968 resultados para door stop


Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray mammography has been the gold standard for breast imaging for decades, despite the significant limitations posed by the two dimensional (2D) image acquisitions. Difficulty in diagnosing lesions close to the chest wall and axilla, high amount of structural overlap and patient discomfort due to compression are only some of these limitations. To overcome these drawbacks, three dimensional (3D) breast imaging modalities have been developed including dual modality single photon emission computed tomography (SPECT) and computed tomography (CT) systems. This thesis focuses on the development and integration of the next generation of such a device for dedicated breast imaging. The goals of this dissertation work are to: [1] understand and characterize any effects of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without interference from the other. Such a system would overcome artifacts resulting from incompletely sampled divergent cone beam imaging schemes and allow imaging closer to the chest wall, which other systems currently under research and development elsewhere cannot achieve.

The dependence of x-ray scatter radiation on object shape, size, material composition and the CT acquisition trajectory, was investigated with a well-established beam stop array (BSA) scatter correction method. While the 2D scatter to primary ratio (SPR) was the main metric used to characterize total system scatter, a new metric called ‘normalized scatter contribution’ was developed to compare the results of scatter correction on 3D reconstructed volumes. Scatter estimation studies were undertaken with a sinusoidal saddle (±15° polar tilt) orbit and a traditional circular (AZOR) orbit. Clinical studies to acquire data for scatter correction were used to evaluate the 2D SPR on a small set of patients scanned with the AZOR orbit. Clinical SPR results showed clear dependence of scatter on breast composition and glandular tissue distribution, otherwise consistent with the overall phantom-based size and density measurements. Additionally, SPR dependence was also observed on the acquisition trajectory where 2D scatter increased with an increase in the polar tilt angle of the system.

The dose delivered by any imaging system is of primary importance from the patient’s point of view, and therefore trajectory related differences in the dose distribution in a target volume were evaluated. Monte Carlo simulations as well as physical measurements using radiochromic film were undertaken using saddle and AZOR orbits. Results illustrated that both orbits deliver comparable dose to the target volume, and only slightly differ in distribution within the volume. Simulations and measurements showed similar results, and all measured dose values were within the standard screening mammography-specific, 6 mGy dose limit, which is used as a benchmark for dose comparisons.

Hounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is very important, especially when using non-traditional trajectories. Uniform phantoms filled with various uniform density fluids were used to investigate differences in HU accuracy between saddle and AZOR orbits. Results illustrate the considerably better performance of the saddle orbit, especially close to the chest and nipple region of what would clinically be a pedant breast volume. The AZOR orbit causes shading artifacts near the nipple, due to insufficient sampling, rendering a major portion of the scanned phantom unusable, whereas the saddle orbit performs exceptionally well and provides a tighter distribution of HU values in reconstructed volumes.

