986 resultados para SONIC-SPRAY IONIZATION
Resumo:
The study of wave propagation at sonic frequency in soil leads to elasticity parameter determination. These parameters are compatible to those measured simultaneously by static loading. The acquisition of in situ elasticity parameter combined with laboratory description of the elastoplastic behaviour can lead to in situ elastoplastic curves. - L'étude de la propagation des ondes acoustiques permet la détermination des paramètres d'élasticité dans les sols. Ces paramètres sont cohérents avec des mesures statiques simultanées. L'acquisition des paramètres d'élasticité in situ associée à une description du comportement élasto-plastique mesuré en laboratoire permet d'obtenir des courbes d'élastoplasticité in situ.
Resumo:
Five field populations of Musca domestica L. collected in poultry farms were bioassayed in order to detect possible resistance to the larvicide cyromazine in Brazil. The concentrations used were 0, 0.5, 0.1, 0.2, 0.4, 1, 2, 4 and 8 ppm. Three populations (Petrópolis, RJ, Montes Claros, MG and Promissão, SP) were resistant, while the other two populations (Ibiuna, SP and Monte Mor, SP) were more susceptible than the reference pathern used by the World Health Organization. The presence of three resistant house fly populations to cyromazine in Brazilian poultry farms strongly suggests that the operational aspects of larvicide use are important for the resistance development. Cyromazine is applied as a feed-through, both in Brazil and in the USA, where resistance has already been documented. However, in Denmark, where it was approved only as a topical manure spray, no case of resistance has yet been detected.
Resumo:
Imaging mass spectrometry (IMS) is an emergent and innovative approach for measuring the composition, abundance and regioselectivity of molecules within an investigated area of fixed dimension. Although providing unprecedented molecular information compared with conventional MS techniques, enhancement of protein signature by IMS is still necessary and challenging. This paper demonstrates the combination of conventional organic washes with an optimized aqueous-based buffer for tissue section preparation before matrix-assisted laser desorption/ionization (MALDI) IMS of proteins. Based on a 500 mM ammonium formate in water-acetonitrile (9:1; v/v, 0.1% trifluororacetic acid, 0.1% Triton) solution, this buffer wash has shown to significantly enhance protein signature by profiling and IMS (~fourfold) when used after organic washes (70% EtOH followed by 90% EtOH), improving the quality and number of ion images obtained from mouse kidney and a 14-day mouse fetus whole-body tissue sections, while maintaining a similar reproducibility with conventional tissue rinsing. Even if some protein losses were observed, the data mining has demonstrated that it was primarily low abundant signals and that the number of new peaks found is greater with the described procedure. The proposed buffer has thus demonstrated to be of high efficiency for tissue section preparation providing novel and complementary information for direct on-tissue MALDI analysis compared with solely conventional organic rinsing.
Resumo:
La deficiencia de vitamina A causa 2.2 millones de muertes al año. Por tanto, investigadores intentan elevar el contenido de β-caroteno y otros carotenoides en cereales mediante la ingeniería genética. Mi trabajo consistió en analizar carotenoides en maíz y callos de arroz transgénico con el fin de indentificar y cuantificar estos pigmentos y además analizar la ruta metabólica de los mismos. Por tal motivo, desarrollaré una técnica analítica por HPLC y UHPLC que me permitió separar la mezcla de carotenoides. Estas moléculas se detectaton utilizando un detector de arreglo de diodos y masas. Con éste último se probaron distintas técnicas de ionización (ESI, APCI y APPI) para encontrar la mejor técnica que ionizara carotenos y xantófilas. Además se hallaron transiciones para identificar a cada uno de los carotenoides. Para mostrar la confiabilidad del método analítico, realicé la validación del mismo y determiné factores importantes que influyen en el análisis de carotenoides, como por ejemplo, su estabilidad química. Para analizar la ruta metabólica de los carotenoides, se realizaron distintos experimentos, entre ellos, introducir distintas combinaciones de genes en el maíz y arroz que permitieran entender cuáles eran las enzimas importantes que permitían la acumulación de carotenoides. También se analizó la biosíntesis de carotenoides a distintas etapas del desarrollo de la semilla de maíz, desde los 15 días después de la polinización (DAP) hasta los 60 DAP y su estabilidad química a lo largo de todo este período. Finalmente, se profundizó en la identificación de nuevos carotenoides encontrados en las muestras, como los oxo-carotenoides (utilizados en la industria como colorantes). Para llevar acabo su identificación, se realizaron pruebas químicas, se determinaron sus espectros visibles y sus fragmentos por masas.
