994 resultados para Total atomic charges


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effects of some factors on the performance of our Kalman filter in discrimination of closely spaced overlapping signals were investigated. The resolution power of the filter for overlapping lines can be strengthened by reduction of the step size in scans. The minimum peak separation of two lines which the Kalman filter can effectively handle generally equals two to three times the step size in scans. Significant difference between the profiles of the analysis and interfering lines and multiple lines from matrix in the spectral window of the analysis line are very helpful for the Kalman filter to discern closely spaced analysis and interfering signals correctly, which allow the filter well to resolve the line pair with very small peak distance or even the entirely coincident lines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper reports some definite evidence for the significance of wavelength positioning accuracy in multicomponent analysis techniques for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). Using scanning spectrometers commercially available today, a large relative error, DELTA(A) may occur in the estimated analyte concentration, owing to wavelength positioning errors, unless a procedure for data processing can eliminate the problem of optical instability. The emphasis is on the effect of the positioning error (deltalambda) in a model scan, which is evaluated theoretically and determined experimentally. A quantitative relation between DELTA(A) and deltalambda, the peak distance, and the effective widths of the analysis and interfering lines is established under the assumption of Gaussian line profiles. The agreement between calculated and experimental DELTA(A) is also illustrated. The DELTA(A) originating from deltalambda is independent of the net analyte/interferent signal ratio; this contrasts with the situation for the positioning error (dlambda) in a sample scan, where DELTA(A) decreases with an increase in the ratio. Compared with dlambda, the effect of deltalambda is generally less significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with the evaluation of the relative error (DELTA(A)) in estimated analyte concentrations originating from the wavelength positioning error in a sample scan when multicomponent analysis (MCA) techniques are used for correcting line interferences in inductively coupled plasma atomic emission spectrometry. In the theoretical part, a quantitative relation of DELTA(A) with the extent of line overlap, bandwidth and the magnitude of the positioning error is developed under the assumption of Gaussian line profiles. The measurements of eleven samples covering various typical line interferences showed that the calculated DELTA(A) generally agrees well with the experimental one. An expression of the true detection limit associated with MCA techniques was thus formulated. With MCA techniques, the determination of the analyte and interferent concentrations depend on each other while with conventional correction techniques, such as the three-point method, the estimate of interfering signals is independent of the analyte signals. Therefore. a given positioning error results in a larger DELTA(A) and hence a higher true detection limit in the case of MCA techniques than that in the case of conventional correction methods. although the latter could be a reasonable approximation of the former when the peak distance expressed in the effective width of the interfering line is larger than 0.4. In the light of the effect of wavelength positioning errors, MCA techniques have no advantages over conventional correction methods unless the former can bring an essential reduction ot the positioning error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correction of spectral overlap interference in inductively coupled plasma atomic emission spectrometry by factor analysis is attempted. For the spectral overlap of two known lines, a data matrix can be composed from one or two pure spectra and a spectrum of the mixture. The data matrix is decomposed into a spectra matrix and a concentration matrix by target transformation factor analysis. The component concentration of interest in a binary mixture is obtained from the concentration matrix and interference from the other component is eliminated. This method is applied to correcting spectral interference of yttrium on the determination of copper and aluminium: satisfactory results are obtained. This method may also be applied to correcting spectral overlap interference for more than two lines. Like other methods of correcting spectral interferences, factor analysis can only be used for additive spectral overlap. Results obtained from measurements on copper/yttrium mixtures with different white noise added show that random errors in measurement data do not significantly affect the results of the correction method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Kalman filter was developed for resolving overlapping lines in inductively coupled plasma atomic emission spectrometry (ICP-AES) and evaluated experimentally with the determination of La in the presence of Ho, and Cu in the presence of Pr. The whiteness of the innovation sequence for an optimal filter was explored to be the criterion for the correction of the wavelength positioning errors which may occur in spectral scans. Under the conditions of the medium-resolution spectrometer and 1.5 pm step size in scans, the filter effectively resolved the Cu/Pr line pair having a small peak separation of 4.8 pm. For the La/Ho line pair with a peak distance of 9.8 pm, an unbiased estimate for La concentration was still obtained even when the signal-to-background ratio was down to 0.048. Favourable detection limits for real samples were achieved. Unstructured backgrounds were modeled theoretically and all spectral scans therefore did not require the correction for solvent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the evaluation of the reliability of the analytical results obtained by Kalman filtering. Two criteria for evaluation were compared: one is based on the autocorrelation analysis of the innovation sequence, the so-called NAC criterion; the other is the innovations number, which actually is the autocorrelation coefficient of the innovation sequence at the initial wavelength. Both criteria allow compensation for the wavelength positioning errors in spectral scans, but there exists