967 resultados para Spray nozzles
Resumo:
Purpose: To evaluate the effect of different cleaning media on the adhesion of resin cement to feldspathic ceramic after etching.Materials and Methods: The cementation surfaces of ceramic blocks (N = 20, n = 5 per group) were etched with 10% hydrofluoric acid (HF) gel for 20 s and rinsed for 60 s. They were then randomly assigned to 4 groups: G1: air-water spray+drying (control); G2: ultrasonic cleaning in distilled water for 4 min+drying; G3: ultrasonic cleaning in 99.5% acetone for 4 min+drying; G4: ultrasonic cleaning in 70% alcohol for 4 min+drying. The ceramic blocks were silanized and cemented (RelyX ARC) to the composite blocks. Subsequently, the microtensile bond strength test (mu TBS) was performed. In addition, EDS analysis was made to assess the elemental composition of the conditioned and cleaned ceramic surfaces.Results: A significantly higher mean mu TBS was obtained when specimens had been ultrasonically cleaned in distilled water (G2: 18.8 +/- 0.4 MPa) (p < 0.05) compared to other groups (G1: 16.6 +/- 0.5; G3: 16.1 +/- 0.9; G4: 15.8 +/- 1.4) (one-way ANOVA). EDS analysis indicated the presence of F- only in G1. Dissolved precipitates after HF etching were removed by ultrasonic cleaning.Conclusion: Cleaning the HF-etched ceramic surface ultrasonically in distilled water is recommended, instead of rinsing it with air-water spray only.
Resumo:
The purpose of this in vitro study was to evaluate alterations in the surface roughness and micromorphology of human enamel submitted to three prophylaxis methods. Sixty-nine caries-free molars with exposed labial surfaces were divided into three groups. Group I was treated with a rotary instrument set at a low speed, rubber clip and a mixture of water and pumice; group II with a rotary instrument set at a low speed, rubber cup and prophylaxis paste Herjos-F (Vigodent S/A Industria e Comercio, Rio de Janeiro, Brazil); and group III with sodium bicarbonate spray Profi II Ceramic (Dabi A dante Indtistrias Medico Odontologicas Ltda, Ribeirao Preto, Brazil). All procedures were performed by the same operator for 10 s, and samples were rinsed and stored in distilled water. Pre and post-treatment surface evaluation was completed using a surface profilometer (Perthometer S8P Marh, Perthen, Germany) in 54 samples. In addition, the other samples were coated with gold and examined in a scanning electron microscope (SEM). The results of this study were statistically analyzed with the paired t-test (Student), the Kruskal-Wallis test and the Dunn (5%) test. The sodium bicarbonate spray led to significantly rougher surfaces than the pumice paste. The use of prophylaxis paste showed no statistically significant difference when compared with the other methods. Based on SEM analysis, the sodium bicarbonate spray presented an irregular surface with granular material and erosions. Based on this study, it can be concluded that there was an increased enamel stuface roughness when teeth were treated with sodium bicarbonate spray when compared with teeth treated with pumice paste.
Resumo:
Comparative wear and corrosion properties of Cr3C2-NiCr (CC-TS) (a high-velocity oxyfuel [HVOF]) and hard chromium (HC) coating's obtained on a steel substrate have been studied. The structural characterization was done before and after measurements by optical microscopy, scanning electron microscopy, and scanning white light interferometry. Wear and corrosion properties were evaluated by ball on disk (ASTM G99-90), rubber wheel (ASTM G65-91), and electrochemical measurements of open circuit and polarization curves. The best corrosion and wear resistance was for the CC-TS obtained by HVOF. The open-circuit potential values measured for both samples after 18 h of immersion we're: -0.240 and -0.550 V, respectively, for CC-TS and HC, versus Ag/AgCl,KClsat. Three orders of magnitude lower volume loss were found for CC-TS (HVOF) after friction tests compared with HC.
