1000 resultados para Ultra-sonografia doppler dupla


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Studies have recently focused on the effect of running a mountain ultra-marathon (MUM) and their results show muscular inflammation, damage and force loss. However, the link between peripheral oedema and muscle force loss is not really established. We tested the hypothesis that, after a MUM, lower leg muscles' swelling could be associated with muscle force loss. The knee extensor (KE) and the plantar flexor (PF) muscles' contractile function was measured by supramaximal electrical stimulations, potentiated low- and high-frequency doublets (PS10 and PS100) of the KE and the PF were measured by transcutaneous electrical nerve stimulation and bioimpedance was used to assess body composition in the runners (n = 11) before (Pre) and after (Post) the MUM and compared with the controls (n = 8). RESULTS: The maximal voluntary contraction of the KE and the PF significantly decreased by 20 % Post-MUM in the runners. Hydration of the non-fat mass (NF-Hyd) and extracellular water volume (Ve) were increased by 12 % Post-MUM (p < 0.001) in the runners. Calf circumference (+2 %, p < 0.05) was also increased. Significant relationships were found for percentage increases in Ve and NF-Hyd with percentage decrease in PS10 of the PF (r = -0.68 and r = -0.70, p < 0.05) and with percentage increase of calf circumference (r = 0.72 and r = 0.73, p < 0.05) in the runners. CONCLUSIONS: The present study suggests that increases in circumference and in hydric volume are associated to contractile impairment in the calf in ultra-marathon runners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a eficácia da dupla leitura de mamografias de rotina para rastreamento do câncer de mama, em ambiente privado (não acadêmico). MATERIAIS E MÉTODOS: Durante um ano, 22.024 mamografias de rastreamento, em mulheres assintomáticas, foram submetidas a dupla leitura independente, por dois radiologistas especializados em imaginologia mamária. Foram determinados o número de carcinomas adicionais encontrados com a dupla interpretação e o número absoluto de reconvocações geradas por tal prática. RESULTADOS: Foram detectados nove carcinomas adicionais com a dupla leitura, sendo 55,5% ductal in situ e o restante, ductal invasivo até 1,5 cm. Nosso índice de reconvocação absoluto gerado pela dupla interpretação foi de apenas 1,8%, com achados falso-positivos em 98%. CONCLUSÃO: O uso da dupla leitura no rastreamento mamográfico aumentou o índice de detecção de câncer em 8,5% e todos os tumores encontrados foram estádio 0 ou 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar, prospectivamente, qual o melhor período para a realização do Doppler das artérias uterinas na predição de complicações da gestação. MATERIAIS E MÉTODOS: Foi conduzido estudo prospectivo em 45 pacientes primigestas, sem história de doenças crônicas. O Doppler das artérias uterinas foi realizado entre 18-20, 24-26, 28-30 e 34-36 semanas, com determinação do índice de resistência, índice de pulsatilidade, relação A/B e a presença ou ausência de incisura na onda de velocidade de fluxo, assim como o resultado da gestação. RESULTADOS: Os índices Doppler apresentaram decréscimo com o decorrer da gestação, mais pronunciado nas gestações normais quando estas foram comparadas com aquelas que tiveram complicações, de maneira mais acentuada no exame realizado entre 24-26 semanas. A melhor relação entre sensibilidade e especificidade para a detecção de complicações durante a gestação foi obtida no exame realizado entre 24-26 semanas. CONCLUSÃO: O melhor período para a realização do Doppler das artérias uterinas na predição de complicações da gestação é o intervalo entre 24-26 semanas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Determinar a freqüência de visualização dos segmentos da circulação hepatomesentérica pela angiografia por ressonância magnética (angio-RM) com contraste e comparar o valor do método, utilizando-se duas diferentes dosagens de gadolínio (doses simples e dupla). MATERIAIS E MÉTODOS: Estudo prospectivo de 36 pacientes esquistossomóticos submetidos a angio-RM. Os exames foram realizados em equipamento de RM de 1,5 T, usando-se bobina de corpo e bomba injetora para a administração endovenosa do contraste. Foram utilizadas, de maneira randomizada, dose dupla do contraste paramagnético (0,2 mmol/kg de Gd-DTPA) em 21 pacientes e dose simples (0,1 mmol/kg) em outros 15 pacientes. Os exames foram interpretados por dois observadores em consenso, que classificaram o grau de visualização de 25 segmentos vasculares estabelecidos para análise, sem conhecimento da dose de gadolínio utilizada. RESULTADOS: Os segmentos vasculares proximais e de maior calibre foram as estruturas com