987 resultados para body segment parameters
Resumo:
Wireless Body Area Network (WBAN) is the most convenient, cost-effective, accurate, and non-invasive technology for e-health monitoring. The performance of WBAN may be disturbed when coexisting with other wireless networks. Accordingly, this paper provides a comprehensive study and in-depth analysis of coexistence issues and interference mitigation solutions in WBAN technologies. A thorough survey of state-of-the art research in WBAN coexistence issues is conducted. The survey classified, discussed, and compared the studies according to the parameters used to analyze the coexistence problem. Solutions suggested by the studies are then classified according to the followed techniques and concomitant shortcomings are identified. Moreover, the coexistence problem in WBAN technologies is mathematically analyzed and formulas are derived for the probability of successful channel access for different wireless technologies with the coexistence of an interfering network. Finally, extensive simulations are conducted using OPNET with several real-life scenarios to evaluate the impact of coexistence interference on different WBAN technologies. In particular, three main WBAN wireless technologies are considered: IEEE 802.15.6, IEEE 802.15.4, and low-power WiFi. The mathematical analysis and the simulation results are discussed and the impact of interfering network on the different wireless technologies is compared and analyzed. The results show that an interfering network (e.g., standard WiFi) has an impact on the performance of WBAN and may disrupt its operation. In addition, using low-power WiFi for WBANs is investigated and proved to be a feasible option compared to other wireless technologies.
Resumo:
Wireless Body Area Networks (WBANs) have emerged as a promising technology for medical and non-medical applications. WBANs consist of a number of miniaturized, portable, and autonomous sensor nodes that are used for long-term health monitoring of patients. These sensor nodes continuously collect information of patients, which are used for ubiquitous health monitoring. In addition, WBANs may be used for managing catastrophic events and increasing the effectiveness and performance of rescue forces. The huge amount of data collected by WBAN nodes demands scalable, on-demand, powerful, and secure storage and processing infrastructure. Cloud computing is expected to play a significant role in achieving the aforementioned objectives. The cloud computing environment links different devices ranging from miniaturized sensor nodes to high-performance supercomputers for delivering people-centric and context-centric services to the individuals and industries. The possible integration of WBANs with cloud computing (WBAN-cloud) will introduce viable and hybrid platform that must be able to process the huge amount of data collected from multiple WBANs. This WBAN-cloud will enable users (including physicians and nurses) to globally access the processing and storage infrastructure at competitive costs. Because WBANs forward useful and life-critical information to the cloud – which may operate in distributed and hostile environments, novel security mechanisms are required to prevent malicious interactions to the storage infrastructure. Both the cloud providers and the users must take strong security measures to protect the storage infrastructure.
Resumo:
The anthropometric (body weight, height, upper arm circumference, triceps and subescapular skinfolds; Quetelet index and arm muscle circunference) and blood biochemistry (proteins and lipids) parameters were evaluated in 93 males and 27 females, 17-72 years old voluntaries living in the malarial endemic area of Humaita city (southwest Amazon). According to their malarial history they were assembled in four different groups: G1-controls without malarial history (n:30); G2 - controls with malarial history but without actual manifestation of the disease (n:40); G3 - patients with Plasmodium vivax (n:19) and G4 - patients with Plasmodium falciparum (n:31). The malarial status was stablished by clinical and laboratory findings. The overall data of anthropometry and blood biochemistry discriminated the groups differently. The anthropometric data were low sensitive and contrasted only the two extremes (G1>G4) whereas the biochemistry differentiated two big groups, the healthy (G1+G2) and the patients (G3+G4). The nutritional status of the P. falciparum patients was highly depressed for most of the studied indices but none was sensitive enough to differentiate this group from the P. vivax group (G3). On the other hand the two healthy groups could be differentiated through the levels of ceruloplasmin (G1
Resumo:
