997 resultados para Technique failure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Results from the Iowa Medicaid congestive heart failure population disease management demonstration confirm that a population and technology based remote monitoring platform can greatly reduce the need for costly acute care services by involving patients in their care, improving care effectiveness and promoting healthy behaviors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical picture of 15 patients (10 male, five female) with amyloid arthropathy secondary to chronic renal failure treated with haemodialysis has been studied. The average period of haemodialysis was 10.8 years. Joint symptoms appeared between three and 13 years after starting haemodialysis. No patient had renal amyloidosis. Early symptoms were varied and often overlapped: knee swelling (seven patients), painful and stiff shoulders (seven), and carpal tunnel syndrome (six) were the most prominent. Follow up showed extension to other joints. Joint effusions were generally of the non-inflammatory type. Radiologically, geodes and erosions of variable sizes were seen in the affected joints, which can develop into a destructive arthropathy. Amyloid was found in abdominal fat in three of the 12 patients on whom a needle aspiration was performed. Four of 12 patients showed changes compatible with amyloid infiltration in the echocardiogram. One patient had amyloid in the gastric muscular layer, another in the colon mucus, and two of four in rectal biopsy specimens. Amyloid deposits showed the presence of beta 2 microglobulin in 10 patients. The clinical and radiological picture was similar to the amyloid arthropathy associated with multiple myeloma. These patients can develop systemic amyloidosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superior vena cava (SVC) clamping can be required during thoracic surgery for SVC replacement or repair. In such cases, bypass techniques can be necessary to avoid hemodynamic instability, cerebral venous hypertension and hypoperfusion. Here, we report a novel and simple SVC bypass technique which does not require full systemic heparinization, specialized cannulation techniques or pumping devices and which can be applied percutaneously in the preoperative phase or intraoperatively. The preoperative shunt consisted in two Swan-Ganz catheters inserted in the jugular and femoral veins and connected by perfusion tubing with a three way stopcock. The intraoperative shunt consisted of a Pruitt(®)-catheter inserted in the left innominate vein and connected to a femoral Swan-Ganz catheter by perfusion tubing. We validated our system in seven patients undergoing SVC reconstruction. We monitored the systemic arterial blood pressures, the heart rate and vasoactive peptide requirements throughout the procedure. We also determined the neurological status and the in-hospital morbidity and mortality for each patient. Using this bypass, SVC clamping caused no hemodynamic instability, no neurological impairments and no in-hospital complications or deaths. This simple temporary SVC bypass procedure is safe and avoids hemodynamic instability and cerebral venous hypertension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of synovial amyloidosis is based upon synovial biopsy. Synovial fluid (SF) in seven patients with amyloid arthropathy associated with chronic renal failure undergoing haemodialysis were studied. The SF and synovial samples of 10 consecutive patients with seronegative mono- or oligoarthritis served as controls. Six of the seven patients with amyloid positive synovial biopsy specimens showed amyloid in their SF. No amyloid was found in the synovial tissue or fluid of the 10 patients in the control group, the sensitivity being 87.7%. The finding of amyloid in SF was highly reproducible, showing its presence in the same joint on several occasions. The deposits were Congophilia resistant to potassium permanganate pretreatment, and the immunohistochemical analysis proved that they contained beta 2 microglobulin. The high sensitivity and good reproducibility of the method shows that the finding of amyloid in SF is sufficient for the diagnosis of synovial amyloidosis. It is possible to perform immunohis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seven patients (five male and two female) with chronic renal failure (CRF) treated by periodical haemodialysis presented with swelling and effusion of more than three months' duration in knees (four bilateral), shoulders (two, one of them bilateral), elbow (one), and ankle (one). Four had a carpal tunnel syndrome both clinically and electromyographically (three bilateral). All patients had hyperparathyroidism secondary to their CRF, which was not due to amyloidosis in any of them. The dialysis duration period varied from five to 14 years, with an average of 8.6 years. Amyloid deposits (Congo red positive areas with green birefringence under polarising microscopy) were shown in six of the seven synovial biopsy specimens of the knee, in five of the sediments of the synovial fluids, and