melhor grau de visualização na maioria da amostra em estudo. O tronco celíaco, a artéria hepática comum, a artéria esplênica, a croça e terço médio da artéria mesentérica superior, a veia porta, a veia esplênica e a veia mesentérica superior apresentaram grau 2 de visualização em mais de 70% da amostra. Quanto à comparação das diferentes dosagens, não houve diferença significante (p < 0,05) no grau de visualização das diversas estruturas analisadas entre os grupos dose simples e dose dupla, com uma exceção isolada: na avaliação da artéria hepática direita (p = 0,008), o grupo dose simples apresentou maior freqüência de visualização grau 2, com valor significante. CONCLUSÃO: O grau de visualização dos segmentos vasculares hepatomesentéricos pela angio-RM com contraste é elevado, sendo maior nos segmentos proximais e de maior calibre. A comparação entre os grupos que utilizaram dose simples e dupla de contraste demonstrou resultados semelhantes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Comparar a eficácia do Doppler das artérias uterinas e de marcadores séricos maternos na predição de complicações da gestação. MATERIAIS E MÉTODOS: Trata-se de um estudo prospectivo com 49 primigestas, incluídas no estudo na 18ª semana, sendo coletada a amostra sanguínea para a realização das dosagens séricas, realizadas pelo método de quimioluminescência (alfa-fetoproteína, gonadotrofina coriônica humana e óxido nítrico) e radioimunoensaio (peptídio atrial natriurético). O Doppler das artérias uterinas foi realizado entre 24-26 semanas, determinando a presença ou ausência de incisura na onda de velocidade de fluxo. Na análise estatística utilizou-se o teste de Mann-Whitney, para amostras não-paramétricas, e o teste exato de Fisher, para parâmetros qualitativos. RESULTADOS: Os valores de sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo foram, respectivamente, de 8,3%, 97,0%, 50,0% e 74,4% para a alfa-fetoproteína; 8,3%, 87,9%, 20,0% e 72,5% para a gonadotrofina coriônica humana; 16,7%, 97,0%, 33,3% e 76,2% para o peptídio atrial natriurético; e 16,7%, 93,9%, 50,0% e 75,6% para o óxido nítrico. A sensibilidade do Doppler foi de 75,0%, especificidade de 63,6%, valor preditivo positivo de 57,1% e valor preditivo negativo de 87,5%. CONCLUSÃO: O Doppler das artérias uterinas é melhor preditor de complicações da gestação quando comparado a alguns marcadores séricos em populações de baixo risco.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Gamma Knife surgery (GKS) is a noninvasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes the targeting of the ventrointermediate nucleus of the thalamus (e.g., Vim) for tremor. Objective: To enhance anatomic imaging for Vim GKS using high-field (7 T) MRI and Diffusion Weighted Imaging (DWI). Methods: Five young healthy subjects and two patients were scanned both on 3 and 7 T MRI. The protocol was the same in all cases, and included: T1-weighted (T1w) and DWI at 3T; susceptibility weighted images (SWI) at 7T for the visualization of thalamic subparts. SWI was further integrated into the Gamma Plan Software® (LGP, Elekta Instruments, AB, Sweden) and co-registered with 3T images. A simulation of targeting of the Vim was done using the quadrilatere of Guyot. Furthermore, a correlation with the position of the found target on SWI and also on DWI (after clustering of the different thalamic nuclei) was performed. Results: For the 5 healthy subjects, there was a good correlation between the position of the Vim on SWI, DWI and the GKS targeting. For the patients, on the pretherapeutic acquisitions, SWI helped in positioning the target. For posttherapeutic sequences, SWI supposed position of the Vim matched the corresponding contrast enhancement seen at follow-up MRI. Additionally, on the patient's follow-up T1w images, we could observe a small area of contrast-enhancement corresponding to the target used in GKS (e.g., Vim), which belongs to the Ventral-Lateral-Ventral (VLV) nuclei group. Our clustering method resulted in seven thalamic groups. Conclusion: The use of SWI provided us with a superior resolution and an improved image contrast within the central gray matter, enabling us to directly visualize the Vim. We additionally propose a novel robust method for segmenting the thalamus in seven anatomical groups based on DWI. The localization of the GKS target on the follow-up T1w images, as well as the position of the Vim on 7 T, have been used as a gold standard for the validation of VLV cluster's emplacement. The contrast enhancement corresponding to the targeted area was always localized inside the expected cluster, providing strong evidence of the VLV segmentation accuracy. