944 resultados para Weighted MRI


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanism of contrast enhancement of tumors using magnetic resonance imaging was investigated in MCF7 human breast cancer implanted in nude mice. Dynamic contrast-enhanced images recorded at high spatial resolution were analyzed by an image analysis method based on a physiological model, which included the blood circulation, the tumor, the remaining tissues, and clearance via the kidneys. This analysis enabled us to map in rapidly enhancing regions within the tumor, the capillary permeability factor (capillary permeability times surface area per voxel volume) and the fraction of leakage space. Correlation of these maps with T2-weighted spin echo images, with histopathology, and with immunohistochemical staining of endothelial cells demonstrated the presence of dense permeable microcapillaries in the tumor periphery and in intratumoral regions that surrounded necrotic loci. The high leakage from the intratumoral permeable capillaries indicated an induction of a specific angiogenic process associated with stress conditions that cause necrosis. This induction was augmented in tumors responding to tamoxifen treatment. Determination of the distribution and extent of this stress-induced angiogenic activity by contrast-enhanced MRI might be of diagnostic and of prognostic value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gadolinium(III) texaphyrin (Gd-tex2+) is representative of a new class of radiation sensitizers detectable by magnetic resonance imaging (MRI). This porphyrin-like complex has a high electron affinity [E1/2 (red.) approximately = -0.08 V versus normal hydrogen electrode] and forms a long-lived pi-radical cation upon exposure to hydrated electrons, reducing ketyl radicals, or superoxide ions. Consistent with these chemical findings, Gd-tex2+ was found to be an efficient radiation sensitizer in studies carried out with HT29 cells in in vitro as well as in in vivo single and multifraction irradiation studies with a murine mammary carcinoma model. Selective localization of Gd-tex2+ in tumors was confirmed by MRI scanning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a 9.4 T MRI instrument, we have obtained images of the mouse brain response to photic stimulation during a period between deep anesthesia and the early stages of arousal. The large image enhancements we observe (often >30%) are consistent with literature results extrapolated to 9.4 T. However, there are also two unusual aspects to our findings. (i) The visual area of the brain responds only to changes in stimulus intensity, suggesting that we directly detect operations of the M visual system pathway. Such a channel has been observed in mice by invasive electrophysiology, and described in detail for primates. (ii) Along with the typical positive response in the area of the occipital portion of the brain containing the visual cortex, another area displays decreased signal intensity upon stimulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A lesão do plexo braquial é considerada a alteração neural mais grave das extremidades. A principal causa é o trauma de alta energia, especialmente acidentes envolvendo veículos a motor. Por este motivo, as lesões traumáticas do plexo braquial são cada vez mais frequentes. O presente estudo avaliou a acurácia da ressonância magnética (RM) no diagnóstico das lesões traumáticas do plexo braquial no adulto, utilizando o achado intraoperatório como padrão-ouro. Também foi avaliada a acurácia da neurografia pesada em difusão (neurografia DW) em relação à RM convencional e a capacidade de diferenciação dos três tipos de lesão: avulsão, ruptura e lesão em continuidade. Trinta e três pacientes com história e diagnóstico clínico de lesão traumática do plexo braquial foram prospectivamente estudados por RM. Os achados obtidos pela RM sem e com o uso da neurografia DW, e os achados de exame clínico foram comparados com os achados intraoperatórios. A análise estatística foi feita com associação de significância de 5%. Observou-se alta correlação entre a RM com neurografia DW e a cirurgia (rs=0,79), e baixa correlação entre a RM convencional e a cirurgia (rs=0,41). A correlação interobservador foi maior para a RM com neurografia DW (rs = 0,94) do que para a RM sem neurografia DW (rs = 0,75). Os resultados de sensibilidade, acurácia e valor preditivo positivo foram acima de 95% para as RM com e sem neurografia DW no estudo de todo o plexo. As especificidades foram, em geral, maiores para a neurografia DW (p < 0,05). Em relação à diferenciação dos tipos de lesão, a RM com neurografia DW apresentou altas acurácias e sensibilidades no diagnóstico da avulsão/rotura, e alta especificidade no diagnóstico da lesão em continuidade. A acurácia da RM (93,9%) foi significativamente maior que a do exame clínico (76,5%) no diagnóstico das lesões de todo o plexo braquial (p < 0,05).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let vv be a weight sequence on ZZ and let ψ,φψ,φ be complex-valued functions on ZZ such that φ(Z)⊂Zφ(Z)⊂Z. In this paper we study the boundedness, compactness and weak compactness of weighted composition operators Cψ,φCψ,φ on predual Banach spaces c0(Z,1/v)c0(Z,1/v) and dual Banach spaces ℓ∞(Z,1/v)ℓ∞(Z,1/v) of Beurling algebras ℓ1(Z,v)ℓ1(Z,v).