934 resultados para barrier integrity
Resumo:
Purpose: To determine the feasibility of taking intra-ocular pressure (IOP) readings with Goldmann-type applanation tonometer probe covered with cling film to avoid transmission of Creutzfeldt-Jakob disease (CJD). Methods: Data were collected on two occasions from the right eyes of 30 healthy subjects using a Perkins applanation tonometer. On each occasion, a single tonometry measurement was made with and without cling film covering. Results: Cling film covering brought about a statistically significant IOP bias (-0.8 mmHg on first occasion and -1.17 mmHg on second occasion). The 95% limits of agreement, between readings made with and without cling film covering, were ±3.4 mmHg on first occasion; ±2.5 mmHg on second occasion. A statistically significant reduction of inter-sessional repeatability was observed for readings taken with cling film (±5.2 mmHg) compared to those made without (±3.9 mmHg). Conclusions: Even if the above findings are found to be acceptable, given the known intra-subject variations of this type of tonometry (±4 mmHg), ethical and legal considerations relating to the barrier properties of cling film are likely to prevent its routine use by optometrists. © 2004 The College of Optometrists.
Resumo:
Purpose: To determine the validity of covering a corneal contact transducer probe with cling film as protection against the transmission of Creutzfeldt-Jakob disease (CJD). Methods: The anterior chamber depth, lens thickness and vitreous chamber depth of the right eyes of 10 subjects was recorded, under cycloplegia, with and without cling film covering over the transducer probe of a Storz Omega Compu-scan Biometric Ruler. Measurements were repeated on two occasions. Results: Cling film covering did not influence bias or repeatability. Although the 95% limits of agreement between measurements made with and without cling film covering tended to exceed the intrasessional repeatability, they did not exceed the intersessional repeatability of measurements taken without cling film. Conclusions: The results support the use of cling film as a disposable covering for corneal contact A-scan ultrasonography to avoid the risk of spreading CJD from one subject to another. © 2003 The College of Optometrists.