904 resultados para detection method
Resumo:
Objective: In view of the considerable importance of venereal transmission of bovine leptospirosis, the objective of the present study was to compare the polymerase chain reaction (PCR), culture/isolation and serology to detect leptospire infection in bovine semen. Design: Blood for serologic examination and semen for bacterial culture and PCR were collected from 20 bulls at artificial insemination centres in Brazil. Each animal was sampled twice for serology. Result: Forty-five percent (9/20) of the serum samples collected showed agglutinin titers to serovar hardjo in the first sample and 25% (5/20) had agglutinin titers to serovar hardjo in the second sample. Eighty percent (16/20) of semen samples were positive by PCR. Leptospires could not be isolated from any of the semen samples examined. Conclusion: Polymerase chain reaction can be a method of great potential for the detection of leptospires at artificial insemination centres.
Resumo:
An antigen-competitive enzyme-linked immunosorbent assay (Ag-C-ELISA) was developed for the detection of infectious bronchitis virus (IBV) antigens, M41 strain, in tissues from experimentally infected chickens, or in allantoic fluid harvested from inoculated embryonated eggs. The detection limit of IBV in the Ag-C-ELISA was 104.1 median embryo infective doses (EID50)/well. Tracheal and lung samples from chickens vaccinated with 102.5 EID50 of live attenuated infectious bronchitis (H120) vaccine were negative in the direct detection Ag-C-ELISA. The results indicate that the Ag-C-ELISA has the potential to detect IBV, either directly in tissue samples or when combined with the passage of material in embryonated eggs, thereby constituting an alternative method for the diagnosis of IBV.
Resumo:
A rapid and sensitive method is described for the determination of clofentezine residues in apple, papaya, mango and orange. The procedure is based on the extraction of the sample with a hexane:ethyl acetate mixture (1:1, v/v) and liquid chromatographic analysis using UV detection. Mean recoveries from 4 replicates of fortified fruit samples ranged from 81% to 96%, with coefficients of variation from 8.9% to 12.5%. The detection and quantification limits of the method were of 0.05 and 0.1 mg kg-1, respectively.
Resumo:
Cell culture of Maytenus ilicifolia were established in order to produce and to quantify the antitumoral and antioxidant quinonemethide triterpenes. In vitro calli were induced from leaf explants of native plants and cultured in semi-solid medium under controlled conditions of humidity, temperature and photoperiod. The quinonemethide triterpenes showed maximum accumulation in the logarithmic phase growth of the cell culture. A rapid, sensitive and reliable reverse-phase HPLC method was used for quantitative determination of the antitumoral and antioxidant quinonemethide triterpenes, 22β-hydroxymaytenin and maytenin in callus of Maytenus ilicifolia. Well resolved peaks with good detection response and linearity in the range 1.0 - 100 μg/mL were obtained. This quantitative work was performed by an external standard method.
Resumo:
A simple, rapid, and sensitive spectrophotometric method for routine analysis of saccharin in commercial noncaloric sweeteners is proposed. This method is based on the reaction of saccharin with tetrachloro-p-benzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in an ethanol:acetone (4:1) medium, producing a violet-red compound (γ max = 550 nm). Beer's law is obeyed in a concentration range of 2.05 × 10 -4 to 3.00 × 10 -3 M with an excellent correlation coefficient (r = 0.9998). The detection limit was 1.55 × 10 -5 M, and the effect of interferences on the spectrophotometric measurements was evaluated. The proposed procedure was applied successfully to the determination of saccharin in noncaloric sweeteners. Recoveries were within 99.2-104.3% with standard deviations ranging from to 0.5-1.6%. Results of the proposed method compare very favorably with those given by the high-performance liquid chromatography method recommended by the Food and Drug Administration.
Resumo:
The aim of this paper was to apply a multiresidue method using Supercritical Fluid Extraction (SFE) and capillary gas chromatography with electron capture and mass spectrometry detections in the analysis of the levels of pesticide residues in fruits and vegetables. Single laboratory validation of both solid-liquid and supercritical fluid extraction methods was carried out for 32 compounds selected from four pesticide classes (organochlorine, organonitrogen, organophosphorus and pyretroid) in blank and fortified samples of fresh lettuce, potato, apple and tomato. Recoveries for the majority of pesticides from fortified samples at fortification level of 0.04-0.10 mg kg -1 ranged 74-96% for both methods and confirmation of pesticide identity was performed by gas-chromatography-mass spectrometry in a selected-ion monitoring mode. Both methods showed good limits of detection (less 0.01 mg kg-1, depending on the pesticide and matrix) and the SFE method minimized environmental concerns, time, and laboratory work. ©2005 Sociedade Brasileira de Química.
