940 resultados para Ultrasonic atomization
Resumo:
Nowadays technological trend is based on finding materials that could support low weight with satisfactory mechanical properties and for this reason composite material became a very attractive topic in research projects all over the world. Due to its heterogenic properties, this type of material shows scatter in mechanical test results, especially in cyclic loading. Therefore it is important to predict its fatigue strength behaviour by statistic analysis, once fatigue causes approximately 90% of the failure in structural components. The present work aimed to investigate the fatigue behaviour of the Twill/Cycom 890 composite, which is carbon fiber reinforced with polymeric resin as matrix and manufactured via RTM process (Resin Transfer Molding). All samples were tested in different tensile level in triplicate in order to associate these values. The statistical analysis was conducted with Two-Parameter Weibull Distribution and then evaluated the fatigue life results for the composite. Weibull graphics were used to determine the scale and shape parameters. The S-N curve for the Twill/Cycom composite was drawn and indicated the number of cycles to occur the first damages in this material. The probability of failure was associated with material reliability, as shown in graphics for the different tensile levels and fatigue life. In addition, the laminate was evaluated by ultrasonic inspection showing a regular impregnation. The fractographic analysis conducted by SEM showed failure mechanisms for polymeric composites associated to cyclic loadings ... (Complete abstract click electronic access below)
Resumo:
In order to study resin distribution and homogeneity of composite laminates manufactured by RTM, it was used CYCOM 890 monolithic toughened epoxy as a matrix with two different configurations of intermediated modulus (IM) carbon fibers: Satin Weave (5HS) and non crimp fabric (NCF). The injection parameters were defined based on Thermo Gravimetric Analysis (TG), Differential Scanning Calorimetry (DSC) and rheological analysis. After processing the material, the resin/fiber impregnation was studied using ultrasonic test, Thermo Gravimetric Analysis, Differential Scanning Calorimetry, Dynamic Mechanical Analysis (DMA) and flexural tests. Therefore, it was able to observe an internal residual stress during the cooling process in both laminates, higher in the composite using NCF fabric due to the lack of symmetry, although a good proportion of fiber/matrix has been verified by the lower values of flexural modulus deviation. The DMA enabled the visualization of glass transition and its association with the inter and intra molecular interaction and movement, in which the NCF composite presented better permeability due to the lowest temperature of glass transition, when compared to the Satin Weave composite
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The application of ultrasonic waves during the initial setting of the glass ionomer cements (GIC) has demonstrated increase of the cure speed, reduction of air bubbles and improves in some mechanical properties. The aim of this study was to evaluate the effect of the ultrasound on the microhardness and the superficial roughness in two GICs (FUJI IX GP (GC Corporation) and Ketac Molar EasyMix (3M ESPE)). Forty specimens were confectioned, twenty for evaluation of the superficial roughness and twenty for evaluation of the microhardness. Half of them received for thirty seconds the ultrasonic waves application. The readings of the roughness had been carried before and after the toothbrushing test. The twenty remaining specimens had been polished with abrasive sandpapers of decreasing granulations and submitted to the hardness test. The results, analyzed for the variance analysis (ANOVA) (p<0,05), had demonstrated increase of the hardness for all the groups with the application of ultrasonic waves, being bigger for the Ketac Molar EasyMix. The ultrasound application also caused significant reduction of the superficial roughness for the Ketac Molar EasyMix. After the toothbrushing test, this last property increased for all the materials. It could be concluded that the application of ultrasonic waves was effective in increasing the superficial hardness of the materials and that it improved the roughness of the Ketac Molar EasyMix before the toothbrushing test.
