948 resultados para diagnostic technique and procedure


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To describe the surgical technique and initial experience with a single-port retroperitoneal renal biopsy (SPRRB).Materials and Methods: Between January and April 2013, five children underwent SPRRB in our hospital. A single 1.5 cm incision was performed under the 12th rib at mid-axillary line, and an 11 mm trocar was inserted. A nephroscope was used to identify the kidney and dissect the perirenal fat. After lower pole exposure, a laparoscopic biopsy forceps was introduced through the nephroscope working channel to collect a renal tissue sample.Results: SPRRB was successfully performed in five children. The mean operative time was 32 minutes, and mean estimated blood loss was less than 10 mL. The hospital stay of all patients was two days because they were discharged in the second postoperative day, after remaining at strict bed rest for 24 hours after the procedure. The average number of glomeruli present in the specimen was 31.Conclusion: SPRRB is a simple, safe and reliable alternative to open and videolaparoscopic approaches to surgical renal biopsy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oral exfoliative cytology (EC) is a rapid and practical complementary test that can be used in the diagnosis of various diseases. The objectives of this study were to assess dentists'knowledge of EC and to disseminate information on the technique. The study included 240 dentists from the city of Anapolis (Goias, Brazil) who answered a questionnaire regarding demographic data and data relating to EC and who then received information on the technique. The data revealed that 26.92% of the dentists did not know about EC. Among those who reported knowledge of EC, 33.91% did not know the procedures for performing the technique, and 85.38% had no experience with EC. In addition, 54.09% of the answers regarding the instrument used to collect the material and 56.82% of the answers concerning suitable fixatives were inappropriate. Although 73.02% of the dentists adequately identified the pathologies for which EC is recommended, it was concluded that the respondents had poor knowledge of EC. There is a need to increase dentists'awareness of this subject and of EC's use in diagnostic practices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refractive and profilometric measurements of lenses were performed through holography with a photorefractive Bi12TiO20 crystal as the recording medium. Two properly aligned diode lasers emitting in the red region were employed as light sources. Both lasers were tuned in order to provide millimetric and sub-millimetric synthetic wavelengths. The surfaces of the test lens were covered by a 25-μm opaque plastic tape in order to allow the lens profilometry upon illuminating them with a collimated beam. The resulting holographic images appear covered by interference fringes corresponding to the wavefront geometry of the wave scattered by the lens. For refractive index measurement a diffusely scattering flat surface was positioned behind the uncovered lens which was also illuminated by a plane wave. The resulting contour interferogram describes the form of the wavefront after the beam traveled back and forth through the lens. The fringe quantitative evaluation was carried out through the four-stepping technique and the resulting phase map and the Branch-cut method was employed for phase unwrapping. The only non-optical procedure for lens characterization was the thickness measurement, made by a dial caliper. Exact ray tracing calculation was performed in order to establish a relation between the output wavefront geometry and the lens parameters like radii of curvature, thickness and refractive index. By quantitatively comparing the theoretical wavefront geometry with the experimental results relative uncertainties bellow 3% for refractive index and 1 % for focal length were obtained. © 2008 American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Temporomandibular joint arthrocentesis is a method of flushing out the synovial fluid that is currently performed by providing a double puncture to the upper joint space. The traditional 2-needle technique has some restrictions, such as the difficulty in performing it in the presence of intra-articular adherences and in the female patients, because the space is very small. The adoption of a single-needle for fluid injection might have some advantages with respect to the traditional 2-needle approach in terms of easily, time of execution and tolerability. We describe a single needle technique and we recommend the use.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of this study were to evaluate the effect of root canal filling techniques on root fracture resistance and to analyze, by finite element analysis (FEA), the expansion of the endodontic sealer in two different root canal techniques. Thirty single-rooted human teeth were instrumented with rotary files to a standardized working length of 14 mm. The specimens were embedded in acrylic resin using plastic cylinders as molds, and allocated into 3 groups (n=10): G(lateral) - lateral condensation; G(single-cone) - single cone; G(tagger) - Tagger's hybrid technique. The root canals were prepared to a length of 11 mm with the #3 preparation bur of a tapered glass fiber-reinforced composite post system. All roots received glass fiber posts, which were adhesively cemented and a composite resin core was built. All groups were subjected to a fracture strength test (1 mm/min, 45°). Data were analyzed statistically by one-way ANOVA with a significance level of 5%. FEA was performed using two models: one simulated lateral condensation and Tagger's hybrid technique, and the other one simulated the single-cone technique. The second model was designed with an amount of gutta-percha two times smaller and a sealer layer two times thicker than the first model. The results were analyzed using von Mises stress criteria. One-way ANOVA indicated that the root canal filling technique affected the fracture strength (p=0.004). The G(lateral) and G(tagger) produced similar fracture strength values, while G(single-cone) showed the lowest values. The FEA showed that the single-cone model generated higher stress in the root canal walls. Sealer thickness seems to influence the fracture strength of restored endodontically treated teeth.