RESUMO: Contexto: Indicadores fidedignos da composição corporal são importantes na orientação das estratégias nutricionais de recém-nascidos e pequenos lactentes submetidos a cuidados intensivos. O braço é uma região acessível para avaliar a composição corporal regional, pela medida dos seus compartimentos. A antropometria e a ultrassonografia (US) são métodos não invasivos, relativamente económicos, que podem ser usados à cabeceira do paciente na medição desses compartimentos, embora esses métodos não tenham ainda sido validados neste subgrupo etário. A ressonância magnética (RM) pode ser usada como método de referência na validação da medição dos compartimentos do braço. Objectivo: Validar em lactentes pré-termo, as medidas do braço por antropometria e por US. Métodos: Foi estudada uma coorte de recém-nascidos admitidos consecutivamente na unidade de cuidados intensivos neonatais, com 33 semanas de idade de gestação e peso adequado para a mesma, sem anomalias congénitas major e não submetidas a diuréticos ou oxigenoterapia no momento da avaliação. Nas vésperas da alta, foram efectuadas medições do braço, com ocultação, pelos métodos antropométrico, ultrassonográfico e RM. As medidas antropométricas directas foram: peso (P), comprimento (C), perímetro cefálico (PC), perímetro braquial (PB) e prega cutânea tricipital (PT). As área braquial total, área muscular (AM) e área adiposa foram calculadas pelos métodos de Jeliffee & Jeliffee e de Rolland-Cachera. Utilizando uma sonda PSH-7DLT de 7 Hz no ecógrafo Toshiba SSH 140A foram medidos os perímetros braquial e muscular e calculadas automaticamente as áreas braquial e muscular, sendo a área adiposa obtida por subtracção. Como método de referência foi utilizada a RM – Philips Gyroscan ACS-NT, Power-Track 1000 ®, 1.5 Tesla com uma antena de quadratura do joelho. Na análise estatística foram utilizados os métodos paramétricos e não paramétricos, conforme adequado. Resultados: Foram incluídas 30 crianças, nascidas com ( ±DP) 30.7 ±1.9 semanas de gestação, pesando 1380 ±325g, as quais foram avaliadas às 35.4 ±1.1 semanas de idade corrigida, quando pesavam 1786 ±93g. Nenhuma das medidas antropométricas, individualmente, constitui um indicador aceitável (r2 <0.5) das medições por RM. A melhor e mais simples equação alternativa encontrada é a que estima a AM (r2 = 0.56), derivada dos resultados da análise de regressão múltipla: AMRM = (P x 0.17) + (PB x 5.2) – (C x 6) – 150, sendo o P expresso em g, o C e o PB em cm. Nenhuma das medidas ultrassonográficas constitui um indicador aceitável (r2 <0.4) das medições por RM. Conclusões: A antropometria e as medidas ultrassonográficas do braço não são indicadores fidedignos da composição corporal regional em lactentes pré-termo, adequados para a idade de gestação.----------ABSTRACT: Background: Accurate predictors for body composition are valuable tools guiding nutritional strategies in infants needing intensive care. The upper-arm is a part of the body that is easily accessible and convenient for assessing the regional body composition, throughout the assessment of their compartments. Anthropometry and by ultrasonography (US) are noninvasive and relatively nonexpensive methods for bedside assessment of the upper-arm compartments. However, these methods have not yet been validated in infants. Magnetic resonance imaging (MRI) may be used as gold standard to validate the measurements of the upper-arm compartments. Objective: To validate the upper-arm measurements by anthropometry and by US in preterm infants. Methods: A cohort of neonates consecutively admitted at the neonatal intensive care unit, appropriate for gestational age, with 33 weeks, without major congenital abnormalities and not subjected to diuretics or oxygen therapy, was assessed. Before the discharge, the upper-arm was blindly measured by anthropometry, US and MRI. The direct anthropometric parameters measured were: weight (W), length (L), head circumference (HC), mid-arm circumference (MAC), and tricipital skinfold thickness. The arm area (AA), arm muscle area (AMA) and arm fat area were calculated applying the methods proposed by Jeliffee & Jeliffee and by Rolland-Cachera. Using the sonolayer Toshiba SSH 140A and the probe PSH-7DLT 7Hz, the arm and muscle perimeters were measured by US, the arm and muscle areas included were automatically calculated, and the fat area was calculated by subtraction. The MR images were acquired on a 1.5-T Philips Gyroscan ACS-NT, Power-Track 1000 scanner, and a knee coil was chosen for the upper-arm measurements. For statistical analysis parametric and nonparametric methods were used as appropriate. Results: Thirty infants born with ( ±SD) 30.7 ±1.9 weeks of gestational age and weighing 1380 ±325g were included in the study; they were assessed at 35.4 ±1.1 weeks of corrected age, weighing 1786 ±93g. None of the anthropometric measurements are individually acceptable (r2 <0.5) for prediction of the measurements obtained by MRI. The best and simple alternative equation found is the equation for prediction of the AMA (r2 = 0.56), derived from the results of multiple regression analysis: AMARM = (W x 0.17) + (MAC x 5.2) – (L x 6) – 150, being the W expressed in g, and L and MAC in cm. None of the ultrasonographic measurements are acceptable (r2 <0.5) predictors for the measurements obtained by MRI. Conclusions: The measurements of the upper-arm by anthropometry and by US are not accurate predictors for the regional body composition in preterm appropriate for gestational age infants.
