972 resultados para acquired toxoplasmosis
Resumo:
Subtractive imaging in confocal fluorescence light microscopy is based on the subtraction of a suitably weighted widefield image from a confocal image. An approximation to a widefield image can be obtained by detection with an opened confocal pinhole. The subtraction of images enhances the resolution in-plane as well as along the optic axis. Due to the linearity of the approach, the effect of subtractive imaging in Fourier-space corresponds to a reduction of low spatial frequency contributions leading to a relative enhancement of the high frequencies. Along the direction of the optic axis this also results in an improved sectioning. Image processing can achieve a similar effect. However, a 3D volume dataset must be acquired and processed, yielding a result essentially identical to subtractive imaging but superior in signal-to-noise ratio. The latter can be increased further with the technique of weighted averaging in Fourier-space. A comparison of 2D and 3D experimental data analysed with subtractive imaging, the equivalent Fourier-space processing of the confocal data only, and Fourier-space weighted averaging is presented. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
Trata do financiamento e do gasto público com a política de assistência social no município de Vitória - ES, nos oito anos seguintes à publicação da Política Nacional de Assistência Social 2004. Constitui-se em um estudo de caso, onde se realizou revisão bibliográfica e pesquisa documental utilizando-se como fontes de dados o Sistema Municipal Ferramenta Operacional de Controle Orçamentário, os Planos Municipais de Assistência Social, os Planos Plurianuais de Aplicação e outras leis e resoluções municipais. Apresenta considerações sobre a trajetória da assistência social, especialmente a partir da Constituição Federal de 1988. Discute aspectos da política fiscal, do orçamento público, da Lei de Responsabilidade Fiscal e do financiamento e gasto da União com a assistência social. Por fim, debruça-se sobre a experiência do Município de Vitória - ES. Neste trabalho, a assistência social é compreendida como uma das formas de intervenção estatal, no sentido de garantir as condições de reprodução da sociedade capitalista, seja contribuindo para a acumulação de capital seja respondendo as reivindicações dos trabalhadores. Como resultados desta pesquisa foi possível identificar avanços e limites no financiamento e no gasto com a política de assistência social no município, dentre os quais destacam-se, de um lado, a ampliação dos recursos da assistência social em valores reais e o protagonismo do município no financiamento da política, de outro, a manutenção e/ou redução do percentual de gastos em relação às despesas gerais do município e o insuficiente aporte de recursos para fazer avançar a assistência social na direção da ampliação e da qualificação dos serviços.
Resumo:
A retinocoroidite é a manifestação mais comum causada pela infecção congênita por Toxoplasma gondii. Devido a gravidade das lesões oculares que podem até levar à perda completa da visão, a detecção precoce da toxoplasmose congênita e da lesão ocular são essenciais para o tratamento. Este trabalho possuiu o objetivo de avaliar a aplicabilidade da pesquisa de anticorpos IgG e das subclasses IgG1, IgG2, IgG3 e IgG4 anti-T. gondii por citometria de fluxo como marcador laboratorial das diferentes formas de lesões retinocoroidais na toxoplasmose congênita. Foram analisadas 88 amostras de soro de recém-nascidos com toxoplasmose congênita, sendo 25 sem lesão ocular (SL), 10 com lesão ocular ativa (RA), 26 com lesão ocular ativa e cicatricial (RAC) e 27 com lesão ocular cicatricial (RC). Foram também utilizadas 19 amostras de soro de recém-nascidos não infectados que apresentaram IgG positivo após o nascimento (NI). Essas amostras foram obtidas a partir de soros de recémnascidos participantes de um programa de triagem neonatal realizado em Minas Gerais realizado nos anos de 2006 e 2007. Os resultados demonstraram que os recém-nascidos com toxoplasmose congênita apresentam maior reatividade de anticorpos IgG total e subclasses IgG1, IgG2 e IgG3 do que indivíduos não infectados. No grupo não infectado, o único anticorpo com mais de 50% de indivíduos com alta reatividade de anticorpos foi IgG4. Ao comparar os grupos de indivíduos com toxoplasmose congênita, foi observado que o grupo RAC, seguido de RC, apresentou maior reatividade principalmente para os anticorpos IgG1 e IgG3 comparado aos recém-nascidos dos grupos RA e SL, enquanto que pacientes do grupo RA apresentaram maior reatividade para IgG4 do que indivíduos dos outros grupos. IgG1 foi a única subclasse capaz de diferenciar os grupos NI, SL dos grupos RAC e RC. Também foi avaliado o índice de avidez de IgG total, que não permitiu estabelecer nenhum critério de diferenciação das formas de lesão ocular causadas pelo T. gondii. Portanto, a citometria de fluxo demonstrou que pode ser um método laboratorial complementar para ser utilizado como indicador das diferentes lesões oculares causadas pela toxoplasmose congênita.