Resumo:
The aim of this study was to evaluate the effect of the working angle variation of the magnetoestritive ultrasonic (MU) and air polishing devices (APD) on the roughness and wear of dental root. Fifty bovine incisive teeth were used in this study. The proximal surfaces of the teeth were divided in three regions: coronal, median, and an apical. The coronal region was treated with a manual scaler, the apical region was treated with APD or with a MU and the medium region was maintained untreated to serve as a control. The teeth were divided in 11 groups according to the treatment applied: MU-0º; MU-30º; MU-45º; MU-60º; MU-90º; AP-0º; AP-30º; AP-45º; AP-60º; AP-90º; MS: manual scaler. To the statistical analysis, data submitted to the Anova and Tukey's test (p < 0.05). The manual curette promotes less roughness and higher tooth wear in comparison with the both ultrasonic and air polishing devices (p < 0.05). The angles of 45º, 60º and 90º caused higher rate of tooth wear and roughness when the MU was used (p < 0.05), while the angle of 90° caused a higher tooth wear than the angle of 30° when the APD was used (p < 0.05). The working angle variation influenced the tooth wear and roughness promoted by MU, whereas when using APD, the working angle variation influenced only the tooth wear.
Resumo:
The aim of this study was to review the literature on the systems used to decontaminate the implant's surface. Different instruments have been proposed, but there is no agreement in the literature about which methods would be more efficient with no damage to the implant surface. It was reported the use of plastic, carbon fiber, stainless-steel and titanium curettes and also the use of other systems such as ultrasonic points with different tips, rubber cups and air abrasion. Literature review: In most of the studies, the injury caused on the titanium surface at the time of instrumentation was examined. In others, the cell adhesion on the titanium dental implants following instrumentation of the implant surface was observed. Moreover, to enhance cleaning around implants, ultrasonic systems were recently tested. Conclusion: Metal instruments can lead to major damage to implant surface, therefore, they are not indicated for decontamination of dental implants surfaces. Furthermore, non-metallic instruments, such as plastic curettes, rubber cups, air abrasion and some ultrasonic systems seem to be better choices to remove calculus and plaque of the sub- and supra-gingival peri-implant area. It is noteworthy that more studies evaluating the effects of these systems are required to establish best practices to be used in the treatment of patients with dental implants.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The endodontic surgery is indicated in cases of failure and/or impossibility of conventional endodontic treatment. Among the existent modalities in the endodontic surgery, the retrograde filling consists on preparation of apical cavity and filling with a retrofilling material. The technical-scientific progress in Endodontics become possible the use of retrotips activated with ultrasonic for retrocavities preparation with appropriate extension and following the long axis of the root. The aim of the study was to present the current resources in the preparation of the retrograde cavity in endodontic surgery, detaching their advantages in comparison with the use of conventional preparation with burns. A review of the literature will be presented, considering the use of ultrasound and laser for retrograde preparation, seeking the current resources that provide better apical preparation, resulting in better prognostic of the endodontic surgery (AU)
Resumo:
The aim of this study was to evaluate the presence of residues of sodium hypo-chlorite gel, chlorhexidine gel, and EDTA gel on dentina l walls after canal preparat ion throughchemical SEM- elemental chemical microanal ys is (EDS) analysis. Forty-eight single-rootedteeth were selected. They had their crowns sectioned and were instrumented with a reciprocat-ing system. The canals were irrigated with 5 mL of saline solution during root canal preparation.After instrumentation, the root canals were irrigated with 3 mL 17% EDTA followed by 1 min ofultrasonic passive activation (33 20 sec) to remove the smear layer, and then irrigated with3 mL of saline solution. The specimens were randomized into three groups (n 5 12) accord ing tothe chemical substance that filled the root canal for 30 min: GI: 5.5% sodium hypochlorite gel;GII: 2% chlorhexidine gel; GIII: 24% EDTA gel; Negative c ontrol group: no substance was used.Then, the root canals were irrigated with 6 mL of saline solution followed by 1 min of ultrasonicpassive activation (33 20 sec). After ultrasonic activation , the canals were irrigated with 2 mLsaline. The roots were sect ioned, and the perce ntage of each chemical element present in thesamples was analyzed through chemi cal SEM-EDS microanalysis. All expe rimental groupsshowed a significantly higher percentage of chemical elements (Na and/or Cl) than the controlgroup (P < 0.03). This in vitro study has shown that, regardless of chemical solutions used evenafter the final irrigation protocol, chemical residues of d ifferent substances remained attached tothe r oot c anal wa lls. Microsc. Res. Tech. 78:495–49 9, 2015.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)