in specimens removed during carpal tunnel syndrome surgery. No amyloid was found in the biopsy specimen of abdominal fat of six of the patients. The finding of amyloid only in the synovial membrane and fluid, and carpal tunnel, its absence in abdominal fat, and the lack of other manifestations of generalised amyloidosis (cardiomyopathy, malabsorption syndrome, macroglossia, etc.) and of Bence Jones myeloma (protein immunoelectrophoresis normal) raises the possibility that this is a form of amyloidosis which is peculiar to CRF treated by periodical haemodialysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The occurrence of cachexia of multifactorial etiology in chronic heart failure (CHF) is a common and underestimated condition that usually leads to poor outcome and low survival rates, with high direct and indirect costs for the Health Care System. Recently, a consensus definition on cachexia has been reached, leading to a growing interest by the scientific community in this condition, which characterizes the last phase of many chronic diseases (i.e., cancer, acquired immunodeficiency syndrome). The etiology of cachexia is multifactorial and the underlying pathophysiological mechanisms are essentially the following: anorexia and malnourishment; immune overactivity and systemic inflammation; and endocrine disorders (anabolic/catabolic imbalance and resistance to growth hormone). In this paper, we review the main pathophysiological mechanisms underlying CHF cachexia, focusing also on the broad spectrum of actions of ghrelin and ghrelin agonists, and their possible use in combination with physical exercise to contrast CHF cachexia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to assess the applicability of posterior wall repair with a synthetic absorbable mesh. Between January and September 1996, five posterior repairs using absorbable synthetic meshes were performed. Five posterior wall repairs in patients matched for age, parity, and rectocele degree were performed according to usual procedures during the same period, and were used as controls. No febrile morbidity, cuff or posterior vaginal wall infections, thrombophlebitis, rectal injury, or hemorrhagic complications were observed in the 10 women who entered the study. In summary, posterior wall repair can be easily performed with an absorbable soft tissue patch, theoretically preserving sexual activity, and probably offers better functional results with longer experience, thus providing a safe and useful procedure in sexually active women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mainstay of contemporary therapies for extensive occlusive arterial disease is venous bypass graft. However, its durability is threatened by intimal hyperplasia (IH) that eventually leads to vessel occlusion and graft failure. Mechanical forces, particularly low shear stress and high wall tension, are thought to initiate and to sustain these cellular and molecular changes, but their exact contribution remains to be unraveled. To selectively evaluate the role of pressure and shear stress on the biology of IH, an ex vivo perfusion system (EVPS) was created to perfuse segments of human saphenous veins under arterial regimen (high shear stress and high pressure). Further technical innovations allowed the simultaneous perfusion of two segments from the same vein, one reinforced with an external mesh. Veins were harvested using a no-touch technique and immediately transferred to the laboratory for assembly in the EVPS. One segment of the freshly isolated vein was not perfused (control, day 0). The two others segments were perfused for up to 7 days, one being completely sheltered with a 4 mm (diameter) external mesh. The pressure, flow velocity, and pulse rate were continuously monitored and adjusted to mimic the hemodynamic conditions prevailing in the femoral artery. Upon completion of the perfusion, veins were dismounted and used for histological and molecular analysis. Under ex vivo conditions, high pressure perfusion (arterial, mean = 100 mm Hg) is sufficient to generate IH and remodeling of human veins. These alterations are reduced in the presence of an external polyester mesh.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have developed a digital holographic microscope (DHM), in a transmission mode, especially dedicated to the quantitative visualization of phase objects such as living cells. The method is based on an original numerical algorithm presented in detail elsewhere [Cuche et al., Appl. Opt. 38, 6994 (1999)]. DHM images of living cells in culture are shown for what is to our knowledge the first time. They represent the distribution of the optical path length over the cell, which has been measured with subwavelength accuracy. These DHM images are compared with those obtained by use of the widely used phase contrast and Nomarski differential interference contrast techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To retrospectively assess the frequency of adverse events related to percutaneous preoperative portal vein embolization (PPVE). MATERIALS