991 resultados para déficit de pressão de vapor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A reversible intermittent pow-injection procedure is proposed for the automated determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry, CVAAS. Solutions of sample and stannous chloride are carried by two air streams and sequentially injected into the generator/separator chamber in a segmented asynchronous merging zone configuration. The intermittent flow in the forward direction carries the mercury vapor through the flow cell, and in the backward direction, if aspirates the the remaining solution from the vessel to waste. We investigated composition and concentration of reagents, pow rates, commutation times, reactor configuration, and conditions for mercury release. The accuracy was checked by mercury determination in a certified sediment and spiked vinasses and river waters. The system handles about 100 samples per hour (0.50-5.00 mu g L-1), consuming ca. 2.5 mL of sample and 50 mg of SnCl2 per determination; Good recoveries (92-103%) were obtained with spiked samples. Results are precise (RSD <3% for 2.5 mu g Hg L-1, n = 12) and in agreement with values for certified reference material at 95% confidence level. (C) 1999 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new and fast procedure is proposed for cleaning autosampler cups using acid-vapor steam-cleaning with a miniaturized assembly in a microwave-heated sealed Teflon vessel. A glass cactus-shaped holder was made to support six polyethylene autosampler cups (volume, 2.0 mt) inside a 100 mt microwave vessel. Regent-grade nitric acid was added to the vessels, and the system was heated in a microwave oven for 5 min at 300 W. Chromium was determined by graphite-furnace atomic-absorption spectrophotometry. The blank values were lower with cleaned cups compared to untreated cups (i.e., as received from supplier). The quantification limits, estimated from detection limits established with Milli-Q water, were 0.66 and 0.95 mu g Cr L-1 for cleaned and untreated auto-sampler cups, respectively. (C) 1998 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moisture equilibrium data of pineapple pulp (PP) powders with and without additives - 18% maltodextrin (MD) or 18% gum Arabic (GA) - were determined at 20, 30, 40 and 50 degrees C by using the static gravimetric method in a water activity range of 0.06-0.90. The obtained isotherms were sigmoid, typical type 111, and the Guggenhein-Anderson-de Boer (GAB) model was fitted to the experimental data of equilibrium moisture content versus water activity. Addition of additives was shown to affect the isotherms in such a way that, at the same water activity, samples PP + GA and PP + MD presented lower equilibrium moisture content and were not so affected by varying temperature. The net isosteric heats of sorption of pulp powders with additives were higher (less negative) than those of pineapple pulp powders, suggesting that there are more active polar sites in the product without addition of GA or MD. An empirical exponential relationship could describe the heat of sorption dependence on the material moisture content. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin films were deposited by plasma enhanced chemical vapor deposition from titanium (IV) ethoxide (TEOT)-oxygen-helium mixtures. Actinometric optical emission spectroscopy was used to obtain the relative plasma concentrations of the species H, CH, O and CO as a function of the percentage of oxygen in the feed, R(ox). The concentrations of these species rise with increasing R(ox) and tend to fall for R(ox) greater than about 45%. As revealed by a strong decline in the emission intensity of the actinometer Ar as R(ox) was increased, the electron mean energy or density (or both) decreased as greater proportions of oxygen were fed to the chamber. This must tend to reduce gas-phase fragmentation of the monomer by plasma electrons. As the TEOT flow rate was fixed, however, and since the species H and CH do not contain oxygen, the rise in their plasma concentrations with increasing R(ox) is explained only by intermediate reactions involving oxygen or oxygen-containing species. Transmission infrared (IRS) and X-ray photoelectron (XPS) spectroscopies were employed to investigate film structure and composition. The presence of CH(2), CH(3), C=C, C-O and C=O groups was revealed by IRS. In addition, the presence of C-O and C=O groups was confirmed by XPS, which also revealed titanium in the +4 valence state. The Ti content of the films, however, was found to be much less than that of the monomer material itself. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The water restriction can damage the performance of crops, especially in the flowering period. Thus, the aim of this research was to evaluate the response of genotypes of wheat submitted to water deficit in the beginning of flowering. The experiment was conducted in greenhouse, in a completely randomized design, in factorial scheme 3 x 2, with five replications. The factors studied were: three wheat cultivars (Coodetec (CD) 105, 108 and 111) and 2 irrigation managements (with and without imposition of water deficit). During the period of water deficit imposition, gravimetric soil moisture and the relative content of water in leaf were evaluated, while at the moment of rehydration the biometric variables were determined. At the end of the crop cycle the components of production were evaluated. Reduction was found in the gravimetric soil moisture, in the relative levels of water and in all biometric variables, in function of the water deficit. The grain production showed difference only among the water regimes, in which the cultivar CD 111 is more efficient in the maintenance of the productive potential in conditions of water deficit, through the quick recovery in the relative content of water in leaves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diverse amorphous hydrogenated carbon and similar films containing additional elements were produced by Plasma Enhanced Chemical Vapor Deposition (PECVD) and by Plasma Immersion Ion Implantation and Deposition (PIIID). Thus a-C:H, a-C:H:F, a-C:H:N, a-C:H:Cl and a-C:H:O:Si were obtained, starting from the same feed gases, using both techniques. The same deposition system supplied with radiofrequency (RF) power was used to produce all the films. A cylindrical stainless steel chamber equipped with circular electrodes mounted horizontally was employed. RF power was fed to the upper electrode; substrates were placed on the lower electrode. For PIIID negative high tension pulses were also applied to the lower electrode. Raman spectroscopy confirmed that all the films are amorphous. Chemical characterization of each pair of films was undertaken using Infrared Reflection Absorption Spectroscopy and X-ray Photoelectron Spectroscopy. The former revealed the presence of specific structures, such as C-H, C-O, O-H. The latter allowed calculation of the ratio of hetero-atoms to carbon atoms in the films, e. g. F:C, N:C, and Si:C. Only relatively small differences in elemental composition were detected between films produced by the two methods. The deposition rate in PIIID is generally reduced in relation to that of PECVD; for a-C:H:Cl films the reduction factor is almost four.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of parietal cell vagotomy (PCV) on esophagogastric high pressure zone (HPZ) (pressure and length) was studied in 30 dogs. The animals were divided in 3 groups: group 1, 10 dogs submitted to PCV with gastric denervation until the esophagogastric junction; group 2, 10 dogs submitted to PCV with gastric denervation into esophagogastric junction and 3 cm above this; group 3 (control), 10 dogs submitted to laparotomy only. In the postoperative period (immediate and later) it wasn't observed any alteration of pressure and length of esophagogastric HPZ in three studied groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE--To provide a critical analysis of the fluid filled manometric system and M-mode echocardiography and, by their association, to standardize the determination of left ventricular (LV) pressure-diameter and stress-diameter relationships in humans. MATERIAL AND METHODS--The pressure curve and the LV M-mode image was obtained in 24 patients with cardiopathy. The dynamic characteristics of the fluid-filled system have been studied to define the amplitude, the resonance and the time gap of the pressure curve register. The delay of the pressure curve recording was determined in all cases by comparing pressure curve and echocardiographic aortic valve registers. The values of pressure, diameter, posterior wall thickness and LV meridional stress was calculated at every 0.02s. RESULTS--Preliminary analyses of the fluid-filled manometric system indicated that this system has variable dynamic characteristics. The pressure-diameter and stress-diameter loops obtained were similar to those of the literature. The values of end-systolic stress, percentage of fractional shortening, ejection fraction and circumferential fiber shortening rate of patients with dilated cardiomyopathy (n = 5) were significantly