Resumo:
Demand response is an energy resource that has gained increasing importance in the context of competitive electricity markets and of smart grids. New business models and methods designed to integrate demand response in electricity markets and of smart grids have been published, reporting the need of additional work in this field. In order to adequately remunerate the participation of the consumers in demand response programs, improved consumers’ performance evaluation methods are needed. The methodology proposed in the present paper determines the characterization of the baseline approach that better fits the consumer historic consumption, in order to determine the expected consumption in absent of participation in a demand response event and then determine the actual consumption reduction. The defined baseline can then be used to better determine the remuneration of the consumer. The paper includes a case study with real data to illustrate the application of the proposed methodology.
Resumo:
Differences in virulence of strains of Entamoeba histolytica have long been detected by various experimental assays, both in vivo and in vitro. Discrepancies in the strains characterization have been arisen when different biological assays are compared. In order to evaluate different parameters of virulence in the strains characterization, five strains of E. histolytica, kept under axenic culture, were characterized in respect to their, capability to induce hamster liver abscess, erythrophagocytosis rate and cytopathic effect upon VERO cells. It was found significant correlation between in vitro biological assays, but not between in vivo and in vitro assays. Good correlation was found between cytopathic effect and the mean number of uptaken erythrocytes, but not with percentage of phagocytic amoebae, showing that great variability can be observed in the same assay, according to the variable chosen. It was not possible to correlate isoenzyme and restriction fragment pattern with virulence indexes since all studied strains presented pathogenic patterns. The discordant results observed in different virulence assays suggests that virulence itself may not the directly assessed. What is in fact assessed are different biological characteristics or functions of the parasite more than virulence itself. These characteristics or functions may be related or not with pathogenic mechanisms occurring in the development of invasive amoebic disease
Resumo:
Introduction: Increased fat mass is becoming more prevalent in women and its accumulation in the abdominal region can lead to numerous health risks such as diabetes mellitus. The clay body wrap using compounds such as green clay, green tea and magnesium sulfate, in addition to microcurrent, may reduce abdominal fat mass and minimize or prevent numerous health problems. Objective: This study aims at measuring the influence of the clay body wrap with microcurrent and aerobic exercise on abdominal fat. Methods: Nineteen female patients, randomized into intervention (n = 10) and control (n = 9) groups, were evaluated using ultrasound for visceral and subcutaneous abdominal fat, calipers and abdominal region perimeter for subcutaneous fat and bioimpedance for weight, fat mass percentage and muscular mass. During 10 sessions (5 weeks, twice a week) both groups performed aerobic exercise in a cycloergometer and a clay body wrap with microcurrent was applied to the intervention group. Results: When comparing both groups after 5 weeks of protocol, there was a significant decrease in the subcutane- ous fat around left anterior superior iliac spine in the intervention group (ρ = 0.026 for a confidence interval 95%). When comparing initial and final abdominal fat in the intervention group, measured by ultrasound (subcutaneous and visceral fat) and by skinfold (subcutaneous fat), we detected a significant abdominal fat reduction. Conclusion: This study demonstrated that the clay body wrap used with microcurrent and aerobic exercise can have a positive effect on central fat reduction.
