992 resultados para VESSEL PHANTOM
Resumo:
Stimulated echoes are widely used for imaging functional tissue parameters such as diffusion coefficient, perfusion, and flow rates. They are potentially interesting for the assessment of various cardiac functions. However, severe limitations of the stimulated echo acquisition mode occur, which are related to the special dynamic properties of the beating heart and flowing blood. To the well-known signal decay due to longitudinal relaxation and through-plane motion between the preparation and the read-out period of the stimulated echoes, additional signal loss is often observed. As the prepared magnetization is fixed with respect to the tissue, this signal loss is caused by the tissue deformation during the cardiac cycle, which leads to a modification of the modulation frequency of the magnetization. These effects are theoretically derived and corroborated by phantom and in vivo experiments.
Resumo:
Spatial-temporal regulation of bone morphogenetic protein (BMP) and Wnt activity is essential for normal cardiovascular development, and altered activity of these growth factors causes maldevelopment of the cardiac outflow tract and great arteries. In the present study, we show that SOST, a Dan family member reported to antagonize BMP and Wnt activity, is expressed within the medial vessel wall of the great arteries containing smooth muscle cells. The ascending aorta, aortic arch, brachiocephalic artery, common carotids, and pulmonary trunk were all associated with SOST expressing smooth muscle cells, while the heart itself, including the valves, and more distal arteries, that is, pulmonary arteries, subclavian arteries, and descending aorta, were negative. SOST was expressed from embryonic day 15.5 up to the neonatal period. SOST expression, however, did not correspond with inhibition of Smad-dependent BMP activity or beta-catenin-dependent Wnt activity in the great arteries. Activity of both signaling pathways was already down-regulated before induction of SOST expression.
Resumo:
Las características principales de las redes de cerco artesanales anchoveteras para CHD (PS 01.1.0 “ISSCFG”), utilizan tamaños de malla en el copo y cuerpo de ½” ~ 13 mm de material nylon Poliamida (PA). Se encontró una diferencia en las dimensiones, el material y diámetro del hilo del paño usado, entre las redes de las ANC-CHD tradicionales (Paita, Chimbote, Callao e Ilo) que utilizan paños anchoveteros de R310tex, R381tex R462tex, con longitud de relinga superior (LRS) de 183-366 m (100 a 200 bz), altura de paño estirado (AHE) de 27 a 64 m (15 a 35 bz); y las redes de cerco ANC-Pisco que utilizan paños anchoveteros de R155tex y R230tex, con LRS de 270 a 396 m (145 a 215 bz) y AHE de 30 m (16 bz). Del análisis regresional experimental, las principales características de la red (LRS, AHE), y la embarcación–capacidad de bodega-(CBOD) presentaron correlaciones significativas para la flota ANC-Tradicional (r = 0,86 y 0,91), mientras que en la flota ANC-Pisco las correlación de la función CBODLRS fue de 0,30 y la AHE fue constante (30 m) para todo el rango de LRS (270 - 396 m).
Resumo:
BACKGROUND: Three-dimensional (3D) navigator-gated and prospectively corrected free-breathing coronary magnetic resonance angiography (MRA) allows for submillimeter image resolution but suffers from poor contrast between coronary blood and myocardium. Data collected over >100 ms/heart beat are also susceptible to bulk cardiac and respiratory motion. To address these problems, we examined the effect of a T2 preparation prepulse (T2prep) for myocardial suppression and a shortened acquisition window on coronary definition. METHODS AND RESULTS: Eight healthy adult subjects and 5 patients with confirmed coronary artery disease (CAD) underwent free-breathing 3D MRA with and without T2prep and with 120- and 60-ms data-acquisition windows. The T2prep resulted in a 123% (P<0. 001) increase in contrast-to-noise ratio (CNR). Coronary edge definition was improved by 33% (P<0.001). Acquisition window shortening from 120 to 60 ms resulted in better vessel definition (11%; P<0.001). Among patients with CAD, there was a good correspondence with disease. CONCLUSIONS: Free-breathing, T2prep, 3D coronary MRA with a shorter acquisition window resulted in improved CNR and better coronary artery definition, allowing the assessment of coronary disease. This approach offers the potential for free-breathing, noninvasive assessment of the major coronary arteries.
Resumo:
BACKGROUND: The long-term incidence of stent thrombosis (ST) and complications after sirolimus-eluting stents (SES) implantation is still a matter of debate. METHOD: We conducted a systematic follow-up on the day of their 5-year SES implantation anniversary, in a series of consecutive real-world patients treated with a SES. The use of SES implantation was not restricted to "on-label" indications, and target lesions included in-stent restenosis, vein graft, left main stem locations, bifurcations, and long lesions. The Academic Research Consortium criteria were used for ST classification. RESULTS: Three hundred fifty consecutive patients were treated with SES between April and December 2002 in 3 Swiss hospitals. Mean age was 63 +/- 6 years, 78% were men, 20% presented with acute coronary syndrome, and 19% were patients with diabetes. Five-year follow-up was obtained in 98% of eligible patients. Stent thrombosis had occurred in 12 patients (3.6%) [definite 6 (1.8%), probable 1 (0.3%) and possible 5 (1.5%)]. Eighty-one percent of the population was free of complications. Major adverse cardiac events occurred in 74 (21%) patients and were as follows: cardiac death 3%, noncardiac death 4%, myocardial infarction 2%, target lesion revascularization 8%, non-target lesion revascularization target vessel revascularization 3%, coronary artery bypass graft 2%. Non-TVR was performed in 8%. CONCLUSION: Our data confirm the good long-term outcome of patients treated with SES. The incidence of complications and sub acute thrombosis at 5 years in routine clinical practice reproduces the results of prospective randomized trials.
