908 resultados para Scotchbond Dual Cure
Resumo:
The dual path of insertion concept for removable partial denture (RPD) design may be used in esthetically demanding situations. When compared to conventional RPDs, the main advantage of this design is the minimal use of clasps. This clinical report describes the treatment of a patient with an anterior maxillary edentulous area using a dual path RPD. The diagnostic cast was surveyed to ensure the adequacy of the undercuts on the mesial surfaces of the anterior abutments, where rigid minor connectors were placed. Inverted V-shaped canine cingulum rest seats were prepared to provide resistance to tooth movement during function. The dual path RPD concept allows excellent esthetic results, minimizes tooth preparation, and reduces the tendency toward plaque accumulation in a Kennedy class IV partially edentulous arch. © 2008 by The American College of Prosthodontists.
Resumo:
Includes bibliography
Resumo:
Includes bibliography
Resumo:
This study evaluated the Knoop hardness and polymerization depth of a dual-cured resin cement, light-activated at different distances through different thicknesses of composite resin. One bovine incisor was embedded in resin and its buccal surface was flattened. Dentin was covered with PVC film where a mold (0.8-mm-thick and 5 mm diameter) was filled with cement and covered with another PVC film. Light curing (40 s) was carried out through resin discs (2, 3, 4 or 5 mm) with a halogen light positioned 0, 1, 2 or 3 mm from the resin surface. After storage, specimens were sectioned for hardness measurements (top, center, and bottom). Data were subjected to split-plot ANOVA and Tukey's test (α=0.05). The increase in resin disc thickness decreased cement hardness. The increase in the distance of the light curing tip decreased hardness at the top region. Specimens showed the lowest hardness values at the bottom, and the highest at the center. Resin cement hardness was influenced by the thickness of the indirect restoration and by the distance between the light-curing unit tip and the resin cement surface.
Resumo:
Objective: To evaluate the influence of three adhesive systems on the bond strength of fiber post luted to root dentine. The hypothesis was that the bond strength is influenced by the adhesive system. Method: The canals of thirty single-root bovine roots (16mm in length) were prepared using the preparation drill (FGM) until 12mm. 14 mm of each root was embedded with acrylic resin and the specimens were allocated into three groups (n=10), considering the factor adhesive (3 levels): Gr1- Scotchbond Multipurpose Plus (3M ESPE), Gr2- One Step (Bisco) and Gr3- Excite DSC (Ivoclar Vivadent). The adhesive systems were applied using a microbrush, according to the manufacture's recommendations. The fiber posts (White Post DC, FGM) were luted with dual resin cement (All-Cem,FGM). After, the cores with composite resin (Llis, FGM) were made and each set of root/post/core was submitted to the mechanical cycling (Erios, Brazil) (10 6 cycles, 84N, 4 Hz, inclination of 45 o, 37 oC, water). Each specimen was cut in 4 samples (1.8mm in thickness), which were submitted to the push-out test in a universal testing machine (ServoPulser - Shimadzu) (50Kgf, 1mm/min). The data (MPa) were analyzed using ANOVA (1-way) and Tukey test (5%). Results: The factor adhesive (P=0.00352) influenced the bond strength significantly (ANOVA). Gr1 (6.8±3.8 MPa) a presented higher bond strength values than Gr2 (3.1±1.5 MPa) b and similar to Gr3 (4.4±3.3) a,b. Moreover, Gr3 and Gr2 were similar between them (Tukey). The hypothesis was accepted. Conclusion: Based on the results it was concluded that chemical and dual polymerization adhesive system should be used for the adhesive luting fiber post procedures.