Finally, the third generation, fully-suspended SPECT-CT system was designed in and developed in our lab. A novel mechanical method using a linear motor was developed for tilting the CT system. A new x-ray source and a custom made 40 x 30 cm2 detector were integrated on to this system. The SPECT system was nested, in the center of the gantry, orthogonal to the CT source-detector pair. The SPECT system tilts on a goniometer, and the newly developed CT tilting mechanism allows ±15° maximum polar tilting of the CT system. The entire gantry is mounted on a rotation stage, allowing complex arbitrary trajectories for each system, without interference from the other, while having a common field of view. This hybrid system shows potential to be used clinically as a diagnostic tool for dedicated breast imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Bioinformatics Open Source Conference (BOSC) is organized by the Open Bioinformatics Foundation (OBF), a nonprofit group dedicated to promoting the practice and philosophy of open source software development and open science within the biological research community. Since its inception in 2000, BOSC has provided bioinformatics developers with a forum for communicating the results of their latest efforts to the wider research community. BOSC offers a focused environment for developers and users to interact and share ideas about standards; software development practices; practical techniques for solving bioinformatics problems; and approaches that promote open science and sharing of data, results, and software. BOSC is run as a two-day special interest group (SIG) before the annual Intelligent Systems in Molecular Biology (ISMB) conference. BOSC 2015 took place in Dublin, Ireland, and was attended by over 125 people, about half of whom were first-time attendees. Session topics included "Data Science;" "Standards and Interoperability;" "Open Science and Reproducibility;" "Translational Bioinformatics;" "Visualization;" and "Bioinformatics Open Source Project Updates". In addition to two keynote talks and dozens of shorter talks chosen from submitted abstracts, BOSC 2015 included a panel, titled "Open Source, Open Door: Increasing Diversity in the Bioinformatics Open Source Community," that provided an opportunity for open discussion about ways to increase the diversity of participants in BOSC in particular, and in open source bioinformatics in general. The complete program of BOSC 2015 is available online at http://www.open-bio.org/wiki/BOSC_2015_Schedule.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Prenatal nicotine exposure (PNE) is linked to a large number of psychiatric disorders, including attention deficit hyperactivity disorder (ADHD). Current literature suggests that core deficits observed in ADHD reflect abnormal inhibitory control governed by the prefrontal cortex (PFC) of the brain. The PFC is structurally altered by PNE, but it is still unclear how neural firing is affected during tasks that test behavioral inhibition, such as the stop-signal task, or if neural correlates related to inhibitory control are affected after PNE in awake behaving animals. To address these questions, we recorded from single medial PFC (mPFC) neurons in control rats and PNE rats as they performed our stopsignal task. We found that PNE rats were faster for all trial types and were less likely to inhibit the behavioral response on STOP trials. Neurons in mPFC fired more strongly on STOP trials and were correlated with accuracy and reaction time. Although the number of neurons exhibiting significant modulation during task performance did not differ between groups, overall activity in PNE was reduced. We conclude that PNE makes rats impulsive and reduces firing in mPFC neurons that carry signals related to response inhibition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hemorrhage is the leading cause of preventable death after a traumatic injury. Commercial hemostatic agents exist, but have various disadvantages including high cost, short shelf-lives, or secondary tissue damage. Polymer hydrogels provide a promising platform for the use of both biological and mechanical mechanisms to accelerate natural hemostasis and control hemorrhage. The goal of this work was to develop hydrogel particles composed of chitosan and alginate and loaded with zeolite in order to stop blood loss by targeting multiple hemostatic mechanisms. Several ii particle compositions were synthesized and then characterized through swelling studies, particle sizing, Scanning Electron Microscopy (SEM), and Fourier Transform Infrared Spectroscopy (FTIR). The in vitro interactions of the particles were evaluated through coagulation, degradation, platelet aggregation, and cytotoxicity studies. The results indicate that 4% alginate, 1% chitosan, 4% zeolite-loaded hydrogel beads can significantly reduce time to coagulation and increase platelet aggregation in vitro. Future research can look into the efficacy of these particles in vivo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The generation and near-field radiation of aerodynamic sound from a low-speed unsteady flow over a two-dimensional automobile door cavity is simulated by using a source-extraction-based coupling method. In the coupling procedure, the unsteady cavity flow field is first computed solving the Reynolds averaged Navier–Stokes (RANS) equations. The radiated sound is then calculated by using a set of acoustic perturbation equations with acoustic source terms which are extracted from the time-dependent solutions of the unsteady flow. The aerodynamic and its resulting acoustic field are computed for the Reynolds number of 53,266 based on the base length of the cavity. The free stream flow velocity is taken to be 50.9m/s. As first stage of the numerical investigation of flow-induced cavity noise, laminar flow is assumed. The CFD solver is based on a cell-centered finite volume method. A dispersion-relation-preserving (DRP), optimized, fourth-order finite difference scheme with fully staggered-grid implementation is used in the acoustic solver

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the current paper, the authors present an analysis of the structural characteristics of an intermediate rail vehicle and their effects on crash performance of the vehicle. Theirs is a simulation based analysis involving four stages. First, the crashworthiness of the vehicle is assessed by simulating an impact of the vehicle with a rigid wall. Second, the structural characteristics of the vehicle are analysed based on the structural behaviour during this impact and then the structure is modified. Third, the modified vehicle is tested again in the same impact scenario with a rigid wall. Finally, the modified vehicle is subjected to a modelled head-on impact which mirrors the real-life impact interface between two intermediate vehicles in a train impact. The emphasis of the current study is on the structural characteristics of the intermediate vehicle and the differences compared to an impact of a leading vehicle. The study shows that, similar to a leading vehicle, bending, or jackknifing is a main form of failure in this conventionally designed intermediate vehicle. It has also been found that the location of the door openings creates a major difference in the behaviour of an intermediate vehicle. It causes instability of the vehicle in the door area and leads to high stresses at the joint of the end beam with the solebar and shear stresses at the joint of the inner pillar with the cantrail. Apart from this, the shapes of the vehicle ends and impact interfaces are also different and have an effect on the crash performance of the vehicles. The simulation results allow the identification of the structural characteristics and show the effectiveness of relevant modifications. The conclusions have general relevance for the crashworthiness of rail vehicle design