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Uncaria tomentosa is a medicinal plant used in folk medicine by Amazon tribes. In this study the constituents of aqueous extract of U. tomentosa bark were quantified by chromatographic technique and its lethal concentration 50 (48 h) in Hyphessobrycon eques was determined. The chromatography showed high levels of oxindole alkaloids, quinovic acid glycosides, and low molecular weight polyphenols. The CL50 48 h was 1816 mg/L. Fish showed behavior changes at concentrations above 2000 mg/L, accompanied by a significant decrease of dissolved oxygen. At the highest concentration 100% mortality was observed attributed to oxygen reduction by the amount of oxindole alkaloids, polyphenols accumulation of the extract in the gills, and the interaction of these compounds with dopamine. In conclusion, the aqueous extract of U. tomentosa did not alter the chemical components and it was shown that U. tomentosa has low toxicity to H. eques; therefore, it can be used safely in this species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Understanding the possible methodologies for the rapid and inexpensive identification of fungal infections is essential for disease diagnosis, but there are some limitations. To help with this problem, serological methods that detect antigens or antibodies are widely used and are useful for the diagnosis of paracoccidioidomycosis (PCM) through the detection of gp43, which is the main antigen employed for the immunodiagnosis of this disease caused by Paracoccidioides brasiliensis. However, the use of gp43 has become restricted because it was recently found that this marker is not identified in the infections caused by Paracoccidioides lutzii. Therefore, it is necessary to identify new antigens in both species or antigens specific for P. lutzii to decrease the morbidity and/or mortality associated with PCM. This review provides a discussion of new diagnostic challenges after the recent discoveries regarding the taxonomy of the Paracoccidioides genus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the impact of different disinfection solutions on flexural resistance of chemically-activated acrylic resin. Test pieces were made of clear acrylic resin using a rectangular mold and employing two techniques: wet polymerization under pressure (n = 20) and dry polymerization under pressure (n = 20). Test pieces were subdivided into four equal groups: distilled water (control), sodium bicarbonate, 1% sodium hypochlorite and effervescent ats. The 30-day cycling technique consisted of immersing the test pieces in 100 ml of solution for 10 min three times a day and placing them in closed containers containing artificial saliva at 37°C. Subsequently, the flexural resistance of samples was tested. Data were analyzed using two-way analysis of variance (ANOVA) with forces serving as the dependent variables and the polymerization technique and cleaning agents as independent variables. Post hoc multiple comparisons were performed using Tukey’s test. There was no statistically significant difference in the flexural strength between the two polymerization techniques. The greatest flexural strength was observed for the effervescent tablets group followed by the control and 1% sodium hypochlorite groups which were statistically similar. Thus, the sodium bicarbonate solution caused the lowest flexural resistance of the test pieces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Superficial stains and irregularities of the enamel are generally what prompt patients to seek dental intervention to improve their smile. These stains or defects may be due to hypoplasia, amelogenesis imperfecta, mineralized white spots, or fluorosis, for which enamel microabrasion is primarily indicated. Enamel microabrasion involves the use of acidic and abrasive agents, such as with 37% phosphoric acid and pumice or 6% hydrochloric acid and silica, applied to the altered enamel surface with mechanical pressure from a rubber cup coupled to a rotatory mandrel of a low-rotation micromotor. If necessary, this treatment can be safely combined with bleaching for better esthetic results. Recent studies show that microabrasion is a conservative treatment when the enamel wear is minimal and clinically imperceptible. The most important factor contributing to the success of enamel microabrasion is the depth of the defect, as deeper, opaque stains, such as those resulting from hypoplasia, cannot be resolved with microabrasion, and require a restorative approach. Surface enamel alterations that result from microabrasion, such as roughness and microhardness, are easily restored by saliva. Clinical studies support the efficacy and longevity of this safe and minimally invasive treatment. The present article presents the clinical and scientific aspects concerning the microabrasion technique, and discusses the indications for and effects of the treatment, including recent works describing microscopic and clinical evaluations.