948 resultados para anaerobic biodigestion
Resumo:
O objetivo deste estudo foi determinar, em mesatenistas bem treinados, as aptidões aeróbia e anaeróbia. Participaram do presente estudo oito mesatenistas brasileiros treinados do sexo masculino (18±2 anos). Os sujeitos foram submetidos a um teste incremental específico para determinação do consumo pico de oxigênio (VO2PICO), intensidade associada ao VO2PICO (iVO2PICO) e do ponto de compensação respiratório (PCR) e a dois testes de esforço repetitivo, sendo o teste de RAST e o índice anaeróbio alático (IAA), para determinação dos índices anaeróbios. O VO2PICO correspondeu a 50,5±4,4ml kg-1 min-1 , a iVO2PICO a 52,1±9,6 bolas min-1 e o PCR a 44,9±8,0 bolas min-1. No RAST, a potência pico (PP) e a potência média (PM) relativa corresponderam a 9,0±1,3W kg-1 e 7,0±0,9W kg-1, respectivamente, enquanto que o IAA foi 1,14±0,51 mM/m s-1 . Esses valores de VO2PICO e dos parâmetros anaeróbios quando comparados a valores de outros esportes com raquetes caracterizaram que mesatenistas brasileiros treinados apresentam potência aeróbia moderada e potência anaeróbia é baixa.
Resumo:
Although table tennis has a tradition lasting more than 100 years, relatively little is known about players' physiological requirements - especially during competition. In this review we discuss research studies that have led to our current understanding of how the body functions during table tennis training and competition and how this is altered by training. Match and practice analysis of the table tennis game indicates that during intense practice and competition it is predominantly the anaerobic alactic system that is called into play, while the endurance system is relied on to recovery the anaerobic stores used during such effort. It is thus important for coaches to keep in mind that, while the anaerobic alactic system is the most energetic system used during periods of exertion in a table tennis game, a strong capacity for endurance is what helps a player recover quicker for the following match and the next day of competition. This paper provides a review of specific studies that relate to competitive table tennis, and highlights the need for training and research programs tailored to table tennis. © Journal of Sports Science and Medicine.
Resumo:
Introduction: The literature lacks studies about lactate actions and some limitations in studies involving healthy individuals or patients with some metabolic disorder. Objectives: This study aimed to evaluate the protocol of double effort test for obese-induced rats. Methods: Fourteen male Wistar rats were divided into two groups: Control (Con) and Obese (Obe). The control group was fed with standard chow and water ad libitum. The obese group was fed with standard chow, water ad libitum and hyperlipidic diet. Twelve weeks after the beginning of the hyperlipidic diet, insulin tolerance test, Maximal Lactate Steady State (MLSS) test and the double efforts test were performed. Results: The diet was effective to promote obesity. The obese group decreased insulin sensitivity in approximately 19% (Con = 2.156 ± 0.1187 AU vs Obe = 1.742 ± 0.1551 AU). The lactate concentration and velocity of anaerobic threshold at MLSS test were 3.780 ± 0.09 mmol/L e 18 m.min-1 in both groups. The velocity of anaerobic threshold estimated by double efforts test was 15.59±0.653 m.min-1 in Con group control animals and 16.42±0.672 m.min-1 in Obe group. The double effort test underestimated around 13% and 8.7% the aerobic capacity in control and obese groups respectively, however, presented significant correlation with MLSS (r = 0,88; P < 0,0075 controls / r = 0,92; P < 0,0031 obese). Conclusion: So, the double effort test can be an interesting alternative to evaluate the aerobic capacity for both healthy sedentary and obese animals.
Resumo:
This study evaluated the ethanol addition as a strategy for start-up and acclimation of a pilot scale (1300 L) anaerobic sequencing batch biofilm reactor (AnSBBR) for the treatment of municipal landfill leachate with seasonal biodegradability variations. The treatment was carried out at ambient temperature (23.8 ± 2.1 °C) in the landfill area. In a first attempt, the leachate collected directly from landfill showed to be predominantly recalcitrant to anaerobic treatment and the acclimation was not possible. In a second attempt, adding ethanol to leachate, the reactor was successfully acclimated. After acclimation, without ethanol addition, the CODTotal influent ranged from 4970 to 13040 mg L-1 and the removal efficiencies ranged from 12.1% to 70.7%. A final test was carried out increasing the ammonia and free-ammonia concentration from 2486 mgN L-1 and 184 mgN L-1 to 4519 mgN L-1 and 634 mgN L-1, respectively, with no expressive inhibition verified. The start-up strategy was found to be feasible, providing the acclimation of the biomass in the AnSBBR, and maintaining the biomass active even when the leachate was recalcitrant. © 2013 Elsevier Ltd. All rights reserved.
Resumo:
The wastewater discharge produces impacts on receiving water bodies. Nutrients as P produce implications on lentic systems because they accelerate the eutrophication processes. Several technologies for P removal from the wastewater have been used: physic chemical treatment systems with important effects by coagulant products addition; biological processes based on anaerobic and aerobic conditions with great implications on the required volume; natural systems as stabilization ponds and irrigation require bigger areas and post-treatment processes. The aerobic fluidized bed reactors with internal circulation (AFBRIC) are compact options with high concentrations of active biomass that have demonstrated their capacity for organic matter and N removal. For sewage from the wastewater pumping station of Ilha Solteira city and effluents of a recirculation aquaculture system (RAS) for semi-intensive tilapia farming, the reactive P and total P removal efficiency in three AFBRIC with 250 mm external tube diameter and different internal tube diameter (ITD), for two different support media at different concentrations was evaluated. The average reactive P removal efficiency for domestic wastewater to hydraulic retention time (HRT) of 3 hours and 125 mm ITD reactor varied from 25,6 to 38,4% and with 150 mm ITD reactor varied from 27,5 to 32,5%; the average total P removal for the RAS wastewater at a HRT of 0,19 hours and 100 mm ITD was of 32,7%.
Resumo:
The purpose of this study was to quantify energy expenditure (EE) during multiple sets of leg press (LP) and bench press (BP) exercises in 10 males with at least 1 yr of resistance training (RT). The subjects underwent two sessions to determine 1 repetition maximum (1RM) on the BP and LP and one protocol consisting of a warm up and 4 sets for 10 repetitions at 70% 1RM with a 3-min rest period between sets for each exercise. Energy expenditure was calculated as the sum of oxygen uptake (aerobic component), EPOC, and lactate production (anaerobic component). There were no significant differences in EE between exercises for sets 1 to 4 and the total energy expended. However, statistical analysis revealed a significant difference (P<0.05) between exercises in RT economy (BP, 0.0206 ± 0.0044 kcal·kg-1 vs. LP, 0.0051 ± 0.0015 kcal·kg-1). Within exercise comparison showed set 4 was significantly different from sets 1 and 3 for BP, and for LP a significant difference was found between set 4 and sets 1, 2 and 3. Our results point to an increase in EE during multiple sets at 70% 1RM and show that in spite of the difference in muscle mass involved and total work done during each type of exercise, EE was not different due to greater economy during the LP.
Resumo:
The purpose of this study was to validate the lactate minimum test as a specific aerobic evaluation protocol for table tennis players. Using the frequency of 72 balls·min-1 for 90 sec, an exercise-induced metabolic acidosis was determined in 8 male table tennis players. The evaluation protocol began with a frequency of 40 balls·min-1 followed by an increase of 8 balls·min-1 every 3 min until exhaustion. The mean values that corresponded to the subjects' lactate minimum (Lacmin) were equal to 53.1 ± 1.5 balls·min-1 [adjusted for the time test (Lacmin_time)] and 51.6 ± 1.6 balls·min-1 [adjusted for the frequency of balls (Lacmin_Freq)], which resulted in a high correlation between the two forms of adjustment (r = 0.96 and (P = 0.01). The mean maximum lactate steady state (MLSS) was 52.6 ± 1.6 balls·min-1. Pearson's correlations between Lacmin_time vs. MLSS and Lacmin_freq vs. MLSS were statistically significant (P = 0.03 and r = 0.86, P = 0.03 and r = 0.85, respectively). These findings indicate that the Lacmin test predicts MLSS. Therefore, it is an excellent method to obtain the athletes' anaerobic threshold. Also, there is the advantage that it can be performed in 1 day in the game area. However, the Lacmin value does not depend on the Lacpeak value.
Validação do glicosímetro portátil para avaliação, prescrição e monitoramento do treinamento aeróbio
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Pós-graduação em Fisioterapia - FCT
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)