Resumo:
In the present work the corrosion resistance of micro-cracked hard chromium and Cr3C2-NiCr (HVOF) coatings applied on a steel substrate have been compared using open-circuit potential (E-OC) measurements, electrochemical impedance spectroscopy (EIS) and polarization curves. The coatings surfaces and cross-section were characterized before and after corrosion tests using optical microscopy (OM) and scanning electron microscopy (SEM). After 18 h of immersion, the open-circuit potential values were around -0.50 and -0.25V/(Ag vertical bar AgCl vertical bar KClsat) for hard chromium and Cr3C2- NiCr, respectively. The surface analysis done after 12 h of immersion showed iron on the hard chromium surface inside/near surface cracks, while iron was not detected on the Cr3C2-NiCr surface even after 18 h. For longer immersion time hard chromium was more degraded than thermal sprayed coating. For hard chromium coating a total resistance values between 50 and 80 k Omega cm(2) were measured and two well-defined time constants were observed, without significant change with the immersion time. For Cr3C2-NiCr coating the total impedance diminished from around 750 to 25 k Omega cm(2) as the immersion time increased from 17 up to 132 h and two overlapped time constants were also observed. Polarization curves recorded after 18 h of immersion showed a lower current and higher corrosion potential for Cr3C2-NiCr coating than other samples studied. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The influence of heat-treatments on the electrochemical behavior of thermal spray Cr3C2-NiCr coatings prepared by high velocity oxygen fuel (HVOF) was studied in NaCl solution, at 25 degrees C, using open-circuit potential (E-OC) and electrochemical impedance spectroscopy (EIS) measurements. Coating characterization were performed before and after the heat-treatments and electrochemical tests by scanning electron microscopy, X-ray diffraction, and Auger electron spectroscopy. In addition to the changes in the original powder composition occurring during HVOF process, heat-treatment performed at 450 degrees C caused no significant changes in electrochemical response compared with untreated sample, and at 760 degrees C the main difference was the formation of a thin and defective layer of Cr2O3 at the coating surface, which increased the total impedance at the first day of immersion. Higher influence on the electrochemical was noted for samples treated at 880 degrees C, which also showed higher E-OC and total impedance, and lower corrosion current. This behavior was interpreted considering the formation of a chromium oxide layer on the coating surface, dissolution and decomposition of smaller carbide particles and their surface enrichment with Cr due to C diffusion and dissolution into the matrix, and possible Ni, Cr, and Fe diffusion to coating/substrate interface. (c) 2006 the Electrochemical Society.
Resumo:
Thermal spray WC-based coatings are widely used in the aircraft industry mainly for their resistance to wear, reworking and rebuilding operations and repair of worn components on landing gear, hydraulic cylinders, actuators, propeller hub assemblies, gas turbine engines, and so on. The aircraft industry is also trying to use thermal spray technology to replace electroplating coatings such as hard chromium. In the present work, WC-Co coatings were built up on an AA 7050 aluminum alloy using high velocity oxygen fuel (HVOF) technology and a liquid nitrogen cooling prototype system. The influence of the spray parameters (standard conditions, W19S, increasing the oxygen flux, W19H, and also increasing the carrier gas flux, W19F) on corrosion, friction, and abrasive wear resistance were also studied. The coatings were characterized using optical (OM) and scanning electron (SEM) microscopy, and X-ray diffraction (XRD). The friction and abrasive wear resistance of the coatings were studied using Rubber Wheel and Ball on Disk tests. The electrochemical studies were conducted using open-circuit potential (E(oc)) measurements and electrochemical impedance spectroscopy (EIS). Differences among coated samples were mainly related to the variation of the thermal spray parameters used during the spray process. No significant differences were observed in the wear resistance for the coatings studied, and all of them showed a wear rate around 10 times lower than that of the aluminum alloy. The results of mass loss and wear rate were interpreted considering different mechanisms. Comparing the different spray parameters, the oxygen flux (higher flame temperature) produced the sample which showed the highest corrosion resistance in aerated and unstirred 3.5% NaCl solution. Aluminum ions were detected on the surface almost immediately after the immersion of samples W19S and W19F in chloride solution, showing that the electrolyte reached the substrate and galvanic corrosion probably occurred. For sample W19H, aluminum ions were not detected even after 120 min of immersion in NaCl solution. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O artigo teve como objetivo estudar a evolução do crescimento, distribuição e classificação dos pites em aços inoxidáveis austeníticos AISI 310S no estado como recebida e tratado termicamente, submetidos a diferentes tempos de exposição em meio salino. A aplicabilidade deste trabalho baseou-se no desenvolvimento de uma técnica para caracterização morfológica da corrosão localizada, associado com os aspectos de descrição de formas, tamanho, parâmetros específicos e populacionais. A metodologia consistiu nas seguintes etapas: preparação dos corpos de prova, testes de corrosão via névoa salina em diferentes condições, análise microestrutural, análise dos perfis dos pites, processamento digital e análise de imagens, visando caracterizar a distribuição, morfologia e o tamanho dos pites. Os resultados obtidos no processamento digital e análise de imagens dos perfis foram submetidos á análise estatística, utilizando à mediana como parâmetro de avaliação na liga como recebido e tratada. A liga como recebido, exibe a seguinte morfologia: pites hemisféricos> região de transição A> região de transição B> irregulares> cônicos. A quantidade de pites na liga tratada a cada tempo de exposição é: região de transição B> hemisféricos> região de transição A> cônicos> irregulares.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O objetivo deste trabalho foi avaliar o efeito da aplicação de silício por via foliar, na forma de ácido silícico estabilizado, sobre a incidência de doenças, produtividade e qualidade de batata. Foram realizados três experimentos: um com a cultivar Agata e outro com a Atlantic, em Botucatu, SP; e um com a cultivar Agata, em Itaí, SP. Utilizou-se delineamento de blocos ao acaso, com oito repetições. Os tratamentos consistiram de: testemunha (sem aplicação de Si) e aplicação de Si via foliar, na dose 2 L ha-1, de produto comercial com 0,8% de Si solúvel como concentrado estabilizado de ácido silícico. A dose de Si foi parcelada em quatro aplicações durante o ciclo da cultura. A aplicação de Si reduz a severidade da requeima e a incidência de canela-preta, além de aumentar a produtividade e o teor de matéria seca dos tubérculos. O fornecimento de Si via foliar aumenta a produtividade de tubérculos, independentemente de seus efeitos sobre a incidência de doenças.
