965 resultados para diagnostic techniques and procedure
Resumo:
Throughout the alpine domain, shallow landslides represent a serious geologic hazard, often causing severe damages to infrastructures, private properties, natural resources and in the most catastrophic events, threatening human lives. Landslides are a major factor of landscape evolution in mountainous and hilly regions and represent a critical issue for mountainous land management, since they cause loss of pastoral lands. In several alpine contexts, shallow landsliding distribution is strictly connected to the presence and condition of vegetation on the slopes. With the aid of high-resolution satellite images, it's possible to divide automatically the mountainous territory in land cover classes, which contribute with different magnitude to the stability of the slopes. The aim of this research is to combine EO (Earth Observation) land cover maps with ground-based measurements of the land cover properties. In order to achieve this goal, a new procedure has been developed to automatically detect grass mantle degradation patterns from satellite images. Moreover, innovative surveying techniques and instruments are tested to measure in situ the shear strength of grass mantle and the geomechanical and geotechnical properties of these alpine soils. Shallow landsliding distribution is assessed with the aid of physically based models, which use the EO-based map to distribute the resistance parameters across the landscape.
Resumo:
The safety systems of nuclear power plants rely on low-voltage power, instrumentation and control cables. Inside the containment area, cables operate in harsh environments, characterized by relatively high temperature and gamma-irradiation. As these cables are related to fundamental safety systems, they must be able to withstand unexpected accident conditions and, therefore, their condition assessment is of utmost importance as plants age and lifetime extensions are required. Nowadays, the integrity and functionality of these cables are monitored mainly through destructive test which requires specific laboratory. The investigation of electrical aging markers which can provide information about the state of the cable by non-destructive testing methods would improve significantly the present diagnostic techniques. This work has been made within the framework of the ADVANCE (Aging Diagnostic and Prognostics of Low-Voltage I\&C Cables) project, a FP7 European program. This Ph.D. thesis aims at studying the impact of aging on cable electrical parameters, in order to understand the evolution of the electrical properties associated with cable degradation. The identification of suitable aging markers requires the comparison of the electrical property variation with the physical/chemical degradation mechanisms of polymers for different insulating materials and compositions. The feasibility of non-destructive electrical condition monitoring techniques as potential substitutes for destructive methods will be finally discussed studying the correlation between electrical and mechanical properties. In this work, the electrical properties of cable insulators are monitored and characterized mainly by dielectric spectroscopy, polarization/depolarization current analysis and space charge distribution. Among these techniques, dielectric spectroscopy showed the most promising results; by means of dielectric spectroscopy it is possible to identify the frequency range where the properties are more sensitive to aging. In particular, the imaginary part of permittivity at high frequency, which is related to oxidation, has been identified as the most suitable aging marker based on electrical quantities.
Resumo:
Recent advances in the fast growing area of therapeutic/diagnostic proteins and antibodies - novel and highly specific drugs - as well as the progress in the field of functional proteomics regarding the correlation between the aggregation of damaged proteins and (immuno) senescence or aging-related pathologies, underline the need for adequate analytical methods for the detection, separation, characterization and quantification of protein aggregates, regardless of the their origin or formation mechanism. Hollow fiber flow field-flow fractionation (HF5), the miniaturized version of FlowFFF and integral part of the Eclipse DUALTEC FFF separation system, was the focus of this research; this flow-based separation technique proved to be uniquely suited for the hydrodynamic size-based separation of proteins and protein aggregates in a very broad size and molecular weight (MW) range, often present at trace levels. HF5 has shown to be (a) highly selective in terms of protein diffusion coefficients, (b) versatile in terms of bio-compatible carrier solution choice, (c) able to preserve the biophysical properties/molecular conformation of the proteins/protein aggregates and (d) able to discriminate between different types of protein aggregates. Thanks to the miniaturization advantages and the online coupling with highly sensitive detection techniques (UV/Vis, intrinsic fluorescence and multi-angle light scattering), HF5 had very low detection/quantification limits for protein aggregates. Compared to size-exclusion chromatography (SEC), HF5 demonstrated superior selectivity and potential as orthogonal analytical method in the extended characterization assays, often required by therapeutic protein formulations. In addition, the developed HF5 methods have proven to be rapid, highly selective, sensitive and repeatable. HF5 was ideally suitable as first dimension of separation of aging-related protein aggregates from whole cell lysates (proteome pre-fractionation method) and, by HF5-(UV)-MALS online coupling, important biophysical information on the fractionated proteins and protein aggregates was gathered: size (rms radius and hydrodynamic radius), absolute MW and conformation.