Resumo:
PURPOSE OF REVIEW: Invasive candidiasis is a severe infectious complication occurring mostly in onco-hematologic and surgical patients. Its conventional diagnosis is insensitive and often late, leading to a delayed treatment and a high mortality. The purpose of this article is to review recent contributions in the nonconventional diagnostic approaches of invasive candidiasis, both for the detection of the epidose and the characterization of the etiologic agent. RECENT FINDINGS: Antigen-based tests to detect invasive candidiasis comprise a specific test, mannan, as well as a nonspecific test, beta-D-glucan. Both have a moderate sensitivity and a high specificity, and cannot be recommended alone as a negative screening tool or a positive syndrome driven diagnostic tool. Molecular-based tests still have not reached the stage of rapid, easy to use, standardized tests ideally complementing blood culture at the time of blood sampling. New tests (fluorescence in-situ hybridization or mass spectrometry) significantly reduce the delay of identification of Candida at the species level in positive blood cultures, and should have a positive impact on earlier appropriate antifungal therapy and possibly on outcome. SUMMARY: Both antigen-based and molecular tests appear as promising new tools to complement and accelerate the conventional diagnosis of invasive candidiasis with an expected significant impact on earlier and more focused treatment and on prognosis.
Resumo:
Enriched by a decade of remarkable developments, matrix-assisted laser desorption ionization imaging mass spectrometry (MALDI IMS) has witnessed a phenomenal expansion. Initially introduced for the mapping of peptides and intact proteins from mammalian tissue sections, MALDI IMS applications now extend to a wide range of molecules including peptides, lipids, metabolites and xenobiotics. Technology and methodology are quickly evolving to push the limits of the technique forward. Within a short period of time, numerous protocols and concepts have been developed and introduced in tissue section preparation, nonexhaustively including in situ tissue chemistries and solvent-free matrix depositions. Considering the past progress and current capabilities, this Review aims to cover the different aspects and challenges of tissue section preparation for MALDI IMS.
Resumo:
Usually, the differentiation of inks on questioned documents is carried out by optical methods and thin layer chromatography (TLC). Therefore, spectrometric methods were also proposed in forensic literature for the analysis of dyes. Between these techniques, laser desorption/ionization mass spectrometry (LDI-MS) has demonstrated a great versatility thanks to its sensitivity to blue ballpoint ink dyes and minimal sample destruction. Previous researches concentrated mostly on the LDI-MS positive mode and have shown that this analytical tool offers higher discrimination power than high performance TLC (HPTLC) for the differentiation of blue ballpoint inks. Although LDI-MS negative mode has already been applied in numerous forensic domains like the studies of works of art, automotive paints or rollerball pens, its potential for the discrimination of ballpoint pens was never studied before. The aim of the present paper is therefore to evaluate its potential for the discrimination of blue ballpoint inks. After optimization of the method, ink entries from 33 blue ballpoint pens were analyzed directly on paper in both positive and negative modes by LDI-MS. Several cationic and anionic ink components were identified in inks; therefore, pens were classified and compared according to their formulations. Results show that additional information provided by anionic dyes and pigments significantly increases the discrimination power of positive mode. In fact, it was demonstrated that classifications obtained by the two modes were, to some extent, complementary (i.e., inks with specific cationic dyes not necessarily contained the same anionic components).