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Summary form only given. Currently the vast majority of adhesive materials in electronic products are bonded using convection heating or infra-red as well as UV-curing. These thermal processing steps can take several hours to perform, slowing throughput and contributing a significant portion of the cost of manufacturing. With the demand for lighter, faster, and smaller electronic devices, there is a need for innovative material processing techniques and control methodologies. The increasing demand for smaller and cheaper devices pose engineering challenges in designing a curing systems that minimize the time required between the curing of devices in a production line, allowing access to the components during curing for alignment and testing. Microwave radiation exhibits several favorable characteristics and over the past few years has attracted increased academic and industrial attention as an alternative solution to curing of flip-chip underfills, bumps, glob top and potting cure, structural bonding, die attach, wafer processing, opto-electronics assembly as well as RF-ID tag bonding. Microwave energy fundamentally accelerates the cure kinetics of polymer adhesives. It provides a route to focus heat into the polymer materials penetrating the substrates that typically remain transparent. Therefore microwave energy can be used to minimise the temperature increase in the surrounding materials. The short path between the energy source and the cured material ensures a rapid heating rate and an overall low thermal budget. In this keynote talk, we will review the principles of microwave curing of materials for high density packing. Emphasis will be placed on recent advances within ongoing research in the UK on the realization of "open-oven" cavities, tailored to address existing challenges. Open-ovens do not require positioning of the device into the cavity through a movable door, hence being more suitable for fully automated processing. Further potential advantages of op- - en-oven curing include the possibility for simultaneous fine placement and curing of the device into a larger assembly. These capabilities promise productivity gains by combining assembly, placement and bonding into a single processing step. Moreover, the proposed design allows for selective heating within a large substrate, which can be useful particularly when the latter includes parts sensitive to increased temperatures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intense AC magnetic field required to produce levitation in terrestrial conditions, along with the buoyancy and thermo-capillary forces, results in turbulent convective flow within the droplet. The use of a homogenous DC magnetic field allows the convective flow to be damped. However the turbulence properties are affected at the same time, leading to a possibility that the effective turbulent damping is considerably reduced. The MHD modified K-Omega turbulence model allows the investigation of the effect of magnetic field on the turbulence. The model incorporates free surface deformation, the temperature dependent surface tension, turbulent momentum transport, electromagnetic and gravity forces. The model is adapted to incorporate a periodic laser heating at the top of the droplet, which have been used to measure the thermal conductivity of the material by calculating the phase lag between the frequency of the laser heating and the temperature response at the bottom. The numerical simulations show that with the gradual increase of the DC field the fluid flow within the droplet is initially increasing in intensity. Only after a certain threshold magnitude of the field the flow intensity starts to decrease. In order to achieve the flow conditions close to the ‘laminar’ a D.C. magnetic field >4 Tesla is required to measure the thermal conductivity accurately. The reduction in the AC field driven flow in the main body of the drop leads to a noticeable thermo-capillary convection at the edge of the droplet. The uniform vertical DC magnetic field does not stop a translational oscillation of the droplet along the field, which is caused by the variation in total levitation force due to the time-dependent surface deformation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Written by leading paramedics and academic subject experts, with a foreword by Paul Bates, this is the first foundation level text to introduce the main theoretical subjects studied on the new higher education paramedic science programmes. It underpins practice and links ways of working to the crucial theory base. The numerous examples and case studies focus specifically on pre-hospital and emergency care. Key topics covered include: * NHS and ambulance service history * Ethics and law for the paramedic * Communication and reflective practice * Professional issues, including evidence-based practice, anti-discriminatory practice, clinical governance and clinical audit * Psychological perspectives on health and ill health * Safeguarding children * Sociological perspectives on health and ill health and social policy * Managing change and leadership theory * Continuing professional development The text prompts you to stop and think about what you have just read and relate this to your role. Throughout the book, the author carefully considers how the theory being discussed relates to the role of the ambulance clinician. Foundations for Paramedic Practice: A Theoretical Perspective is a core text for students of paramedic science and will also provide a valuable resource for students of allied health professions. This text provides a stepping stone to further reading and investigation. - Taken from the back cover of: Amanda Blaber - Foundations for paramedic practice: a theoretical perspective