Resumo:
Aim: In this study, we evaluated the effect of photopolymerization on Vickers microhardness of dual-polymerized resin cement at three locations when a translucent quartz fiber post was used. Materials and Methods: Single-rooted bovine teeth received quartz fiber post systems (length: 12 mm) using a dual-polymerized resin cement. In Group 1, the posts were cemented but not photopolymerized, and in Group 2, the posts were both cemented and photopolymerized. After cementation, approximately 1.5-mm thick sections were obtained (two cervical, two middle, and two apical) for regional microhardness evaluations. Statistical Analysis: Statistical analyses were performed using the SPSS software (ver. 11.0 for Windows; SPSS, Inc., Chicago, IL, USA). Microhardness (kg/mm 2 ) data were submitted to two-way analysis of variance (two-way ANOVA) and repeated measures with microhardness values as the dependent variable and polymerization status (two levels: with and without) and root region (three levels: cervical, middle, and apical) as independent variables. Multiple comparisons were made using Dunnett's T3 post-hoc test. P values of <0.05 were considered to indicate statistical significance in all tests. Results: Photopolymerization did not significantly change the microhardness values when compared with no photopolymerization. Microhardness values also showed no significant difference between the three regions in the root canals in both groups. Conclusions: The mode of polymerization of the cement tested in combination with the translucent quartz fiber post system did not affect the microhardness of the cement at the cervical, middle, or apical regions of the root.
Resumo:
Publicado separadamente en cada idioma
Resumo:
Includes bibliography
Resumo:
Incluye Bibliografía
Resumo:
Includes bibliography
Resumo:
Purpose: Adhesive cementation is an important step for restorations made of feldspathic ceramic as it increases the strength of such materials. Incorrect selection of the adhesive resin and the resin cement to adhere to the ceramic surface and their durability against aging can affect the adhesion between these materials and the clinical performance. This study evaluated the effect of adhesive resins with different pHs, resin cements with different polymerization modes, and aging on the bond strength to feldspathic ceramic. Materials and Methods: One surface of feldspathic ceramic blocks (VM7) (N = 90) (6.4 × 6.4 × 4.8 mm3) was conditioned with 10% hydrofluoric acid for 20 seconds, washed/dried, and silanized. Three adhesive resins (Scotchbond Multi-Purpose Plus [SBMP], pH: 5.6; Single Bond [SB], pH: 3.4; and Prime&Bond NT [NT], pH: 1.7) were applied on the ceramic surfaces (n = 30 per adhesive). For each adhesive group, three resin cements with different polymerization modes were applied (n = 10 per cement): photo-polymerized (Variolink II base), dual polymerized (Variolink II base + catalyst), and chemically polymerized (C&B). The bonded ceramic blocks were stored in water (37°C) for 24 hours and sectioned to produce beam specimens (cross-sectional bonded area: 1 ± 0.1 mm2). The beams of each block were randomly divided into two conditions: Dry, microtensile test immediately after cutting; TC, test was performed after thermocycling (12,000×, 5°C to 55°C) and water storage at 37°C for 150 days. Considering the three factors of the study (adhesive [3 levels], resin cement [3 levels], aging [2 levels]), 18 groups were studied. The microtensile bond strength data were analyzed using 3-way ANOVA and Tukey's post hoc test (α= 0.05). Results: Adhesive resin type (p < 0.001) and the resin cement affected the mean bond strength (p= 0.0003) (3-way ANOVA). The NT adhesive associated with the chemically polymerized resin cement in both dry (8.8 ± 6.8 MPa) and aged conditions (6.9 ± 5.9 MPa) presented statistically lower bond strength results, while the SBMP adhesive resin, regardless of the resin cement type, presented the highest results (15.4 to 18.5 and 14.3 to 18.9 MPa) in both dry and aged conditions, respectively (Tukey's test). Conclusion: Application of a low-pH adhesive resin onto a hydrofluoric acid etched and silanized feldspathic ceramic surface in combination with chemically polymerized resin cement did not deliver favorable results. The use of adhesive resin with high pH could be clinically advised for the photo-, dual-, and chemically polymerized resin cements tested. © 2012 by the American College of Prosthodontists.
Correspondence between the self-dual model and the topologically massive electrodynamics: A new view
Resumo:
Following the study of the Topologically Massive Theories under the Hamilton-Jacobi, we now analyze the constraint structure of the Self-Dual model as well as its correspondence with the Topologically Massive Electrodynamics. © 2013 American Institute of Physics.
Resumo:
Incluye Bibliografía
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS