997 resultados para TRANSIENT ABSORPTION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A realistic model of the dipole radiation forces in transverse Doppler cooling (with a s+-s- laser configuration) of an atomic beam of group 13 elements is studied within the quantum-kinetic equation framework. The full energy level sub-structure for such an atom with I = 0 (such as 66Ga) is analysed. Two cooling strategies are investigated; the first involving the 2P3/2 ? 2D5/2 transition and the second a dual laser cooling experiment involving transitions 2P1/2 and 2P3/2 ? 2S1/2. The latter scheme creates a velocity-independent dark-state resonance that inhibits a steady-state dipole cooling force. However, time-dependent calculations show that transient cooling forces are present that could be exploited for laser cooling purposes in pulsed laser fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Transient ischemic attack (TIA) is a condition causing focal neurological deficits lasting less than 24hrs. TIA patients present similarly to other conditions with rapid onset of neurological symptoms such as migraine. The accurate diagnosis of TIA is critical because it serves as a warning for subsequent stroke. Furthermore, cognitive deficit associated with TIA may predict the development of dementia. Therefore, characterizing the cognitive symptoms of TIA patients and discriminating these patients from those with similar symptoms is important for proper diagnosis and treatment. Currently the diagnosis of TIA is made on clinical and radiographic evidence. Robotic assessment, with instruments such as the KINARM, may improve the identification of cognitive impairment in TIA patients. Methods: In this prospective cohort study, two KINARM tests, trail making task (TMT) and spatial span task (SST), were used to detect cognitive deficits. Two study groups were made. The TIA group was tested at 5 time points over the span of a year. The migraine active control group had one initial visit and another a year later. Both of these groups were compared to a normative database of approximately 400 healthy volunteers. From this database age and sex matched normative data was used to calculate Z-scores for the TMT. The Montreal Cognitive Assessment (MoCA) was also administered to both groups. Results: 31 participants were recruited, 20 TIA group and 11 active controls (mean ± SD age= 66 ± 11.3 and 62 ± 14.5). There was no significant difference in TIA and active control group MoCA scores. The TMT was able to detect cognitive impairment in TIA and migraine group. Also, both KINARM tasks could detect significant differences in performance between TIA and migraine patients while the MoCA could not. Changes in TIA and migraine performance on the MoCA, TMT, and SST were observed. Conclusions: The robotic KINARM exoskeleton can be used to assess cognitive deficits in TIA patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional absorption spectroscopy is not nearly sensitive enough for quantitative overtone measurements on submonolayer coatings. While cavity-enhanced absorption detection methods using microresonators have the potential to provide quantitative absorption cross sections of even weakly absorbing submonolayer films, this potential has not yet been fully realized. To determine the absorption cross section of a submonolayer film of ethylene diamine (EDA) on a silica microsphere resonator, we use phase-shift cavity ringdown spectroscopy simultaneously on near-IR radiation that is Rayleigh backscattered from the microsphere and transmitted through the coupling fiber taper. We then independently determine both the coupling coefficient and the optical loss within the resonator. Together with a coincident measurement of the wavelength frequency shift, an absolute overtone absorption cross section of adsorbed EDA, at submonolayer coverage, was obtained and was compared to the bulk value. The smallest quantifiable absorption cross section is σmin 2.7 × 10−12 cm2. This absorption cross section is comparable to the extinction coefficients of, e.g., single gold nanoparticles or aerosol particles. We therefore propose that the present method is also a viable route to absolute extinction measurements of single particles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Short liquid core waveguides (LCWs) were included into a fiber-loop cavity ring-down absorption spectrometer to reduce the detection limit over, both, single pass absorption in a LCW and cavityenhanced absorption using a conventional fiber-loop cavity. LCWs of 5 and 10 cm length were interfaced with a pressure-flow system and a multimode fiber-loop cavity using concave fiber lenses with matching numerical apertures and diameters. Two red dyes, Allura Red AC and Congo Red, were detected with a 532 nm pulsed laser at a 5 nM limit of detection in a detection volume of less than 1 μL, corresponding to a minimal detectable absorbance of less than 4 × 10−4 cm−1 and a minimal detectable change in absorption cross section, σmin = Vdet × ε × CLOD, of about 14 μm2 (Allura Red AC) and 37 μm2 (Congo Red).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cavity ring-down spectroscopy is a spectroscopic method that uses a high quality optical cavity to amplify the optical loss due to the light absorption by a sample. In this presentation we highlight two applications of phase-shift cavity ring-down spectroscopy that are suited for absorption measurements in the condensed phase and make use of waveguide cavities. In the first application, a fiber loop is used as an optical cavity and the sample is introduced in a gap in the loop to allow absorption measurements of nanoliters of solution at the micromolar level. A second application involves silica microspheres as high finesse cavities. Information on the refractive index and absorption of a thin film of ethylene diamine on the surface of the microresonator is obtained simultaneously by the measurements of the wavelength shift of the cavity mode spectrum and the change in optical decay time, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ring-down absorption spectroscopy is an emerging ‘‘label-free’’ detection method for analytical microdevices, such as micrototal analysis systems (l-TAS). Developed from the related gas-phase cavity ring-down absorption spectroscopy, fiber-optic-based ring-down techniques for liquid samples offer low detection limits, high sensitivity and fast response. ª 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The role of optical FeIII absorption lines in B-type stars as iron abundance diagnostics is considered. To date, ultraviolet Fe lines have been widely used in B-type stars, although line blending can severely hinder their diagnostic power. Using optical spectra, covering a wavelength range ~3560-9200Å, a sample of Galactic B-type main-sequence and supergiant stars of spectral types B0.5 to B7 are investigated. A comparison of the observed FeIII spectra of supergiants, and those predicted from the model atmosphere codes TLUSTY [plane-parallel, non-local thermodynamic equilibrium (LTE)], with spectra generated using SYNSPEC (LTE), and CMFGEN (spherical, non-LTE), reveal that non-LTE effects appear small. In addition, a sample of main-sequence and supergiant objects, observed with the Fiber-fed Extended Range Optical Spectrograph (FEROS), reveal LTE abundance estimates consistent with the Galactic environment and previous optical studies. Based on the present study, we list a number of FeIII transitions which we recommend for estimating the iron abundance from early B-type stellar spectra.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three plasma diagnostic methods, tunable infrared diode laser absorption spectroscopy, optical emission spectroscopy and microwave interferometry have been used to monitor concentrations of transient and stable molecules, CH3, CH4, C2H2, C2H6, and of electrons in capacitively coupled CH4-H-2-Ar radiofrequency (RF) plasmas (f(RF) = 13.56 MHz, p = 100 Pa, phi (total)= 66 sccm) for various discharge power values (P = 10-100 W) and gas mixtures. The degree of dissociation of the methane precursor varied between 3% and 60%. The methyl radical concentration was found to be in the order of 10(12) molecules cm(-3) and the electron concentration in the order of loll cm(-3). The methyl radical concentration and the concentrations of the stable C-2 hydrocarbons, C2H2 and C2H6, produced in the plasma, increased with discharge power. The fragmentation rates of the methane precursor and conversion rates to the measured C-2 hydrocarbons were estimated in dependence on discharge power. Radial distributions of the electron and methyl radical concentrations, and of the gas temperature were measured for the first time simultaneously in the plasma region between the discharge electrodes. The measurements allow us to draw qualitative conclusions on the main chemical processes and the plasma chemical reaction paths.