Resumo:
Stabile Radikale haben in vielen Bereichen der Chemie, Physik, Biologie und Biomedizin ihren Nutzen unter Beweis gestellt. Gerade im letzten Jahrzehnt erlebte diese Substanzklasse vor allem wegen den Anwendungsmöglichkeiten von Nitroxiden als Red-Ox-Sensoren oder magnetischen Materialen ein erneutes Interesse. Das erste Kapitel beschäftigt sich mit der grundlegenden Theorie zur Entwicklung magnetischer Materialien. Des Weiteren sollen anhand einiger Beispiele Radikale im Komplex mit paragmagnetischen Metallen, Biradikale und Polyradikale beschrieben werden. rnrnIm zweiten Kapitel soll auf die Synthese von Hybrid Fluorophore-Nitrononyl-Nitroxid und Iminonitroxidradiale, sowie ihre Charakterisierung über IR, CV, EPR und Röntgenstrukturanalyse eingegangen werden. Mittels UV/Vis-Spektroskopie soll hierbei eine mögliche Anwendung als Red-Ox-Sensoren festgestellt werden. Hierbei werden über anschließende PL Untersuchungen eben diese Sensoreigenschaften der dargestellten Radikale bestätigt werden. Vielmehr noch soll die Möglichkeit von Pyren-Pyrazol-Nitronyl-Nitroxid als NO-Nachweis erläutert werden.rnrnFortschritte sowohl im Design als auch in der Analyse von magnetischen Materialen auf der Basis von Nitroxiden ist Thema des dritten Kapitels. Über ein klassisches Ullmann-Protokoll wurden verschiedene Nitronyl-Nitroxid und Iminonitroxid Biradiale mit unterschiedlichen π-Brücken zwischen den Radikalzentren synthetisiert. Magnetische Messungen belegen einen relativ starken antiferromagnetischen intramolekularen Austausch für den Großteil der untersuchten Biradikale. Hierbei zeigte sich jedoch eine außergewöhnliche hohe Austausch-Kupplung für 3,3‘-Diazatolandiradikale, die nur über die Existenz von starken intermolekularen Wechselwirkungen beschrieben werden kann. Durch Kombination der Röntgenstrukturanalyse mit DFT Berechnungen konnte im Fall des Tolan verbrückten Diradikals 87c die Intra-Dimer-Kupplung auf Jintra = -8,6 K bestimmt werden. Ein direkter Beweis für eine intermolekulare Anlagerung von Jinter ~- 2K konnte über eine Tieftemperatur AC-Messung von 87c erhalten werden. Bezüglich der magnetischen Messung ist das Nitronyl Biradikal 87c ein vielversprechender Kandidat für einen rein organischen eindimensionalen Quantenmagnet.rnrnAbsicht dieser Untersuchungen ist es zu zeigen, dass über die Kombination verschiedener struktureller Elemente die Sensitivität von Nitroxid basierten Sensoren und die intramolekulare Austauschwechselwirkung in π-konjugierten Spinsystemen so eingestellt werden kann, dass es möglich ist Moleküle mit gezielten Sensor- oder Magneteigenschaften zu entwickeln. rn
Resumo:
The increase in aquaculture operations worldwide has provided new opportunities for the transmission of aquatic viruses. The occurrence of viral diseases remains a significant limiting factor in aquaculture production and for the sustainability. The ability to identify quickly the presence/absence of a pathogenic organism in fish would have significant advantages for the aquaculture systems. Several molecular methods have found successful application in fish pathology both for confirmatory diagnosis of overt diseases and for detection of asymptomatic infections. However, a lot of different variants occur among fish host species and virus strains and consequently specific methods need to be developed and optimized for each pathogen and often also for each host species. The first chapter of this PhD thesis presents a complete description of the major viruses that infect fish and provides a relevant information regarding the most common methods and emerging technologies for the molecular diagnosis of viral diseases of fish. The development and application of a real time PCR assay for the detection and quantification of lymphocystivirus was described in the second chapter. It showed to be highly sensitive, specific, reproducible and versatile for the detection and quantitation of lymphocystivirus. The use of this technique can find multiple application such as asymptomatic carrier detection or pathogenesis studies of different LCDV strains. The third chapter, a multiplex RT-PCR (mRT-PCR) assay was developed for the simultaneous detection of viral haemorrhagic septicaemia (VHS), infectious haematopoietic necrosis (IHN), infectious pancreatic necrosis (IPN) and sleeping disease (SD) in a single assay. This method was able to efficiently detect the viral RNA in tissue samples, showing the presence of single infections and co-infections in rainbow trout samples. The mRT-PCR method was revealed to be an accurate and fast method to support traditional diagnostic techniques in the diagnosis of major viral diseases of rainbow trout.