Resumo:
Com o objetivo de avaliar o efeito da presença do extrato pirolenhoso (EP) na calda de pulverização sobre o teor foliar de nutrientes de limoeiro 'Cravo' (Citrus limonia Osbeck), foi desenvolvido um experimento com seis tratamentos e quatro repetições, em blocos ao acaso, em ambiente protegido. Os tratamentos constituíram da pulverização das soluções: T0 = água; T1 = solução de micronutrientes sem EP; T2 = solução de micronutrientes + EP (1cm³ dm-3); T3 = solução de micronutrientes + EP (2 cm³ dm-3); T4 = solução de micronutrientes + EP (5cm³ dm-3); T5 = solução de micronutrientes + EP (10 cm³ dm-3). A solução de micronutrientes foi preparada com sulfatos de Cu, Fe, Mn, Zn (250 mg dm-3 do elemento) e ácido bórico (42,5 mg dm-3 de B). As plantas foram cultivadas em tubetes cônicos de 0,280 dm³, com substrato sem a adição de micronutrientes na formulação. As soluções foram pulverizadas uma única vez, aos 140 dias após o plantio (DAP), momento em que as plantas apresentavam aproximadamente 20 cm de altura. Ao final do experimento (160 DAP), quantificaram-se a massa seca e os teores de macro e micronutrientes da parte aérea e sistema radicular. A presença do extrato pirolenhoso na solução de micronutrientes não interferiu na concentração foliar de B, Fe e Zn em mudas de limoeiro 'Cravo'. Entretanto, na concentração de 10 cm³ dm-3, aumentou a concentração foliar de Cu e Mn. Observou-se também que as plantas pulverizadas com soluções contendo EP (1 a 10 cm³ dm-3) + micronutrientes apresentaram menor teor de Fe e maior teor de Ca no sistema radicular.
Resumo:
Os objetivos do trabalho foram: quantificar as exposições dérmicas e respiratórias potenciais proporcionadas ao tratorista em pulverizações de agrotóxicos, na cultura de goiaba, com o turbopulverizador; avaliar a eficiência de duas vestimentas de proteção individual; avaliar a segurança e classificar estas condições de trabalho em seguras ou inseguras para cada agrotóxico considerado. A exposição dérmica potencial proporcionada ao tratorista pela condição de trabalho foi de 3.807,3 mL de calda/7h. A eficiência do conjunto de proteção individual Agro Light foi de 96,7 %, e a do Azeredo, 96,2 %. A exposição dérmica potencial nas regiões do corpo mais expostas do tratorista à pulverização, em ordem decrescente, foram os pés, os braços, as coxas+pernas-frente e o tronco-atrás. A exposição dérmica não-controlada pelos conjuntos de proteção individual foi igualmente distribuída em todas as regiões do corpo do tratorista devido aos controles das exposições dérmicas que proporcionaram às regiões mais expostas do corpo. Foram classificadas como seguras as pulverizações de três dos 17 agrotóxicos considerados e sete com o uso das vestimentas de proteção individual. As demais foram classificadas como inseguras.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Realizou-se pesquisa objetivando determinar o melhor entre quatro pontos de colheita da haste floral de crisântemos de maço do tipo pompom cv. White Polaris a concentração mais adequada de sacarose para tratamento de pulsing dessas hastes: estas foram colhidas em estufa de produção comercial, nos pontos preestabelecidos e transportadas para laboratório, onde foram totalmente imersas em água de torneira, à sombra, durante três horas. Selecionaram-se as hastes pela uniformidade do seu desenvolvimento e cortaram-nas sob água na base do caule, entre 50 e 60 cm, e identificadas, o que permitiu avaliar as mudanças morfológicas associadas às inflorescências individuais. As hastes foram distribuídas e mantidas nos diferentes tratamentos de pulsing durante 24 horas, à luz branca contínua de 1.500 lux, 60 a 90% de umidade relativa do ar e temperatura ambiente de 25 ± 2°C. Após o tratamento de pulsing, as hastes foram transferidas para água destilada, permanecendo por 10 horas sob luz branca contínua, nas mesmas condições de laboratório citadas. A vida floral em vaso começou a ser avaliada na instalação do experimento, após o tratamento de pulsing, e terminou quando as folhas e pétalas perderam a turgescência e o valor decorativo. As hastes colhidas em estádio de botão (25 e 50% de abertura das inflorescências apicais) não alcançaram o ponto de abertura adequado em nenhuma das seis concentrações de sacarose (0 a 146,07 mol/m³); as concentrações de 116,9 146,1 mol/m³, porém, estimularam, em geral, a abertura de botões. Os pontos de colheita 1 e 2 (100 e 75% de abertura das inflorescências apicais respectivamente) apresentaram bons resultados em todas as concentrações de sacarose.