Resumo:
Novas ferramentas de Tecnologias Assistivas (TAs) têm aparecido ultimamente. Um exemplo são os Ambientes Virtuais (AVs), os quais são importantes para o desenvolvimento de novas TAs, que podem ser direcionadas para promoverem uma melhor qualidade de vida de pessoas com mobilidade reduzida permanente ou promover a reabilitação de pessoas com deficiência motora temporária. Outras ferramentas, que surgiram há algumas décadas com o desenvolvimento dos computadores, também ajudam no tratamento de pessoas com deficiência motora, que são as Interfaces Humano-Máquina (IHM). Utilizando em conjunto com equipamentos que capturam sinais biológicos, como equipamentos de Eletromiografia (EMG) e Eletroencefalografia (EEG), essas ferramentas se configuram como canais de comunicações entre o ser humano e os computadores, diferentemente das comumente utilizadas. Isso abre uma gama de possibilidades para sua utilização no tratamento e na assistência de pessoas com deficiência motora, onde sinais EMG podem ser utilizados para controlar próteses robóticas; e sinais EEG, quando capturados da região do córtex motor, podem ser utilizados em neuroreabilitação. Por outro lado, quando capturados na região occipital, os sinais de EEG podem ser utilizados para gerar comandos e outras finalidades. Este trabalho apresenta o desenvolvimento de novas ferramentas para auxiliar em pesquisas de TAs envolvendo sinais biológicos. Três diferentes AVs foram desenvolvidos para auxiliar nesse tipo de pesquisa. Além deles, um equipamento EEG comercial foi adaptado para ser utilizado com uma IHM, o qual utiliza dois desses três AVs desenvolvidos. Como resultados, temos a utilização bem sucedida do equipamento EEG obtido com sua utilização com SSVEP e Imaginação motora, além da implementação com sucesso dos três AVs desenvolvidos, que estão disponíveis para download gratuito, e que podem ser utilizados em demais pesquisas envolvendo TAs.
Resumo:
Esta dissertação objetiva analisar as compreensões dos profissionais da educação dos anos finais do Ensino Fundamental e do Ensino Médio da rede estadual dos municípios Guarapari, Nova Venécia, Viana e Vitória, sobre os seus processos de formação inicial e continuada na interface com as dimensões constitutivas da identidade e das condições de trabalho docente, a partir do banco de dados do Espírito Santo relativos à pesquisa “Trabalho Docente na Educação Básica no Brasil”, realizada em 2009, em sete Estados, incluído este, sob a coordenação geral do Grupo de Estudos sobre Políticas Educacionais e Trabalho Docente da Universidade Federal de Minas Gerais. A hipótese em discussão é que as políticas públicas educacionais implantadas no Espírito Santo nas últimas décadas têm promovido mudanças nas dimensões constitutivas da identidade e das condições de trabalho docente e também na formação dos profissionais da educação, implicando a baixa participação desses sujeitos em atividades e programas de formação continuada. Trata-se de um estudo quali-quantitativo no qual a metodologia consiste no intercruzamento dos dados coletados pelo survey da referida pesquisa, indicadores da identidade, perfil e condição de trabalho docente com os indicadores de formação. Os dados produzidos dialogaram com a produção teórica dos interlocutores Dubar, Nóvoa, Oliveira, Tardif e, Tardif, Lessard, além do aporte proveniente dos autores contemplados na revisão de literatura. Os resultados deste estudo indicam que a participação dos sujeitos da amostra em processos de formação continuada foi ainda menos expressiva do que a constatada no Espírito Santo e no Brasil, e que a centralidade adquirida pelo professor e seus processos de formação inicial e continuada não significou valorização profissional e condições adequadas de trabalho tidas como dimensões indissociáveis e igualmente importantes para alçar melhoria na qualidade da Educação Básica, a exemplo da predominância de baixos salários, apesar de a maioria dos participantes ser pós-graduada, do trabalho em mais de duas unidades educacional e da falta de apoio/orientação para o trabalho com alunos com necessidades especiais. Esses resultados vão de encontro às compreensões dos professores visto que, embora eles tenham reconhecido o seu papel como fundamental, não consideraram “receber mais” “capacitação para a atividade que exerce” entre as três medidas mais importantes para melhorar a qualidade do trabalho.