Resumo:
Oggetto della tesi e' l'approfondimento su tecniche e metodiche di preservazione del polmone isolato per lo studio ecografico. E' discussa l'appropriatezza sull'uso degli ultrasuoni in corso di chirurgia mini invasiva polmonare, obiettivo di una ricerca sperimentale. Il razionale dello studio si fonda sull'indicazione all'exeresi chirurgica di noduli polmonari di diametro inferiore al centometro, ovvero di diametro superiore ma localizzati in aree centrali del polmone. Queste lesioni sono sempre piu' frequentente diagnosticate per mezzo di avanzate tecniche di imaging. L'atto chirurgico ha scopo terapeutico quando sia stata posta la diagnosi di neoplasia maligna, diagnostico-terapeutico quando non sia ancora ottenuta la tipizzazione istologica della lesione. La tecnica toracoscopica offre numerosi vantaggi rispetto alle tecniche chirurgiche tradizionali ma presenta il grave limite di non permettere la palpazione diretta del tessuto polmonare e la localizzazione della formazione tumorale quando essa non sia visibile macroscopicamente. Gli ultrasuoni sono stati utilizzati con successo per indirizzare la localizzazione del nodulo polmonare. Scopo dello studio sperimentale e' quello di confrontare tecniche diverse di preservazione del polmone isolato in un modello animale, comparando catatteristiche e prestazioni di sonde ecografiche differenti per tipologia. Del tutto recentemente, in ambito trapiantologico, sono state proposte tecniche di preservazione organica utili ai fini di uno studio anatomico sperimentale particolareggiato (EVLP) e moderna e' da considerarsi la concezione di mezzi tecnici specifici per la localizzazione di bersagli intrapolmonari. La tecnica clinica applicata allo studio del particolare ecografico, nel modello animale, ha reso comprensibile e meglio definito il ruolo delle sonde ecografiche nell'individuazione di forme tumorali suscettibili di exeresi definitiva.
Resumo:
The measurement of fluid volumes in cases of pericardial effusion is a necessary procedure during autopsy. With the increased use of virtual autopsy methods in forensics, the need for a quick volume measurement method on computed tomography (CT) data arises, especially since methods such as CT angiography can potentially alter the fluid content in the pericardium. We retrospectively selected 15 cases with hemopericardium, which underwent post-mortem imaging and autopsy. Based on CT data, the pericardial blood volume was estimated using segmentation techniques and downsampling of CT datasets. Additionally, a variety of measures (distances, areas and 3D approximations of the effusion) were examined to find a quick and easy way of estimating the effusion volume. Segmentation of CT images as shown in the present study is a feasible method to measure the pericardial fluid amount accurately. Downsampling of a dataset significantly increases the speed of segmentation without losing too much accuracy. Some of the other methods examined might be used to quickly estimate the severity of the effusion volumes.
Resumo:
The aim of this in vitro study was to assess the agreement among four techniques used as gold standard for the validation of methods for occlusal caries detection. Sixty-five human permanent molars were selected and one site in each occlusal surface was chosen as the test site. The teeth were cut and prepared according to each technique: stereomicroscopy without coloring (1), dye enhancement with rhodamine B (2) and fuchsine/acetic light green (3), and semi-quantitative microradiography (4). Digital photographs from each prepared tooth were assessed by three examiners for caries extension. Weighted kappa, as well as Friedman's test with multiple comparisons, was performed to compare all techniques and verify statistical significant differences. Results: kappa values varied from 0.62 to 0.78, the latter being found by both dye enhancement methods. Friedman's test showed statistical significant difference (P < 0.001) and multiple comparison identified these differences among all techniques, except between both dye enhancement methods (rhodamine B and fuchsine/acetic light green). Cross-tabulation showed that the stereomicroscopy overscored the lesions. Both dye enhancement methods showed a good agreement, while stereomicroscopy overscored the lesions. Furthermore, the outcome of caries diagnostic tests may be influenced by the validation method applied. Dye enhancement methods seem to be reliable as gold standard methods.