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g., quadrilatere of Guyot, histological atlases, DWI) seems to show a very good anatomical matching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes the development of a fast and robust analytical method for the determination of 53 antibiotic residues, covering various chemical groups and some of their metabolites, in environmental matrices that are considered important sources of antibiotic pollution, namely hospital and urban wastewaters, as well as in river waters. The method is based on automated off-line solid phase extraction (SPE) followed by ultra-high-performance liquid chromatography coupled to quadrupole linear ion trap tandem mass spectrometry (UHPLC–QqLIT). For unequivocal identification and confirmation, and in order to fulfill EU guidelines, two selected reaction monitoring (SRM) transitions per compound are monitored (the most intense one is used for quantification and the second one for confirmation). Quantification of target antibiotics is performed by the internal standard approach, using one isotopically labeled compound for each chemical group, in order to correct matrix effects. The main advantages of the method are automation and speed-up of sample preparation, by the reduction of extraction volumes for all matrices, the fast separation of a wide spectrum of antibiotics by using ultra-high-performance liquid chromatography, its sensitivity (limits of detection in the low ng/L range) and selectivity (due to the use of tandem mass spectrometry) The inclusion of β-lactam antibiotics (penicillins and cephalosporins), which are compounds difficult to analyze in multi-residue methods due to their instability in water matrices, and some antibiotics metabolites are other important benefits of the method developed. As part of the validation procedure, the method developed was applied to the analysis of antibiotics residues in hospital, urban influent and effluent wastewaters as well as in river water samples

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Diagnóstico precoce de distúrbios miccionais pode diminuir as repercussões sociais e psicológicas e evitar lesões renais. O jato ureteral pode ser avaliado por estudo Doppler, método que apresenta boa associação com dados clínicos dos pacientes no que diz respeito ao diagnóstico de disfunção miccional. O objetivo deste estudo é avaliar a concordância interobservadores entre os tipos de jato ureteral. MATERIAIS E MÉTODOS: Estudo prospectivo de concordância interobservadores. Um total de 41 pacientes foi examinado sequencialmente por dois médicos ultrassonografistas. Para cada paciente, três curvas dopplerfluxométricas foram obtidas de jatos consecutivos de cada ureter. O número de picos em cada curva foi observado e classificado. A velocidade máxima do maior pico de cada onda foi observada. Coeficientes kappa (κ) foram calculados. RESULTADOS: A concordância interobservadores foi moderada (κ = 0,48; intervalo de confiança 95%: 0,36-0,60). O padrão platô foi o mais frequente. As velocidades máximas dos ureteres, medidas pelos dois observadores, foram de 32,37 cm/s e 35,63 cm/s, respectivamente. CONCLUSÃO: O exame das curvas dopplerfluxométricas do jato ureteral é método que demonstrou moderada concordância interobservadores.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Este estudo de campo objetivou identificar as alterações ultrassonográficas e hemodinâmicas indicativas da morbidade da esquistossomose mansônica em áreas endêmicas. MATERIAIS E MÉTODOS: Foram examinados pela ultrassonografia Doppler 554 pacientes esquistossomóticos em três áreas com níveis distintos de endemicidade: baixa endemicidade (n = 109); média endemicidade (n = 255) e alta endemicidade (n = 190). Para o estudo ultrassonográfico foi utilizado o protocolo da Organização Mundial da Saúde (Niamey Working Group, 2000). Pelo Doppler foram avaliados: vasos portais, artérias hepática e esplênica, veias hepáticas e vasos colaterais. RESULTADOS: Houve correlação significativa entre a frequência das alterações ultrassonográficas e o nível de endemicidade das áreas, exceto a hipertrofia do lobo esquerdo. As veias hepáticas apresentaram padrão de fluxo alterado em 23,7% dos casos, alteração esta relacionada à presença e à intensidade de espessamento periportal. A artéria hepática não apresentou alterações nos parâmetros avaliados. Os vasos colaterais foram identificados apenas na área de alta endemicidade. A artéria esplênica apresentou alterações (aumento do calibre, da velocidade e do índice de resistência) mais frequentes na área de alta endemicidade, com diferença significativa entre os grupos. CONCLUSÃO: A ultrassonografia Doppler mostrou-se ferramenta auxiliar importante no estudo da morbidade relacionada à esquistossomose mansônica, contribuindo para definição mais precisa do perfil da doença nas áreas endêmicas.