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we utilise a novel approach to segment out the ventricular system in a series of high resolution T1-weighted MR images. We present a brain ventricles fast reconstruction method. The method is based on the processing of brain sections and establishing a fixed number of landmarks onto those sections to reconstruct the ventricles 3D surface. Automated landmark extraction is accomplished through the use of the self-organising network, the growing neural gas (GNG), which is able to topographically map the low dimensionality of the network to the high dimensionality of the contour manifold without requiring a priori knowledge of the input space structure. Moreover, our GNG landmark method is tolerant to noise and eliminates outliers. Our method accelerates the classical surface reconstruction and filtering processes. The proposed method offers higher accuracy compared to methods with similar efficiency as Voxel Grid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The African cichlid Oreochromis mossambicus (Mozambique tilapia) has been used as a model system in a wide range of behavioural and neurobiological studies. The increasing number of genetic tools available for this species, together with the emerging interest in its use for neurobiological studies, increased the need for an accurate hodological mapping of the tilapia brain to supplement the available histological data. The goal of our study was to elaborate a three-dimensional, high-resolution digital atlas using magnetic resonance imaging, supported by Nissl staining. Resulting images were viewed and analysed in all orientations (transverse, sagittal, and horizontal) and manually labelled to reveal structures in the olfactory bulb, telencephalon, diencephalon, optic tectum, and cerebellum. This high resolution tilapia brain atlas is expected to become a very useful tool for neuroscientists using this fish model and will certainly expand their use in future studies regarding the central nervous system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

alphawgt computes the Cronbach's alpha statistic. It is the same than the official alpha (version 4.5.2, 09apr2002) except that fweights and aweights may be applied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The neuro-anatomical substrates of major depressive disorder (MDD) are still not well understood, despite many neuroimaging studies over the past few decades. Here we present the largest ever worldwide study by the ENIGMA (Enhancing Neuro Imaging Genetics through Meta-Analysis) Major Depressive Disorder Working Group on cortical structural alterations in MDD. Structural T1-weighted brain magnetic resonance imaging (MRI) scans from 2148 MDD patients and 7957 healthy controls were analysed with harmonized protocols at 20 sites around the world. To detect consistent effects of MDD and its modulators on cortical thickness and surface area estimates derived from MRI, statistical effects from sites were meta-analysed separately for adults and adolescents. Adults with MDD had thinner cortical gray matter than controls in the orbitofrontal cortex (OFC), anterior and posterior cingulate, insula and temporal lobes (Cohen’s d effect sizes: −0.10 to −0.14). These effects were most pronounced in first episode and adult-onset patients (>21 years). Compared to matched controls, adolescents with MDD had lower total surface area (but no differences in cortical thickness) and regional reductions in frontal regions (medial OFC and superior frontal gyrus) and primary and higher-order visual, somatosensory and motor areas (d: −0.26 to −0.57). The strongest effects were found in recurrent adolescent patients. This highly powered global effort to identify consistent brain abnormalities showed widespread cortical alterations in MDD patients as compared to controls and suggests that MDD may impact brain structure in a highly dynamic way, with different patterns of alterations at different stages of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Contrast-enhanced (ce) fluid-attenuated inversion recovery magnetic resonance imaging (FLAIR MRI) has recently been shown to identify leptomeningeal pathology in multiple sclerosis. OBJECTIVE To demonstrate leptomeningeal enhancement on three-dimensional (3D) FLAIR in a case of Susac's syndrome. METHODS Leptomeningeal enhancement was correlated with clinical activity over 20 months and compared to retinal fluorescein angiography. RESULTS The size, number, and location of leptomeningeal enhancement varied over time and generally correlated with symptom severity. The appearance was remarkably similar to that of retinal vasculopathy. CONCLUSION Ce 3D FLAIR may aid in diagnosis and understanding of pathophysiology in Susac's syndrome and may serve as a biomarker for disease activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Individual analysis of functional Magnetic Resonance Imaging (fMRI) scans requires user-adjustment of the statistical threshold in order to maximize true functional activity and eliminate false positives. In this study, we propose a novel technique that uses radiomic texture analysis (TA) features associated with heterogeneity to predict areas of true functional activity. Scans of 15 right-handed healthy volunteers were analyzed using SPM8. The resulting functional maps were thresholded to optimize visualization of language areas, resulting in 116 regions of interests (ROIs). A board-certified neuroradiologist classified different ROIs into Expected (E) and Non-Expected (NE) based on their anatomical locations. TA was performed using the mean Echo-Planner Imaging (EPI) volume, and 20 rotation-invariant texture features were obtained for each ROI. Using forward stepwise logistic regression, we built a predictive model that discriminated between E and NE areas of functional activity, with a cross-validation AUC and success rate of 79.84% and 80.19% respectively (specificity/sensitivity of 78.34%/82.61%). This study found that radiomic TA of fMRI scans may allow for determination of areas of true functional activity, and thus eliminate clinician bias.