Resumo:
The manuscript describes a study on the blood cholinesterase (ChE) level in an exposed population at different interval of time after spraying with malathion suspension (SRES) use for kala-azar vector control in an endemic area of Bihar, India. The toxicity of a 5% malathion formulation in the form of a slow release emulsified suspension (SRES) was assessed by measuring serum ChE levels in spraymen and in the exposed population.The study showed a significant decrease in ChE levels in the spraymen (p < 0.01) after one week of spraying and in exposed population one week and one month after of spraying (p < 0.01), but was still within the normal range of ChE concentration, one year after spraying, the ChE concentration in the exposed population was the same as prior to spraying (p > 0.01). On no occasion was the decrease in ChE level alarming. A parallel examination of the clinical status also showed the absence of any over toxicity or any behavioural changes in the exposed population. Hence, it may be concluded that 5% malathion slow release formulation, SRES, is a safe insecticide for use as a vector control measure in endemic areas of kala-azar in Bihar, India so long as good personal protection for spraymen is provided to minimize absorption and it can substitute the presently used traditional DDT spray.
Resumo:
Insecticide effects of deltamethrin 2.5% SC (flowable solution) on different substrates and triatomine infestation rates in two indigenous villages (Estancia Salzar and Nueva Promesa) of the Paraguayan Chaco are reported. This field study was carried out to determine the extent to which variability in spray penetration may affect residual action of the insecticide. A total of 117 houses in the two villages were sprayed. Filter papers discs were placed on aluminium foil pinned to walls and roofs in selected houses and the applied insecticide concentration was determined by high pressure liquid chromatography (HPLC). The target dose rate was 25 mg a.i./m². The mean actual applied dose in Estancia Salazar was 11.2 ± 3.1 mg a.i./m² in walls and 11.9 ± 5.6 mg a.i./m² in roofs while in Nueva Promesa, where duplicates were carried out, the mean values were 19.9 ± 6.9 mg a.i./m² and 34.7 ± 10.4 mg a.i./m² in walls and 28.8 ± 19.2 mg a.i./m² and 24.9 ± 21.8 mg a.i./m² in roofs. This shows the unevenness and variability of applied doses during spraying campaigns, and also the reduced coverage over roof surfaces. However, wall bioassays with Triatoma infestans nymphs in a 72 h exposure test showed that deposits of deltamethrin persisted in quantities sufficient to kill triatomines until three months post spraying. Knockdown by deltamethrin on both types of surfaces resulted in 100% final mortality. A lower insecticidal effect was observed on mud walls. However, three months after treatment, sprayed lime-coated mud surfaces displayed a twofold greater capacity (57.5%) to kill triatomines than mud sprayed surfaces (25%). Re-infestation was detected by manual capture only in one locality, six months after spraying,
Resumo:
OBJECTIVE: To assess the impact of instructional guidance in the regular use of use nicotine nasal spray (NNS) on the true use of NNS during the first three weeks of smoking cessation for heavy smokers who are willing to quit. METHODS: This randomized, open, controlled trial included 50 patients who were heavy smokers, were willing to quit, and attending an academic outpatient clinic in Western Switzerland. Patients were randomised to instruction on NNS use as "ad libitum" (administration whenever cravings appear; control group) or to use NNS when craving appears and at least every hour when awake (intervention group). Intakes were monitored using an electronic device fixed in the spray unit (MDILog) during the first three weeks of use. Self reported abstinence from smoking at six months was confirmed by expired-air carbon monoxide. Using intention-to-treat analysis, random-effect GLS regression was used to calculate the mean difference of daily doses between groups controlling for lack of independence between measures from the same individual. RESULTS: One patient was lost to follow-up. At baseline randomization, the group receiving instruction to use NNS hourly included more women, patients with previous desires to quit, and patients with more psychiatric comorbidities and less somatic complaints compared to the group instructed to use NNS with cravings (group imbalance). Both groups self-administered more than the daily recommended dosage of 8 uses. Mean daily usage was 13.6 dose/day and 11.1 dose/day for the group instructed to use NNS hourly and with cravings, respectively. Adjusting for baseline imbalance, the increased daily doses in the intervention group (hourly use) remained nonsignificant compared to ad libitum use (-0.5 dose/day; CI 95% -6.2; 5.3, from day 1 to day 7; and 2.3 dose/day; CI 95% -5.4; 10.0, from day 8 to day 21). Instructing patients to use the NNS daily had no effect on smoking cessation at six months (RR = 0.69; CI 95% 0.34; 1.39). CONCLUSION: Heavy smokers willing to quit use NNS frequently, regardless of the instructions given. Recommending the use of NNS only when craving appears for heavy smokers willing to quit seems acceptable compared to prescribing hourly administration. TRIAL REGISTRATION: ClinicalTrials.gov: NCT00861276.
