870 resultados para Ultrasound, high-intensity focused, transrectal


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. - This study aimed to test if investigate whether the anaerobic work capacity is replenished while exercising at critical power intensity. Then, a known exercise duration, which demands high anaerobic energy contribution, was compared to intermittent exercise duration with passive and active (cycling at critical power intensity) rest periods.Methods. - Nine participants performed five sessions of testing. From the 1st to the 3rd sessions, individuals cycled continuously at different workloads (P-high, P-intermediate and P-low) in order to estimate the critical power and the anaerobic work capacity. The 4th and 5th sessions were performed in order to determine the influence of anaerobic work capacity replenishment oil exercise duration. They consisted of manipulating the resting type (passive or active) between two cycling efforts. The total exercise duration was determined by the sum of the two cycling efforts duration.Results. - The exercise duration under passive resting condition (408.0 +/- 42.0 s) was longer (p<0.05) than known exercise duration at P-intermediate (T-intermediate = 305.8 +/- 30.5 s) and than exercise duration performed under active resting conditions (T-active = 304.4 +/- 30.7s). However, there was no significant difference between T-intermediate and T-active.Conclusion. - These results demonstrated indirect evidence that the anaerobic work capacity is not replenished while exercising at critical power intensity. (C) 2008 Elsevier Masson SAS. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this study were: (1) to verify the validity of previous proposed models to estimate the lowest exercise duration (T (LOW)) and the highest intensity (I (HIGH)) at which VO(2)max is reached (2) to test the hypothesis that parameters involved in these models, and hence the validity of these models are affected by aerobic training status. Thirteen cyclists (EC), eleven runners (ER) and ten untrained (U) subjects performed several cycle-ergometer exercise tests to fatigue in order to determine and estimate T (LOW) (ET (LOW)) and I (HIGH) (EI (HIGH)). The relationship between the time to achieved VO(2)max and time to exhaustion (T (lim)) was used to estimate ET (LOW). EI (HIGH) was estimated using the critical power model. I (HIGH) was assumed as the highest intensity at which VO2 was equal or higher than the average of VO(2)max values minus one typical error. T (LOW) was considered T (lim) associated with I (HIGH). No differences were found in T (LOW) between ER (170 +/- 31 s) and U (209 +/- 29 s), however, both showed higher values than EC (117 +/- 29 s). I (HIGH) was similar between U (269 +/- 73 W) and ER (319 +/- 50 W), and both were lower than EC (451 +/- 33 W). EI (HIGH) was similar and significantly correlated with I-HIGH only in U (r = 0.87) and ER (r = 0.62). ET (LOW) and T (LOW) were different only for U and not significantly correlated in all groups. These data suggest that the aerobic training status affects the validity of the proposed models for estimating I (HIGH).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of dentin abrasion on the microshear bond strength of two self-etching adhesive systems, using either an ultrasound diamond bur or a high-speed diamond bur.Materials and Methods: Twenty noncarious human third molars were sectioned mesiodistally into halves. The enamel was ground to expose a flat dentin surface on both sections. The dentinal surfaces were randomly assigned to two groups, depending on the method of smear layer preparation: ultrasound diamond bur (UB) or conventional diamond bur (CB). The prepared dentin surfaces received one of two self-etching systems: Clearfil SE Bond (CF) and One-Up Bond F (OB). A composite cylinder with a 0.95-mm diameter was bonded to each specimen and the microshear bond test was performed. The results were expressed in MPa and were subjected to two-way analysis of variance (ANOVA) and Tukey's test (alpha = 0.05).Results: There was no significant difference in dentin bond strength when comparing the conventional and ultrasonic abrasion methods. When the adhesive systems were compared, Clearfil SE Bond achieved higher bond strength means than did One-Up Bond F.Conclusion: The dentin surface preparation method did not influence the microshear bond strength and the Clearfil SE Bond adhesive system, independent of bur type used, Clearfil SE Bond showed higher bond strengths than did the One-Up Bond F adhesive system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. The use of ultrasonic tips has become an alternative for cavity preparation. However, there are concerns about this type of device, particularly with respect to intrapulpal temperatures and cavity preparation time.Purpose. The purpose of this study was to analyze pulpal temperature increases generated by an ultrasonic cavity preparation with chemical vapor deposition (CVD) tips, in comparison to preparation with a high-speed handpiece with a diamond rotary cutting instrument. The time required to complete the cavity preparation with each system was also evaluated.Material and methods. Thermocouples were positioned in the pulp chamber of 20 extracted human third molars. Slot-type cavities (3 x 3 x 2 mm) were prepared on the buccal and the lingual surfaces of each tooth. The test groups were: high-speed cavity preparation with diamond rotary cutting instruments (n = 20) and ultrasonic cavity preparation with CVD points (n = 20). During cavity preparation, the increases In pulpal temperature, and the time required for the preparation, were