reduced when compared to the values of patients without left ventricular overload (n = 8) and patients with ventricular volume overload. It has been verified, also, that the retard of the pressure curve record introduced by the fluid-filled manometric system does not modify the values of these variables. CONCLUSION--The LV pressure-diameter and stress-diameter relationships obtained by the association of echocardiography and LV manometry showed functional characteristics of the ventricle that could not appear by the use of the echocardiography or by the LV manometry themselves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE--To analyze the influence of transient and sustained elevations of arterial pressure (AP) on the rate of rise of the left ventricular pressure (dp/dt). METHODS--Thirteen anesthetized, thoracotomized and mechanically ventilated dogs, submitted to pharmacological autonomic block (oxprenolol-3 mg/kg plus atropine-0.5 mg/kg). The AP elevation was obtained by mechanical constriction of the descending thoracic aorta. Two protocols were applied to all animals: Transient Arterial Hypertension (TAH) and Sustained Arterial Hypertension (SAH) and the following variables were evaluated: heart rate (HR), systolic (LVSP) and end diastolic (LVEDP) left ventricular pressure and dp/dt. In TAH the variables were analyzed in the basal condition (To) and at the maximal value of AP attained during the transient pressure elevation (TM). In the protocol SAH the variables were evaluated in the conditions: Control (Ho), hypertension 1 (H1) and hypertension 2 (H2). RESULTS--Considering all conditions, there were no significant differences among the values of HR. In the protocol TAH, the LVSP varied from 133 +/- 22 mmHg to 180 +/- 27 mmHg, whereas in SAH the values of LVSP were as follow: HO = 129 +/- 25 mmHg; H1 = 152 = 23 mmHg; H2 = 182 +/- 24 mmHg. LVEDP changed in both protocols: To = 7 +/- 2 mmHg; TM = 13 +/- 2 mmHg (p < 0.05); Ho = 7 +/- 2 mmHg; H1 = 10 +/- 2 mmHg; H2 = 14 +/- 3 mmHg (p < 0.05). During TAH there was no difference between the values of dp/dt (To = 3.303 +/- 598 mmHg/s; TM = 3.350 +/- 653 mmHg/s; p > 0.05), however, there were increases of the dp/dt during SAH (Ho = 3.233 +/- 576 mmHg/s; H1 = 3.831 +/- 667 mmHg/s; H1 = 4.594 +/- 833 mmHg/2; p < 0.05). CONCLUSION--The values of dp/dt are not influenced by transient elevation of AP. Sustained increase of AP activates cardiac adjustments, which results in elevation of dp/dt, by stimulation of contractile state. Probably, the inotropic intervention mechanism is the length dependent activation due to the Frank-Starling mechanism.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE--To analyze the influence of the myocardial engorgement due to coronary perfusion on the left ventricular diastolic pressure/volume (P/V) relations. METHODS--The study was undertaken in the isovolumic blood-perfused dog heart preparation (n = 7). The P/V relations were determined promoting ventricular volumes variations by steps of 2ml, in two conditions: during coronary perfusion pressure of 100mmHg and after occlusion of the perfusion line. RESULTS--It was verified that the P/V relations obtained without myocardial perfusion shifted to the down right in respect to the perfused heart. A exponential fitting of the P/V relations allows to conclude that there was no difference among the slopes of the curves obtained with and without perfusion. CONCLUSION--Our results indicated that coronary perfusion restrain the capacity of the left ventricle to receive blood, but there is no influence on the passive elastic stiffness of the chamber. This effect was taught to be consequence of the myocardial erectile property.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fabrication of boring tools (burrs) for dentistry with the use of a hot-filament chemical vapor deposition (CVD) system, to form the diamond abrading structure, is reported here. The diamond was synthesized from a methane/freon gas mixture diluted in hydrogen. Comparative drilling tests with conventional diamond burrs and the CVD diamond burrs in borosilicate glasses demonstrated a lifetime more than 20 times larger for the CVD diamond burrs. Also, heat flow experiments in dentine showed that the CVD diamond burrs induce temperature gradients of the same order as the conventional ones. These characteristics of the CVD diamond burrs are highly desirable for odontological applications where the burrs' lifetime and the low temperature processing are essential to the quality and comfort of the treatment. © 1996 American Institute of Physics.