to be in the form of arsenobetaine, the arsenic within the chlorogogenous tissue was predominantly coordinated with S in the form of -SH groups. This suggests the presence of an As::MT complex. Indeed, MT was detectable with a distinctly localized tissue and cellular distribution. While MT was not detectable in the surface epithelium or in the body wall musculature, immunoperoxidase histochemistry identified the presence of MT in chloragocytes around blood vessels, within the typhlosolar fold, and in the peri-intestinal region. Focal immunostaining was also detectable in a cohort of cells in the intestinal wall. The results of this study support the hypothesis that arsenic induces MT expression and is sequestered by the metalloprotein in certain target cells and tissues.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bacteroides fragilis is a constituent of the normal resident microbiota of the human intestine and is the gram-negative obligately anaerobic bacterium most frequently isolated from clinical infection. Surface polysaccharides are implicated as potential virulence determinants. We present evidence of within strain immunochemical variation of surface polysaccharides in populations that are noncapsulate by light microscopy as determined by monoclonal antibody labelling. Expression of individual epitopes can be enriched from a population of an individual strain by use of immunomagnetic beads. Also, individual colonies in which either >94% or 94% of the bacteria carry a given epitope, there is no enrichment for other epitopes recognized by different polysaccharide-specific monoclonal antibodies. This intrastrain variation has important implications for the development of potential vaccines or immunodiagnostic tests.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When people evaluate syllogisms, their judgments of validity are often biased by the believability of the conclusions of the problems. Thus, it has been suggested that syllogistic reasoning performance is based on an interplay between a conscious and effortful evaluation of logicality and an intuitive appreciation of the believability of the conclusions (e.g., Evans, Newstead, Allen, & Pollard, 1994). However, logic effects in syllogistic reasoning emerge even when participants are unlikely to carry out a full logical analysis of the problems (e.g., Shynkaruk & Thompson, 2006). There is also evidence that people can implicitly detect the conflict between their beliefs and the validity of the problems, even if they are unable to consciously produce a logical response (e.g., De Neys, Moyens, & Vansteenwegen, 2010). In 4 experiments we demonstrate that people intuitively detect the logicality of syllogisms, and this effect emerges independently of participants' conscious mindset and their cognitive capacity. This logic effect is also unrelated to the superficial structure of the problems. Additionally, we provide evidence that the logicality of the syllogisms is detected through slight changes in participants' affective states. In fact, subliminal affective priming had an effect on participants' subjective evaluations of the problems. Finally, when participants misattributed their emotional reactions to background music, this significantly reduced the logic effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Immunomagnetic separation (IMS) can selectively isolate and concentrate Mycobacterium bovis cells from lymph node tissue to facilitate subsequent detection by PCR (IMS-PCR) or culture (IMS-MGIT). This study describes application of these novel IMS-based methods to test for M. bovis in a survey of 280 bovine lymph nodes (206 visibly lesioned (VL), 74 non-visibly lesioned (NVL)) collected at slaughter as part of the Northern Ireland bovine TB eradication programme. Their performance was evaluated relative to culture. Overall, 174 (62.1%) lymph node samples tested positive by culture, 162 (57.8%) by IMS-PCR (targeting IS6110), and 196 (70.0%) by IMS-MGIT culture. Twelve (6.9%) of the 174 culture positive lymph node samples were not detected by either of the IMS-based methods. However, an additional 78 M. bovis positive lymph node samples (26 (12.6%) VL and 54 (73.0%) NVL) were detected by the IMS-based methods and not by culture. When low numbers of viable M. bovis are present in lymph nodes (e.g. in NVLs of skin test reactor cattle) decontamination prior to culture may adversely affect viability, leading to false negative culture results. In contrast, IMS specifically captures whole M. bovis cells (live, dead or potentially dormant) which are not subject to any deleterious treatment before detection by PCR or MGIT culture. During this study only 2.7% of NVL lymph nodes tested culture positive, whereas 73% of the same samples tested M. bovis positive by the IMS-based tests. Results clearly demonstrate that not only are the IMS-based methods more rapid but they have greater detection sensitivity than the culture approach currently used for the detection of M. bovis infection in cattle.. Adoption of the IMS-based methods for lymph node testing would have the potential to improve M. bovis detection in clinical samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Plant pathogens are a serious problem for seed export, plant disease control and plant quarantine. Rapid and accurate screening tests are urgently required to protect and prevent plant diseases spreading worldwide. A novel multiplex detection method was developed based on microsphere immunoassays to simultaneously detect four important plant pathogens: a fruit blotch bacterium Acidovorax avenae subsp. citrulli (Aac), chilli vein-banding mottle virus (CVbMV, potyvirus), watermelon silver mottle virus (WSMoV, tospovirus serogroup IV) and melon yellow spot virus (MYSV, tospovirus). An antibody for each plant pathogen was linked on a fluorescence-coded magnetic microsphere set which was used to capture corresponding pathogen. The presence of pathogens was detected by R-phycoerythrin (RPE)-labeled antibodies specific to the pathogens. The assay conditions were optimized by identifying appropriate antibody pairs, blocking buffer, concentration of RPE-labeled antibodies and assay time. Once conditions were optimized, the assay was able to detect all four plant pathogens precisely and accurately with substantially higher sensitivity than enzyme-linked immunosorbent assay (ELISA) when spiked in buffer and in healthy watermelon leaf extract. The assay time of the microsphere immunoassay (1 hour) was much shorter than that of ELISA (4 hours). This system was also shown to be capable of detecting the pathogens in naturally infected plant samples and is a major advancement in plant pathogen detection. © 2013 Charlermroj et al.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Unregulated growth promoter use in food-producing animals is an issue of concern both from food safety and animal welfare perspectives. However, the monitoring of such practices is analytically challenging due to the concerted actions of users to evade detection. Techniques based on the monitoring of biological responses to exogenous administrations have been proposed as more sensitive methods to identify treated animals. This study has, for the first time, profiled plasma proteome responses in bovine animals to treatment with nortestosterone decanoate and 17 beta-oestradiol benzoate, followed by dexamethasone administration. Two-dimensional fluorescence differential in-gel electrophoresis analysis revealed a series of hepatic and acute-phase proteins within plasma whose levels were up- or down-regulated within phases of the treatment regime. Surface plasmon resonance (SPR) immuno-assays were developed to quantify responses of identified protein markers during the experimental treatment study with a view to developing methods which can be used as screening tools for growth promoter abuse detection. SPR analysis demonstrated the potential for plasma proteins to be used as indicative measures of growth promoter administrations and concludes that the sensitivity and robustness of any detection approach based on plasma proteome analysis would benefit from examination of a range of proteins representative of diverse biological processes rather being reliant on specific individual markers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report observations of the dwarf star e Eri (K2V) made with the Space Telescope Imaging Spectrograph (STIS) on the Hubble Space Telescope. The high sensitivity of the STIS instrument has allowed us to detect the magnetic dipole transitions of Fe XII at 1242.00 and 1349 38 Å for the first time in a star other than the Sun. The width of the stronger line at 1242.00 Å has also been measured; such measurements are not possible for the permitted lines of Fe XII in the extreme-ultraviolet. To within the accuracy of the measurements the N v and the Fe XII lines occur at their rest wavelengths. Electron densities and linewidths have been measured from other transition region lines. Together, these can be used to investigate the non-thermal energy flux in the lower and upper transition regions, which is useful in constraining possible heating processes. The Fe XII lines are also present in archival STIS spectra of other G/K-type dwarfs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Molecular genetic assays for the detection of the JAK2 V617F (c.1849G>T) and other pathogenetic mutations within JAK2 exon 12 and MPL exon 10 are part of the routine diagnostic workup for patients presenting with erythrocytosis, thrombocytosis or otherwise suspected to have a myeloproliferative neoplasm. A wide choice of techniques are available for the detection of these mutations, leading to potential difficulties for clinical laboratories in deciding upon the most appropriate assay, which can lead to problems with inter-laboratory standardization. Here, we discuss the most important issues for a clinical diagnostic laboratory in choosing a technique, particularly for detection of the JAK2 V617F mutation at diagnosis. The JAK2 V617F detection assay should be both specific and sensitive enough to detect a mutant allele burden as low as 13%. Indeed, the use of sensitive assays increases the detection rate of the JAK2 V617F mutation within myeloproliferative neoplasms. Given their diagnostic relevance, it is also beneficial and relatively straightforward to screen JAK2 V617F negative patients for JAK2 exon 12 mutations (in the case of erythrocytosis) or MPL exon 10 mutations (thrombocytosis or myelofibrosis) using appropriate assays. Molecular results should be considered in the context of clinical findings and other haematological or laboratory results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The study details the development of a fully validated, rapid and portable sensor based method for the on-site analysis of microcystins in freshwater samples. The process employs a novel lysis method for the mechanical lysis of cyanobacterial cells, with glass beads and a handheld frother in only 10min. The assay utilises an innovative planar waveguide device that, via an evanescent wave excites fluorescent probes, for amplification of signal in a competitive immunoassay, using an anti-microcystin monoclonal with cross-reactivity against the most common, and toxic variants. Validation of the assay showed the limit of detection (LOD) to be 0.78ngmL and the CCß to be 1ngmL. Robustness of the assay was demonstrated by intra- and inter-assay testing. Intra-assay analysis had % C.V.s between 8 and 26% and recoveries between 73 and 101%, with inter-assay analysis demonstrating % C.V.s between 5 and 14% and recoveries between 78 and 91%. Comparison with LC-MS/MS showed a high correlation (R=0.9954) between the calculated concentrations of 5 different Microcystis aeruginosa cultures for total microcystin content. Total microcystin content was ascertained by the individual measurement of free and cell-bound microcystins. Free microcystins can be measured to 1ngmL, and with a 10-fold concentration step in the intracellular microcystin protocol (which brings the sample within the range of the calibration curve), intracellular pools may be determined to 0.1ngmL. This allows the determination of microcystins at and below the World Health Organisation (WHO) guideline value of 1µgL. This sensor represents a major advancement in portable analysis capabilities and has the potential for numerous other applications.