recorded and analyzed by Student's t test for paired samples (alpha = .05).Results. The average pulpal temperature increases were 4.3 degrees C for the high-speed preparation and 3.8 degrees C for the ultrasonic preparation, which were statistically similar (P = .052). However, significant differences were found (P < .001) for the time expended (3.3 minutes for the high-speed bur and 13.77 minutes for the ultrasound device).Conclusions. The intrapulpal temperatures produced during cavity preparation by ultrasonic tips versus high-speed bur preparation were similar. However, the use of the ultrasonic device required 4 times longer for the completion of a cavity preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasound effects on the release and activity of invertase from Aspergillus niger cultivated in a medium containing sucrose and peptone and in another with sugar-cane molasses and peptone were investigated. Irradiation was conducted for periods of 2 - 10 min. with waves of amplitude 20 and 40 using an ultrasound processor of 20 kHz. Product formation was determined as reducing equivalents formed by time units using 3,5-dinitrosalicylic acid. Total and specific activities of the culture supernatants were compared in the presence and absence of sonication. Both amplitudes promoted a significant increase of total invertase activity in the time periods investigated and the highest values were obtained with an amplitude of 20. Ultrasound irradiation caused cell disruption, thus releasing invertase and, after 4 min, activation of the enzyme also occurred. The best conditions for production, extraction and activation of invertase were in molasses medium containing peptone and irradiation with ultrasound waves at 20 for 8 min. This method showed high efficiency for the extraction and activation of invertase from A. niger as well as a great potential for use in industrial processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A regimen of progesterone plus estradiol (P&E) was used as a standard for ovarian synchronization to test the efficacy and evaluate the commercial application of ultrasound-guided follicle ablation as a non-steroidal alternative for ovulation synchronization in mares. Recipient mares at a private embryo transfer facility were at unknown stages of the estrous cycle at the start of the experiment on Day 1 when they were randomly assigned to an ablation group (n = 18-21 mares) or to a ME group (n = 20-21 mares). In the ablation group, mares were lightly sedated and all follicles > 10 mm were removed by transvaginal ultrasound-guided follicle aspiration. In the ME group, a combination of progesterone (150 mg) plus estradiol (10 mg) prepared in safflower oil was given daily (im) for 10 d. Two doses of prostaglandin FZ, (PGF, 10 mg/dose, im) were given 12 h apart on Day 5 in the ablation group, or a single dose on Day 10 in the ME group. Human chorionic gonadotropin (hCG, 2500 IU/mare, im) was given at a fixed time, 6 and 10 d after PGF treatment in the ablation and ME groups, respectively, with the expectation of a follicle > 30 mm at the time of treatment. In both the ablation and P&E groups, transrectal ultrasonography was done at the start of the study (Day 1) and again on the day of hCG treatment and daily thereafter to determine the presence of a CL, measure diameter of the largest follicle and detect ovulation. The mean interval from the start of the study and from PGF treatment to ovulation was shorter (P < 0.0001) in the ablation group (13.7 and 9.7 d, respectively) compared to the P&E group (22.3 and 13.2 d, respectively). Following fixed-day treatment with hCG after PGF treatment, the degree of ovulation synchronization was not different (P > 0.05) between the ablation and P&E groups within a 2-d (56 and 70%) or 4-d (83% and 90%) period. Although ultrasound-guided follicle ablation may not be practical in all circumstances, it excluded the conventional 10-d regimen of progesterone and estradiol and was considered an efficacious and feasible, non-steroidal alternative for ovulation synchronization in mares during the estrous cycle. (C 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work was to estimate the correlations among measurements taken in vivo with ultrasound equipment with some carcass traits measured after slaughter. Twenty eight Mediterranean bulls, with average shrunk body weight of 330 kg and 14 months of age, were fed by 120 days with high concentrate diets. The shrunk body weight, the ribeye area (REAU), the back fat thickness (FTU) over the Longissimus dorsi muscle between 12(a) and 13(a) ribs and rump fat (EGP8U), were measured at 28 days intervals. Real-time ultrasound equipment Piemedical Scanner 200 VET, with 18 cm linear array transducer was utilized. After the slaughter, the hot carcass weight (PCQ) and the kidney, pelvic and inguinal fat (GRPI) were weighted and the dressing percentage (DP) calculated. After 24 hours of cooling the ribeye area (REAC), backfat thickness (FTC) and rump fat (EGP8C) were measured. Both the REAC, FTC and EGP8C were underestimated by ultrasound measurements. The Pearson correlation coefficients for ribeye area, backfat thickness and rump fat measured in the carcass and with ultrasound, were 0.96, 0.99 and 0.91, respectively. The coefficient between DP and REAU was 0.47; 0.45 between DP and REAC, 0.56 between DP and FTU and 0.58 between DP and FTC. DP presented a 0.59 correlation coefficient with EGP8U. The Spearman correlation was estimated between REAU and REAC, FTU and FTC, EGP8U and EGP8C, and the values were 0.96, 0.99 and 0.91,respectively. The ultrasound measures could be used to