Resumo:
A survey was undertaken among Swiss occupational health and safety specialists in 2004 to identify uses, difficulties, and possible developments of exposure models. Occupational hygienists (121), occupational physicians (169), and safety specialists (95) were surveyed with an in depth questionnaire. Results obtained indicate that models are not used very much in practice in Switzerland and are reserved to research groups focusing on specific topics. However, various determinants of exposure are often considered important by professionals (emission rate, work activity), and in some cases recorded and used (room parameters, operator activity). These parameters cannot be directly included in present models. Nevertheless, more than half of the occupational hygienists think that it is important to develop quantitative exposure models. Looking at research institutions, there is, however, a big interest in the use of models to solve problems which are difficult to address with direct measurements; i. e. retrospective exposure assessment for specific clinical cases and prospective evaluation for new situations or estimation of the effect of selected parameters. In a recent study about cases of acutepulmonary toxicity following water proofing spray exposure, exposure models have been used to reconstruct exposure of a group of patients. Finally, in the context of exposure prediction, it is also important to report about a measurement database existing in Switzerland since 1991. [Authors]
Resumo:
Tobacco consumption is a global epidemic responsible for a vast burden of disease. With pharmacological properties sought-after by consumers and responsible for addiction issues, nicotine is the main reason of this phenomenon. Accordingly, smokeless tobacco products are of growing popularity in sport owing to potential performance enhancing properties and absence of adverse effects on the respiratory system. Nevertheless, nicotine does not appear on the 2011 World Anti-Doping Agency (WADA) Prohibited List or Monitoring Program by lack of a comprehensive large-scale prevalence survey. Thus, this work describes a one-year monitoring study on urine specimens from professional athletes of different disciplines covering 2010 and 2011. A method for the detection and quantification of nicotine, its major metabolites (cotinine, trans-3-hydroxycotinine, nicotine-N′-oxide and cotinine-N-oxide) and minor tobacco alkaloids (anabasine, anatabine and nornicotine) was developed, relying on ultra-high pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC-TQ-MS/MS). A simple and fast dilute-and-shoot sample treatment was performed, followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. After method validation, assessing the prevalence of nicotine consumption in sport involved analysis of 2185 urine samples, accounting for 43 different sports. Concentrations distribution of major nicotine metabolites, minor nicotine metabolites and tobacco alkaloids ranged from 10 (LLOQ) to 32,223, 6670 and 538 ng/mL, respectively. Compounds of interest were detected in trace levels in 23.0% of urine specimens, with concentration levels corresponding to an exposure within the last three days for 18.3% of samples. Likewise, hypothesizing conservative concentration limits for active nicotine consumption prior and/or during sport practice (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N′-oxide, cotinine-N-oxide, anabasine, anatabine and nornicotine) revealed a prevalence of 15.3% amongst athletes. While this number may appear lower than the worldwide smoking prevalence of around 25%, focusing the study on selected sports highlighted more alarming findings. Indeed, active nicotine consumption in ice hockey, skiing, biathlon, bobsleigh, skating, football, basketball, volleyball, rugby, American football, wrestling and gymnastics was found to range between 19.0 and 55.6%. Therefore, considering the adverse effects of smoking on the respiratory tract and numerous health threats detrimental to sport practice at top level, likelihood of smokeless tobacco consumption for performance enhancement is greatly supported.