Resumo:
Piezoelectric actuators are widely used in positioning systems which demand high resolution such as scanning microscopy, fast mirror scanners, vibration cancellation, cell manipulation, etc. In this work a piezoelectric flextensional actuator (PFA), designed with the topology optimization method, is experimentally characterized by the measurement of its nanometric displacements using a Michelson interferometer. Because this detection process is non-linear, adequate techniques must be applied to obtain a linear relationship between an output electrical signal and the induced optical phase shift. Ideally, the bias phase shift in the interferometer should remain constant, but in practice it suffers from fading. The J1-J4 spectral analysis method provides a linear and direct measurement of dynamic phase shift in a no-feedback and no-phase bias optical homodyne interferometer. PFA application such as micromanipulation in biotechnology demands fast and precise movements. So, in order to operate with arbitrary control signals the PFA must have frequency bandwidth of several kHz. However as the natural frequencies of the PFA are low, unwanted dynamics of the structure are often a problem, especially for scanning motion, but also if trajectories have to be followed with high velocities, because of the tracking error phenomenon. So the PFA must be designed in such a manner that the first mechanical resonance occurs far beyond this band. Thus it is important to know all the PFA resonance frequencies. In this work the linearity and frequency response of the PFA are evaluated up to 50 kHz using optical interferometry and the J1-J4 method.
Resumo:
Indirect ELISA and IFAT have been reported to be more sensitive and specific than agglutination tests. However, MAT is cheaper, easier than the others and does not need special equipment. The purpose of this study was to compare an enzyme linked immunosorbent assay using crude rhoptries of Toxoplasma gondii as coating wells (r-ELISA) with indirect fluorescence antibody test (IFAT) and modified agglutination test (MAT) to detect anti-T. gondii antibodies in sera of experimentally infected pigs. Ten mixed breed pigs between 6.5 and 7.5 weeks old were used. All pigs were negative for the presence of T. gondii antibodies by IFAT (titre < 16), r-ELISA (OD < 0.295) and MAT (titre < 16). Animals received 7 × 107 viable tachyzoites of the RH strain by intramuscular (IM) route at day 0. Serum samples were collected at days -6, 0, 7, 14, 21, 28, 35, 42, 50, and 57. IFAT detected anti-T. gondii antibodies earlier than r-ELISA and MAT. The average of antibody levels was higher at day 35 in IFAT (Log10 = 2.9) and in MAT (Log10 = 3.5), and at day 42 in r-ELISA (OD = 0.797). The antibody levels remained high through the 57th day after inoculation in MAT, and there was a decrease tendency in r-ELISA and IFAT. IFAT was used as gold standard and r-ELISA demonstrated a higher prevalence (73.3%), sensitivity (94.3%), negative predictive value (83.3%), and accuracy (95.6%) than MAT. Kappa agreements among tests were calculated, and the best results were shown by r-ELISA × IFAT (κ = 0.88, p < 0.001). Cross-reaction with Sarcocystis miescheriana was investigated in r-ELISA and OD mean was 0.163 ± 0.035 (n = 65). Additionally, none of the animals inoculated with Sarcocystis reacted positively in r-ELISA. Our results indicate that r-ELISA could be a good method for serological detection of T. gondii infection in pigs. © 2005 Elsevier Inc. All rights reserved.
Resumo:
The detection of staphylococcal enterotoxins is decisive for the confirmation of an outbreak and for the determination of the enterotoxigenicity of strains. Since the recognition of their antigenicity, a large number of serological methods for the detection of enterotoxins in food and culture media have been proposed. Since immunological methods require detectable amounts of toxin, molecular biology techniques represent important tools in the microbiology laboratory. In the present study, polymerase chain reaction (PCR) was used to identify genes responsible for the production of enterotoxins and toxic shock syndrome toxin 1 (TSST-1) in S. aureus and coagulase-negative staphylococci (CNS) isolated from patients and the results were compared with those obtained by the reverse passive latex agglutination (RPLA) assay. PCR detection of toxin genes revealed a higher percentage of toxigenic S. aureus strains (46.7%) than the RPLA method (38.3%). Analysis of the toxigenic profile of CNS strains showed that 26.7% of the isolates produced some type of toxin, and one or more toxin-specific genes were detected in 40% of the isolates. These results suggests the need for further studies in order to better characterize the pathogenic potential of CNS and indicate that attention should be paid to the toxigenic capacity of this group of microorganisms.
