946 resultados para Sewage Effluent


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Water quality was monitored at the upper course of the Rio das Velhas, a major tributary of the São Francisco basin located in the state of Minas Gerais, over an extension of 108 km from its source up to the limits with the Sabara district. Monitoring was done at 37 different sites over a period of 2 years (2003-2004) for 39 parameters. Multivariate statistical techniques were applied to interpret the large water-quality data set and to establish an optimal long-term monitoring network. Cluster analysis separated the sampling sites into groups of similarity, and also indicated the stations investigated for correlation and recommended to be removed from the monitoring network. Principal component analysis identified four components, which are responsible for the data structure explaining 80% of the total variance of the data. The principal parameters are characterized as due to mining activities and domestic sewage. Significant data reduction was achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The toxicity of surface waters in a zone with mining activity in the Aconcagua River was determined through growth inhibition bioassays of Pseudokirchneriella subcapitata, and correlated with heavy metal concentrations. Results show that the waters near the discharge of the mining effluent displayed toxicity during all periods of study; the molybdenum and copper concentration exceeded the norms of water quality. The correlations between the concentrations of metals and the growth rate of P. subcapitata varied in the different periods of the study; inverse and significant correlations with copper stand out in some periods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dairy wastewater is characterized by frequent episodes of drastic increases of organic content, giving rise to bulking filamentous bacteria and compromising the biological treatment process. This study reports the reduction of organic content of such wastewater by the application of the solar photo-Fenton process. For a wastewater containing 335, 2627 or 5400 mg C L-1 between 90% and 50% of the organic carbon content were removed after 3.5 h irradiation. The results show that the solar photo-Fenton process can be a good alternative for the abatement of organic content of dairy wastewater, especially in cases of organic content fluctuation, allowing an efficient biological treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actualment a Catalunya existeixen zones amb importants limitacions per l’aplicació de purins al sòl, pel que és imprescindible trobar alternatives de gestió i tractament que permetin l’aprofitament adequat dels recursos continguts a les dejeccions ramaderes sense afectar el medi. La digestió anaeròbia és una de les tècniques utilitzades en el tractament de les dejeccions ramaderes. L’efluent líquid que s’obté d’aquest tractament no modifica el contingut de nitrogen i fòsfor i per tant ha de ser gestionat correctament. L’objectiu general d’aquest projecte és avaluar la precipitació d’estruvita (sal de magnesi, amoni i fosfat) com una alternativa de gestió de l’efluent líquid d’una planta de digestió anaeròbia i compostatge que tracta dejeccions ramaderes conjuntament amb altres residus orgànics. S’han avaluat els efectes dels diferents paràmetres operacionals en la formació d’estruvita (pH, temperatura, velocitat d’agitació, alcalinitat), mitjançant assaigs en discontinu amb solució sintètica. A continuació s’ha procedit a obtenir estruvita a partir de la fracció líquida digerida de purí (FLD), en assaigs en discontinu per estudiar l’efecte del contingut de matèria orgànica i sòlids Totals (ST), així com el contingut en fosfats i el pH de reacció. Finalment, s’han optimitzat els paràmetres de procés en continu, mitjançant la posada en marxa d’un reactor a escala de laboratori i estudi de l’efecte de la velocitat d’agitació i de la introducció del stripping de CO2, tant amb solució sintètica com amb la fracció líquida digerida del purí. Dels resultats obtinguts es pot concloure que els factors que tenen una major influència en el procés d’obtenció d’estruvita són el pH (el pH òptim es situa al voltant de 9), i la presència de matèria orgànica i sòlids ens suspensió, que interfereix de forma quantitativa i qualitativa en la formació de l’estruvita. En el procés en continu s’ha aconseguit reduccions d’un 84% i 98% d’amoni i fòsfor respectivament, obtenintse estruvita que pot ser utilitzada com a fertilitzant d’alliberació lenta. Es pot concloure que la precipitació d’estruvita és una bona alternativa per millorar la gestió de les dejeccions ramaderes alhora que permet recuperar nutrients i tancar cicles. La combinació amb un tractament previ que elimini la matèria orgànica, com podria ser la digestió anaeròbia, i una separació de fases, per eliminar els sòlids en suspensió, es presenta com una configuració amb molts avantatges.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ozonation tests with and without prior filtration by means of a 50 micron mesh cartridge filter were conducted with primary sanitary effluents. Filtration led to increased inactivation efficiencies with regard to total and thermotolerant coliforms but it did not seem to influence heterotrophic plate count (HPC) bacteria inactivation efficiencies significantly. Application of the Chick-Watson model to experimental data obtained in the situation of constant inactivation showed that the ozone dosage was more important to bacterial inactivation than the contact time with regard to the cases of thermotolerant coliform inactivation in filtered samples and HPC bacteria and total coliform inactivation in non-filtered samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The influence of nitric-perchloric, aqua regia, dry ashing and microwave digestion methods, in combination with 100 and 200 mg of sample, on the characterization and recovery of nutrients in samples of sludge sewage, poultry, swine, quail and bovine manures, organic compost, organic substrate and humic material were studied. Nitric-perchloric digestion with 200 mg samples recovered the higher nutrient contents. The nitric-perchloric method recovered also low levels of K. Dry ashing caused S volatilization and microwave digestion produced dark color extracts and this impaired S determination. Aqua regia recovered the lowest contents of nutrients in the organic residues evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The alteration of soil chemicals and its influence on availability (DTPA extractant method) and phytoavailability (63Ni L-value, isotopic method) of Ni was studied in sewage sludge-amended soil at different pHs. The soil pHs were 4.3, 5.3 and 5.9 and the rates of sewage sludge (SS) 0, 15, 30, 45 and 60 Mg ha-1. The chemical and physicochemical soil characteristics were altered by the SS rate and increased the Ni availability and phytoavailability. The isotopic method (63Ni L-value) was more efficient in predicting the Ni phytoavailability that the Ni-DTPA extractant in soil pHs 5.3 and 5.9.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Organic markers, such as sterols and ketones, were used to assess sewage contamination in sediments from the Santos Bay, SP, and its continental shelf. These compounds were analyzed by GC/FID after soxhlet extraction, clean up and derivatization. The concentration of coprostanol and ratios between selected sterols were used to evaluate fecal contamination. The stations located in the mid-western part of the Santos Bay presented organic matter from sewage due to the input of fecal material from the city of Santos by submarine sewage outfall. Stations located at the continental shelf did not present fecal contamination. Coprostanol levels in sewage outfall stations were higher in comparison to other Brazilian coastal areas, except Guanabara Bay/RJ, and could be related to the fraction of the population without sewage treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Cd phytoavailability in sewage sludge-amended soils of different pHs using the 109Cd L-value isotopic method and Cd extracted by DTPA has been determined. Maize plants (Zea mais L.) were grown under greenhouse conditions in a xanthic ferralsol at different pHs amended with five sewage sludge (SS) rates, and labeled with 74 kBq kg-1 of 109Cd. The SS rates altered the properties of the soil chemicals and these influenced the isotopic parameter (L-value) and percent of Cd uptake by plants from soil (%Cdpdfs) and SS (%CdpdfSS). L-values and Cd extracted by DTPA correlate significantly with SS rates and Cd uptake by plants and are efficient for predicting the Cd phytoavailability in the sewage sludge-amended soil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudi de la climatització d'una instal•lació esportiva,concretament una piscina coberta municipal, a partir de la calor recuperada de les aigües residuals urbanes (ARU) que produeix una població de 30.000 habitants. En la primera part de l'estudi s'ha calculat la potència màxima per cobrir les quatrenecessitats de la instal•lació en règim estacionari, que ha resultat ser de 265,8 kW,repartits en 69,1 kW per cobrir les necessitats del vas de la piscina, 102,5 kW percobrir les necessitats en l'aire interior de la sala de la piscina, 30,2 kW per cobrir lesnecessitats tèrmiques calorífiques de les sales annexes i 64 kW per cobrir lesnecessitats en la producció d'aigua calenta sanitària (ACS). A continuació també s'hadeterminat l'estimació de la despesa total anual de la instal•lació que és de 1.179MWh/any. El 48% aproximadament de la despesa total es destina a cobrir lesnecessitats del vas de la piscina, el 28% per cobrir la producció d'ACS, el 20% percobrir les necessitats de la sala de la piscina i el 4% per cobrir les necessitatscalorífiques a hivern de les sales annexes