Resumo:
This leaflet encourages uptake of the flu vaccine for those people in at-risk groups. Most children aged 2 years up to less than 18 years in at risk groups will receive a nasal spray vaccine rather than an injection.
Resumo:
A sensitive and specific ultra performance liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of nicotine, its metabolites cotinine and trans-3'-hydroxycotinine and varenicline in human plasma was developed and validated. Sample preparation was realized by solid phase extraction of the target compounds and of the internal standards (nicotine-d4, cotinine-d3, trans-3'-hydroxycotinine-d3 and CP-533,633, a structural analog of varenicline) from 0.5mL of plasma, using a mixed-mode cation exchange support. Chromatographic separations were performed on a hydrophilic interaction liquid chromatography column (HILIC BEH 2.1×100mm, 1.7μm). A gradient program was used, with a 10mM ammonium formate buffer pH 3/acetonitrile mobile phase at a flow of 0.4mL/min. The compounds were detected on a triple quadrupole mass spectrometer, operated with an electrospray interface in positive ionization mode and quantification was performed using multiple reaction monitoring. Matrix effects were quantitatively evaluated with success, with coefficients of variation inferior to 8%. The procedure was fully validated according to Food and Drug Administration guidelines and to Société Française des Sciences et Techniques Pharmaceutiques. The concentration range was 2-500ng/mL for nicotine, 1-1000ng/mL for cotinine, 2-1000ng/mL for trans-3'-hydroxycotinine and 1-500ng/mL for varenicline, according to levels usually measured in plasma. Trueness (86.2-113.6%), repeatability (1.9-12.3%) and intermediate precision (4.4-15.9%) were found to be satisfactory, as well as stability in plasma. The procedure was successfully used to quantify nicotine, its metabolites and varenicline in more than 400 plasma samples from participants in a clinical study on smoking cessation.
Resumo:
Capillary zone electrophoresis (CZE) with UV detection has been widely used for the determination of carbohydrate-deficient transferrin (CDT), an indirect marker of the chronic alcohol consumption (≥60-80g/day). A commercially available method (CEofix? CDT kit), containing a bilayer anionic coating, allows for the analysis of CDT with a high resolution between transferrin (Tf) glycoforms with reduced protein adsorption onto the capillary wall. Although widely used in routine analysis, this procedure presents some limitations in terms of selectivity and sensitivity which may be overcome with mass spectrometry (MS). However, the available method is not MS-compatible due to the non-volatile coating as well as the phosphate and borate buffers present in the background electrolyte (BGE). This study firstly consisted in developing MS-compatible separation conditions, i.e., coating and BGE compositions. Numerous cationic, neutral, and anionic coatings were evaluated in combination with BGEs covering a broad range of pH values. A bilayer coating composed of a cationic layer of 10% polybrene (m/v) and an anionic layer of 10% dextran sulfate (m/v) combined with a BGE composed of 20mM ammonium acetate at pH 8.5 provided the best results in terms of glycoforms' resolution, efficiency, adsorption reduction, migration times' repeatability, and coating stability. The method was then transferred to CZE-MS after investigations of the electrospray ionization (ESI) source, equipped with a sheath-flow interface, and the time-of-flight (TOF/MS) parameters. A successful MS detection of tetrasialo-Tf was obtained during infusion, while the experiments highlighted the challenges and issues encountered with intact glycoprotein analysis by CZE-ESI-MS.