Resumo:
We present an open-source ITK implementation of a directFourier method for tomographic reconstruction, applicableto parallel-beam x-ray images. Direct Fourierreconstruction makes use of the central-slice theorem tobuild a polar 2D Fourier space from the 1D transformedprojections of the scanned object, that is resampled intoa Cartesian grid. Inverse 2D Fourier transform eventuallyyields the reconstructed image. Additionally, we providea complex wrapper to the BSplineInterpolateImageFunctionto overcome ITKâeuro?s current lack for image interpolatorsdealing with complex data types. A sample application ispresented and extensively illustrated on the Shepp-Loganhead phantom. We show that appropriate input zeropaddingand 2D-DFT oversampling rates together with radial cubicb-spline interpolation improve 2D-DFT interpolationquality and are efficient remedies to reducereconstruction artifacts.
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
The occurrence of microvascular and small macrovascular lesions and Alzheimer's disease (AD)-related pathology in the aging human brain is a well-described phenomenon. Although there is a wide consensus about the relationship between macroscopic vascular lesions and incident dementia, the cognitive consequences of the progressive accumulation of these small vascular lesions in the human brain are still a matter of debate. Among the vast group of small vessel-related forms of ischemic brain injuries, the present review discusses the cognitive impact of cortical microinfarcts, subcortical gray matter and deep white matter lacunes, periventricular and diffuse white matter demyelinations, and focal or diffuse gliosis in old age. A special focus will be on the sub-types of microvascular lesions not detected by currently available neuroimaging studies in routine clinical settings. After providing a critical overview of in vivo data on white matter demyelinations and lacunes, we summarize the clinicopathological studies performed by our center in large cohorts of individuals with microvascular lesions and concomitant AD-related pathology across two age ranges (the younger old, 65-85 years old, versus the oldest old, nonagenarians and centenarians). In conjunction with other autopsy datasets, these observations fully support the idea that cortical microinfarcts are the only consistent determinant of cognitive decline across the entire spectrum from pure vascular cases to cases with combined vascular and AD lesion burden.
Resumo:
Three-dimensional imaging for the quantification of myocardial motion is a key step in the evaluation of cardiac disease. A tagged magnetic resonance imaging method that automatically tracks myocardial displacement in three dimensions is presented. Unlike other techniques, this method tracks both in-plane and through-plane motion from a single image plane without affecting the duration of image acquisition. A small z-encoding gradient is subsequently added to the refocusing lobe of the slice-selection gradient pulse in a slice following CSPAMM acquisition. An opposite polarity z-encoding gradient is added to the orthogonal tag direction. The additional z-gradients encode the instantaneous through plane position of the slice. The vertical and horizontal tags are used to resolve in-plane motion, while the added z-gradients is used to resolve through-plane motion. Postprocessing automatically decodes the acquired data and tracks the three-dimensional displacement of every material point within the image plane for each cine frame. Experiments include both a phantom and in vivo human validation. These studies demonstrate that the simultaneous extraction of both in-plane and through-plane displacements and pathlines from tagged images is achievable. This capability should open up new avenues for the automatic quantification of cardiac motion and strain for scientific and clinical purposes.
Resumo:
PURPOSE: To implement and characterize a fluorine-19 ((19)F) magnetic resonance imaging (MRI) technique and to test the hypothesis that the (19)F MRI signal in steady state after intravenous injection of a perfluoro-15-crown-5 ether (PCE) emulsion may be exploited for angiography in a pre-clinical in vivo animal study. MATERIALS AND METHODS: In vitro at 9.4T, the detection limit of the PCE emulsion at a scan time of 10 min/slice was determined, after which the T(1) and T(2) of PCE in venous blood were measured. Permission from the local animal use committee was obtained for all animal experiments. 12 µl/g of PCE emulsion was intravenously injected in 11 mice. Gradient echo (1)H and (19)F images were obtained at identical anatomical levels. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined for 33 vessels in both the (19)F and (1)H images, which was followed by vessel tracking to determine the vessel conspicuity for both modalities. RESULTS: In vitro, the detection limit was ∼400 µM, while the (19)F T(1) and T(2) were 1350±40 and 25±2 ms. The (19)F MR angiograms selectively visualized the vasculature (and the liver parenchyma over time) while precisely coregistering with the (1)H images. Due to the lower SNR of (19)F compared to (1)H (17±8 vs. 83±49, p<0.001), the (19)F CNR was also lower at 15±8 vs. 52±35 (p<0.001). Vessel tracking demonstrated a significantly higher vessel sharpness in the (19)F images (66±11 vs. 56±12, p = 0.002). CONCLUSION: (19)F magnetic resonance angiography of intravenously administered perfluorocarbon emulsions is feasible for a selective and exclusive visualization of the vasculature in vivo.