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to evaluate the use of natural zeolites to remove the NH4+ that remains in effluents from swine facilities which were submitted to physico-chemical and biological treatments. Experiments were made in batch made adding 5% (w/w) of adsorbent (0.6-1.3 and 3.0-8.0 mm) to synthetic and real swine facilities effluents. The results show that ammonium removal is influenced by adsorbent particle size and the presence of other ions in the effluent. The adsorption equilibrium was described by Langmuir as well as Freundlich isotherms and the kinetic data fitted well a pseudo-second order model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

On a laboratory scale effluents were produced from bichromic dyeing of acrylic fabrics with the basic dyes Blue Astrazon FGGL 300% and Yellow Gold Astrazon GL 200%. The residual dyeing baths were subjected to a photoelectrochemical treatment and reused in a second dyeing process. In the reutilization study, dyeings with treated effluent were compared with standard dyeings with distilled water. The results of dyeings using 100% of treated effluent were unsatisfactory, but the substitution of 10 to 30% of the treated effluent by distilled water resulted in reduced and more acceptable values for difference in colour intensity (ΔE) between 1.86 and 0.3.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sediment samples from the Barigui River in Curitiba, south of Brazil, were evaluated following granulometric composition, organic carbon content, nitrogen, phosphorus and metals such as zinc, lead, chrome, nickel and cadmium. The sediments shown high percentage of phosphorus and nitrogen. Also the elemental organic C:N:P exceed the Redfield ratios possible because the large amount of sewage input into river. The presence of metals is also high, however the metal cadmium has not been found. But the other metals are in greater concentrations and possibly the presence of these metals is given by industrial and domestic sewage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The degradation of disperses dyes in aqueous solution and in effluents from textile industry has been investigated by photoelectrocatalytic oxidation using nanoporous thin films electrodes of Ti/TiO2. Samples of dispersil black dye and dispersil blue dye after 300 min of photoelectrolyzed at applied potential of +1.0 V and UV irradiation exhibited 100% of discoloration and 90% and 64% reduction total organic carbon, respectively. The proposed method was applied with success in a textile industry effluent containing residues of these dyes, which after 300 min of treatment leads to reduction of 60% of COD and 64% removal of TOC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concern about aquatic ecosystems and the potential risk of drinking water contamination by pharmaceuticals have stimulated the study of processes for the efficient degradation of these contaminants, since the conventional treatment have been inefficient on that purpose. The advanced oxidation processes (AOPs) appear as viable alternatives due to their efficiency on the degradation of different classes of organic contaminants. This review presents an overview of the main AOP (O3, H2O2/UV, TiO2/UV, Fenton and photo-Fenton) which have been applied to the degradation of different pharmaceuticals. The main results obtained, intermediates identified and toxicity data are presented.