a difference in the way they work. The NAC criterion can provide information about the reliability of an individual result, which is very useful for the indication of unmodelled emissions, while the innovations number should be incorporated with the normalization of the innovations or seek the help of the sequence itself for the same purpose. The major limitation of the NAC criterion is that it does not allow the theoretical modelling of continuous backgrounds, which, however, is convenient in practical analysis and can be taken with the innovations number criterion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of least-squres polynomial smoothing in ICP-AES is discussed and a method of points insertion into spectral scanning intervals is proposed in the present paper. Optimal FWHM/SR ratio can be obtained, and distortion of smoothed spectra can be avoided by use of the recommended method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most attractive features of derivative spectrometry is its higher resolving power. In the present power, numerical derivative techniques are evaluated from the viewpoint of increase in selectivity, the latter being expressed in terms of the interferent equivalent concentration (IEC). Typical spectral interferences are covered, including flat background, sloped background, simple curved background and various types of line overlap with different overlapping degrees, which were defined as the ratio of the net interfering signal at the analysis wavelength to the peak signal of the interfering line. the IECs in the derivative spectra are decreased by one to two order of magnitudes compared to those in the original spectra, and in the most cases, assume values below the conventional detection limits. The overlapping degree is the dominant factor that determines whether an analysis line can be resolved from an interfering line with the derivative techniques. Generally, the second derivative technique is effective only for line overlap with an overlapping degree of less than 0.8. The effects of other factors such as line shape, data smoothing, step size and the intensity ratio of analyte to interferent on the performance of the derivative techniques are also discussed. All results are illustrated with practical examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a laser induced sensitized fluorescence spectrometry for measuring the spontaneous emission branching ratios o?the transitions from the ten levels 5f36d7s7p-7M7, 5f36d7s7p-7L6, 5f37s27p-5K6, 5f26d27s2 - 5L7, 5f46d7s - 7L6, (17,070cm-1)-5L6, 5f26d27s2-5K6, 6d7s7p-7L5, 5f36d7s7p-7K5 and 5f26d27s2-5I5 to the ground state of atomic uranium (UI) for the first time. Their relative oscillator strengths have been measured by means of hollow cathode discharge (HCD) emission spectrometry. The radiative...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The extracts obtained from 28 species of marine algae were evaluated for their antioxidant activity (AA) versus the positive controls butylated hydroxytoluene (BHT), gallic acid (GA), and ascorbic acid (AscA). Most of the tested samples displayed antioxidant activity to various degrees. Among them, the extract of Symphyocladia latiuscula exhibited the strongest AA, which was comparable to BHT, GA, and AscA in radical scavenging activity, as shown in the DPPH (alpha,alpha-diphenyl-beta-picrylhydrazyl) assay, and higher than those of the positive controls in beta-carotene-linoleate assay system. In addition, the ethyl acetate-soluble fraction isolated from the crude extract of S. latiuscula exhibited the highest antioxidant activity in both assay systems. This fraction was further fractionated into seven subfractions (F1-F7) by vacuum liquid chromatography (VLC). F1 and F4 were found to be the most effective subfractions in scavenging DPPH radical assay and in the beta-carotene-linoleate assay, respectively. The total phenolic content (TPC) and reducing power (RP) for all of the extracts, fractions, and subfractions (F1-F7) were also determined. The TPC of the 28 extracts ranged from 0.10 to 8.00 gallic acid equivalents (mg/g seaweed dry weight) while the RP ranged from 0.07 to 11.60 ascorbic acid equivalents (mg center dot g(-1) seaweed dry weight). Highly positive relationships between AA and TPC as well as between AA and RP were found for the extracts and fractions, while for the subfractions F1-F7 only weak or no such relations were found. The results obtained from this study indicate that further analysis is needed of those marine algal species that contain the most antioxidant activity in order to identify the active principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polyculture of seaweeds alongside fed animal aquaculture is an environmentally friendly means of avoiding eutrophication problem both in land-based and sea-based monoculture systems. Many aspects of such polyculture systems have been described, but little attention has been given to the impact of live seaweeds on the microbiological properties of the water that connects the algae and animals. In this investigation, the Pacific red alga Gracilaria textorii was cultured in a recirculated dual tank system (150 L) with the juvenile abalone Haliotis discus hannai. Dynamic changes of total bacteria (TB) and total Vibrio (TV) in the water of polyculture and monoculture systems were evaluated. Results revealed that (1) level of TB in the polyculture was constantly higher than in the monoculture over a 6.5-day period. While levels of TV in the polyculture was detected to be constantly lower than in the monoculture, (2) integration of G. textorii in the abalone culture changed the Vibrio compositions in the water as judged by the changes of bacteria colony types; (3) application of artificial diet led to dramatic increase of the levels in TB and TV in both systems at 12 h after application in the 24-h test and resulted in selective propagation of Vibrio in the water in the monoculture system; (4) polyculture of G. textorii with juvenile abalone in combination with feeding with live algal diet helped to maintain low levels of TV and the balance of the Vibrio composition; (5) living biomass of G. textorii was effective in preventing propagation of two purified Vibrio strains (V alginolaticus and V logei) in the water. These results provide a general basis of the dynamic changes of levels in TB and TV in a seaweed-abalone polyculture system with or without artificial diet in tanks. (c) 2005 Elsevier B.V All rights reserved.