estimate carcass traits in buffaloes with good accuracy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the effects of equine chorionic gonadotropin (eCG) treatment on the number of induced accessory corpora lutea (CL), plasma progesterone concentrations and pregnancy rate in cross-bred heifers after transfer of frozen-thawed (1.5 M ethylene glycol) embryos. All recipients received 500 mug PGF2alpha (dl-cloprostenol, i.m.) at random stages of the estrous cycle (Day 0) and were observed for estrus for 7 days. on Day 14, heifers detected in estrus between 2 and 7 days after PGF2alpha treatment were randomly allocated to four groups (n = 83 per group) and given 0 (control), 200, 400, or 600 IU of eCG. Two days later (Day 16), these recipients were given PGF2a and observed for estrus. Six to eight days after detection of estrus, plasma samples were collected to determine progesterone concentration and ultrasonography was performed to observe ovarian structures. Heifers with multiple CL or a single CL >15 mm in diameter received an embryo by direct transfer. Embryos of excellent and good quality were thawed and transferred to the recipients by the same veterinarian. Pregnancy was diagnosed by ultrasonography and confirmed by transrectal palpation 21 and 83 days after embryo transfer (ET), respectively. Plasma progesterone concentrations on the day of transfer (Day 7 of the estrous cycle) were 3.9 +/- 0.7, 4.2 +/- 0.4, 6.0 +/- 0.4, and 7.8 +/- 0.6 ng/ml for groups Control, 200, 400, and 600, respectively (Control versus treated groups P = 0.009; 200 versus 400 and 600 groups P = 0.0001; and 400 versus 600 P = 0.012). Conception rates 83 days after ET were 41.9, 50.0, 25.0, and 20.9% for groups Control, 200, 400, and 600, respectively (200 versus 400 and 600 groups P = 0.0036). In conclusion, an increase in progesterone concentration, induced by eCG treatment, did not improve pregnancy rates in ET recipients. Conversely, there was a decline in conception rates in the animals with the highest plasma progesterone concentrations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work a new europium (III) complex with the following formula NH(4) [Eu(bmdm)(4)] was synthesized and characterized. The bmdm (butyl methoxy-dibenzoyl-methane) is a P-diketone molecule used as UV radiation absorber in sunscreen formulations. Coordination of this ligand to the Eu(3+) ion was confinned by FT-IR, while the Raman spectrum suggests the presence of NH(4)(+) ions. The photoluminescence spectra present narrow lines arising from f-f intra-configurational transitions (5)D(0-)(7)F(0,1,2,3,4), dominated by the hypersensitive (5)D(0)-(7)F(2) transition. In the spectrum recorded at 77 K, all transitions split into 2J + 1 lines suggesting that there is just one symmetry site around Eu(3+) ion. This symmetry is not centrosymmetric. The calculated intensity parameters are ohm(2) = 30.5 x 10(-20) cm(2) and ohm(4) = 5.91 x 10(-20) cm(2) for this complex. The CIE chromaticity coordinates (x = 0.67 and y = 0.32) show a dominant wavelength of 615 nm. The color gamut achieved by this complex is a 100% in the CIE color space. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the plasma concentration of diclofenac sodium (DS) in dogs submitted to diclofenaco phonophoresis and to evaluate if phonophoresis induces greater absorption of this drug in dogs. Five dogs were used in eight different groups at different times: One group received oral administration of 40mg of DS per dog and seven groups received topical application of emulgel DS. The topical application area was 20cm(2). A continuous ultrasound frequency of 1MHz and intensity of 0.4W cm(-2) was used. Blood collections were performed before the treatment (T0), and 1h (T1) and 4h (T2) after ultrasound application for all groups. DS concentrations in plasma were measured by high performance liquid choramatohraphy (HPLC). There was significant increase of DS plasma concentration only at T1 in the oral administration group. It was not possible to detect any concentration of DS in the plasma of dogs after topical application of DS, even after DS phonophoresis. The facilitation of transdermal penetration by ultrasound has not been verified under the protocol specified in this research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Ultrasound (US) therapy is an elect rot hermotherapeutic modality that uses US energy to provoke physical and chemical alterations. US therapy has been widely used in physical therapy. However in clinical practice, it is contra-indicated in cancer patients due to the possibility of exacerbating tumor growth.Methods: Sixty-eight female Sprague-Dawley rats bred in UNIFAE vivarium were studied. At 50 days of age, 7, 12-dimetylbenz(a)anthracene (7, 12-DMBA) was administered to 35 rats by gastric gavage to induce mammary cancer After 90 days the mammary glands of the rats belonging to the group with mammary cancer induction and stimulated by US were removed. Animals received either continuous or pulsed US. US waves were generated at a frequency of 1 MHz during 10 days, with an intensity dose of 0.5 W in the continuous group, and 0.9 W (duty cycle: 20%) in the pulsed group.Results: Among the rats treated with continuous US, 44.4% developed local recurrence, while among the rats treated with pulsed US, 22.2% had local tumor recurrence (p < 0.05). No evidence of distant metastases was shown in any of the rats studied.Conclusion: The use ofcontinuous and pulsed therapeutic US promoted the development of local recurrence of mammary cancer in female Sprague-Dawley rats in the postoperative period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)