Resumo:
Dairy foods comprise a range of products with varying nutritional content. The intake of dairy products (DPs) has been shown to have beneficial effects on body weight and body fat. This study aimed to examine the independent association between DP intake, body mass index (BMI), and percentage body fat (%BF) in adolescents. A cross-sectional, school-based study was conducted with 1,001 adolescents (418 boys), ages 15–18 years, from the Azorean Archipelago, Portugal. Anthropometric measurements were recorded (weight and height), and %BF was assessed using bioelectric impedance analysis. Adolescent food intake was measured using a self-administered, semiquantitative food frequency questionnaire. Data were analyzed separately for girls and boys, and separate multiple linear regression analysis was used to estimate the association between total DP, milk, yogurt, and cheese intake, BMI, and %BF, adjusting for potential confounders. For boys and girls, respectively, total DP consumption was 2.6 ± 1.9 and 2.9 ± 2.5 servings/day (P = 0.004), while milk consumption was 1.7 ± 1.4 and 2.0 ± 1.7 servings/day (P = 0.001), yogurt consumption was 0.5 ± 0.6 and 0.4 ± 0.7 servings/day (P = 0.247), and cheese consumption was 0.4 ± 0.6 and 0.5 ± 0.8 servings/day (P = 0.081). After adjusting for age, birth weight, energy intake, protein, total fat, sugar, dietary fiber, total calcium intake, low-energy reporters, parental education, pubertal stage, and physical activity, only milk intake was negatively associated with BMI and %BF in girls (respectively, girls: β = −0.167, P = 0.013; boys: β = −0.019, P = 0.824 and girls: β = −0.143, P = 0.030; boys: β = −0.051, P = 0.548). Conclusion: We found an inverse association between milk intake and both BMI and %BF only in girls.
Resumo:
Dissertação apresentada para a obtenção do Grau de Mestre em Genética Molecular e Biomedicina, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
The present study assessed the clinical significance of hepatitis C virus (HCV) genotypes and their influence on response to long term recombinant-interferon-alpha (r-IFN-a) therapy in Brazilian patients. One hundred and thirty samples from patients previously genotyped for the HCV and with histologically confirmed chronic hepatitis C (CH-C) were evaluated for clinical and epidemiological parameters (sex, age, time of HCV infection and transmission routes). No difference in disease activity, sex, age or mode and time of transmission were seen among patients infected with HCV types 1, 2 or 3. One hundred and thirteen of them were treated with 3 million units of r-IFN-a, 3 times a week for 12 months. Initial response (IR) was significantly better in patients with genotype 2 (100%) and 3 (46%) infections than in patients with genotype 1 (29%) (p < 0.005). Among subtypes, difference in IR was observed between 1b and 2 (p < 0.005), and between 1b and 3a (p < 0.05). Sustained response (SR) was observed in 12% for (sub)type 1a, 13% for 1b, 19% for 3a, and 40% for type 2; significant differences were found between 1b and 2 (p < 0.001), and between 1b and 3a (p < 0.05). Moreover, presence of cirrhosis was significantly associated with non response and response with relapse (p < 0.05). In conclusion, non-1 HCV genotype and lack of histological diagnosis of cirrhosis were the only baseline features associated with sustained response to treatment. These data indicate that HCV genotyping may have prognostic relevance in the responsiveness to r-IFN-a therapy in Brazilian patients with chronic HCV infection, as seen in other reports worldwide.