Resumo:
The purpose of this study was to demonstrate the improvement in diagnostic quality and diagnostic accuracy of SonoVue microbubble contrast-enhanced ultrasound (CE-US) versus unenhanced ultrasound imaging during the investigation of extracranial carotid or peripheral arteries. 82 patients with suspected extracranial carotid or peripheral arterial disease received four SonoVue doses (0.3 ml, 0.6 ml, 1.2 ml and 2.4 ml) with Doppler ultrasound performed before and following each dose. Diagnostic quality of the CE-US examinations was evaluated off-site for duration of clinically useful contrast enhancement, artefact effects and percentage of examinations converted from non-diagnostic to diagnostic. Accuracy, sensitivity and specificity were assessed as agreement of CE-US diagnosis evaluated by an independent panel of experts with reference standard modality. The median duration of clinically useful signal enhancement significantly increased with increasing SonoVue doses (p< or =0.002). At the dose of 2.4 ml of SonoVue, diagnostic quality evaluated as number of inconclusive examinations significantly improved, falling from 40.7% at baseline down to 5.1%. Furthermore, SonoVue significantly (p<0.01) increased the accuracy, sensitivity and specificity of assessment of disease compared with baseline ultrasound. SonoVue increases the diagnostic quality of Doppler images and improves the accuracy of both spectral and colour Doppler examinations of extracranial carotid or peripheral arterial disease.
Resumo:
AIMS: A registry mandated by the European Society of Cardiology collects data on trends in interventional cardiology within Europe. Special interest focuses on relative increases and ratios in new techniques and their distributions across Europe. We report the data through 2004 and give an overview of the development of coronary interventions since the first data collection in 1992. METHODS AND RESULTS: Questionnaires were distributed yearly to delegates of all national societies of cardiology represented in the European Society of Cardiology. The goal was to collect the case numbers of all local institutions and operators. The overall numbers of coronary angiographies increased from 1992 to 2004 from 684 000 to 2 238 000 (from 1250 to 3930 per million inhabitants). The respective numbers for percutaneous coronary interventions (PCIs) and coronary stenting procedures increased from 184 000 to 885 000 (from 335 to 1550) and from 3000 to 770 000 (from 5 to 1350), respectively. Germany was the most active country with 712 000 angiographies (8600), 249 000 angioplasties (3000), and 200 000 stenting procedures (2400) in 2004. The indication has shifted towards acute coronary syndromes, as demonstrated by rising rates of interventions for acute myocardial infarction over the last decade. The procedures are more readily performed and perceived safer, as shown by increasing rate of "ad hoc" PCIs and decreasing need for emergency coronary artery bypass grafting (CABG). In 2004, the use of drug-eluting stents continued to rise. However, an enormous variability is reported with the highest rate in Switzerland (70%). If the rate of progression remains constant until 2010 the projected number of coronary angiographies will be over three million, and the number of PCIs about 1.5 million with a stenting rate of almost 100%. CONCLUSION: Interventional cardiology in Europe is ever expanding. New coronary revascularization procedures, alternative or complementary to balloon angioplasty, have come and gone. Only stenting has stood the test of time and matured to the default technique. Facilitated access to PCI, more complete and earlier detection of coronary artery disease promise continued growth of the procedure despite the uncontested success of prevention.
Resumo:
AIMS: The experience of using radiofrequency ablation (RFA) for the treatment of arrhythmias in children and adolescents is still limited. This study aimed to review the most recent results of RF ablation in children and adolescents in a highly experienced centre with access to both conventional techniques and non-fluoroscopic electroanatomic mapping (CARTO). METHODS AND RESULTS: A total of 154 consecutive patients younger than 19 years treated with RFA during the period 2000-04 were included. Numbers (%) or median (quartiles) are reported. Age was 15 (12-17) years, 70 (45%) were males. Five patients (3%) had congenital heart disease. RFA was successful in 147/154 patients (95%). Arrhythmia recurrence occurred in 11 patients (7%). Procedure time was 55 (35-90) min and fluoroscopy time was 8.8 (4-19) min. Number of RF applications was 4 (2-10) and number of RF applications >20 s was 2 (1-7). One patient (0.7%) had complicating high-grade atrioventricular block. CARTO was used in 18 RF ablation procedures (11%) performed in 15 patients. CONCLUSION: RF ablation can be undertaken in children and adolescents with a high success rate, few recurrences and complications, very short procedure times, and acceptable fluoroscopy times. Non-fluoroscopic electroanatomic mapping is helpful in selected patients.
