908 resultados para Termoeletricidade de concentração solar


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the influence of hydraulics and control of thermal storage in systems combined with solar thermal and heat pump for the production of warm water and space heating in dwellings. A reference air source heat pump system with flat plate collectors connected to a combistore was defined and modeled together with the IEA SHC Task 44 / HPP Annex 38 (T44A38) “Solar and Heat Pump Systems” boundary conditions of Strasbourg climate and SFH45 building. Three and four pipe connections as well as use of internal and external heat exchangers for DHW preparation were investigated as well as sensor height for charging of the DHW zone in the store. The temperature in this zone was varied to ensure the same DHW comfort was achieved in all cases. The results show that the four pipe connection results in 9% improvement in SPF compared to three pipe and that the external heat exchanger for DHW preparation leads to a 2% improvement compared to the reference case. Additionally the sensor height for charging the DHW zone of the store should not be too low, otherwise system performance is adversely affected

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic salt sorbent and water as a refrigerant, sealed under vacuum with no moving parts. A 5.6m2 aperture area outdoor laboratory-scale system of sorption module integrated solar collectors was installed in Stockholm, Sweden and evaluated under constant re-cooling and chilled fluid return temperatures in order to assess collector performance. Measured average solar cooling COP was 0.19 with average cooling powers between 120 and 200 Wm-2 collector aperture area. It was observed that average collector cooling power is constant at daily insolation levels above 3.6 kWhm-2 with the cooling energy produced being proportional to solar insolation. For full evaluation of an integrated sorption collector solar heating and cooling system, under the umbrella of a European Union project for technological innovation, a 180 m2 large-scale demonstration system has been installed in Karlstad, Sweden. Results from the installation commissioned in summer 2014 with non-optimised control strategies showed average electrical COP of 10.6 and average cooling powers between 140 and 250 Wm-2 collector aperture area. Optimisation of control strategies, heat transfer fluid flows through the collectors and electrical COP will be carried out in autumn 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar-powered vehicle activated signs (VAS) are speed warning signs powered by batteries that are recharged by solar panels. These signs are more desirable than other active warning signs due to the low cost of installation and the minimal maintenance requirements. However, one problem that can affect a solar-powered VAS is the limited power capacity available to keep the sign operational. In order to be able to operate the sign more efficiently, it is proposed that the sign be appropriately triggered by taking into account the prevalent conditions. Triggering the sign depends on many factors such as the prevailing speed limit, road geometry, traffic behaviour, the weather and the number of hours of daylight. The main goal of this paper is therefore to develop an intelligent algorithm that would help optimize the trigger point to achieve the best compromise between speed reduction and power consumption. Data have been systematically collected whereby vehicle speed data were gathered whilst varying the value of the trigger speed threshold. A two stage algorithm is then utilized to extract the trigger speed value. Initially the algorithm employs a Self-Organising Map (SOM), to effectively visualize and explore the properties of the data that is then clustered in the second stage using K-means clustering method. Preliminary results achieved in the study indicate that using a SOM in conjunction with K-means method is found to perform well as opposed to direct clustering of the data by K-means alone. Using a SOM in the current case helped the algorithm determine the number of clusters in the data set, which is a frequent problem in data clustering.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found. © 2012 The Authors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