Resumo:
Esta dissertação apresenta o trabalho realizado no âmbito da unidade curricular de Tese/Dissertação (TEDI), do 2º ano, do Mestrado em Engenharia Eletrotécnica e de Computadores no ramo de Automação e Sistemas. O principal objetivo desta dissertação consiste no desenvolvimento de um sistema que permita efetuar a deteção de um determinado número de anomalias num sinal eletrocardiográfico. O coração é um dos órgãos mais importantes do corpo humano. É ele que recebe e bombeia o sangue pelo organismo. Isto é, recebe sangue pobre em oxigénio, encaminha-o para os pulmões onde será enriquecido em oxigénio. O sangue enriquecido em oxigénio é então encaminhado novamente para o coração que será enviado para todas as partes do corpo humano. O eletrocardiograma desempenha um papel fundamental de modo a diagnosticar eventuais anomalias no correto funcionamento do coração. Estas anomalias podem dever-se a diversos fatores como tabaco, colesterol, pressão sanguínea alta ou diabetes entre outros. As anomalias associadas ao ritmo cardíaco são denominadas de arritmias. As arritmias são fundamentalmente originadas pela alteração da frequência ou do ritmo cardíaco. Utilizando a lógica difusa, pretendeu-se desenvolver um sistema que fizesse a identificação de um determinado número de tipos de batimentos entre os quais: o bloqueio do ramo esquerdo (LBBB), bloqueio do ramo direito (RBBB), contração prematura ventricular (VPC) e contração prematura auricular (APC). Todos os desenvolvimentos efetuados, a nível de programação, são neste documento relatados de forma a constituírem um possível guia para a utilização deste tipo de sistemas. Mais ainda, descrevem-se nele toda a pesquisa efetuada e as alternativas de desenvolvimento selecionadas. O Sistema de Deteção de Arritmias (SDA) desenvolvido mostrou-se eficaz desde que o utilizador consiga identificar corretamente os parâmetros que lhe são pedidos. A interface gráfica desenvolvida permitiu também uma maior facilidade durante a análise do sinal eletrocardiográfico.
Resumo:
Introduction: Coronary artery disease and aging seems to be associated with a sedentary lifestyle, contributing to increased abdominal fat and consequently metabolic complications. The exercise can break this cycle by stimulating lipolysis and the use of fatty acids. In Europe there is still a lack of cardiac rehabilitation programmes in hospitals, therefore, this study aims to demonstrate the advantages of implementing home-based exercise programmes, as well as, their effects on cardiovascular prevention. This study analyzed the effects of a home-based exercise programme, in patients with coronary artery disease (myocardial infarction for 1 year), in body composition, abdominal fat, lipid profile. Methods: An ongoing randomized controlled trial with a sample of 20 participants were randomly allocated to intervention (n = 10) and control groups (n = 10). Intervention group performed a specific exercise programme during 8 weeks, consisting of ten home based exercises taking into account flexibility, muscle endurance and strength as well as cardiovascular endurance. Skinfolds thickness were measure to calculate the percentage of total fat: Skinfolds used were suprailiac, abdominal horizontal and vertical. Body mass index calculation and blood tests for lipidic profile were performed. Results: After eight weeks the intervention group decreased significantly the percentage of total fat (p < 0.05), the suprailiac skinfold (p < 0.05), the abdominal horizontal and vertical skinfold (p < 0.05) when compared with control group. In the intervention group it was observed after 8 weeks a significant decrease in body mass index, LDL-cholesterol and triglycerides. Conclusions: Home-based exercise programme influenced body composition, abdominal fat and lipid profile. These results highlight the importance of implementing home based exercises that are easy and cheap to implement in cardiac patients, in order to promote health and reduce cardiovascular risk factors.
Resumo:
The third-instar of an unidentified sarcophagid, recovered from a mummified body of a 32-yr-old Thai male was examined using scanning electron microscopy (SEM). Although the morphological features of this larva are similar to the other sarcophagid larvae, some features could be helpful for species identification, which is a basic requirement for estimation of postmortem interval in forensic investigation. These features included number and arrangement of papillae on the anterior spiracle, structure of spines, size of circumspiracular tubercles at caudal segment and branching peculiarity of the posterior spiracular hairs. This information could benefit future identification of the sarcophagid larvae that exist in Thailand.
Resumo:
IEEE International Conference on Communications (IEEE ICC 2015). 8 to 12, Jun, 2015, IEEE ICC 2015 - Communications QoS, Reliability and Modeling, London, United Kingdom.