Resumo:
This paper aims to describe the processes of teaching illustration and animation, together, in the context of a masters degree program. In Portugal, until very recently, illustration and animation higher education courses, were very scarce and only provided by a few private universities, which offered separated programs - either illustration or animation. The MA in Illustration and Animation (MIA) based in the Instituto Politécnico do Cávado e Ave in Portugal, dared to join these two creative areas in a common learning model and is already starting it’s third edition with encouraging results and will be supported by the first international conference on illustration and animation (CONFIA). This masters program integrates several approaches and techniques (in illustration and animation) and integrates and encourages creative writing and critique writing. This paper describes the iterative process of construction, and implementation of the program as well as the results obtained on the initial years of existence in terms of pedagogic and learning conclusions. In summary, we aim to compare pedagogic models of animation or illustration teaching in higher education opposed to a more contemporary and multidisciplinary model approach that integrates the two - on an earlier stage - and allows them to be developed separately – on the second part of the program. This is based on the differences and specificities of animation (from classic techniques to 3D) and illustration (drawing the illustration) and the intersection area of these two subjects within the program structure focused on the students learning and competencies acquired to use in professional or authorial projects.
Resumo:
The success of artificial prosthetic replacements depends on the fixation of the artificial prosthetic component after being implanted in the thighbone. The materials for fixation are subject to mechanical stresses, which originate permanent deformations, incipient cracks and even fatigue fractures. This work shows the possibility of monitoring the mechanical stress over time in prosthesis. In this way, highly sensitive silicon thin-film piezoresistive sensors were developed attached to prosthesis and their results compared with commercial strain gauge sensors. Mechanical stress-strain experiments were performed in compressive mode, during 10,000 cycles. Experimental data was acquired at mechanical vibration frequencies of 0.5 Hz, 1 Hz and 5 Hz, and sent to a computer by means of a wireless link. The results show that there is a decrease in sensitivity of the thin-film silicon piezoresistive sensors when they are attached to the prosthesis, but this decrease does not compromise its monitoring performance. The sensitivity, compared to that of commercial strain gauges, is much larger due to their higher gauge factors (-23.5), when compared to the GFs of commercial sensors (2).
Resumo:
Pectus excavatum is the most common congenital deformity of the anterior thoracic wall. The surgical correction of such deformity, using Nuss procedure, consists in the placement of a personalized convex prosthesis into sub-sternal position to correct the deformity. The aim of this work is the CT-scan substitution by ultrasound imaging for the pre-operative diagnosis and pre-modeling of the prosthesis, in order to avoid patient radiation exposure. To accomplish this, ultrasound images are acquired along an axial plane, followed by a rigid registration method to obtain the spatial transformation between subsequent images. These images are overlapped to reconstruct an axial plane equivalent to a CT-slice. A phantom was used to conduct preliminary experiments and the achieved results were compared with the corresponding CT-data, showing that the proposed methodology can be capable to create a valid approximation of the anterior thoracic wall, which can be used to model/bend the prosthesis
Resumo:
Pectus excavatum is the most common congenital deformity of the anterior chest wall, in which an abnormal formation of the rib cage gives the chest a caved-in or sunken appearance. Today, the surgical correction of this deformity is carried out in children and adults through Nuss technic, which consists in the placement of a prosthetic bar under the sternum and over the ribs. Although this technique has been shown to be safe and reliable, not all patients have achieved adequate cosmetic outcome. This often leads to psychological problems and social stress, before and after the surgical correction. This paper targets this particular problem by presenting a method to predict the patient surgical outcome based on pre-surgical imagiologic information and chest skin dynamic modulation. The proposed approach uses the patient pre-surgical thoracic CT scan and anatomical-surgical references to perform a 3D segmentation of the left ribs, right ribs, sternum and skin. The technique encompasses three steps: a) approximation of the cartilages, between the ribs and the sternum, trough b-spline interpolation; b) a volumetric mass spring model that connects two layers - inner skin layer based on the outer pleura contour and the outer surface skin; and c) displacement of the sternum according to the prosthetic bar position. A dynamic model of the skin around the chest wall region was generated, capable of simulating the effect of the movement of the prosthetic bar along the sternum. The results were compared and validated with patient postsurgical skin surface acquired with Polhemus FastSCAN system
Resumo:
Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor
Resumo:
This paper proposes a wireless EEG acquisition platform based on Open Multimedia Architecture Platform (OMAP) embedded system. A high-impedance active dry electrode was tested for improving the scalp- electrode interface. It was used the sigma-delta ADS1298 analog-to-digital converter, and developed a “kernelspace” character driver to manage the communications between the converter unit and the OMAP’s ARM core. The acquired EEG signal data is processed by a “userspace” application, which accesses the driver’s memory, saves the data to a SD-card and transmits them through a wireless TCP/IP-socket to a PC. The electrodes were tested through the alpha wave replacement phenomenon. The experimental results presented the expected alpha rhythm (8-13 Hz) reactiveness to the eyes opening task. The driver spends about 725 μs to acquire and store the data samples. The application takes about 244 μs to get the data from the driver and 1.4 ms to save it in the SD-card. A WiFi throughput of 12.8Mbps was measured which results in a transmission time of 5 ms for 512 kb of data. The embedded system consumes about 200 mAh when wireless off and 400 mAh when it is on. The system exhibits a reliable performance to record EEG signals and transmit them wirelessly. Besides the microcontroller-based architectures, the proposed platform demonstrates that powerful ARM processors running embedded operating systems can be programmed with real-time constrains at the kernel level in order to control hardware, while maintaining their parallel processing abilities in high level software applications.
Resumo:
The main objectives of this investigation is to analyze the disclosure of information about intangible assets during a period of nine years, namely the extension or level, as well as their evolution and possible alterations verified upon them, that derived from the adoption in 2005, of the international norm in order to elaborate the consolidated accounts of banks. Through the verification of the disclosure of intangible assets. Taking into account items from International Accounting Standard (IAS) 38 from the International Accounting Standards Board (IASB), the consolidated financial statements from seventeen banks, presenting consolidated accounts in Portugal uninterruptable between 2001 and 2009 were analyzed. The results obtained through the construction of an index, elaborated from this effected, reveled an average of disclosure of information on intangibles of 0.24 during the period. The level of general disclosure evolved from an average of 0.1940 in 2001 to 0.2778 in the year 2009. The intangibles generated internally had an average of disclosure of 0.1592 and the intangibles acquired had an average value of 0.2927. A growth in the extension of disclosure of intangibles upon the consolidated financial statement of banks during period analyzed, being this growth more accentuated in 2005 and 2006, which correspond to the first years of adoption in Portugal of international norm endorsed by the European Union through the Regalement 1606/2002, of July 19, the designed IASB-UE norms.
Resumo:
Pectus Carinatum (PC) is a chest deformity consisting on the anterior protrusion of the sternum and adjacent costal cartilages. Non-operative corrections, such as the orthotic compression brace, require previous information of the patient chest surface, to improve the overall brace fit. This paper focuses on the validation of the Kinect scanner for the modelling of an orthotic compression brace for the correction of Pectus Carinatum. To this extent, a phantom chest wall surface was acquired using two scanner systems – Kinect and Polhemus FastSCAN – and compared through CT. The results show a RMS error of 3.25mm between the CT data and the surface mesh from the Kinect sensor and 1.5mm from the FastSCAN sensor.
Resumo:
Pectus excavatum is the most common deformity of the thorax and usually comprises Computed Tomography (CT) examination for pre-operative diagnosis. Aiming at the elimination of the high amounts of CT radiation exposure, this work presents a new methodology for the replacement of CT by a laser scanner (radiation-free) in the treatment of pectus excavatum using personally modeled prosthesis. The complete elimination of CT involves the determination of ribs external outline, at the maximum sternum depression point for prosthesis placement, based on chest wall skin surface information, acquired by a laser scanner. The developed solution resorts to artificial neural networks trained with data vectors from 165 patients. Scaled Conjugate Gradient, Levenberg-Marquardt, Resilient Back propagation and One Step Secant gradient learning algorithms were used. The training procedure was performed using the soft tissue thicknesses, determined using image processing techniques that automatically segment the skin and rib cage. The developed solution was then used to determine the ribs outline in data from 20 patient scanners. Tests revealed that ribs position can be estimated with an average error of about 6.82±5.7 mm for the left and right side of the patient. Such an error range is well below current prosthesis manual modeling (11.7±4.01 mm) even without CT imagiology, indicating a considerable step forward towards CT replacement by a 3D scanner for prosthesis personalization.
Resumo:
The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.