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mooij, T., & Fettelaar, D. (2013). Observatie van voorlichtingslessen seksuele diversiteit in het Voortgezet Onderwijs: Een pilot onderzoek. Tijdschrift voor Orthopedagogiek, 52(6), 282-298.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is almost a tradition that celluloid (or digital) villains are represented with some characteristics that remind us the real political enemies of the producer country of the film, or even enemies within the country according to the particular ideology that sustains the film. The case of Christopher Nolan The Dark Knight trilogy, analyzed here, is representative of this trend for two reasons. First, because it gets marked by political radicalization conducted by the US government after the attack of September 11, 2001. Secondly, because it offers a profuse gallery of villains who are outside the circle of friends as the new doctrine “either with us or against us” opened by George Bush for the XXI century. This gallery includes from the very terrorists who justify the War on Terror (Ra's al Ghul, the Joker), to the “radical left” (Bane, Talia al Ghul) including liberal politicians (Harvey Dent), and corrupt that take advantage of the softness of the law to commit crimes with impunity (Dr. Crane, the Scarecrow).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This conference paper looks at evidence of 15th- and 16th-century saints' images on carved door frames at the church of S. Zanipolo (SS Giovanni e Paolo) in Venice, using them to help locate and reconstruct the history of the 'albergo' of the confraternity dedicated to St Peter Martyr and St Vincent Ferrer. Suggestions are made concerning the possible relationship of confraternity buildings outside a church to altars dedicated to the same saint(s) within that church.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Animals control contact with surfaces when locomoting, catching prey, etc. This requires sensorily guiding the rate of closure of gaps between effecters such as the hands, feet or jaws and destinations such as a ball, the ground and a prey. Control is generally rapid, reliable and robust, even with small nervous systems: the sensorimotor processes are therefore probably rather simple. We tested a hypothesis, based on general tau theory, that closing two gaps simultaneously, as required in many actions, might be achieved simply by keeping the taus of the gaps coupled in constant ratio. tau of a changing gap is defined as the time-to-closure of the gap at the current closure-rate. General tau theory shows that tau of a gap could, in principle, be directly sensed without needing to sense either the gap size or its rate of closure. In our experiment, subjects moved an effector (computer cursor) to a destination zone indicated on the computer monitor, to stop in the zone just as a moving target cursor reached it. The results indicated the subjects achieved the task by keeping tau of the gap between effector and target coupled to tau of the gap between the effector and the destination zone. Evidence of tau -coupling has also been found, for example, in bats guiding landing using echolocation. Thus, it appears that a sensorimotor process used by different species for coordinating the closure of two or more gaps between effecters and destinations entails constantly sensing the taus of the gaps and moving so as to keep the taus coupled in constant ratio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coherent anti-Stokes Raman scattering (CARS) microscopy has developed rapidly and is opening the door to new types of experiments. This work describes the development of new laser sources for CARS microscopy and their use for different applications. It is specifically focused on multimodal nonlinear optical microscopy—the simultaneous combination of different imaging techniques. This allows us to address a diverse range of applications, such as the study of biomaterials, fluid inclusions, atherosclerosis, hepatitis C infection in cells, and ice formation in cells. For these applications new laser sources are developed that allow for practical multimodal imaging. For example, it is shown that using a single Ti:sapphire oscillator with a photonic crystal fiber, it is possible to develop a versatile multimodal imaging system using optimally chirped laser pulses. This system can perform simultaneous two photon excited fluorescence, second harmonic generation, and CARS microscopy. The versatility of the system is further demonstrated by showing that it is possible to probe different Raman modes using CARS microscopy simply by changing a time delay between the excitation beams. Using optimally chirped pulses also enables further simplification of the laser system required by using a single fiber laser combined with nonlinear optical fibers to perform effective multimodal imaging. While these sources are useful for practical multimodal imaging, it is believed that for further improvements in CARS microscopy sensitivity, new excitation schemes are necessary. This has led to the design of a new, high power, extended cavity oscillator that should be capable of implementing new excitation schemes for CARS microscopy as well as other techniques. Our interest in multimodal imaging has led us to other areas of research as well. For example, a fiber-coupling scheme for signal collection in the forward direction is demonstrated that allows for fluorescence lifetime imaging without significant temporal distortion. Also highlighted is an imaging artifact that is unique to CARS microscopy that can alter image interpretation, especially when using multimodal imaging. By combining expertise in nonlinear optics, laser development, fiber optics, and microscopy, we have developed systems and techniques that will be of benefit for multimodal CARS microscopy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to show the type of media coverage done by the newspapers La Razón, El País and Público about the 15-M social movement during the time that the camping at Sol took place. Specifically, in terms of how the characterization of the “indignados” (outraged) got made. Based on our previous descriptive observations, we approached a visual analysis of the photographs published on the paper editions of those mainstream media from May 15-June 12 of the 2011. we started from a total sample of 379 items, developing:1) A content analysis of La Razón, El País, and Público; the most frequents words of each media, articles classifications from the reviews found on them (expositive, positive-evaluation, negative-evaluation).2) An analysis of the 408 images obtained from the total sample, which establishes a clear evolution of the “indignados” profile and how differently each media took the movement as such. That’s, when they stop naming them “indignados”, and recognize its nature as social movement by calling it: “Movimiento 15-M"...