Resumo:
Segmenting ultrasound images is a challenging problemwhere standard unsupervised segmentation methods such asthe well-known Chan-Vese method fail. We propose in thispaper an efficient segmentation method for this class ofimages. Our proposed algorithm is based on asemi-supervised approach (user labels) and the use ofimage patches as data features. We also consider thePearson distance between patches, which has been shown tobe robust w.r.t speckle noise present in ultrasoundimages. Our results on phantom and clinical data show avery high similarity agreement with the ground truthprovided by a medical expert.
Resumo:
BACKGROUND: Transient balanced steady-state free-precession (bSSFP) has shown substantial promise for noninvasive assessment of coronary arteries but its utilization at 3.0 T and above has been hampered by susceptibility to field inhomogeneities that degrade image quality. The purpose of this work was to refine, implement, and test a robust, practical single-breathhold bSSFP coronary MRA sequence at 3.0 T and to test the reproducibility of the technique. METHODS: A 3D, volume-targeted, high-resolution bSSFP sequence was implemented. Localized image-based shimming was performed to minimize inhomogeneities of both the static magnetic field and the radio frequency excitation field. Fifteen healthy volunteers and three patients with coronary artery disease underwent examination with the bSSFP sequence (scan time = 20.5 ± 2.0 seconds), and acquisitions were repeated in nine subjects. The images were quantitatively analyzed using a semi-automated software tool, and the repeatability and reproducibility of measurements were determined using regression analysis and intra-class correlation coefficient (ICC), in a blinded manner. RESULTS: The 3D bSSFP sequence provided uniform, high-quality depiction of coronary arteries (n = 20). The average visible vessel length of 100.5 ± 6.3 mm and sharpness of 55 ± 2% compared favorably with earlier reported navigator-gated bSSFP and gradient echo sequences at 3.0 T. Length measurements demonstrated a highly statistically significant degree of inter-observer (r = 0.994, ICC = 0.993), intra-observer (r = 0.894, ICC = 0.896), and inter-scan concordance (r = 0.980, ICC = 0.974). Furthermore, ICC values demonstrated excellent intra-observer, inter-observer, and inter-scan agreement for vessel diameter measurements (ICC = 0.987, 0.976, and 0.961, respectively), and vessel sharpness values (ICC = 0.989, 0.938, and 0.904, respectively). CONCLUSIONS: The 3D bSSFP acquisition, using a state-of-the-art MR scanner equipped with recently available technologies such as multi-transmit, 32-channel cardiac coil, and localized B0 and B1+ shimming, allows accelerated and reproducible multi-segment assessment of the major coronary arteries at 3.0 T in a single breathhold. This rapid sequence may be especially useful for functional imaging of the coronaries where the acquisition time is limited by the stress duration and in cases where low navigator-gating efficiency prohibits acquisition of a free breathing scan in a reasonable time period.
Resumo:
Though rare, anomalous coronary artery disease is a well-known cause of myocardial ischemia and sudden death among children and young adults. The projectional nature of conventional x-ray angiography often leads to difficulty in the definition of anomalous vessels. Studies have now documented the high accuracy of coronary magnetic resonance angiography (MRA) for the noninvasive detection and definition of anomalous coronary arteries among patients with suspected anomalous coronary arteries of congenital conditions associated with anomalous coronary arteries. With increasing clinical experience, coronary MRA will likely emerge as the gold standard for the diagnosis of this condition.
Resumo:
Splenic arterial interventions are increasingly performed to treat various clinical conditions, including abdominal trauma, hypersplenism, splenic arterial aneurysm, portal hypertension, and splenic neoplasm. When clinically appropriate, these procedures may provide an alternative to open surgery. They may help to salvage splenic function in patients with posttraumatic injuries or hypersplenism and to improve hematologic parameters in those who otherwise would be unable to undergo high-dose chemotherapy or immunosuppressive therapy. Splenic arterial interventions also may be performed to exclude splenic artery aneurysms from the parent vessel lumen and prevent aneurysm rupture; to reduce portal pressure and prevent sequelae in patients with portal hypertension; to treat splenic artery steal syndrome and improve liver perfusion in liver transplant recipients; and to administer targeted treatment to areas of neoplastic disease in the splenic parenchyma. As the use of splenic arterial interventions increases in interventional radiology practice, clinicians must be familiar with the splenic vascular anatomy, the indications and contraindications for performing interventional procedures, the technical considerations involved, and the potential use of other interventional procedures, such as radiofrequency ablation, in combination with splenic arterial interventions. Familiarity with the complications that can result from these interventional procedures, including abscess formation and pancreatitis, also is important.