AND METHODS: Institutional review board did not require its approval or patient informed consent for this study. The adverse events that occurred during PPVE or until planned hepatic surgery was performed or cancelled were retrospectively obtained from clinical, imaging, and laboratory data files in 188 patients (109 male and 79 female patients; mean age, 60 years; range, 16-78 years). Liver resection was planned for metastases (n = 137), hepatocarcinoma (n = 31), cholangiocarcinoma (n = 15), fibrolamellar hepatoma (n = 1), and benign disease (n = 4). PPVE was performed with a single-lumen 5-F catheter and a contralateral approach with n-butyl cyanoacrylate mixed with iodized oil as the main embolic agent. The rate of complications in patients with cirrhosis was compared with that in patients without cirrhosis by using the chi(2) test. RESULTS: Adverse events occurred in 24 (12.8%) of 188 patients, including 12 complications and 12 incidental imaging findings. Complications included thrombosis of the portal vein feeding the future remnant liver (n = 1); migration of emboli in the portal vein feeding the future remnant liver, which necessitated angioplasty (n = 2); hemoperitoneum (n = 1); rupture of a metastasis in the gallbladder (n = 1); transitory hemobilia (n = 1); and transient liver failure (n = 6). Incidental findings were migration of small emboli in nontargeted portal branches (n = 10) and subcapsular hematoma (n = 2). Among the 187 patients in whom PPVE was technically successful, there was a significant difference (P < .001) between the occurrence of liver failure after PPVE in patients with cirrhosis (five of 30) and those without (one of 157). Sixteen liver resections were cancelled due to cancer progression (n = 12), insufficient hypertrophy of the nonembolized liver (n = 3), and complete portal thrombosis (n = 1). CONCLUSION: PPVE is a safe adjuvant technique for hypertrophy of the initially insufficient liver reserve. Post-PPVE transient liver failure is more common in patients with cirrhosis than in those without cirrhosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diuretic and natriuretic responses to exogenous synthetic atrial natriuretic peptide (ANP) were evaluated in patients with chronic renal failure (CRF) or nephrotic syndrome (NS). Patients were studied after an oral water load (8 ml/kg in CRF and 20 ml/kg in NS patients). A short intravenous bolus of either a placebo or ANP was administered when urine output was stable. In each group of patients, three doses of ANP were injected at 24 h intervals, i.e., 1.0, 1.5, and 2.0 micrograms/kg in the CRF and 1.0, 1.5, and 3.0 micrograms/kg in the NS group. Blood pressure and heart rate were monitored throughout the study and urinary volume and electrolyte excretion were measured every 20 min up to 3 h after the bolus. An acute and transient fall in blood pressure was observed immediately after the ANP injection. It was more pronounced in CRF than in NS patients. In CRF patients, ANP caused only a slight increase in urinary volume (13.5-44% over baseline) but a significant increase in urinary sodium excretion (45-114% over baseline). In NS patients, significant increases in both urine volume (60-105%) and sodium excretion (149-248%) were also found. In these latter patients, the renal response to ANP appeared to be better preserved. The hemodynamic and renal changes induced by ANP occurred mainly during the first 20 min following the ANP administration, when the peak plasma ANP levels were obtained. However, no clear dose-response effect could be evidenced in either group with the three doses of ANP chosen in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Any transportation infrastructure system is inherently concerned with durability and performance issues. The proportioning and uniformity control of concrete mixtures are critical factors that directly affect the longevity and performance of the portland cement concrete pavement systems. At present, the only means available to monitor mix proportions of any given batch are to track batch tickets created at the batch plant. However, this does not take into account potential errors in loading materials into storage silos, calibration errors, and addition of water after dispatch. Therefore, there is a need for a rapid, cost-effective, and reliable field test that estimates the proportions of as-delivered concrete mixtures. In addition, performance based specifications will be more easily implemented if there is a way to readily demonstrate whether any given batch is similar to the proportions already accepted based on laboratory performance testing. The goal of the present research project is to investigate the potential use of a portable x-ray fluorescence (XRF) technique to assess the proportions of concrete mixtures as they are delivered. Tests were conducted on the raw materials, paste and mortar samples using a portable XRF device. There is a reasonable correlation between the actual and calculated mix proportions of the paste samples, but data on mortar samples was less reliable.