Resumo:
The aim of this prospective study was to determine the DNA fragmentation levels before and after sperm preparation by layering method. A total of 78 patients submitted to assisted reproduction technology (ART) for infertility treatment were evaluated. Ejaculated spermatozoa were obtained by masturbation on the day of ART procedure. The evaluation of DNA fragmentation was performed in the fresh semen and after preparation by a layering method, respectively. After washing with PBS, the sperm pellets were smears and then processed for the terminal deoxyribonucleotidyl transferase (TdT)-mediated dUTP nick-end labelling (TUNEL) assay that was performed using a Cell Death Detection Kit with tetramethylrhodamine-labelled dUTP. For quantitative evaluation, 200 spermatozoa in randomly selected areas on microscope slides were evaluated and the percentage of TUNEL positive spermatozoa was determined. If ≥20% of selected sperm were TUNEL positive, the exam was considered abnormal. The mean percentage of DNA sperm fragmentation before sperm preparation was 17±8.3% and after 7.8±6.5% (p<0.0001). The exam was considered normal in 49 patients before preparation and in 73 patients after (p<0.0001). The sperm preparation with a layering method for the ART procedure is effective to select sperm with a significant decrease of the DNA damage.
Resumo:
This paper describes a simple, portable and environmentally friendly method for the rapid determination of dipyrone in pharmaceuticals by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound produced from the spot test reaction between dipyrone and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using a filter paper as solid support. Experimental design methodologies were used to optimize the measurement conditions. All reflectance measurements were carried out at 510 nm and the linear range was from 1.42 × 10-4-2.85 × 10-3 mol L-1, with a correlation coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 1.20 × 10-5 mol L-1 and 4.00 × 10-5 mol L-1, respectively. The intraday precision and interday precision were studied for 10 replicate analyses of 7.90 × 10-4 mol L-1 dipyrone solution. The coefficients of variation were 1.1 and 0.9%, respectively. The proposed method was applied successfully to the determination of dipyrone in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level. ©2007 Sociedade Brasileira de Química.
Resumo:
A simple, rapid and sensitive spectrophotometric method has been developed for the determination of methyldopa in pharmaceutical formulations. The method is based on the reaction between tetrachloro-p-benzoquinone (p-chloranil) and methyldopa, accelerated by hydrogen peroxide (H 2O 2), producing a violet-red compound (λmax = 535 nm) at ambient temperature (25.0 ± 0.2°C). Experimental design methodologies were used to optimize the measurement conditions. Beer's law is obeyed in a concentration range from 2.10 × 10 -4 to 2.48 × 10 -3 mol L -1 (r = 0.9997). The limit of detection was 7.55 × 10 -6 mol L -1 and the limit of quantification was 2.52 × 10 -5 mol L -1. The intraday precision and interday precision were studied for 10 replicate analyses of 1.59 × 10 -3 mol L -1 methyldopa solution and the respective coefficients of variation were 0.7 and 1.1%. The proposed method was successfully applied to the determination of methyldopa in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in the formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: The ability of biofilm formation seems to play an essential role in the virulence of coagulase-negative staphylococci (CNS). The most clearly characterized component of staphylococcal biofilms is the polysaccharide intercellular adhesin (PIA) encoded by the icaADBC operon. Biofilm production was studied in 80 coagulase-negative staphylococci (CNS) strains isolated from clinical specimens of newborns with infection hospitalized at the Neonatal Unit of the University Hospital, Faculty of Medicine of Botucatu, and in 20 isolates obtained from the nares of healthy individuals without signs of infection. The objective was to compare three phenotypic methods with the detection of the icaA, icaD and icaC genes by PCR. Findings: Among the 100 CNS isolates studied, 82% tested positive by PCR, 82% by the tube test, 81% by the TCP assay, and 73% by the CRA method. Using PCR as a reference, the tube test showed the best correlation with detection of the ica genes, presenting high sensitivity and specificity. Conclusions: The tube adherence test can be indicated for the routine detection of biofilm production in CNS because of its easy application and low cost and because it guarantees reliable results with excellent sensitivity and specificity. © 2010 Cunha et al; licensee BioMed Central Ltd.
Resumo:
A poly glutamic acid film modified electrode exhibited a catalytic response toguanosine oxidation potential and higher peak current value. Linear concentration curve was obtained in the concentration interval of 1.0 a 10.0 μmol L-1 in 0.04 mol L-1 B-R buffer pH 2.0 with a detection limit of 0.198 μmol L-1. The electrode was used for the determination of guanosine in the potential of +1.1 V (vs. Ag/AgCl) using differential pulse voltammetry (DPV) at urine sample with good recovery. © 2010 by CEE.