Resumo:
OBJECTIVE: To consider the reasons and context for test ordering by doctors when faced with an undiagnosed complaint in primary or secondary care. STUDY DESIGN AND SETTING: We reviewed any study of any design that discussed factors that may affect a doctor's decision to order a test. Articles were located through searches of electronic databases, authors' files on diagnostic methodology, and reference lists of relevant studies. We extracted data on: study design, type of analysis, setting, topic area, and any factors reported to influence test ordering. RESULTS: We included 37 studies. We carried out a thematic analysis to synthesize data. Five key groupings arose from this process: diagnostic factors, therapeutic and prognostic factors, patient-related factors, doctor-related factors, and policy and organization-related factors. To illustrate how the various factors identified may influence test ordering we considered the symptom low back pain and the diagnosis multiple sclerosis as examples. CONCLUSIONS: A wide variety of factors influence a doctor's decision to order a test. These are integral to understanding diagnosis in clinical practice. Traditional diagnostic accuracy studies should be supplemented with research into the broader context in which doctors perform their work.
Resumo:
Five diagnostic techniques performed on skin biopsies (shoulder region) and/or serum were compared for detection of bovine viral diarrhea virus infection in 224 calves 0-3 months of age, 23 calves older than 3 months but younger than 7 months, and 11 cattle older than 7 months. The diagnostic methods used were immunohistochemistry (IHC), 2 commercial antigen ELISAs, 1 commercial antibody ELISA, and real-time RT-PCR. Results of 249 out of 258 skin and serum samples were identical and correlated within the 3 antigen detection methods and the real-time RT-PCR used. Twenty-six of these 249 samples were BVDV-positive with all antigen detection methods and the real-time RT-PCR. Nine out of 258 samples yielding discordant results were additionally examined by RT-PCR, RT-PCR Reamplification (ReA), and antigen ELISA I on serum and by immunohistochemistry on formalin fixed and paraffin-embedded skin biopsies. Virus isolation and genotyping was performed as well on these discordant samples. In 3 cases, transiently infected animals were identified. Two samples positive by real-time RT-PCR were interpreted as false positive and were ascribed to cross-contamination. The antigen ELISA II failed to detect 2 BVDV-positive calves due to the presence of maternal antibodies; the cause of 2 false-positive cases in this ELISA remained undetermined. Only persistently infected animals were identified in skin samples by IHC or antigen ELISA I. The 3 antigen detection methods and the real-time RT-PCR used in parallel had a high correlation rate (96.5%) and similar sensitivity and specificity values.
Resumo:
ABSTRACT: Nanotechnology in its widest sense seeks to exploit the special biophysical and chemical properties of materials at the nanoscale. While the potential technological, diagnostic or therapeutic applications are promising there is a growing body of evidence that the special technological features of nanoparticulate material are associated with biological effects formerly not attributed to the same materials at a larger particle scale. Therefore, studies that address the potential hazards of nanoparticles on biological systems including human health are required. Due to its large surface area the lung is one of the major sites of interaction with inhaled nanoparticles. One of the great challenges of studying particle-lung interactions is the microscopic visualization of nanoparticles within tissues or single cells both in vivo and in vitro. Once a certain type of nanoparticle can be identified unambiguously using microscopic methods it is desirable to quantify the particle distribution within a cell, an organ or the whole organism. Transmission electron microscopy provides an ideal tool to perform qualitative and quantitative analyses of particle-related structural changes of the respiratory tract, to reveal the localization of nanoparticles within tissues and cells and to investigate the 3D nature of nanoparticle-lung interactions.This article provides information on the applicability, advantages and disadvantages of electron microscopic preparation techniques and several advanced transmission electron microscopic methods including conventional, immuno and energy-filtered electron microscopy as well as electron tomography for the visualization of both model nanoparticles (e.g. polystyrene) and technologically relevant nanoparticles (e.g. titanium dioxide). Furthermore, we highlight possibilities to combine light and electron microscopic techniques in a correlative approach. Finally, we demonstrate a formal quantitative, i.e. stereological approach to analyze the distributions of nanoparticles in tissues and cells.This comprehensive article aims to provide a basis for scientists in nanoparticle research to integrate electron microscopic analyses into their study design and to select the appropriate microscopic strategy.
Resumo:
The radiation burden of an individual patient caused by a radiological examination depends strongly on the technical parameters, such as kV and mAs. As an inquiry among 150 swiss physicians showed, rather different irradiation techniques are used for the same examination. Depending on these irradiation techniques, the doses may vary by almost a factor of ten. These large variations in dose indicate that in some clinics or hospitals the radiographic techniques and the film processing are at fault. This fact has to be accounted for by future efforts of quality assurance in diagnostic radiology.