981 resultados para Test-day
Resumo:
Biological sensing is explored through novel stable colloidal dispersions of pyrrole-benzophenone and pyrrole copolymerized silica (PPy-SiO(2)-PPyBPh) nanocomposites, which allow covalent linking of biological molecules through light mediation. The mechanism of nanocomposite attachment to a model protein is studied by gold labeled cholera toxin B (CTB) to enhance the contrast in electron microscopy imaging. The biological test itself is carried out without gold labeling, i.e., using CTB only. The protein is shown to be covalently bound through the benzophenone groups. When the reactive PPy-SiO(2)-PPyBPh-CTB nanocomposite is exposed to specific recognition anti-CTB immunoglobulins, a qualitative visual agglutination assay occurs spontaneously, producing as a positive test, PPy-SiO(2)-PPyBPh-CTB-anti-CTB, in less than 1 h, while the control solution of the PPy-SiO(2)-PPyBPh-CTB alone remained well-dispersed during the same period. These dispersions were characterized by cryogenic transmission microscopy (cryo-TEM), scanning electron microscopy (SEM), FTIR and X-ray photoelectron spectroscopy (XPS).
Resumo:
1. The introduction of trawlers to Lake Victoria to harvest fish will have far reaching effects on the men (and women) presently engaged in the fishery, on the diet of the nation as a whole. 2. However, the whole concept of trawling is so different to present techniques and the scale of operation so great, that disruption to the socio-economy of many people is possible. 3. The sociological studies outlined below will assist the governments in the formulatlon of policies aimed at minimising disruptive effects on the lives of many individuals.
Resumo:
The Uganda waters of Lake Victoria comprise an area of 28,500 square kilometres with a shore line of 2,380 kilometres extending from the Uganda/Tanzania border in the west to the Uganda/Kenya border in the east. A large part of the Uganda waters of the lake is less than 60 metres deep, waters deeper than 60 metres being on the eastern side of the lake. Thus the Uganda part of the lake is tilted towards the east. A number of rivers drain into the lake from the north and the River Nile flows out of the lake towards the Mediterranean Sea. The Ssese, Kome, Buvuma and Busoga Islands form a very distinctive feature of the lake. These are perhaps the remaining high hills which survived the drowning of the northern valleys during the formation of the lake. In fact, in T. P. O'Brien's book 'The Prehistoric Uganda Protectorate (1939)', Solmon gives a critical summary of the work on the formation of Lake Victoria and shows that the northern part of the lake has numerous drowned valleys, a feature which provides varying habitats for particular species of fish and which may have an effect on the species composition reflected in the catches in different areas along the northern shore of the lake. It is interesting to note that although Lake Victoria as a whole has a number of rivers draining into it, Halbfass (1923) calculated and found that 76 per cent of the water entering the lake is precipitation on the lake surface.
Resumo:
Optimisation of cooling systems within gas turbine engines is of great interest to engine manufacturers seeking gains in performance, efficiency and component life. The effectiveness of coolant delivery is governed by complex flows within the stator wells and the interaction of main annulus and cooling air in the vicinity of the rim seals. This paper reports the development of a test facility which allows the interaction of cooling air and main gas paths to be measured at conditions representative of those found in modern gas turbine engines. The test facility features a two stage turbine with an overall pressure ratio of approximately 2.6:1. Hot air is supplied to the main annulus using a Rolls-Royce Dart compressor driven by an aero-derivative engine plant. Cooling air can be delivered to the stator wells at multiple locations and at a range of flow rates which cover bulk ingestion through to bulk egress. The facility has been designed with adaptable geometry to enable rapid changes of cooling air path configuration. The coolant delivery system allows swift and accurate changes to the flow settings such that thermal transients may be performed. Particular attention has been focused on obtaining high accuracy data, using a radio telemetry system, as well as thorough through-calibration practices. Temperature measurements can now be made on both rotating and stationary discs with a long term uncertainty in the region of 0.3 K. A gas concentration measurement system has also been developed to obtain direct measurement of re-ingestion and rim seal exchange flows. High resolution displacement sensors have been installed in order to measure hot running geometry. This paper documents the commissioning of a test facility which is unique in terms of rapid configuration changes, non-dimensional engine matching and the instrumentation density and resolution. Example data for each of the measurement systems is presented. This includes the effect of coolant flow rate on the metal temperatures within the upstream cavity of the turbine stator well, the axial displacement of the rotor assembly during a commissioning test, and the effect of coolant flow rate on mixing in the downstream cavity of the stator well. Copyright © 2010 by ASME.
Resumo:
This paper describes an experimental study of a new form of prestressed concrete beam. Aramid Fiber Reinforced Polymers (AFRPs) are used to provide compression confinement in the form of interlocking circular spirals, while external tendons are made from parallel-lay aramid ropes. The response shows that the confinement of the compression flange significantly increases the ductility of the beam, allowing much better utilization of the fiber strength. The failure of the beam is characterized by rupture of spiral confinement reinforcement.
Resumo:
A sensor for chemical species or biological species or radiation presenting to test fluid a polymer composition comprises polymer and conductive filler metal, alloy or reduced metal oxide and having a first level of electrical conductance when quiescent and being convertible to a second level of conductance by change of stress applied by stretching or compression or electric field, in which the polymer composition is characterised by at least one of the features in the form of particles at least 90% w/w held on a 100 mesh sieve; and/or comprising a permeable body extending across a channel of fluid flow; and/or affording in-and-out diffusion of test fluid and/or mechanically coupled to a workpiece of polymer swellable by a constituent of test fluid.
Resumo:
The Spoken Dialog Challenge 2010 was an exercise to investigate how different spoken dialog systems perform on the same task. The existing Let's Go Pittsburgh Bus Information System was used as a task and four teams provided systems that were first tested in controlled conditions with speech researchers as users. The three most stable systems were then deployed to real callers. This paper presents the results of the live tests, and compares them with the control test results. Results show considerable variation both between systems and between the control and live tests. Interestingly, relatively high task completion for controlled tests did not always predict relatively high task completion for live tests. Moreover, even though the systems were quite different in their designs, we saw very similar correlations between word error rate and task completion for all the systems. The dialog data collected is available to the research community. © 2011 Association for Computational Linguistics.
Resumo:
Portland cement has been widely used for stabilisation/solidification (S/S) treatment of contaminated soils. However, there is a dearth of literature on pH-dependent leaching of contaminants from cement-treated soils. This study investigates the leachability of Cu, Pb, Ni, Zn and total petroleum hydrocarbons (TPH) from a mixed contaminated soil. A sandy soil was spiked with 3000 mg/kg each of Cd, Cu, Pb, Ni and Zn, and 10,000 mg/kg of diesel, and treated with ordinary Portland cement (CEM I). Four different binder dosages, 5%, 10%, 15% and 20% (m/m) and different water contents ranging from 13%-19% dry weight were used in order to find a safe operating envelope for the treatment process. The pH-dependent leaching behaviour of the treated soil was monitored over an 84-day period using a 3-point acid neutralisation capacity (ANC) test. The monolithic leaching test was also conducted. Geotechnical properties such as unconfined compressive strength (UCS), hydraulic conductivity and porosity were assessed over time. The treated soils recorded lower leachate concentrations of Ni and Zn compared to the untreated soil at the same pH depending on binder dosage. The binder had problems with Pb stabilisation and TPH leachability was independent of pH and binder dosage. The hydraulic conductivity of the mixes was generally of the order, 10-8 m/sec, while the porosity ranged from 26%-44%. The results of selected performance properties are compared with regulatory limits and the range of operating variables that lead to acceptable performance described. © 2012 The Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences.