897 resultados para estimation of dynamic structural models


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estimation of the lower flammability limits of C-H compounds at 25 degrees C and 1 atm; at moderate temperatures and in presence of diluent was the objective of this study. A set of 120 degrees C H compounds was divided into a correlation set and a prediction set of 60 compounds each. The absolute average relative error for the total set was 7.89%; for the correlation set, it was 6.09%; and for the prediction set it was 9.68%. However, it was shown that by considering different sources of experimental data the values were reduced to 6.5% for the prediction set and to 6.29% for the total set. The method showed consistency with Le Chatelier's law for binary mixtures of C H compounds. When tested for a temperature range from 5 degrees C to 100 degrees C , the absolute average relative errors were 2.41% for methane; 4.78% for propane; 0.29% for iso-butane and 3.86% for propylene. When nitrogen was added, the absolute average relative errors were 2.48% for methane; 5.13% for propane; 0.11% for iso-butane and 0.15% for propylene. When carbon dioxide was added, the absolute relative errors were 1.80% for methane; 5.38% for propane; 0.86% for iso-butane and 1.06% for propylene. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Excessive rearfoot eversion is thought to be a risk factor for patellofemoral pain development, due to the kinesiological relationship with ascendant adaptations. Individuals with patellofemoral pain are often diagnosed through static clinical tests, in scientific studies and clinical practice. However, the adaptations seem to appear in dynamic conditions. Performing static vs. dynamic evaluations of widely used measures would add to the knowledge in this area. Thus, the aim of this study was to determine the reliability and differentiation capability of three rearfoot eversion measures: rearfoot range of motion, static clinical test and static measurement using a three-dimensional system. A total of 29 individuals with patellofemoral pain and 25 control individuals (18-30 years) participated in this study. Each subject underwent three-dimensional motion analysis during stair climbing and static clinical tests. Intraclass correlation coefficient and standard error measurements were performed to verify the reliability of the variables and receiver operating characteristic curves to show the diagnostic accuracy of each variable. In addition, analyses of variance were performed to identify differences between groups. Rearfoot range of motion demonstrated higher diagnostic accuracy (an area under the curve score of 0.72) than static measures and was able to differentiate the groups. Only the static clinical test presented poor and moderate reliability. Other variables presented high to very high values. Rearfoot range of motion was the variable that presented the best results in terms of reliability and differentiation capability. Static variables do not seem to be related to patellofemoral pain and have low accuracy values.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to determine the effects of motor practice on visual judgments of apertures for wheelchair locomotion and the visual control of wheelchair locomotion in wheelchair users who had no prior experience. Sixteen young adults, divided into motor practice and control groups, visually judged varying apertures as passable or impassable under walking, pre-practice, and post-practice conditions. The motor practice group underwent additional motor practice in 10 blocks of five trials each, moving the wheelchair through different apertures. The relative perceptual boundary was determined based on judgment data and kinematic variables that were calculated from videos of the motor practice trials. The participants overestimated the space needed under the walking condition and underestimated it under the wheelchair conditions, independent of group. The accuracy of judgments improved from the pre-practice to post-practice condition in both groups. During motor practice, the participants adaptively modulated wheelchair locomotion, adjusting it to the apertures available. The present findings from a priori visual judgments of space and the continuous judgments that are necessary for wheelchair approach and passage through apertures appear to support the dissociation between processes of perception and action.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Herbicides application success depends, besides product correct choice, the observation of environmental conditions and application quality. The work aimed to quantify the effects of surfactant addition in spraying solution, in natural and artificial targets, associated to different nozzle boom angles in relation to application offset, by using distinct evaluation methods. Two experiments were conducted at NuPAM-FCA/UNESP, Botucatu County, São Paulo State, constituted by ten treatments, in factorial scheme 2 × 5, corresponding to two spraying solutions conditions (absence or presence of Aterbane BRTM (0.25% v/v) adjuvant) and five angles of spray nozzle in relation to offset application (-30°, -15°, 90°, +15° and +30°). In Ipomea grandifolia leaves, the distribution and drops deposition of a tracer solution were evaluated by using scores visual and spectrophotometer process. In hydro sensible papers, volumetric medium diameter (VMD), density (cm2 ) and drops medium diameter, covered area (%) and application fees (L ha-1) were evaluated through e-SprinkleTM software. Aterbane BRTM (0.25% v/v) presence or absence, associated or no, to spray nozzles offset did not provide significant differences in I. grandifolia spray deposition. The use of artificial targets presented applicative technical limitations in relation to the use of natural ones as study matrix. Deposit and distribution variables esteem distinct behaviours, independent of target nature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)