http://digitalcommons.colby.edu/atlasofmaine2006/1022/thumbnail.jpg

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the recent construction of Colby Green and the current plans for the construction of several new buildings, the total area for future development on campus has declined. The goal of this study was to illustrate existing campus development and to determine where future growth could occur. GIS was used in determining the different soil systems on campus, the current use of the land, and the boundaries of the Colby property. The project shows what potential obstacles the college will have in attempting to expand the campus and proposes where the best options are for construction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O cluster é um fenômeno contemporâneo de grande importância, tendo sido cada vez mais estudado nos últimos anos em razão de sua importância estratégica para as empresas que o compõem, bem como para a região em que se localiza. Dessa forma,esta pesquisa objetiva identificar, analisar e classificar os fatores que contribuíram para o nascimento e manutenção de um cluster comercial especializado na distribuição varejista de produtos evangélicos na Rua Conde de Sarzedas (São Paulo – SP). Esta é uma pesquisa descritiva efetuada por meio de um levantamento de campo junto aos proprietários e gerentes das lojas varejistas do cluster comercial em estudo. Os principais fatores que contribuíram para o nascimento do cluster varejista foram: fundação da sede de uma grande igreja evangélica nos arredores, abertura de gravadora de discos evangélicos, participação de fiéis cantores, apoio da rádio e demanda dos produtos ofertados pelos fiéis. Já em relação à manutenção do cluster comercial, obteve-se os seguintes fatores propulsores: divulgação boca a boca, fácil acesso, preços acessíveis, atendimento especializado, ações de marketing,crescimento da população evangélica local e de outras regiões, cooperação entre lojistas, eventos de promoção específicos,desenvolvimento da economia brasileira e acesso à internet.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho foi calculada teoricamente a radiação solar direta normal para Porto Alegre e vizinhanças. Para tal fim foi feito um levantamento da insolação horária em Porto Alegre, entre os anos de 1968 a 1982 e, a partir destes como não se dispunha de dados experimentais, calculou-se a radiação solar global efetiva, com o auxílio de uma expressão do tipo Angstrom. A posse destes dados permitiu calcular a radiação direta normal, que se apresenta em forma de tabelas e gráficas. Como um resultado adicional, calculou-se a percentagem de dias aproveitáveis ou não para distintas hipóteses de uso da Energia Solar. Com o intuito de comprovar a validade dos cálculos desenvolvidos, compararam-se os dados de radiação difusa, calculados a partir dos de direta normal, com os obtidos por outras teorias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho experimental, apresenta-se várias propostas para a construção de sensores termoelétricos para a medida da radiação solar. 0s sensores construídos segundo estas propostas obedecem 4 configurações geométricas, e têm seus princípios de funcionamento de acordo com dois sistemas: Preto e Branco e de Grande Capacidade Calorífica. 0s materiais utilizados são facilmente encontrados no mercado brasileiro, e a técnica de construção é simples e assegura a reprodutibilidade dos instrumentos. Uma das grandes vantagens oferecidas por alguns destes instrumentos é a possibilidade da utilização de instrumentos auxliares de leitura, baratos e comuns no mercado brasileiro. Enfim, os instrumentos construídos para este trabalho são considerados bons, fornecem um sinal de saída alto e um custo relativamente baixo, quando comparado aos instrumentos importados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente trabalho constou de três experimentos. O primeiro objetivou verificar a influência de diferentes concentrações de plasma seminal e de dois diluentes na motilidade e na integridade e funcionalidade da membrana plasmática de espermatozóides eqüinos resfriados. Para tanto, foram utilizados 4 garanhões, comprovadamente férteis e em atividade sexual. Imediatamente após a coleta, o sêmen foi avaliado, diluído 1:2 com EDTA-glicose, dividido em oito alíquotas e centrifugado a 600g, por 10 minutos, para remoção do plasma seminal. O pellet de cada alíquota foi ressuspendido com um determinado volume do plasma seminal, previamente removido e acrescido de um determinado volume de um dos dois diluente (leite desnatado UHT ou leite desnatado-glicose) até atingir uma concentração final entre 40 e 50x106 espermatozóides/ml, contendo as seguintes concentrações finais de plasma seminal: 0%, 2,5%, 5% e 10%. Imediatamente após a diluição, o sêmen foi avaliado quanto à motilidade progressiva e total e funcionalidade e integridade da membrana plasmática. A seguir, os oito frascos contendo o sêmen, com um volume aproximado de 12 ml cada, foram resfriados em câmara a +4ºC a uma taxa de resfriamento de 0,3º C/min, sendo o sêmen novamente avaliado às 24, 48 e 72 horas.